Search NASA⌕ Search

SEARCH · Search NASA

Results for “silver activation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

STS-110 Flight Day 6 Highlights

On the sixth day of the STS-110 mission, Mission Specialists Jerry Ross and Lee Morin are seen in the second extravehicular activity (EVA) of this mission to the International Space Station (ISS). The video opens with the two astronauts preparing for the EVA, which will be Ross' eighth, thereby making him the most experienced space-walker in history. This pair of astronauts has been dubbed the Silver Team, largely because they both have grandchildren. As Ross and Morin prepare for the EVA by breathing pure oxygen and experiencing reduced pressure, Mission Specialist Ellen Ochoa maneuvers the robotic arm towards the hatch of the Space Shuttle Atlantis. There is video footage of the astronauts exiting the hatch and preparing their tools and work areas. During this EVA the astronauts will install two tripod-like struts, which will serve as structural attachments between the S-0 truss segment and the Destiny Laboratory Module. While the construction takes place, helmet mounted cameras on the spacesuits provide live video of the astronauts at work, most often using a pistol grip tool used as an electric ratcheting-type drill to loosen and tighten bolts. Following the installation of the struts, Ross and Morin remove the draglinks and keelpins that had functioned to hold the S0 truss structure securely in Atlantis' payload bay during the launch sequence of the mission. They move these to temporary storage positions, bolted on the outside of the ISS. They then install an umbilical system that will provide power to the Mobile Transporter (MT).

Source record↗

A high power lithium thionyl chloride battery for space applications

A high power, 28 V, 330 A h, active lithium thionyl chloride battery has been developed for use as main and payload power sources on an expendable launch vehicle. Nine prismatic cells, along with the required electrical components and a built-in heater system, are efficiently packaged resulting in significant weight savings over presently used silver-zinc batteries. The high rate capability is achieved by designing the cells with a large electrochemical surface area and impregnating an electrocatalyst, polymeric phthalocyanine, into the carbon cathodes. Passivation effects are reduced with the addition of sulfur dioxide into the thionyl chloride electrolyte solution. The results of conducting a detailed thermal analysis are utilized to establish the heater design parameters and the thermal insulation requirements of the battery. An analysis of cell internal pressure and vent characteristics clearly illustrates the margins of safety under different operating conditions. Performance of fresh cells is discussed using polarization scan and discharge data at different rates and temperatures. Self-discharge rate is estimated based upon test results on cells after storage. Results of testing a complete prototype battery are described.

Shah, Pinakin M.↗

Adhesion of metals to a clean iron surface studied with LEED and Auger emission spectroscopy.

Discussion of the results of adhesion experiments conducted with various metals contacting a clean iron surface. The metals included gold, silver, nickel, platinum, lead, tantalum, aluminum, and cobalt. Some of the metals were examined with oxygen present on their surface as well as in the clean state. The results indicate that, with the various metals contacting iron, the cohesively weaker will adhere and transfer to the cohesively stronger. The chemical activity of the metal also influenced the adhesive forces measured. With oxygen present on the metal surface, the adhesive forces measured could be correlated with the binding energy of the metal to oxygen.

Buckley, D. H.↗

Photon degradation effects in terrestrial solar cells

Reduction in cell output was observed in N(+)/P cells upon exposure to illumination or upon the application of a sufficiently high forward bias. Conversely, an enhancement in output was observed when P(+)/N cells were illuminated. Investigations performed on N(+)/P cells indicated that a recombination center located at E sub c - 0.37 eV in the forbidden band was responsible for the loss in output. The center was electrically inactive in its ground state but was activated either by raising the minority carrier quasi-Fermi level sufficiently close to the latent center energy level in the band gap, or by direct excitation of electrons from the valence band to the latent center level. The center was identified as a complex of a lattice defect and a silver atom or cluster of atoms.

Weizer, V. G.↗

Red Plague Control Plan (RPCP)

SCOPE: Prescribes the minimum requirements for the control of cuprous / cupric oxide corrosion (a.k.a. Red Plague) of silver-coated copper wire, cable, and harness assemblies. PURPOSE: Targeted for applications where exposure to assembly processes, environmental conditions, and contamination may promote the development of cuprous / cupric oxide corrosion (a.k.a. Red Plague) in silver-coated copper wire, cable, and harness assemblies. Does not exclude any alternate or contractor-proprietary documents or processes that meet or exceed the baseline of requirements established by this document. Use of alternate or contractor-proprietary documents or processes shall require review and prior approval of the procuring NASA activity.

Cooke, Robert W.↗

The Stellar X-ray Polarimeter - A focal plane polarimeter for the Spectrum X-Gamma mission

This paper describes an X-ray polarimeter that will be flown on the Spectrum X-Gamma mission. The instrument exploits three distinct physical processes to measure polarization: Bragg reflection from a graphite crystal, Thomson scattering from a metallic lithium target, and photoemission from a cesium iodide photocathode. These three methods allow polarization measurements over an energy band from 0.3 to 12 keV. The polarimeter will make possible sensitive measurements of several hundred known X-ray sources. X-ray polarization measurements will make it possible to constrain the geometry of gas flow in X-ray binaries, identify nonthermal emission in supernova remnants, test current models for X-ray emission in radio pulsars, determine the radiation mechanisms in active galactic nuclei, and search for inertial frame dragging (Lense-Thirring effect) around the putative black hole in Cygnus X-1.

Kaaret, P.↗

Characterization of metal oxide absorbents for regenerative carbon dioxide and water vapor removal for advanced portable life support systems

Characterization of the performance of a silver-oxide-based absorbent in terms of its ability to remove both gaseous CO2 and water vapor in an astronaut portable life support systems (PLSS) is discussed. Attention is focused on regeneration of the absorbent from the carbonite state of the oxide state, preconditioning of the absorbent using a humidified gas stream, and absorption breakthrough testing. Based on the results of bench-scale experiments, a test plan is carried out to further characterize the silver-oxide-based absorbent on a larger scale; it calls for examination of the absorbent in both an adiabatic packed bed and a near-isothermal cooled bed configuration. It is demonstrated that the tested absorbent can be utilized in a way that removes substantial amounts of CO2 and water vapor during an 8-hour extravehicular activity mission, and that applying the absorbent to PLSS applications can simplify the ventilation loop.

Kast, Timothy P.↗

Experimental results on atomic oxygen corrosion of silver

The results of an experimental study of the reaction kinetics of silver with atomic oxygen in 10 degree increments over the temperature range of 0 to 70 C is reported. The silver specimens, of the order of 10,000 A in thickness, were prepared by thermal evaporation onto 3 inch diameter polished silicon wafers. There were later sliced into pieces having surface areas of the order of 1/4 to 1/2 square inch. Atomic oxygen was generated by a gas discharge in a commercial plasmod asher operating in the megahertz frequency range. The sample temperature within the chamber was controlled by means of a thermoelectric unit. Exposure of the silver specimens to atomic oxygen was incremental, with oxide film thickness measurements being carried out between exposures by means of an automated ellipsometer. For the early growth phase, the data can be described satisfactorily by a logarithmic growth law: the oxide film thickness increases as the logarithm of the exposure time. Furthermore, the oxidation process is thermally activated, the rate increasing with increasing temperature. However, the empirical activation energy parameter deduced from Arrhenius plots is quite low, being of the order of 0.1 eV.

Fromhold, Albert T.↗

Microbiological Characterization and Concerns of the International Space Station Internal Active Thermal Control System

Since January 1999, the chemical the International Space Station Thermal Control System (IATCS) and microbial state of (ISS) Internal Active fluid has been monitored by analysis of samples returned to Earth. Key chemical parameters have changed over time, including a drop in pH from the specified 9.5 +/- 0.5 ta = 58.4, an increase in the level of total inorganic carbon (TIC), total organic carbon (TOC) and dissolved nickel (Ni) in the fluid, and a decrease in the phosphate (PO,) level. In addition, silver (AS) ion levels in the fluid decreased rapidly as Ag deposited on internal metallic surfaces of the system. The lack of available Ag ions coupled with changes in the fluid chemistry has resulted in a favorable environment for microbial growth. Counts of heterotrophic bacteria have increased from less than 10 colony-forming units (CFUs)/l00 mL to l0(exp 6) to l0(exp 7) CFUs/100 mL. The increase of the microbial population is of concern because uncontrolled microbiological growth in the IATCS can contribute to deterioration in the performance of critical components within the system and potentially impact human health if opportunistic pathogens become established and escape into the cabin atmosphere. Micro-organisms can potentially degrade the coolant chemistry; attach to surfaces and form biofilms; lead to biofouling of filters, tubing, and pumps; decrease flow rates; reduce heat transfer; initiate and accelerate corrosion; and enhance mineral scale formation. The micro- biological data from the ISS IATCS fluid, and approaches to addressing the concerns, are summarized in this paper.

Roman, Monsi C.↗

The high energy transmission grating spectrometer for AXAF

Attention is given to a high energy transmission grating spectrometer that operates over the range 0.4-8 keV, giving resolving powers of 100-1000 and effective areas of 10-200 sq cm. The instrument, which is part of the MIT high resolution X-ray spectroscopy investigation, consists of a single array of grating facets of two types: medium energy gratings of 0.6-micron period, 0.5-micron thick silver mounted behind the outer three AXAF mirrors, and high energy gratings of 0.2-micron period, 1.0-micron thick gold mounted behind the inner three mirrors. The gratings are oriented so as to correct for coma and so that the medium and high energy spectra form a shallow 'X' at the AXAF focal plane. Likely targets include normal stars, binary X-ray sources, active galactic nuclei and quasars. The HETGS can also be used to give moderate resolution spectra of slightly extended sources and monochromatic images of sources with strong lines, such as supernova remnants in nearby galaxies.

Canizares, C. R.↗

A deficiency in DNA repair and DNA-PKcs expression in the radiosensitive BALB/c mouse

We have studied the efficiency of DNA double strand break (DSB) rejoining in primary cells from mouse strains that show large differences in in vivo radiosensitivity and tumor susceptibility. Cells from radiosensitive, cancer-prone BALB/c mice showed inefficient end joining of gamma ray-induced DSBs as compared with cells from all of the other commonly used strains and F1 hybrids of C57BL/6 and BALB/c mice. The BALB/c repair phenotype was accompanied by a significantly reduced expression level of DNA-PKcs protein as well as a lowered DNA-PK activity level as compared with the other strains. In conjunction with published reports, these data suggest that natural genetic variation in nonhomologous end joining processes may have a significant impact on the in vivo radiation response of mice.

Non-NASA Center↗

Evaluation of Iodine and Silver as Biocides for Potable Water in Human Missions beyond Low Earth Orbit

Chemical biocides play an important role in potable water storage and distribution systems. They provide protection against microbial growth that can negatively impact efficient water transport and crew health. Molecular iodine and ionic silver have been used on the International Space Station for decades. Future orbiting and surface habitats will have potable water systems that will require reliable potable water storage and challenging transport schemes during daily operations with potentially lengthy and repeated periods of non-use. Based on a review of literature, experimental data, and flight data this paper categorizes the advantages and disadvantages of the two heritage biocides on ISS: iodine and silver. The history of biocide practices on ISS is compared to requirements of future human missions beyond low Earth Orbit. The upstream water quality supply and downstream water uses are defined with respect to the two biocides. The methods of injection and removal of the two biocides are compared for a range of downstream water uses including drinking water, hygiene water, technical water, oxygen generation water, and extravehicular activity water. The paper provides mission planners with a technical and engineering assessment of the two biocides and identifies gaps in knowledge and on-orbit experiences.

Dean Muirhead↗

Study of CO2 sorbents for extravehicular activity

Portable life support equipment was studied for meeting the requirements of extravehicular activities. Previous studies indicate that the most promising method for performing the CO2 removal function removal function were metallic oxides and/or metallic hydroxides. Mgo, Ag2, and Zno metallic oxides and Mg(OH)2 and Zn(OH)2 metallic hydroxides were studied, by measuring sorption and regeneration properties of each material. The hydroxides of Mg and Zn were not regenerable and the zinc oxide compounds showed no stable form. A silver oxide formulation was developed which rapidly absorbs approximately 95% of its 0.19 Kg CO2 Kg oxide and has shown no sorption or structural degeneration through 22 regenerations. It is recommended that the basic formula be further developed and tested in large-scale beds under simulated conditions.

Colombo, G. V.↗

Design and fabrication of a skin stringer discrete tube actively cooled structural panel

The design optimization and practical implementation of actively cooled structural panel concepts was investigated. The desired actively cooled structural panel consisted of the cooled skin and a substructure. The primary load carrying components were fabricated from 2024-T3 aliminum alloy. The 3003-H14 coolant passage tubing was chosen because of its excellent corrosion resistance, workability needed to obtain the desired cross sectional shape, and strength. The Epon 951 adhesive was selected for its excellent structural properties and is the thinnest of available films, 0.064 mm. The Eccobond 58C silver filled epoxy was chosen because of its high thermal conductivity, and the alumina filled Epon 828 was chosen for structural and expansion characteristics.

Anthony, F. M.↗

Development of a Pressure-Fed Rocket Engine Using Hydrogen Peroxide and JP-8

A pressure-fed rocket engine using hydrogen peroxide and JP-8 was designed and demonstrated for upper stage space transportation applications. The engine utilizes silver plated screen catalyst to decompose 85% hydrogen peroxide (by weight). The decomposed high-temperature gas causes the JP-8 to auto-ignite and undergo chemical reaction. An ablative chamber using silica phenolic was used as the combustion chamber. The present effort includes catalyst development, injector evaluation, and chamber char and erosion characterization. Wagonwheel-type distribution and support plates were used in the catalyst bed design to reduce pressure drop, to increase active area, and to avoid flow channeling. Various fuel injection and mixing approaches were investigated and the combustion efficiency was in the range from 89 to 98%, depending on injector design and operating conditions. Fuel film cooling, up to 40% of the total fuel flow, was found to be ineffective with the current engine configuration. A ring injector was selected because of the satisfactory performance and its low cost. The char and erosion rates were determined through hot-fire tests. The char depth was found to be a function of axial distance, which was related to the progress of chemical reaction. Correlation of the char and erosion rates was developed as a design database for future applications,

Wu, P.-K.↗

Elevated breast cancer risk in irradiated BALB/c mice associates with unique functional polymorphism of the Prkdc (DNA-dependent protein kinase catalytic subunit) gene

Female BALB/c mice are unusually radiosensitive and more susceptible than C57BL/6 and other tested inbred mice to ionizing radiation (IR)-induced mammary tumors. This breast cancer susceptibility is correlated with elevated susceptibility for mammary cell transformation and genomic instability following irradiation. In this study, we report the identification of two BALB/c strain-specific polymorphisms in the coding region of Prkdc, the gene encoding the DNA-dependent protein kinase catalytic subunit, which is known to be involved in DNA double-stranded break repair and post-IR signal transduction. First, we identified an A --> G transition at base 11530 resulting in a Met --> Val conversion at codon 3844 (M3844V) in the phosphatidylinositol 3-kinase domain upstream of the scid mutation (Y4046X). Second, we identified a C --> T transition at base 6418 resulting in an Arg --> Cys conversion at codon 2140 (R2140C) downstream of the putative leucine zipper domain. This unique PrkdcBALB variant gene is shown to be associated with decreased DNA-dependent protein kinase catalytic subunit activity and with increased susceptibility to IR-induced genomic instability in primary mammary epithelial cells. The data provide the first evidence that naturally arising allelic variation in a mouse DNA damage response gene may associate with IR response and breast cancer risk.

Non-NASA Center↗

Initiation and elongation of lateral roots in Lactuca sativa

Lactuca sativa cv. Baijianye seedlings do not normally produce lateral roots, but removal of the root tip or application of auxin, especially indole-butyric acid, triggered the formation of lateral roots. Primordia initiated within 9 h and were fully developed after 24 h by activating the pericycle cells opposite the xylem pole. The pericycle cells divided asymmetrically into short and long cells. The short cells divided further to form primordia. The effect of root tip removal and auxin application was reversed by 6-benzylaminopurine at concentrations >10(-8) M. The cytokinin oxidase inhibitor N1-(2chloro4pyridyl)-N2-phenylurea also suppressed auxin-induced lateral rooting. The elongation of primary roots was promoted by L-alpha-(2-aminoethoxyvinyl) glycine and silver ions, but only the latter enhanced elongation of lateral roots. The data indicate that the induction of lateral roots is controlled by basipetally moving cytokinin and acropetally moving auxin. Lateral roots appear to not produce ethylene.

NASA Discipline Plant Biology↗

Impedance of silver oxide-zinc cells

Over 100 sealed AgO-Zn cells were subjected to prolonged periods of storage over a range of temperatures and storage modes including open circuit, trickle charge, and float charge. Impedances of these cells were monitored throughout, and at the end of the storage period their transient voltage characteristics were observed at the onset of discharge. Results revealed that the impedances of these cells tended to increase with storage time; the magnitude of the impedance rise was dependent primarily on temperature and to a lesser degree on storage mode. Typical values for 50 A-hr cells were usually less than 100 mohm immediately after activation and from 1 to 30 ohm after 6-10 months of storage. Transient voltages of these cells droped sharply during the first msec of discharge and then rose to a stablized value during the following few seconds. The magnitude of the initial drop and the stabilized voltage values were found to be related to impedance but not in a linear manner. The magnitude and duration of the low transient voltages may be unacceptable in some applications of these cells. The impedance variations are attributed to changes occurring at the positive electrode.

Frank, H. A.↗