Search NASA⌕ Search

SEARCH · Search NASA

Results for “signal separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

An MILP-Based Distributed Energy Management for Coordination of Networked Microgrids

An MILP-based distributed energy management for the coordination of networked microgrids is proposed in this paper. Multiple microgrids and the utility grid are coordinated through iteratively adjusted price signals. Based on the price signals received, the microgrid controllers (MCs) and distribution management system (DMS) update their schedules separately. Then, the price signals are updated according to the generation–load mismatch and distributed to MCs and DMS for the next iteration. The iteration continues until the generation–load mismatch is small enough, i.e., the generation and load are balanced under agreed price signals. Through the proposed distributed energy management, various microgrids and the utility grid with different economic, resilient, emission and socio-economic objectives are coordinated with generation–load balance guaranteed and the microgrid customers’ privacy preserved. In particular, a piecewise linearization technique is employed to approximate the augmented Lagrange term in the alternating direction method of multipliers (ADMM) algorithm. Thus, the subproblems are transformed into mixed integer linear programming (MILP) problems and efficiently solved by open-source MILP solvers, which would accelerate the adoption and deployment of microgrids and promote clean energy. The proposed MILP-based distributed energy management is demonstrated through various case studies on a networked microgrids test system with three microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of 83m Kr prompt scintillation signals in the PIXeY detector

Prompt scintillation signals from 83m Kr calibration sources are a useful metric to calibrate the spatial variation of light collection efficiency and electric field magnitude of a two phase liquid-gas xenon time projection chamber. Because 83m Kr decays in two steps, there are two prompt scintillation pulses for each calibration event, denoted S1a and S1b. We study the ratio of S1b to S1a signal sizes in the Particle Identification in Xenon at Yale (PIXeY) experiment and its dependence on the time separation between the two signals (Δ t), notably its increase at low Δ t. Finally, in PIXeY data, the Δ t dependence of S1b/S1a is observed to exhibit two exponential components: one with a time constant of 0.05 ± 0.02 μ s, which can be attributed to processing effects and pulse overlap and one with a time constant of 10.2 ± 2.2 μs that increases in amplitude with electric drift field, the origin of which is not yet understood.

47 OTHER INSTRUMENTATION↗

Exploring Continuous Seismic Data at an Industry Facility Using Unsupervised Machine Learning

Seismic data recorded at industrial sites contain valuable information on anthropogenic activities. With advances in machine learning and computing power, new opportunities have emerged to explore the seismic wavefield in these complex environments. We applied two unsupervised machine learning algorithms to analyze continuous seismic data collected from an industrial facility in Texas, United States. The Uniform Manifold Approximation and Projection for Dimension Reduction algorithm was used to reduce the dimensionality of the data and generate 2D embeddings. Then, the Hierarchical Density-Based Spatial Clustering of Applications with Noise method was employed to automatically group these embeddings into distinct signal clusters. Our analysis of over 1400 hr (around 59 days) of continuous seismic data revealed five and seven signal clusters at two separate stations. At both stations, we identified clusters associated with background noise and vehicle traffic, with the latter’s temporal patterns aligning closely with the facility’s work schedule. Furthermore, the algorithms detected signal clusters from unknown sources and underline the ability of unsupervised machine learning for uncovering previously unrecognized patterns. Our analysis demonstrates the effectiveness of unsupervised approaches in examining continuous seismic data without requiring prior knowledge or pre-existing labels.

58 GEOSCIENCES↗

2D photofragmentation LIF imaging of H 2 O 2 and HO 2 in the effluent of an atmospheric-pressure plasma jet: effects of solid and liquid interfaces

Two-dimensional (2D) absolute measurements of hydrogen peroxide (H 2 O 2 ) and approximations of the hydroperoxyl radical (HO 2 ) in the effluent of a COST Reference Microplasma Jet operated with a He/H 2 O feed gas are presented. Gas-phase densities are mapped using photofragmentation laser-induced fluorescence (PF-LIF) under three boundary conditions: open effluent, a solid target, and a liquid target. A novel method is presented for separating PF-LIF signals from H 2 O 2 and HO 2 using comparative measurements in oxygen-rich and oxygen-free environments to exploit the preferential formation of HO 2 in the presence of molecular oxygen. This separation strategy is supported by results from a plug-flow plasma chemistry model. Measured densities agree closely with model predictions in both magnitude and trend, while the 2D experimental distributions provide additional insight into the spatial dependencies of these species. In particular, the results show distinct differences in species transport depending on the target type: solid surfaces induce lateral deflection and reduced centerline densities, whereas liquid interfaces promote axial accumulation and higher near-axis concentrations.

atmospheric-pressure plasma jet (APPJ)↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

42 ENGINEERING↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

Quantitative analysis method for multi-color microscopy

We developed an analysis framework for quantitatively interpreting results from multi-color fluorescence microscopy data. When the emission signal from fluorescent probes (i.e. from biological microscopy or in single-particle microscopy) is spectrally separated before detection, the resulting signals contain information about the strengths of each probe. We built a model to deconvolve the raw data into quantitative descriptions of either of the wavelength of a single probe or the relative strengths among multiple probes. This approach requires only spectrally separating the image data into two or more channels, as opposed to fully resolving the spectral profile, thus allowing other microscopy techniques to be used simultaneously. Our analysis framework incorporates the response features of the optical and imaging elements used to produce the spectral separation, yielding highly quantitative interpretations of the underlying behaviors that give rise to the data.

Ryan, Duncan↗

Softening of dd excitation in the resonant inelastic x-ray scattering spectra as a signature of Hund's coupling in nickelates

We investigate the effects of Hund's coupling on the resonant x-ray absorption spectra of the recently discovered family of layered nickelate superconductors. We contrast two scenarios depending on the relative strength of the ratio of the effective Hund's coupling ( J H ) to the crystal fields ( Δ ) in these systems. We carry out the cluster and DFT + DMFT simulations of the RIXS signal at the Ni L edge for different values of Hund's coupling. We find the latter dominates for the parent compound while the former becomes important for sufficiently large doping. Our results are consistent with the observations of a softening of a RIXS peak as a function of doping by Rossi [], only when the Hund coupling is sizable. To interpret the results, we separate the theoretical RIXS signal into spin conserving and nonspin conserving channels and conclude that the infinite layer nickelates are in a regime where Δ and J compete effectively and suggest further experimental tests of the theory. Published by the American Physical Society 2025

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Localizing Transformations of the Galaxy-Galaxy Lensing Observable

Modern cosmological analyses of galaxy-galaxy lensing face a theoretical systematic effect arising from the nonlocality of the observed galaxy-galaxy lensing signal. Because the predicted tangential shear signal at a given separation depends on the physical modeling on all scales internal to that separation, systematic uncertainties in the modeling of nonlinear small scales are propagated outward to larger scales. Even in the absence of other limiting factors, this systematic effect alone can necessitate conservative small-scale cuts, resulting in significant losses of information in the tangential shear data vector. We develop a simple linear transformation of the standard galaxy-galaxy observable that removes this nonlocality, which ensures that the cosmological signal contained within the transformed observable is exclusively drawn from well-understood physical scales. This new observable, through its robustness against nonlocality, also enables a significant extension in the range of usable scales in galaxy-galaxy lensing compared to the standard approach in current cosmological analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

The Squeezed Bispectrum from CHIME H I Emission and Planck Cosmic Microwave Background Lensing: Current Sensitivity and Forecasts

Line intensity mapping using atomic hydrogen (H I) has the potential to efficiently map large volumes of the Universe if the signal can be successfully separated from overwhelmingly bright radio foreground emission. This motivates cross correlations, to ascertain the cosmological nature of measured H I fluctuations, and to study their connections with galaxies and the underlying matter density field. However, these same foregrounds render the cross correlation with projected fields such as the lensing of the cosmic microwave background (CMB) difficult. Indeed, the correlated Fourier modes vary slowly along the line of sight and are thus most contaminated by the smooth-spectrum radio continuum foregrounds. In this paper, we implement a method that avoids this issue by attempting to measure the nonlinear gravitational coupling of the small-scale 21 cm power from the Canadian Hydrogen Intensity Mapping Experiment (CHIME) with large-scale Planck CMB lensing. This measurement is a position-dependent power spectrum, i.e., a squeezed integrated bispectrum. Using 94 nights of CHIME data between 1.0 < z < 1.3 and aggressive foreground filtering, we find that the expected signal is 5 times smaller than the current noise. We forecast that incorporating the additional nights of CHIME data already collected would enable a signal-to-noise ratio of 3, without any further improvements in filtering for foreground cleaning.

21cm↗

Design and pre-flight performance of SPIDER 280 GHz receivers

In this work we describe upgrades to the Spider balloon-borne telescope in preparation for its second flight, currently planned for December 2021. The Spider instrument is optimized to search for a primordial B-mode polarization signature in the cosmic microwave background at degree angular scales. During its first flight in 2015, Spider mapped ~10% of the sky at 95 and 150 GHz. The payload for the second Antarctic flight will incorporate three new 280 GHz receivers alongside three refurbished 95- and 150 GHz receivers from Spider's first flight. In this work we discuss the design and characterization of these new receivers, which employ over 1500 feedhorn-coupled transition-edge sensors. We describe pre-flight laboratory measurements of detector properties, and the optical performance of completed receivers. These receivers will map a wide area of the sky at 280 GHz, providing new information on polarized Galactic dust emission that will help to separate it from the cosmological signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recombination smooths the time-signal disrupted by latency in within-host HIV phylogenies

Within-host HIV evolution involves several features that may disrupt standard phylogenetic reconstruction. One important feature is re-activation of latently integrated provirus, which has the potential to disrupt the temporal signal, leading to variation in the branch lengths and apparent evolutionary rates in a tree. Yet, real within-host HIV phylogenies tend to show clear, ladder-like trees structured by the time of sampling. Another important feature is recombination, which violates the fundamental assumption that evolutionary history can be represented by a single bifurcating tree. Thus, recombination complicates the within-host HIV dynamic by mixing genomes and creating evolutionary loop structures that cannot be represented in bifurcating trees. In this paper, we develop a coalescent-based simulator of within-host HIV evolution that includes latency, recombination, and effective population size dynamics that allows us to study the relationship between the true, complex genealogy of within-host HIV evolution, encoded as an Ancestral Recombination Graph (ARG), and the observed phylogenetic tree. To compare our ARG results to the familiar phylogeny format, we calculate the expected bifurcating tree after decomposing the ARG into all unique site trees, their combined distance matrix, and the overall corresponding bifurcating tree. While latency and recombination separately disrupt the phylogenetic signal, remarkably, we find that recombination recovers the temporal signal of within-host HIV evolution caused by latency by mixing fragments of old, latent genomes into the contemporary population. In effect, recombination averages over extant heterogeneity, whether it stems from mixed time-signals or population bottlenecks. Further, we establish that the signals of latency and recombination can be observed in phylogenetic trees despite being an incorrect representation of the true evolutionary history. Using an Approximate Bayesian Computation method, we develop a set of statistical probes to tune our simulation model to nine longitudinally-sampled within-host HIV phylogenies. Because ARGs are exceedingly difficult to infer from real HIV data, our simulation system allows investigating effects of latency, recombination, and population size bottlenecks by matching decomposed ARGs to real data as observed in standard phylogenies.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of Zero-Net-Rate Pumping Tests

Accurately estimating the distribution of aquifer properties is key to understanding contaminant movement in the subsurface. The distribution of aquifer properties is typically addressed using slug or constant-rate well tests, and the pros and cons of these tests are well known. Slug tests are appealing because they avoid removing contaminated water, but their results are affected by well skin and the small volume of displaced water limits the volume of aquifer that can be evaluated. Constant-rate well tests have the disadvantage of requiring disposal of potentially contaminated water, but they can generate properties that are more representative than slug tests, and they can be used to estimate well efficiency and storativity, which are difficult to characterize using slug tests. Periodic pumping tests are appealing because they have many of the advantages and few of the disadvantages of slug and constant-rate well tests. Periodic pumping tests involve cycling the pumping rate with a regular period and measuring the resulting response in monitoring wells. Some of these tests involve imposing a periodic rate on a constant mean rate. However, other tests involve moving water out and back into the well at rates that are balanced so the net rate after each period is zero. Some zero-net-rate (ZNR) well tests use rates that follow a sinusoidal pattern, whereas others use a square wave pattern that switches between a constant rate of pumping and a constant rate of injection to achieve a zero-net rate. ZNR well tests appear to be a useful compromise between slug and constant rate tests, but methods for conducting and analyzing the results from these tests have received limited evaluation. Periodic pumping tests are typically evaluated through recorded pressure responses to a disturbance source. Recent work has demonstrated that the strain field in the vadose zone shows a response to disturbances in the underlying aquifer. Various instrument designs are available that can record vertical and horizontal strain to very precise resolutions (10-9 ε). Measuring the strain in the vadose zone can present lower costs than measuring pressure in a monitoring well, so using strain could improve the resolution of ZNR tests, as well as make these tests potentially cheaper. A ZNR periodic pumping system was constructed and used to perform tests in the Clemson, South Carolina area. The system was designed to pump and inject with a periodic square-wave, so pumping occurs at a constant rate for half the period and is followed by injection at the same rate for half the period resulting in no net gain or loss of water from the aquifer. The system is designed to generate flow rates from 1 to 3.5 gallons per minute (gpm) with a capacity of 875-gallon per half period. Pressure and strain monitoring points are located in the vicinity of the pumping well. A series of 10 ZNR periodic pumping tests were conducted at the field site, with periods ranging from 2 to 540 minutes. Pressure data were collected and recorded in four monitoring wells in various locations around the pumping well. In addition, vertical and horizontal strain and tilt data were recorded in various locations around the pumping well. Traditional aquifer tests, including slug tests and constant-rate pumping tests were conducted at the field site to provide a baseline of aquifer parameter estimates that are compared the results of ZNR tests. Pressure data measured at monitoring wells during ZNR tests were analyzed utilizing an analytical solution (Streltsova, 1988) that assumes a confined aquifer and estimates hydraulic diffusivity and transmissivity using the time lag and amplitude of the pressure signal. The storativity can be separated out from the hydraulic diffusivity using the transmissivity estimate. The time-lag and amplitude of the pressure signals were estimated using a Fourier transform. The time-lag of the primary period of the pressure increases as a linear function of distance from the pumping well, and it increases as the square root of the period of the ZNR test over a range of periods spanning two orders of magnitudes. The first few harmonics follow similar trends, but the higher frequency harmonics diverge from this trend. Strain and tilt data from various instruments in the vadose and saturated zones are periodic during ZNR tests. The time lags of the strain components increase roughly linearly with distance from the well. Many of the time lags of the strain data from the vadose zone are similar to the time lags observed in the pressure data from a similar distance and pumping period. Theoretical experiments were performed to understand how pressure and strain responds to ZNR periodic pumping. The time-lags of the simulated pressure responses match the field data trends. The results were used to validate the Streltsova (1988) solution for periodic pumping to estimate hydraulic diffusivity. Hydraulic diffusivity was estimated to be 1.8 x 10-2 m2s-1 < Dh < 9.0 x 10-2 m2s-1 using pressure data from all the wells during ZNR tests. Transmissivity was estimated to be 0.8 x 10-4 m2s-1 < T < 4.3 x 10-4 m2s-1. Assuming Storativity = T/Dh gives 1.1 x 10-3 < S < 19 x10-3. Transmissivity is used to estimate the hydraulic conductivity, K, by dividing by the assumed aquifer thickness. Two constant-rate pumping tests were conducted and analyzed using two conceptual models: The Hantush (1961) solution was used to analyze data assuming confined conditions and the Neuman (1974) solution was used to analyze data assuming unconfined conditions. The Hantush (1961) solution estimated transmissivity to be 1.6 x 10-4 m2s-1 < T < 1.8 x 10-4 m2s-1 when using data from all the wells. Storativity was estimated to be 4.4 x 10-3 < S < 8.2 x 10-3. Assuming Dh = T/S gives 0.22 x 10-2 m2s-1 < Dh < 3.6 x 10-2 m2s-1. The Neuman (1974) solution estimated transmissivity to be 0.80 x 10-4 m2s-1 < T < 0.84 x 10-4 m2s-1. Total storativity (S + Sy) was estimated to be 22 x 10-3 < S < 110 x 10-3. Storativity excluding the Sy term was estimated to be 2.2 x 10-3 < S < 2.5 x 10-3. Assuming Dh = T/S gives 0.073 x 10-2 m2s-1 < S < 0.36 x 10-2 m2s-1. Two slug tests were performed on the pumping well, PW-2. The Bouwer and Rice (1976) solution for slug tests was used to analyze the data. This solution works for both confined and unconfined conditions, so both conceptual models were covered through the analysis. Hydraulic conductivity was estimated to be 1.95 x 10-6 ms-1 < K < 2.49 x 10-6 ms-1. Statistical comparison show generally no significant difference in the estimates of Dh, K, or S made using ZNR and conventional pumping tests.. However, the total storage estimated by the Neuman (1974) solution for unconfined settings is larger than that estimate using the Streltsove analysis applied to the ZNR tests. This is likely because the Neuman solution considers delayed yield from storage that the water table, whereas the Streltsova (1988) solution assumes confined conditions. The analysis also indicates that there is a statistically significant difference between parameters estimated with conventional slug tests and those measured with either constant-rate pumping tests or ZNR tests. Hydraulic diffusivity is estimated from the time-lag and the distance from the well. The time-lags of the strain data from the vadose zone are similar to the lags of the pressure data from a similar distance. This indicates that hydraulic diffusivities estimated from the strain data measured in the vadose zone would be similar to the estimates from the pressure data measured in the aquifer. There appear to be sign reversals in some of the strain data that were corrected to estimate the time lag. The dissolved oxygen (CO) concentration was measured during several ZNR tests to evaluate the feasibility of using the procedure to increase contaminant degradation kinetics that are related to DO. The results indicate that DO can be increased during the cycling of ZNR tests in some cases.

Smith-Jones, Austin↗

Structure of Diisobutylene Maleic Acid Copolymer (DIBMA) and Its Lipid Particle as a “Stealth” Membrane-Mimetic for Membrane Protein Research

The study of membrane proteins remains challenging, especially in a native membrane environment. Recently, major progress has been made using maleic acid copolymers, such as styrene maleic acid, to purify membrane proteins and study them directly with native lipids associated with the membrane. Additional maleic acid copolymers, such as diisobutylene maleic acid (DIBMA) membrane-mimetic systems, are being developed and found to have improved spectroscopic properties and pH stability. We studied DIBMA and its lipid particles in solution to better understand its assembly, without and with the lipids, to provide an insight regarding how to use it in solution for better membrane extraction. Using small-angle neutron and X-ray scattering (SANS/SAXS), we show that DIBMA organizes into structures of different size scales at various concentrations and ionic strengths. The polymer performed reasonably well under most solvent conditions except in very low concentrations and high-salt conditions that could result in limited interaction with lipids. To explore DIBMA lipid particles as a suitable membrane-mimetic system for neutron scattering studies of membrane proteins, we measured and determined the contrast-matching point of DIBMA to be ~12% (v/v) D 2 O — similar to that of most protiated lipid molecules but distinct from that of regular protiated proteins — providing a natural contrast for separating their neutron scattering signals. Using SANS contrast variation, we demonstrated that the scattering from the whole lipid particle can be annihilated. Further, we determined that a well-defined lipid nanodisc structure with DIBMA was contrast-matched. These results demonstrate that the DIBMA lipid particle is an outstanding “stealth” membrane-mimetic for membrane proteins. The results provide a structural framework for understanding the organization and assembly process of the polymer itself and the lipid molecules. Such an understanding is imperative for structural techniques such as cryo-electron microscopy, nuclear magnetic resonance, small-angle scattering, and other biophysical techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-beam X-ray ptychography using coded probes for rapid non-destructive high resolution imaging of extended samples

Imaging large areas of a sample non-destructively and with high resolution is of great interest for both science and industry. For scanning coherent X-ray diffraction microscopy, i. e., ptychography, the achievable scan area at a given spatial resolution is limited by the coherent photon flux of modern X-ray sources. Multibeam X-ray ptychography can improve the scanning speed by scanning the sample with several parallel mutually incoherent beams, e. g., generated by illuminating multiple focusing optics in parallel by a partially coherent beam. The main difficulty with this scheme is the robust separation of the superimposed signals from the different beams, especially when the beams and the illuminated sample areas are quite similar. We overcome this difficulty by encoding each of the probing beams with its own X-ray phase plate. This helps the algorithm to robustly reconstruct the multibeam data. We compare the coded multibeam scans to uncoded multibeam and single beam scans, demonstrating the enhanced performance on a microchip sample with regular and repeating structures.

47 OTHER INSTRUMENTATION↗

Design of microwave broadband CMOS transmitter and receiver circuits for MIR and ECEI plasma diagnostics

To efficiently determine the plasma electron density fluctuations using the MIR diagnostic technique, a 55–75 GHz 65 nm-CMOS transmitter has been developed where four separate intermediate frequency (IF) signals are up-converted, amplified, and then combined to generate an 8-tone RF output; a broadband 90 nm-CMOS receiver has also been constructed, which consists of an RF-low noise amplifier (LNA), mixer, and IF amplifier. The circuits and their corresponding modules will soon be deployed on the DIII-D and NSTX-U fusion devices. A 110–140 GHz 65 nm-CMOS receiver has also been designed, which is suitable for measuring the deep-core temperature fluctuations in the DIII-D tokamak using the electron cyclotron emission imaging diagnostic system. In addition to the RF-LNA/balun, mixer, and IF amplifier, an LO balun/tripler and driving amplifier are now included in this highly integrated circuit chip. By adopting the microwave and millimeterwave system-on-chip concept in the front-end system design, this paper demonstrates that compact transmitter and receiver modules can be easily built, which, in turn, facilitates array implementation and maintenance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reuniting crystallography with real space: Ab initio structure elucidation with 4D-STEM

Structure elucidation via single-crystal methods has historically lacked experimental access to real-space information, instead relying exclusively on diffraction-space measurements of Bragg reflections. Here we exploit the dual-space imaging power of 4D scanning transmission electron microscopy to meaningfully integrate real-space information into the crystallographic workflow. We show that virtual apertures assembled by segmentation of high-angle annular dark-field images enable i) pixel-by-pixel separation of coherent Bragg signal from clusters of closely spaced nanocrystals and ii) selective extraction of integrated intensities from thinner subregions of individual specimens, facilitating retroactive tuning of multiple scattering artifacts. This strategy empowers us to simply pick and choose whichever nanoscale regions of interest generate the highest-quality diffraction patterns, allowing us to solve several independent structures of the metal-organic framework UiO-66 from specimens whose agglomerated morphology proved intractable for conventional microcrystal electron diffraction. Our method is compatible with both rotational and serial approaches to data processing, ultimately divulging the first scanning nanobeam electron diffraction structures determined by direct methods at subangstrom resolution.

Saha, Ambarneil↗

Bayesian forecasts for dark matter substructure searches with mock pulsar timing data

Dark matter substructure, such as primordial black holes (PBHs) and axion miniclusters, can induce phase shifts in pulsar timing arrays (PTAs) measurements due to gravitational effects. In order to gain a more realistic forecast for the detectability of such models of dark matter with PTAs, we propose a Bayesian inference framework to search for phase shifts generated by PBHs and perform the analysis on mock PTA data. Furthermore, for most PBH masses the constraints on the dark matter abundance agree with previous (frequentist) analyses (without mock data) to $\mathcal{O}$(1) factors. This further motivates a dedicated search for PBHs (and dense small scale structures) in the mass range from 10 -8 M ⊙ to well above 10 2 M ⊙ with the Square Kilometer Array. Moreover, with a more optimistic set of timing parameters, future PTAs are predicted to constrain PBHs down to 10 -11 M ⊙ . Lastly, we discuss the impact of backgrounds, such as Supermassive Black Hole Mergers, on detection prospects, suggesting a future program to separate a dark matter signal from other astrophysical sources.

79 ASTRONOMY AND ASTROPHYSICS↗