Search NASA⌕ Search

SEARCH · Search NASA

Results for “smart power grids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Systematic Study to Determine 5G Baseline Performance for Scientific Computing

The fifth-generation (5G) cellular networks envisions achieving higher data rates, improved connectivity, reduced latency, and better quality of service (QoS) than the fourthgeneration (4G) cellular networks. Such improved performance can be utilized to address the challenges in applications such as electricity generation in power systems. The traditional power grids responsible for electricity generation suffer from drawbacks such as life-threatening blackout crises, and energy storage proliferation as they are not robust to extreme climatic conditions. A recent study proposed the idea of extending the capabilities of advanced wireless technologies such as the current 5G to develop a robust, energy-efficient, and secure smart grids. However there are two main challenges associated with the integration of power systems and wireless technologies. First, it is imperative to understand the architecture and the enabling technologies of 5G to ensure that the performance requirements of the smart grids are met. Second, an end-to-end testbed is required to determine if the performance requirements are met by estimating the 5G characteristics such as latency, and throughput. Our proposed alleviates the aforementioned concerns in the following manner. To begin with, a systematic study of the 5G architecture including both the StandAlone (SA) and Non-Standalone (NSA) operations is presented. Furthermore, a detailed survey of the possible 5G enabling technologies is elicited. In addition to these, an end-toend testbed that can estimate the 5G characteristics is explained in detail with appropriate preliminary results.

5G, 5G Communication↗

Man‐in‐the‐middle attacks and defence in a power system cyber‐physical testbed

Abstract Man‐in‐The‐Middle (MiTM) attacks present numerous threats to a smart grid. In a MiTM attack, an intruder embeds itself within a conversation between two devices to either eavesdrop or impersonate one of the devices, making it appear to be a normal exchange of information. Thus, the intruder can perform false data injection (FDI) and false command injection (FCI) attacks that can compromise power system operations, such as state estimation, economic dispatch, and automatic generation control (AGC). Very few researchers have focused on MiTM methods that are difficult to detect within a smart grid. To address this, we are designing and implementing multi‐stage MiTM intrusions in an emulation‐based cyber‐physical power system testbed against a large‐scale synthetic grid model to demonstrate how such attacks can cause physical contingencies such as misguided operation and false measurements. MiTM intrusions create FCI, FDI, and replay attacks in this synthetic power grid. This work enables stakeholders to defend against these stealthy attacks, and we present detection mechanisms that are developed using multiple alerts from intrusion detection systems and network monitoring tools. Our contribution will enable other smart grid security researchers and industry to develop further detection mechanisms for inconspicuous MiTM attacks.

Wlazlo, Patrick↗

Determining the Reaction Time for Triggering Supportive Control Actions to Guarantee Adequate Frequency Response in Smart Grids

The progressive integration of renewable energy resources in the modern power grid can result in unsatisfactory frequency responses. To address this problem, wind turbine generators (WTGs), in particular, can be employed to support the power grid. Most works, however, only consider a simple step disturbance. In this paper, a new class of worst-case disturbances is introduced and their nefarious impact on renewable-penetrated power systems is investigated. The worst-case disturbances are derived using optimal control theory. More importantly, the proposed mechanism allows to determine the reaction time to trigger supportive control actions of WTGs to ensure satisfactory frequency response. Numerical results are provided and the effects of the worst-case disturbance on the reaction time are presented.

Luo, Jiecai↗

Real-Time Testbed for Smart Grid Recloser Controller

The growing need for a low voltage recloser has become apparent due to the rise in requirements for a smart grid. This includes more detailed management of power flow forward (towards load) and backward (towards generation), source synchronization in real time, more indepth fault responses, and the use of green energy. The SEL-651R-2 relay is a device that can manage these needs, especially in fault response and synchronization, and is commonly used in systems called microgrids. Microgrids are distribution level systems that are able to operate separated from the main grid, are typically installed much closer to the load(s), and are fed by distributed energy resources (DERs), such as wind, solar or diesel generators. The SEL-651R-2 is normally used in the field with presets operative settings, but the Western Michigan University (WMU) Center for Interdisciplinary Research on Secure, Efficient and Sustainable Energy Technology (WMU InterEnergy Center) wished to test this device in its range of capabilities for microgrid application. A Hardware-In-the-Loop (HIL) testbed was implemented and used through the Real Time Digital Simulator (RTDS) using the RSCAD software to test the SEL-651R-2's use cases and functions. The testbed includes a microgrid with interconnection to a larger main grid, and the relay is meant to control the recloser at the point of common coupling (PCC) between the main grid and microgrid. The testbed shows how basic protections, reclosing, and synchronization checks function when handling faults that affect both the microgrid and the main grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Physical Power Systems Protection: The Byzantine Cybersecurity Framework

Cybersecurity of smart grids have been topic of much interest in recent years. As this critical infrastructure operation increases dependency on automated processes and controls, exposure to cyber-physical threats become inevitable. Considering cyber-physical security of the grid, much focus of attention has been made towards smart grids real-time monitoring solutions, including the state estimation process. Analyzing the relevant literature, one can note though that seldom research has been done on cyber-physical security of smart grids protection systems. Protection systems have intangible value towards grid reliability. This paper presents a cybersecurity framework for smart grids protection systems. A physics-based inspired machine learning solution is at the core process of the framework. Processed relay inputs and outputs are used by a deep predictive coding network. Formal models, a quasi-static state estimator, provides an oracle when low confidence decision is reached. Evolving knowledge is derived through reinforcement learning. Implementation aspects considering the Pacific Northwest National Laboratory Electricity Infrastructure Operations Center are presented. Built as an extra control layer to protection systems, without hard-to-derive parameters, highlights potential aspects towards real-life applications.

Bretas, Arturo Suman↗

Self-Secure Inverters Against Malicious Setpoints

The next generation of grid-interactive inverters brings a communication feature that allows data sharing from utility supervisory controllers and smart devices that are connected to the same network. This feature enhances the control capabilities of grid-interactive inverters to provide services beyond active power injection. However, communication networks entail more vulnerable surfaces to malicious attacks that may result in modifying active and reactive power setpoints and causing weak-grid conditions or abnormal inverter operation. In this paper, steady-state and the dynamic behavior of the inverter for the incoming setpoints are analyzed to detect false data injection attacks and provide device-level security. The steady-state behavior of the inverter in the operating region is determined from the grid parameters such as the grid voltage and the grid impedance. These estimations are accomplished by the proposed self-security technique through a low-frequency signal injection-based approach combined with the recursive least square method. Moreover, a reduced fourth-order inverter model is used as the dynamic reference model, and grid parameters as well as the incoming setpoints are implemented to the reference model to verify whether the dynamic behavior of the inverter is inside the permissible region of operation. The validity and performance of the proposed method are verified experimentally through Allen-Bradley Powerflex 755 three-phase inverter and a 12 kW NHR 9410 regenerative power grid emulator. The results show that the self-secure smart-inverter is able to accept or reject the incoming commands and thus is protected from malicious cyber-physical attacks.

Hossen, Tareq↗

Voltage Support With PV Inverters in Low-Voltage Distribution Networks: An Overview

Large solar photovoltaic (PV) penetration using inverters in low voltage (LV) distribution networks may pose several challenges, such as reverse power flow and voltage rise situations. These challenges will eventually force grid operators to carry out grid reinforcement to ensure continued safe and reliable operations. However, smart inverters with reactive power control capability enable PV systems to support voltage quality in the distribution network better. Here, this paper gives an overview of the current state-of-the-art control strategies for handling voltage problems through PV inverters and other devices. In addition, the (control) technical issues of PV systems integrated into the LV distribution network are considered from a control point of view. By comparing the control issues of PV integration into the grid, the paper aims to help distribution system operators to expand the volume of PV generation in the distribution system in an efficient and safe manner. Additionally, it will help control engineers and researchers select proper control strategies for PV systems as well as other distributed renewable sources.

42 ENGINEERING↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

900-MHz LTE network↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications: Preprint

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

900 MHz LTE network↗

Soft-Switching Solid-State Transformer With Reduced Conduction Loss

Solid-state transformers (SSTs) are a promising solution photovoltaic (PV), wind, traction, data center, battery energy storage system (BESS), and fast charging electric vehicle (EV) applications. The traditional SSTs are typically three-stage, i.e., hard-switching cascaded multilevel rectifiers and inverters with dual active bridge (DAB) converters, which leads to bulky passives, low efficiency, and high electromagnetic interference (EMI). This article proposes a new soft-switching solid-state transformer (S4T). The S4T has full-range zero-voltage switching (ZVS), electrolytic capacitor-less dc link, and controlled dv/dt, which reduces EMI. The S4T comprises two reverse-blocking current-source inverter (CSI) bridges, auxiliary branches for ZVS, and transformer magnetizing inductor as a reduced dc link with 60% ripple. Compared with the prior S4T, an effective change on the leakage inductance diode is made to reduce the number of the devices on the main power path by 20% for significant conduction loss saving and retain the same functionality of damping the resonance between the leakage and resonant capacitors and recycling trapped leakage energy. The conduction loss saving is crucial, being the dominating loss mechanism in SSTs. Importantly, the proposed single-stage SST not only holds the potential for high power density and high efficiency but also has full functionality, e.g., multiport dc loads integration, voltage regulation, and reactive power compensation, unlike the traditional single-stage matrix SST. The S4T can achieve single-stage isolated bidirectional dc–dc, ac–dc, dc–ac, or ac–ac conversion. It can also be configured input-series output-parallel (ISOP) in a modular way for medium-voltage (MV) grids. Hence, the S4T is a promising candidate for the SST. The full functionality, e.g., voltage buck–boost, multiport, etc., and the universality of the S4T for the dc–dc, dc–ac, and ac–ac conversion are verified through the simulations and experiments of two-port and three-port MV prototypes based on 3.3 kV SiC MOSFETs in dc–dc, dc–ac, and ac–ac modes at 2 kV.

14 SOLAR ENERGY↗

Multifold Insights for Power System Dynamics From Data Assimilation: Meeting Current Challenges

The world’s electric power grids have evolved over the last 120 years from a single power line to today’s large networks. The evolution will continue at an accelerated rate with extensive smart grid development worldwide. Here for example, the U.S. government has set a goal of reaching 100 percent carbon pollution-free electricity by 2035, while the Department of Energy (DOE) shared a goal to deploy 30 GW and 110 GW of offshore wind by 2030 and 2050, respectively. To meet such ambitious goals, in the years to come, a significant percentage of electricity will come from intermittent renewable sources, electric vehicles (EVs), and be supplied to a vast number of loads that will actively respond to grid conditions and incentive signals. This development is largely driven by environmental and economic factors, such as reducing carbon emissions and saving electricity cost for consumers. These energy resources lead to new uncertain behaviors and dynamics which the grid has never seen and were not considered in its design. Operating such a dynamic grid with sufficient reliability and efficiency is a monumental challenge.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Electric Vehicle Charging and Discharging Strategies Under DER Compensation Programs: Preprint

The adoption of electric vehicles (EVs) is becoming increasingly popular because of environmental concerns, the greater availability of models, and increased cost-competitiveness with gas vehicles. Because EVs have both charging and discharging capabilities, they provide great potential to help electric utilities with grid operation. When the grid demand is high, EVs can discharge to the grid to reduce the peak load, and vice versa; therefore, electric utilities have designed different policies to encourage EV charging station operators to charge or discharge at certain time periods. The New York State Public Service Commission established the Value of Distributed Energy Resources (VDER), or the Value Stack, to compensate for energy created by distributed energy resources, including EVs. This paper presents an optimization-based approach to identify the "golden hours" and "golden spots," i.e., the effective time periods and geographic locations for EV charging station operators to charge or discharge under the VDER program that can provide them the highest benefit. The proposed methodology can be applied to other compensation mechanisms and distribution systems as well. By working with industry partner NineDot Energy, realistic charging station information is used in this study, and the proposed approach is tested on a distribution feeder. The results from this study can help electric utilities and EV charging station operators determine the ideal charging/discharging time and the ideal locations for the charging station(s) in their distribution systems to achieve maximized benefit.

electric vehicle↗

Power Electronics for Electrolyzer Applications to Enable Grid Services

The Power Electronics for Electrolyzer Applications to Enable Grid Services project aims to develop smart converter for dedicated electrolyzer applications to enable grid services via standardization of control interfaces between hydrogen electrolyzer system low-level controls and power converter controls. The project provides additional revenue source for electrolyzer through participation in grid services and reduces the cost of deployment and controls integration through standardization and risk due to supply-chain issues. It also enables the adoption of green hydrogen via standardizing the integration of energy storage, renewables, and distributed energy resources. Furthermore, the work provides a controlled validation environment to evaluate scalable integration solution for hydrogen production technologies, improves overall reliability and maintainability of the electrolyzer system for grid applications, and directly contributes to DOE HFTO's "Hydrogen Shot" goal.

energy transitions↗

Applications of Digital Twin System in a Smart City System with Multi-Energy

With the increasing number of electric vehicles (EV), the smart transportation system is becoming more closely related to the smart energy system in a smart city. However, because of the high complexity, dynamics, and large-scale of these two systems, it is challenging to study their operation problems systematically, especially in severe conditions, e.g., the 2021 winter Texas power traffic crisis. With artificial intelligence, federated learning, edge computing, and automatic control, a digital twin based smart city is proposed in this paper and it focuses on two applications: smart transportation and smart energy grid. Both systems are presented in a structured design manner with several components in the digital twin system, which also contains many real-implementations of different scenarios. The proposed digital twin of a smart city provides a potential clue for the problems mentioned above.

artificial intelligence↗

Studying impacts of communication system performance on dynamic stability of networked microgrid

The development of smart grid technologies has resulted in increased interdependence between power and communication systems. Many of the operations in the existing power system rely on a stable and secured communication system. For electrically weak systems and time‐critical applications, this reliance can be even greater, where a small degradation in communication performance can degrade system stability. However, despite inter‐dependencies between power and communication systems, only a few studies have investigated the impacts of communication system performance on power system dynamics. This study investigates the dependencies of power system dynamics operations on a communication system performance. First, a detailed, dynamic networked microgrid model is developed in the GridLAB‐D simulation environment, along with a representative multi‐traffic, multi‐channel, multi‐protocol communication system model, developed in the network simulator (ns‐3). Second, a hierarchical engine for large‐scale infrastructure co‐simulation framework is developed to co‐simulate microgrid dynamics, its communication system, and a microgrid control system. The impact of communication system delays on the dynamic stability of networked microgrids is evaluated for the loss of generation using three use‐cases. While the example use‐cases examine microgrid applications and the impact to resiliency, the framework can be applied to all levels of power system operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pricing and Energy Trading in Peer-to-Peer Zero Marginal-Cost Microgrids

Efforts to utilize 100% renewable energy in community microgrids require new approaches to energy markets and transactions to efficiently address periods of scarce energy supply. In this paper we contribute to the promising approach of peer-to-peer (P2P) energy trading in two main ways: analysis of a centralized, welfare-maximizing economic dispatch that characterizes optimal price and allocations, and a novel P2P system for negotiating energy trades that yields physically feasible and at least weakly Pareto-optimal outcomes. Our main results are 1) that optimal pricing is insufficient to induce agents with batteries to take optimal actions, 2) a novel P2P algorithm to addresses this while keeping private information, 3) a formal proof that this algorithm converges to the centralized solution in the case of two agents negotiating for a single period, and 4) numerical simulations of the P2P algorithm performance with up to 10 agents and 24 periods that show it converges on average to total welfare within 0.1% of the social optimum in on the order of 10s to 100s of iterations, increasing with the number of agents, time periods, and total storage capacity.

batteries↗

Cooperative Model Predictive Control Scheme for Dispersed Smart Inverters at the Grid Edge

Growing number of distributed energy resources (DERs) requires cutting-edge control schemes to ensure uniform but not identical involvement of DERs to address rapid fluctuations on voltage of the grid clusters. Designing such control schemes for a grid with high penetration of DERs connected various clusters is complex and depends on physical configuration of the clusters themselves. This paper proposes a two-layered cooperative model predictive control scheme for fleet of dispersed smart inverters connected to a three-phase grid cluster located at the edge of a grid cluster. The upper layer of the controller ensures cooperative operation of fleet of smart inverters to perform voltage regulation and address voltage fluctuations in the grid cluster; while the lower level controller guarantees each individual inverter obeys the dictated references for active/reactive powers by the upper layer controller. In addition, the proposed twolayered controller has low voltage ride through (LVRT) capability to support the grid clusters during voltage sags. By employing the proposed control approach, the smart inverters will inject desired active/reactive powers based on circumstance of the entire cluster while guaranteeing proper power curtailment among the generation units. The control scheme is verified by simulation.

Fard, Amin Y.↗