Search NASA⌕ Search

SEARCH · Search NASA

Results for “smart building controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Development of Wireless Power Technology for Use in Electrochromic Window Retrofit Applications

Electrochromic (EC) windows, often referred to as smart windows, have the ability to adjust their tint in response to electrical signals, thereby controlling the amount of sunlight and heat entering a building. This dynamic modulation can lead to significant energy savings by reducing the reliance on artificial lighting and minimizing the load on heating, ventilation, and air conditioning (HVAC) systems. However, the widespread adoption of electrochromic window technology, especially in existing buildings, faces challenges, particularly concerning the installation cost associated with the need for electrical wiring to power and control the EC glass (tinting). In this project, GuRu Wireless demonstrated that it’s mmWave-based wireless power energy transfer technology can provide the necessary power for operation of electrochromic windows, wirelessly, and address the wiring challenges of electrochromic windows in retrofit applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Probing Dynamic Phase Changes in Electrochemical Systems with Cryogenic and in Situ Analytical Electron Microscopy (Final Technical Report)

In this project, we focus on the advancement of our newly developed, unique in situ and cryogenic analytical electron microscopy (AEM) techniques and the development of additional high-end capabilities to quantitatively elucidate the mechanisms of resistive state changes in solid-state electrochemical materials for non-volatile, neuromorphic memory. The objectives of the proposed research are (1) to characterize and elucidate the mechanisms by which electronic state changes occur in various solid-state devices to build guiding principles for electrochemically activated smart materials; (2) to advance our understanding of such mechanisms by coupling cryogenic and in situ techniques to control kinetics of the observed mechanisms while mitigating probe-induced damage; and (3) to utilize additional advanced techniques including electron-beam induced current and quantum mechanical simulations in order to identify the underlying fundamental science of such processes, including roles of defect formation and its effect on phase nucleation, as well as dynamics of these processes in the electrochemical systems at the nanometer scale.

25 ENERGY STORAGE↗

A Real-time Agent Based Optimization and Control Approach for Residential Building Heating Ventilation and Air Conditioning Systems

The prevalence of the loT (Internet of Things) is fostering the development of new control options and decision making that was not previously available. This is creating a wealth of opportunities for real-time control approaches and systems that can optimize for a common goal. This paper presents a smart residential neighborhood with optimization at the residential level utilizing a system of agents. The optimization utilizes information and modeling to optimize variable speed HVAC real-time operation in actual residential buildings. Data is presented showing the performance of the optimization and conclusions are drawn on next steps for development.

Hall, Joni↗

Benefits of Dual Fuel Heat Pump Grid-responsive Control: A Model-based Control Optimization Approach Using Building and Equipment Co-simulation

Conventional dual fuel heat pumps lack the intelligent control mechanisms to efficiently manage the switch between heat pump and furnace, leading to sub-optimal energy usage and, in some cases, increased operating costs. To resolve this gap, this study applies optimized control on hybrid heat pumps. With a focus on equipment control strategies, we compare the performances of five spacing heating equipment, including a conventional heat pump (HP), a conventional furnace, a dual fuel heat pump (DFHP) with conventional control, a dual fuel heat pump with smart control, and a novel seamlessly fuel flexible heat pump (SFFHP). While DFHP runs on either gas or electricity at any given moment, SFFHP concurrently consumes gas and electricity by continuously optimizing the proportion of each. In this research, a co-simulation framework is developed by integrating a building envelope model with a physics-based heat pump simulation model to analyze the benefits of grid-responsive controls of DFHP and SFFHP. The model-based optimal controls adjust the operation of the heat pump and gas furnace based on utility price signals and marginal grid emission to minimize utility cost and CO 2 emissions for multiple climate zones, different utility tariffs, and marginal grid emission scenarios. Case studies in Chicago and Los Angeles demonstrate that SFFHP and DFHP, with model-based optimal control, can deliver significant reductions in peak demand, utility cost, and CO 2 emission. In Chicago, SFFHP and smart controlled DFHP yield up to 64.7% and 61.7% utility cost reduction and up to 15.7% and 8.5% CO 2 emission reduction compared to the gas furnace. In Los Angeles, SFFHP and smart controlled DFHP achieve up to 43.6% and 40.1% utility cost reduction and up to 13.8% and 14.1% CO2 emission reduction compared to conventional heat pumps. In conclusion, by leveraging the fuel flexibility nature of dual fuel heat pumps, the model-based control optimization approach makes dual fuel heat pump an attractive option for demand response programs.

Control↗

Impact of Connected Communities

Buildings account for 35% of CO 2 emissions and almost 40% of the United States’ energy use. High-performance homes and neighborhoods play an important role in supporting efforts to decarbonize the US power system by 2035. Significant reductions in CO 2 emissions within the residential sector can be realized through electrification of loads paired with the flexibility created by leveraging smart Internet of Things (IoT) capabilities to shift energy use based on grid signals, thus improving generation/distribution efficiency and maximizing the use of renewable generation capacity. All of this can be achieved while allowing smart home appliances and equipment to meet homeowner needs – including reducing power bills - while optimizing operation in conjunction with the grid using novel control techniques. The Grid-Interactive Efficient Buildings Roadmap by the US Department of Energy’s (DOE’s) Building Technologies Office (BTO) notes that implementing grid-interactive efficient building (GEB) technology has the potential to reduce CO 2 emissions by 80 million tons/year—roughly equivalent to 17 million cars. To achieve this vision, the US Department of Energy’s Oak Ridge National Laboratory (ORNL)—in collaboration with Southern Company Research & Development, Alabama Power, Georgia Power, BTO and the US DOE’s Office of Electricity (OE) —is developing and demonstrating novel connected communities at two locations. Southern Company in turn engaged with industry partners, including design firms, residential developers, and residential HVAC and appliance manufacturers because their participation would be critical to the success of the initial research project, as well as the future scaling to the Southern Company service territory and beyond. Impacts of the Connected Communities projects in Alabama and Georgia are outlined including: energy, grid services and data management learnings; homeowner feedback; vendor engagement; adoption by utilities; technical, policy and business model challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Building Start (SBS) (CRADA 480)

The idea of Smart Building Start (SBS) is to manage the on/off scheduling of HVAC equipment in buildings in an optimal way in order to achieve comfort conditions at the designated times with the minimal use of energy. This concept is also known as Optimal Start and it has typically been used in buildings to start up equipment based on predictions made for a representative (or average) zone in a building. This means that zones that could have waited longer to receive conditioned air are activated too early leading to unnecessary energy loss. The approach proposed in this project is to develop and implement a distributed version of optimal start that will consider the individual requirements of all treated zones. The developed control strategy will enable smart start of the central plant as well as further localized control over each individual zone by means of setpoint adjustment so that zones are not conditioned too early thereby reducing energy use compared to the current state of the art. This project is a collaboration between PNNL and Verdicity with the goal being to bring the research concept of SBS to commercialization. The SBS algorithm(s) will be implemented and hosted on the PNNL-developed open-platform VOLTTRON which will accelerate bringing the research to practice. It is anticipated that this project will lead to new IP surrounding the algorithm and its decentralized deployment. The project will also further demonstrate the success of VOLTRON as a flexible platform for implementation of innovative algorithms for improving energy efficiency in buildings. Previous studies on smart building start carried out by PNNL have indicated potential energy savings on the order of 10-15% for multi-zone buildings compared to conventional strategies. Verdicity currently has a number of customers who can benefit from the use of this technology. PNNL will work with Verdicity to identify any key gaps in the integrated software and jointly work to enhance and customize it for Verdicity and to integrate it with their existing products for use at their customers’ sites. The proposed work will help previously funded Federal research and development technology investments find their way into a viable commercial market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Emerging Plug Load Management Technologies that Save Energy and Time

This fact sheet introduces two emerging technologies that could streamline plug load management (PLM) for increased energy savings for building owners: learning behavior algorithms (LBA) and automatic and dynamic load detection (ADLD). Plug loads are responsible for 47% of the energy consumed in commercial buildings, yet their distributed and ever-changing nature makes them challenging to manage. PLM systems exist today that use smart plugs to meter and control devices at the outlet level, but their uptake has been relatively slow in part because of the significant labor required for installation and maintenance. LBA and ADLD may address these challenges and provide additional energy efficiency and nonenergy benefits.

Plug and process loads, PPL, plug loads, plug load↗

Department of Energy/IDEA: More best-practices research

This article continues the overview of the U.S. Department of Energy and IDEA collaboration by highlighting additional case studies that demonstrate innovative engineering approaches in district energy systems. It focuses on how campuses are improving efficiency, integrating advanced technologies, and reducing energy use and emissions through data-driven strategies. The University of Cincinnati is featured for its highly efficient chilled water system, using advanced algorithms and upgraded “smart chillers” to optimize performance, reduce energy consumption, and lower costs. Wake Forest University emphasizes a data-informed modernization process, using system optimization and targeted building improvements to significantly boost efficiency and reduce overall energy use. Arizona Western College showcases creative solutions to extreme cooling demands, including system redesign, smart controls, and thermal storage to improve reliability and cut peak energy costs. Overall, the article demonstrates that combining innovative engineering, real-time data analysis, and system optimization can significantly enhance performance, reduce emissions, and deliver cost savings in district energy systems.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Coupled Heat Power Operation of Smart Buildings via Modular Pumped Hydro Storage

In the United States, building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings’ energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low-grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high-efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground level. This unique design eliminates the geographical limitation associated with the existing state-of-the-art energy storage technologies. It is easy to be scaled for building level, community level, and grid level applications. By using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g., from thermal storage, combined cooling, heat and power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Here, several groups of comparison experiments have been conducted, and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Infrared-Fused Vision-Based Thermoregulation Performance Estimation for Personal Thermal Comfort-Driven HVAC System Controls

Thermal comfort is one of the primary factors influencing occupant health, well-being, and productivity in buildings. Existing thermal comfort systems require occupants to frequently communicate their comfort vote via a survey which is impractical as a long-term solution. Here, we present a novel thermal infrared-fused computer vision sensing method to capture thermoregulation performance in a non-intrusive and non-invasive manner. In this method, we align thermal and visible images, detect facial segments (i.e., nose, eyes, face boundary), and accordingly read the temperatures from the appropriate coordinates in the thermal image. We focus on the human face since it is often clearly visible to cameras and is not merged into a hot background (unlike hands). We use a regularized Gaussian Mixture model to track the thermoregulation changes over time and apply a heuristic algorithm to extract hot and cold indices. We present a personalized and a generalized comfort modeling method, selected based on the availability of the occupant historical indices measurements in a neutral environment, and use the time-series of the hot and cold indices to define corrections to HVAC system operations in the form of setpoint constraints. To evaluate the efficacy of our proposed approach in responding to thermal stimuli, we designed a series of controlled experiments to simulate exposure to cold and hot environments. While applying personalized modeling showed an acceptable average accuracy of 91.3%, the generalized model’s average accuracy was only 65.2%. This shows the importance of having access to physiological records in modeling and assessing comfort. We also found that individual differences should be considered in selecting the cooling and heating rates when some knowledge of the occupant’s overall thermal preference is available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating a Microgrid Controller with a Local OpenADR Server

When military microgrids isolate themselves from the main electrical grid, they must locally balance electricity supply and demand. Since local generation may be limited, the current strategy is to shed all but the most critical loads by tripping smart circuit breakers, which must then be reset manually (e.g., ESTCP project EW-201350). This strategy is typically applied at the building level, meaning that entire buildings housing mission critical activities must be excluded from any load management, while those considered non-critical may lose service entirely. The remotely controlled switchgear needed to manage load in this way is very expensive ($\$30,000$-$\$50,000$ per building). While effective at shedding load, this strategy disrupts installation operation and risks damaging equipment during both disconnection and re-energization. With the goals of lowering costs, protecting equipment, and enhancing the agility of DoD microgrids, this report demonstrates the use of cybersecure automated demand response (ADR) technology to manage microgrid loads during grid-independent (a.k.a. "islanded") operation. This automated approach achieves load shedding and shifting through communication signals sent to equipment controllers rather than by cutting off the flow of electricity within the microgrid itself. Because it operates only on the base network, with no connection to external entities, this strategy avoids the main cybersecurity concern raised by past applications of ADR on military bases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Reinforcement Learning Based Smart Water Heater Control for Reducing Electricity Consumption and Carbon Emission

Water heating is the third largest electricity consumer in U.S. households, after space heating and cooling. Thus, water heaters represent a significant potential for reducing electricity consumption and associated CO2 emissions of residential buildings. To this end, this study proposes a model-free deep reinforcement learning (RL) approach that aims to minimize the electricity consumption and the CO2 emissions of a heat pump water heater without affecting user comfort. In this approach, a set of RL agents focusing on either electricity saving or emission reduction, with different look ahead periods, were trained using the deep Q-networks (DQN) algorithm and their performance was tested on different hot water usage and Marginal Operating Emissions Rate (MOER) profiles. The testing results showed that the RL agents that focus on electricity saving can save electricity in the range of 12–22% by operating the water heater with maximum heat pump efficiency and minimum electric element utilization. On the other hand, the RL agents that focus on emission reduction reduced emissions in the range of 18–37% by making use of the variable MOER values. These RL agents used the heat pump and/or an element when the MOER values are low due to the availability of renewable energy sources (e.g., solar and wind) and mostly avoided the periods of carbon-intensive periods. Overall, these results showed that the proposed RL approach can help minimize the electricity consumption and the CO2 emissions of a heat pump water heater without having any prior knowledge about the device.

Amasyali, Kadir↗

Controlling distributed energy resources via deep reinforcement learning for load flexibility and energy efficiency

Behind-the-meter distributed energy resources (DERs), including building solar photovoltaic (PV) technology and electric battery storage, are increasingly being considered as solutions to support carbon reduction goals and increase grid reliability and resiliency. However, dynamic control of these resources in concert with traditional building loads, to effect efficiency and demand flexibility, is not yet commonplace in commercial control products. Traditional rule-based control algorithms do not offer integrated closed-loop control to optimize across systems, and most often, PV and battery systems are operated for energy arbitrage and demand charge management, and not for the provision of grid services. More advanced control approaches, such as MPC control have not been widely adopted in industry because they require significant expertise to develop and deploy. Recent advances in deep reinforcement learning (DRL) offer a promising option to optimize the operation of DER systems and building loads with reduced setup effort. However, there are limited studies that evaluate the efficacy of these methods to control multiple building subsystems simultaneously. Additionally, most of the research has been conducted in simulated environments as opposed to real buildings. This paper proposes a DRL approach that uses a deep deterministic policy gradient algorithm for integrated control of HVAC and electric battery storage systems in the presence of on-site PV generation. The DRL algorithm, trained on synthetic data, was deployed in a physical test building and evaluated against a baseline that uses the current best-in-class rule-based control strategies. Performance in delivering energy efficiency, load shift, and load shed was tested using price-based signals. The results showed that the DRL-based controller can produce cost savings of up to 39.6% as compared to the baseline controller, while maintaining similar thermal comfort in the building. The project team has also integrated the simulation components developed during this work as an OpenAIGym environment and made it publicly available so that prospective DRL researchers can leverage this environment to evaluate alternate DRL algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Open Building Operating System: An Open-Source Grid Responsive Control Platform for Buildings

Grid-interactive efficient buildings (GEBs) with flexible loads are a promising method to decarbonize buildings, shift loads during peak hours, and lower energy use and electricity costs. Despite the promising benefits of GEBs, automation systems that manage flexible loads in response to energy prices or other grid signals are still uncommon in small and medium commercial buildings. Recent literature demonstrates such control solutions, but they often rely on custom integrations lacking the tools and drivers needed for scalability. To address these gaps, our team has created a fully open-source software stack capable of integrating heterogeneous flexible building loads and implementing integrated portable control applications called the Open Building Operating System (OpenBOS). The software can be deployed over existing control architecture with a small capital cost. OpenBOS leverages semantic models, which have been the subject of recent investigations to facilitate application portability. The use of semantic data reduces the labor and expense required to deploy and update smart control applications, increasing scalability. In this paper, the semantic modeling schema "Brick" was used, but the proposed approach can also be applied to ASHRAE standard 223P, when released. This paper describes the methodology and software components of OpenBOS and demonstrates its functionality with a rule-based demand flexibility control application configured using a semantic model. This application was tested at a real building in NY that uses a dual-fuel heating system made up of five ductless heat pump mini-splits and a central furnace serving a single zone. The demonstration reduced electricity costs at the site by 27%, demand during a shed event by 49%, and furnace usage by 35%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cosimulating Integrated Energy Systems With Heterogeneous Digital Twins: Matching a Connected World

Energy system integration promises in-creased resiliency and the unlocking of synergies, while also contributing to our goal of decarbonization. It is enabled by both old and new technologies, glued together with data and digital services. Hydrolyzers, heat pumps, distributed renewable generation, smart buildings, and the digital grid edge are all currently the subject of integration with the power system and the energy sector at large. To plan and operate such a multidisciplinary and multisectoral system properly, insight, tools, and expertise are all needed. Further, this is exactly where the state of the art fails to deliver: tools for integrated energy systems (IESs) are still in their infancy, and many times, even academia treats these sectors separately, producing experts in each of them but not across.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spatially Adaptive Tunable Lighting Control System with Expanded Wellness and Energy Saving Benefits

Lighting design is becoming increasingly complex, including active dimming for energy savings and spectral tuning for human wellbeing. Modern commercial lighting control systems are already difficult to use, and maintain, and even with so-called Smart Lighting, optimizing light settings is rapidly exceeding the capabilities of direct human control, limiting the adoption of lighting control systems. The growing importance of Occupancy Centric Controls (OCC) for advanced building management systems can be applied to the development of autonomous lighting system controls needed to drive the adoption of advanced lighting controls for improved adaptive “sculpted illumination” for both greater energy savings and broader human wellbeing perspectives. This project, led by Rensselaer Polytechnic Institute, entitled “Spatially adaptive tunable lighting control system with expanded wellness and energy saving benefits” will develop and test an entirely new platform for automated optimized lighting design and control that requires little or no human engagement, yet contours lighting profiles automatically to minimize lighting energy use. We call this approach to lighting control “dynamic light sculpting” since the right amount of illumination is automatically delivered to occupants in real time. Since the system uses new, privacy-preserving occupant position and pose detection technologies developed by Rensselaer for broad OCC building applications, the control system will analyze how to deliver the right amount of the right type of illumination only where and when it is needed based these OCC platforms. To create these powerful autonomous lighting control platforms, the project will integrate evolving augmented reality (AR) and virtual reality (VR) tools with sophisticated lighting and interior design toolkits to create interactive lighting design and control simulators. Using the quickly growing paradigm of digital twins, these tools will integrate light fixture properties, occupancy sensor data, interior design data, and lighting specifications to accurately visualize how various design concepts interact with simulated yet realistic human activities that occur in commercial office buildings of various types. These advanced digital twin design and simulation tools will be combined with a new class of digitally-programmable LED lighting fixtures that can dynamically change the spectral content and direction of light emission. When fully integrated, the new autonomous lighting control system will take all of the guesswork out of optimizing light quality while minimizing energy consumption. Digital twin tools will simplify the design, installation, commissioning, operation, and maintenance of future energy-efficient lighting systems. It should be possible to reduce lighting energy costs from 40% to 70% with OCC based dynamic light sculpting systems. The work will be led by the Center for Lighting Enabled Systems and Applications (LESA) and the Center for Architectural Science and Ecology (CASE), both at Renssealer Polytechnic Institute; Lumileds, a global leader in the development of advanced LED systems; and HKS, a leading global architecture design firm. This interdisciplinary project team’s experience includes all of the design simulation tools, VR/AR digital twin visualization technology, advanced occupancy sensing technology, and complex control system design capabilities that will revolutionize lighting design and control technology to autonomously deliver high-quality lighting that improves human health and wellbeing while simultaneously maximizing lighting energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Ventilation for Advanced California Homes

This project investigated smart ventilation approaches to minimize energy use for providing indoor air quality (IAQ) in high performance new California homes. Evaluation criteria included annual ventilation-related energy, peak energy and time-of-use savings, and the indoor air quality relative to a minimally code-compliant ventilation system. The simulations used CONTAM’s air flow and contaminant transport model, combined with the EnergyPlus building loads model. House types representing the default California Energy Code compliance homes were investigated for four California climate zones, covering a wide range of climate types. Both single and multi-zone smart ventilation controls were investigated. Contaminant sources included contaminants emitted continuously and varying with time, temperature and relative humidity, episodic emissions from occupant activities and outdoor particles. Single-zone ventilation controls that varied ventilation depending on outdoor temperatures were able to consistently save half of ventilation-related energy without compromising long-term IAQ. Ventilation strategies that tracked occupancy were less successful, because this work included generic contaminants with constant background emission rates. Energy performance for occupancy controls improved with a one-hour pre-occupancy flush out strategy. The addition of zoning ventilation controls did not offer significant IAQ to energy improvements compared to non-zonal versions of the same ventilation system type. The best controls had HVAC energy savings of 10-20%, with individual cases reaching up to 40% savings. However, these savings cannot be achieved without worsening personal exposures for at least one contaminant. A metric is needed to assess the competing changes in exposure to different contaminants in order to determine the net-health impacts of a control strategy. Controls that directly sensed contaminants and controlled them to acceptable levels showed that the California OEHHA limit for formaldehyde completely dominates system performance, with homes not able to meet the limit even with continuous operation of a fan sized to twice the current code minimum.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗