Search NASA⌕ Search

SEARCH · Search NASA

Results for “software engineering release engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

93 records · Page 6

Direct Current Arc-Flash Hazards of Solar Photovoltaic Systems

An arc-flash is a rapid release of thermal energy, pressure waves, and electromagnetic interference from a high-power electrical system, caused by such events as unintentional shorting or equipment malfunction. Arc-flashes are hazardous to people and equipment. Incident energy (IE) is a means of quantifying the degree of thermal hazard posed by an arc-flash event. The calculated IE value dictates what level of personal protective equipment (PPE) workers are required to wear when servicing equipment. Overly burdensome PPE may increase a worker’s discomfort and decrease dexterity, which could lead to unintentional shorting, while inadequate PPE also comes with increased safety risks. The majority of arc-flash research to date has focused on alternating current (ac) systems. For example, IE calculations and PPE for ac systems are relatively well understood and have been applied across many equipment types and voltages. IE calculation methodologies in ac systems are backed by a wide range of industry tests and are included in Institute of Electrical and Electronics Engineers (IEEE) and National Fire Protection Association (NFPA) standards. However, very little is known about direct current (dc) arc-flash and its hazards. This is a significant knowledge gap, as an increasing number of dc systems are being deployed: solar photovoltaic (PV) plants, battery storage, and electric vehicles and their charging infrastructure. The dc arc-flash hazard publications are rooted primarily in theory, and their IE calculation methods contradict each other. Insufficient knowledge and data are preventing the formation of industry consensus and standards around dc arc-flash hazard assessment. Here, this white paper highlights the current status and research opportunities for assessing arc-flash hazards in dc systems, with a focus on PV plants. The nonlinear current-voltage characteristics of PV modules make them unique in comparison to other linear dc sources, such as batteries. Also, PV equipment has rapidly evolved from 600 Vdc to 1,500 Vdc (in the United States), increasing potential arc-flash hazards. The operating regime of a PV-array within its I-V characteristic curve during an arc-flash event and the sustainability of arc-flash events in a utility-scale PV plant need to be investigated. Arc-flash experiments on a 1-MWdc nameplate capacity utility-owned ground-mount photovoltaic plant suggest that the PV array acts as a constant-current supply with currents near the short-circuit portion of the I-V characteristic curve of the array, with median arc voltage as 1/3 of the rated voltage. Various engineering software packages (CYME7 by EATON, PTW by SKM, ArcFlash™ by EasyPower, ETAP, and so on) have started offering dc arc-flash calculation features to estimate the risk of arc-flash in dc and PV systems. However, they are reliant on the same simplified arc-flash models, which contradict each other due to differences in assumptions such as characteristics of the power source, arc current, voltage and impedance, arc-operating regime, and so on. Physical arc-flash testing and improved physics-based modeling with correct assumptions representing practical scenarios are two methods to improve understanding and quantify the risks associated with dc arc-flash hazards. The results would inform development of a more accurate calculation procedure for IE and proper PPE levels.

14 SOLAR ENERGY↗

Cybersecurity Platform and Certification Framework Development for Extreme Fast Charging (XFC)-Integrated Charging Ecosystem (Final Project Report)

This report summarizes a pioneering effort in Electric Vehicle charging infrastructure ecosystem cybersecurity requirements, assessment methodologies, functional verification, as well as embodiment of the key technologies in the form of hardware and software tools being made available to the public. EPRI led a team of experts, as well as a stakeholder coalition encompassing all key actors in the EV charging infrastructure ecosystem that includes eXtreme Fast Charging (XFC) equipment (defined as 200kW or above). EV charging infrastructure in the United States is a patchwork of networks that have continued to grow organically and have been designed to serve the charging needs of the EV owners, who are their customers. In doing so, each network provider, as well as their connected entities such as the cloud Electric Vehicle Service Providers or EVSPs, utility back office, utility AMI networks, payment networks, as well as Original Equipment Manufacturer (EV manufacturer) telematics networks, have designed systems that may work well individually, but no single entity is responsible for the entire ecosystem to be secure in terms of data exchange. Furthermore, there is no uniformity in how each actor has implemented the cybersecurity requirements since no system-wide cybersecurity requirements existed prior to this project. The final project report describes the technical approach guided by the EV charging infrastructure cybersecurity working group, convened specifically for this project. The technical approach included definition of requirements at the ecosystem level, treated as a ‘system of systems’, and then passed down to individual systems (EVSE, EV, cloud EVSP, utility, and the payment networks), followed by developing the cybersecurity risk and vulnerability assessment methods, that were later applied to real-world cyber-physical systems at EPRI, ANL, and NREL laboratories, to validate both the process and the results. Finally, in a spotlight over the most vulnerable equipment, which is the EV charge station (AC or DC), the team developed a multi-layer cybersecurity implementation in the embedded domain embodied by the open-source Secure Network Interface Card (SNIC) demonstrating the various ways in which the infrastructure can be secured protecting against the identified attack surfaces. Finally, the entire process of EV infrastructure cybersecurity assessment was encapsulated in the Electric Vehicle Charging Cybersecurity Management (EVC2M) online GUI-based tool, that is expected to be released to the public. The report presents the objectives, the technical approach, the key results, and recommendations for future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Assessment of a Generic Nuclear Waste Repository in Shale - 18392

A performance assessment (PA) is an important component of a comprehensive safety analysis for a nuclear waste repository. In a PA, probabilistic simulations of the total repository system are performed, and results are evaluated against performance metrics. Uncertainty and sensitivity analyses help prioritize additional research and model development. The United States Department of Energy (DOE) has been developing a state of the art PA simulation software tool-kit, Geologic Disposal Safety Assessment (GDSA) Framework, that couples increasingly higher fidelity models of subsystem processes into total system PA simulations. Over the past several years, PAs of generic repositories in three geologic media (salt, shale, and crystalline rock) have demonstrated ongoing developments in capability. The current PA of a nuclear waste repository in a generic shale formation showcases GDSA Framework, including capabilities in domain discretization (Cubit), multi-physics simulations (PFLOTRAN), uncertainty and sensitivity analysis (Dakota), and visualization (Paraview). The generic shale reference case considers the disposal of 22,000 metric tons heavy metal of commercial spent nuclear fuel (SNF) in a generic shale formation. PA simulations account for the thermal load and radionuclide inventory of the waste form, components of the engineered barrier system including waste package and buffer, and components of the natural barrier system including the host rock shale and underlying and overlying stratigraphic units. Two repository layouts are considered, one for emplacement of waste packages containing 12 pressurized water reactor (PWR) assemblies, and one for 4-PWR waste package emplacement. Model domains are half-symmetry and contain between 7 and 22 million grid cells. Grid refinement captures the detail of individual waste packages, emplacement drifts, access drifts, and shafts. Simulations are run in a high-performance computing (HPC) environment on 512 or 2048 processes. The governing equations describing coupled heat and fluid flow and reactive transport are solved with PFLOTRAN, an open-source, massively parallel multiphase flow and reactive transport code. Additional simulated processes include waste package degradation; waste form dissolution; radioactive decay and ingrowth in aqueous, solid, and adsorbed phases; and a simple biosphere based on a pumping well. Simulations are run to 106 y; dose and radionuclide concentrations are observed within aquifers at a point approximately 5 km downgradient of the repository. Dakota is used to sample likely ranges of input parameters including waste form and waste package degradation rates and properties of engineered and natural materials to quantify uncertainty in predicted concentrations and sensitivity to input parameters. Given the assumptions of the reference case, results of 12-PWR and 4-PWR simulations are very similar. Dose at the pumping well 5-km downgradient of the repository does not exceed 10-9 Sv/y. I-129 is the largest contributor to dose. The dose due to Cl-36, the next largest contributor, is orders of magnitude smaller. At the pumping well, the concentration of I-129 5-km downgradient does not exceed 10-14 mol/L. Rank correlation coefficients indicate that the maximum concentration of I-129 within the aquifer is sensitive to shale (repository host rock) porosity and aquifer permeability. These results affirm that HPC-capable codes can be used to simulate important multi-physics couplings directly in a total system performance assessment of a geologic repository, and can be used in prioritization of future research and model development. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗