Search NASA⌕ Search

SEARCH · Search NASA

Results for “software quality process improvement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Performance analysis of data intensive cloud systems based on data management and replication: a survey

As we delve deeper into the ‘Digital Age’, we witness an explosive growth in the volume, velocity, and variety of the data available on the Internet. For example, in 2012 about 2.5 quintillion bytes of data was created on a daily basis that originated from myriad of sources and applications including mobiledevices, sensors, individual archives, social networks, Internet of Things, enterprises, cameras, software logs, etc. Such ‘Data Explosions’ has led to one of the most challenging research issues of the current Information and Communication Technology era: how to optimally manage (e.g., store, replicated, filter, and the like) such large amount of data and identify new ways to analyze large amounts of data for unlocking information. It is clear that such large data streams cannot be managed by setting up on-premises enterprise database systems as it leads to a large up-front cost in buying and administering the hardware and software systems. Therefore, next generation data management systems must be deployed on cloud. The cloud computing paradigm provides scalable and elastic resources, such as data and services accessible over the Internet Every Cloud Service Provider must assure that data is efficiently processed and distributed in a way that does not compromise end-users’ Quality of Service (QoS) in terms of data availability, data search delay, data analysis delay, and the like. In the aforementioned perspective, data replication is used in the cloud for improving the performance (e.g., read and write delay) of applications that access data. Through replication a data intensive application or system can achieve high availability, better fault tolerance, and data recovery. In this paper, we survey data management and replication approaches (from 2007 to 2011) that are developed by both industrial and research communities. The focus of the survey is to discuss and characterize the existing approaches of data replication and management that tackle the resource usage and QoS provisioning with different levels of efficiencies. Moreover, the breakdown of both influential expressions (data replication and management) to provide different QoS attributes is deliberated. Furthermore, the performance advantages and disadvantages of data replication and management approaches in the cloud computing environments are analyzed. Open issues and future challenges related to data consistency, scalability, load balancing, processing and placement are also reported.

Malik, Saif Ur Rehman↗

Applications of GIS and remote sensing in public participation and stakeholder engagement for watershed management

The use of Geographic Information Systems (GIS) and remote sensing technologies for the development of water quality management programs and for post-implementation assessments has increased dramatically in the past decade. This increase in adoption has been made more accessible through the interfaces of many popular software tools used in the regulation and assessment of water quality. Customized applications of these tools will increase, as ease of access and affordability of directly monitored and remotely sensed datasets improve over time. Concurrently, there is a need for inclusive participatory engagement with stakeholders to achieve solutions to current watershed management challenges. This paper explores the potential of these GIS and remote sensing datasets, tools, models, and immersive engagement technologies from other domains, for improving public participation and stakeholder engagement throughout the watershed planning process. To do so, an initial review is presented about the use of GIS and remote sensing in watershed management and its role in impairment identification, model development, and planning and implementation. Then, ways in which GIS and remote sensing can be integrated with stakeholder engagement through (1) leveraging GIS and remote sensing datasets, and (2) stakeholder engagement approaches including outreach and education, modeler-led development, and stakeholder-led involvement and feedback, are discussed. Finally, future perspectives on the potential for transforming public participation and stakeholder engagement in the watershed management process through applications of GIS and remote sensing are presented.

54 ENVIRONMENTAL SCIENCES↗

Improvements in Reflected Target Non-intrusive Assessment (ReTNA)

Accurate optical surfaces are a primary driver of concentrated solar power plant performance. Errors in pointing and tracking mirrors, the canting of individual mirror facets, and the surface slope of the mirror itself can be caused by errors during assembly, transportation, wind loading, gravity, and many other sources. The tools that exist to measure these error sources today largely rely on fringe deflectometry (SOFAST, QDec, others), or photogrammetry with targets attached to the mirror surface. In 2022, NREL presented a new indoor optical measurement system to measure fully assembled heliostats during development and on the assembly line for quality assurance purposes, which has undergone significant development in the last year, including the installation of a new, larger laboratory setup. This system, called ReTNA (Reflected Target Non-intrusive Assessment), uses a printed pattern as a deflectometry target. Using printed pattern features as deflectometry targets instead of fringes allows the software to measure the surface slope in two dimensions, eliminating the need to for changing, projected targets. In the last year, NREL's ReTNA tool has been adapted to use a tall, thin target, that only spans one dimension of the mirror, and a camera moving on an automatic track system. We will present these new developments, including the new setup, target patterns, software methodology for fast, automatic optical analysis, and important lessons learned throughout the process. ReTNA results will be compared to established tools, to establish the uncertainty of this new method. ReTNA leverages recent improvements in computer vision and photogrammetry to remove as much careful calibration from the setup process as possible, making the tool low cost, simple, and portable. While it will not achieve the resolution of a fringe deflectometry system, its advantages make it well suited for CSP evaluation, and allow it to fill a different industry need.

concentrating solar power↗

2011 EnergyValue Housing Award Report

The EnergyValue Housing Award (EVHA), an integral part of the U.S. Department of Energy’s Building America (BA) program, seeks to improve and expand the energy efficiency of residential construction nationwide by honoring builders and remodelers and awarding highly efficient homes. Receiving EVHA recognition helps builders and remodelers communicate the value of energy efficiency to prospective customers and distinguish their homes from those built by more traditional residential construction companies. It also provides opportunities for EVHA winning builders and remodelers to set an example for improving the quality and performance of homes throughout the country. Each year, the project scope of the EVHA includes the application and judging processes, developing the EVHA publication, updating the program and application for the next year, hosting the EVHA banquet, and outreach and technical support. Following the award banquet, the NAHB Research Center evaluates the energy performance of that year’s EVHA winning houses. This work is primarily comprised of estimating the energy savings of each home/ or housing unit over the BA Benchmark using energy simulation software and procedures developed by the BA program. The energy evaluations serve as a quantitative measure of the energy efficiency of the units which the judges decided merited an award. As part of this work, the NAHB Research Center Industry Partnership (NAHBRC-IP) for High Performing Homes strives to make new and existing homes more energy efficient, durable, and affordable through research and development as one of the U.S. Department of Energy’s BA teams. Each year, through the EVHA, builder and remodeler partners work with industry partners in a variety of climates endeavor to reach the energy efficiency targets of the BA program. (Department of Energy 2012) This report details the simulation tool(s) and energy modeling methodology followed in making the energy efficiency estimates and documents the estimated performance of the EVHA award winning houses in comparison with the BA Benchmark and the associated House Simulation Protocols (HSPs). A summary of each building and its features is included with a brief description of the project and the judges’ comments. The purpose of this report is to assess the energy performance of the 2011 EVHA winners and to align the EVHA program with the BA program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clean Water Production in Cooling Towers

This project developed and demonstrated a novel technology that produces clean water from cooling tower recirculating water by using the natural evaporation and condensation cycle inside cooling towers. The system captures the escaping plume and converts blowdown quality water into high purity water suitable for on-site reuse such as boiler feed. The technology uses electric fields to ionize exhaust plumes, charge the entrained droplets, and direct them toward collection electrodes where they coalesce and flow downward. This allows water recovery at a low energy cost while reducing visible plume emissions. In addition, we developed a complementary software platform that improves overall cooling tower performance. The system uses wireless sensors and physics-based machine learning algorithms to optimize key parameters of the cooling process. For power generation facilities, this increases the thermal efficiency of the cooling loop and condenser, resulting in measurable cycle efficiency gains. Improvements of one percent or more can deliver significant increases in electricity production for the same fuel input.

01 COAL, LIGNITE, AND PEAT↗

Optimization of prefabricated component installation using a real-time evaluator (RTE) connection locating system

Prefabrication promises to industrialize the construction industry. By constructing elements within a manufacturing environment, producers can better control quality and maximize production efficiency. Since the major adoption of prefabrication, a wide variety of prefabricated components have been produced for varying applications such as new construction and exterior wall retrofits. While the production processes of these prefabricated components have seen much innovation, the installation process has remained relatively unchanged for decades. To innovate the installation process with modern technologies, a real-time evaluator (RTE) has been developed to reduce the installation cost of prefabricated components by reducing installation time, decreasing rework, and improving accuracy. The RTE uses developed software solutions with off-the-shelf hardware to assist erectors in completing an installation by measuring the real-time positions of connections and prefabricated components, providing installation guidance through a graphical user interface, and monitoring the accumulated installation errors. An overview of the RTE and proposed workflow is presented. A connection locating system that guides users in expediting the installation of connections is introduced. Laboratory experiments were conducted to determine the accuracy improvement and time savings of the RTE in installing connections for prefabricated components. RTE enabled a time saving of up to 37% compared to traditional connection installation methods using handheld measurement tools.

Hayes, Nolan↗

SU-F-J-194: Development of Dose-Based Image Guided Proton Therapy Workflow

Purpose: To implement image-guided proton therapy (IGPT) based on daily proton dose distribution. Methods: Unlike x-ray therapy, simple alignment based on anatomy cannot ensure proper dose coverage in proton therapy. Anatomy changes along the beam path may lead to underdosing the target, or overdosing the organ-at-risk (OAR). With an in-room mobile computed tomography (CT) system, we are developing a dose-based IGPT software tool that allows patient positioning and treatment adaption based on daily dose distributions. During an IGPT treatment, daily CT images are acquired in treatment position. After initial positioning based on rigid image registration, proton dose distribution is calculated on daily CT images. The target and OARs are automatically delineated via deformable image registration. Dose distributions are evaluated to decide if repositioning or plan adaptation is necessary in order to achieve proper coverage of the target and sparing of OARs. Besides online dose-based image guidance, the software tool can also map daily treatment doses to the treatment planning CT images for offline adaptive treatment. Results: An in-room helical CT system is commissioned for IGPT purposes. It produces accurate CT numbers that allow proton dose calculation. GPU-based deformable image registration algorithms are developed and evaluated for automatic ROI-delineation and dose mapping. The online and offline IGPT functionalities are evaluated with daily CT images of the proton patients. Conclusion: The online and offline IGPT software tool may improve the safety and quality of proton treatment by allowing dose-based IGPT and adaptive proton treatments. Research is partially supported by Mevion Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-J-215: Onboard Split PET Including the Effects of Attenuation, Scatter, and Random Events

Purpose: Positron emission tomography (PET) using split PET geometry was investigated as an on-board system for functional imaging and PET marker tracking, specifically with tomotherapy. The open dual ring PET would allow measurement of both inter and intra-fractional variation, improving the delineation of tumor volume at any stage in the radiation treatment delivery process. We present results from data obtained using Monte Carlo simulations including the effects of attenuation, random events, and scatter. Methods: PET design was accomplished via Monte Carlo simulations with GATE, the Geant4 Application for Emission Tomography. Images were reconstructed using Software for Image Reconstruction (STIR) with a fully 3D ordered subset expectation maximization (OSEM) image reconstruction technique. Results: Monte Carlo simulations of the split PET geometry indicate that including physical factors that degrade image quality such as attenuation, random events, and scatter still prove the feasibility of near real-time PET for both inter and intra-fractional radiation delivery. The image quality of scan times under 1 minute reveals that it is possible to utilize PET scanning and reconstruction during the treatment session intrafractionally. GATE also simulates the depth information but does not correct obliqueness of the path of line of response so the data is much more realistic than the data obtained with ray tracing. Conclusion: Onboard split PET with TomoTherapy can generate quality images under 1 minute scan times without the need to correct for attenuation, scatter, random events, or depth information of the interaction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High availability through full redundancy of the CMS detector controls system

The CMS detector control system (DCS) is responsible for controlling and monitoring the detector status and for the operation of all CMS sub detectors and infrastructure. This is required to ensure safe and efficient data taking so that high quality physics data can be recorded. The current system architecture is composed of more than 100 servers in order to provide the required processing resources. An optimization of the system software and hardware architecture is under development to ensure redundancy of all the controlled subsystems and to reduce any downtime due to hardware or software failures. The new optimized structure is based mainly on powerful and highly reliable blade servers and makes use of a fully redundant approach, guaranteeing high availability and reliability. The analysis of the requirements, the challenges, the improvements and the optimized system architecture as well as its specific hardware and software solutions are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-AB-303-08: GPU-Based Software Platform for Efficient Image-Guided Adaptive Radiation Therapy

Purpose: In this study, we develop an integrated software platform for adaptive radiation therapy (ART) that combines fast and accurate image registration, segmentation, and dose computation/accumulation methods. Methods: The proposed system consists of three key components; 1) deformable image registration (DIR), 2) automatic segmentation, and 3) dose computation/accumulation. The computationally intensive modules including DIR and dose computation have been implemented on a graphics processing unit (GPU). All required patient-specific data including the planning CT (pCT) with contours, daily cone-beam CTs, and treatment plan are automatically queried and retrieved from their own databases. To improve the accuracy of DIR between pCT and CBCTs, we use the double force demons DIR algorithm in combination with iterative CBCT intensity correction by local intensity histogram matching. Segmentation of daily CBCT is then obtained by propagating contours from the pCT. Daily dose delivered to the patient is computed on the registered pCT by a GPU-accelerated superposition/convolution algorithm. Finally, computed daily doses are accumulated to show the total delivered dose to date. Results: Since the accuracy of DIR critically affects the quality of the other processes, we first evaluated our DIR method on eight head-and-neck cancer cases and compared its performance. Normalized mutual-information (NMI) and normalized cross-correlation (NCC) computed as similarity measures, and our method produced overall NMI of 0.663 and NCC of 0.987, outperforming conventional methods by 3.8% and 1.9%, respectively. Experimental results show that our registration method is more consistent and roust than existing algorithms, and also computationally efficient. Computation time at each fraction took around one minute (30–50 seconds for registration and 15–25 seconds for dose computation). Conclusion: We developed an integrated GPU-accelerated software platform that enables accurate and efficient DIR, auto-segmentation, and dose computation, thus supporting an efficient ART workflow. This work was supported by NIH/NCI under grant R42CA137886.

60 APPLIED LIFE SCIENCES↗

ATLAS data quality operations and performance for 2015–2018 data-taking

The ATLAS detector at the Large Hadron Collider reads out particle collision data from over 100 million electronic channels at a rate of approximately $100$ kHz, with a recording rate for physics events of approximately 1 kHz. Before being certified for physics analysis at computer centres worldwide, the data must be scrutinised to ensure they are clean from any hardware or software related issues that may compromise their integrity. Prompt identification of these issues permits fast action to investigate, correct and potentially prevent future such problems that could render the data unusable. This is achieved through the monitoring of detector-level quantities and reconstructed collision event characteristics at key stages of the data processing chain. This paper presents the monitoring and assessment procedures in place at ATLAS during 2015-2018 data-taking. Through the continuous improvement of operational procedures, ATLAS achieved a high data quality efficiency, with 95.6% of the recorded proton-proton collision data collected at $\sqrt{s}=13$ TeV certified for physics analysis.

43 PARTICLE ACCELERATORS↗

TeO{sub 2} liquid phase: Viscosity measurements and evaluation of the thermal conductivity from crystal growth experiments

Current applications of paratellurite TeO{sub 2} in optics and nuclear physics require improving the yield and optical quality of synthesized single crystals. Modelling of the growth process is a useful tool for such purpose, however, involving the knowledge of several thermodynamic parameters of both solid and liquid phase of the compound. This work describes the determination of two main unknown ones, namely dynamic viscosity {eta} and thermal conductivity {lambda}{sub l} of the liquid phase. Measurements of {eta} are performed by means of a specifically designed apparatus; over a 40 K temperature interval above the melting point we find a mean value of 0.028 Pa.s. This data is used in commercial software to depict the evolution of the solid-liquid interface in our Bridgman growth set-up. Comparison of the distribution of defects observed in grown ingots with the results of modelling allows estimating {lambda}{sub l} as lying in the range 3.50-3.75 W m{sup -1} K{sup -1}.

36 MATERIALS SCIENCE↗

Provenance–aware workflow for data quality management and improvement for large continuous scientific data streams

Data quality assessment, management and improvement is integral part of any big data intensive scientific research to ensure accurate, reliable and reproducible science discoveries. The task of maintaining the quality of data, however, is non-trivial and pose a challenge for a program like Department of Energy’s Atmospheric Radiation Measurement (ARM) that collects data from hundreds of instruments across the world,and distributes thousands of streaming data products that are continuously growing in near-real-time in an archive 1.7 Petabyte in size and growing. We present a computational data processing workflow to collect the data quality issue via an easy and intuitive web-based portal that allows reporting of any quality issues for any site, facility or instruments at a granularity down to individual variable in the data files. Portal allows instrument specialists and scientists to provide corrective actions in form of symbolic equation. A parallel processing framework applies the data improvement to large volume of data in efficient parallel environment, while optimizing data transfer and file I/O operations. Corrected files are systematically versioned and archived. A provenance tracking module tracks and records any change made to the data during its entire life cycle which are communicated transparently to the scientific users. Developed in Python using open source technologies, software architecture enables efficient and fast management and improvement of data in an operational data center environment.

Kumar, Jitendra↗

Demonstration and Automation of Reflected Target Optical Measurement for Heliostats

Accurate optical surfaces are a primary driver of concentrated solar power plant performance. Errors in pointing and tracking mirrors, the canting of individual mirror facets, and the surface slope of the mirror itself can be caused by errors during assembly, transportation, wind loading, gravity, and many other sources. The tools that exist to measure these error sources today largely rely on fringe deflectometry (SOFAST, QDec, others), or photogrammetry with targets attached to the mirror surface. Since 2022, NREL has been developing a measurement method called the Reflected Target Non-intrusive Assessment (ReTNA) system. This system differs from most established methods in that we perform deflectometry with a pattern of coded targets, identified in space with photogrammetry. Reflected target systems have several advantages over traditional fringe deflectometry systems. Firstly, they can be operated in bright or ambient lighting, a challenge for fringe systems that use a projector and screen. Reflected target systems also can use a much lighter and less expensive target than projector-based systems. Lastly, 2D slope measurement can be solved from a single image, which leads to several advantages for accommodating faster measurements and smaller sized targets. These advantages make ReTNA particularly well-suited for applications where there are space or lighting constraints, like performing heliostat quality assurance on an assembly line. It's also useful when a lightweight, flexible system is needed, like for heliostat developers to quickly measure a new heliostat design at different orientations, to observe gravitational effects on the mirror surface shape. In the last year, significant improvements were made to this tool to make it more useful for these applications. These improvements were focused around validation of the ReTNA measurement system, and automation of the setup and measurement process. First, we present an improved ReTNA layout, for use on the heliostat assembly line. Next, we detail the various changes to the ReTNA software and computer vision methods to automate data collection in this new setup, and lessons learned from this process. The goal with this new setup is to perform a full heliostat surface characterization without removing the mirror from the assembly line. Lastly, we share results from several ReTNA validation studies undertaken over the last year. These include repeated ReTNA measurement on demonstration mirror facets, comparisons with other optical measurement tools, and some studies aimed at quantifying the uncertainty of ReTNA measurement under various constraints (mirror-target spacing, camera resolution, etc.). These results are compared with 2024 HelioCon performance targets, and our planned next steps for the ReTNA measurement system are presented.

CSP↗

Implications of Artefacts Reduction in the Planning CT Originating from Implanted Fiducial Markers

The efficacy of metal artefact reduction (MAR) software to suppress artefacts in reconstructed computed tomography (CT) images originating from small metal objects, like tumor markers and surgical clips, was evaluated. In addition, possible implications of using digital reconstructed radiographs (DRRs), based on the MAR CT images, for setup verification were analyzed. A phantom and 15 patients with different tumor sites and implanted markers were imaged with a multislice CT scanner. The raw image data was reconstructed both with the clinically used filtered-backprojection (FBP) and with the MAR software. Using the MAR software, improvements in image quality were often observed in CT slices with markers or clips. Especially when several markers were located near to each other, fewer streak artefacts were observed than with the FBP algorithm. In addition, the shape and size of markers could be identified more accurately, reducing the contoured marker volumes by a factor of 2. For the phantom study, the CT numbers measured near to the markers corresponded more closely to the expected values. However, the MAR images were slightly more smoothed compared with the images reconstructed with FBP. For 8 prostate cancer patients in this study, the interobserver variation in 3D marker definition was similar (<0.4 mm) when using DRRs based on either FBP or MAR CT scans. Automatic marker matches also showed a similar success rate. However, differences in automatic match results up to 1 mm, caused by differences in the marker definition, were observed, which turned out to be (borderline) statistically significant (p = 0.06) for 2 patients. In conclusion, the MAR software might improve image quality by suppressing metal artefacts, probably allowing for a more reliable delineation of structures. When implanted markers or clips are used for setup verification, the accuracy may slightly be improved as well, which is relevant when using very tight clinical target volume (CTV) to planning target volume (PTV) margins for planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stochastic analysis of surface metrology

The design and evaluation of the expected performance of optical systems require sophisticated and reliable information about the surface topography for planned optical elements before they are fabricated. Modern x-ray source facilities are reliant upon the availability of optics with unprecedented quality (surface slope accuracy <0.1 μrad). The problem is especially complex in the case of x-ray optics, particularly for the X-ray Surveyor under development and other missions. The high angular resolution and throughput of future x-ray space observatories requires hundreds of square meters of high-quality optics. The uniqueness of the optics and limited number of proficient vendors makes the fabrication extremely time consuming and expensive, mostly due to the limitations in accuracy and measurement rate of metrology used in fabrication. Here, we discuss improvements in metrology efficacy via comprehensive statistical analysis of a compact volume of metrology data. The data are considered stochastic, and a statistical model called invertible time-invariant linear filter (InTILF) is developed now for two-dimensional (2-D) surface profiles to provide compact description of the 2-D data in addition to one-dimensional data treated so far. The InTILF model captures stochastic patterns in the data and can be used as a quality metric and feedback to polishing processes, avoiding high-resolution metrology measurements over the entire optical surface. The modeling, implemented in our BeatMark™ software, allows simulating metrology data for optics made by the same vendor and technology. The data are vital for reliable specification for optical fabrication, to be exactly adequate for the required system performance.

42 ENGINEERING↗

Application-based QoE support with P4 and OpenFlow

Although Software-Defined Wide Area Networks (SD-WANs) are now widely deployed in several production networks, they are largely restricted to traffic engineering approaches based on layer 4 (L4) of the network protocol stack that result in improved Quality-of-Service (QoS) of the network overall without necessarily focusing on a specific application. However, the emergence of application protocols such as QUIC and HTTP/2 needs an investigation of layer 5-based (L5) approaches in order to improve users’ Quality-of-Experience (QoE). In this paper, we leverage the capabilities of flexible, P4-based switches that incorporate protocol-independent packet processing in order to intelligently route traffic based on application headers. We use Adaptive Bit Rate (ABR) video streaming as an example to show how such an approach can not only provide flexible traffic management but also improve application QoE. Our evaluation consists of an actual deployment in a research testbed, Chameleon, where we leverage the benefits of fast paths in order to retransmit video segments in higher qualities. Further, we analyze real-world ABR streaming sessions from a large-scale CDN and show that our approach can successfully maximize QoE for all users in the dataset.

Bhat, Divyashri↗

The first clinical treatment with kilovoltage intrafraction monitoring (KIM): A real-time image guidance method

Purpose: Kilovoltage intrafraction monitoring (KIM) is a real-time image guidance method that uses widely available radiotherapy technology, i.e., a gantry-mounted x-ray imager. The authors report on the geometric and dosimetric results of the first patient treatment using KIM which occurred on September 16, 2014. Methods: KIM uses current and prior 2D x-ray images to estimate the 3D target position during cancer radiotherapy treatment delivery. KIM software was written to process kilovoltage (kV) images streamed from a standard C-arm linear accelerator with a gantry-mounted kV x-ray imaging system. A 120° pretreatment kV imaging arc was acquired to build the patient-specific 2D to 3D motion correlation. The kV imager was activated during the megavoltage (MV) treatment, a dual arc VMAT prostate treatment, to estimate the 3D prostate position in real-time. All necessary ethics, legal, and regulatory requirements were met for this clinical study. The quality assurance processes were completed and peer reviewed. Results: During treatment, a prostate position offset of nearly 3 mm in the posterior direction was observed with KIM. This position offset did not trigger a gating event. After the treatment, the prostate motion was independently measured using kV/MV triangulation, resulting in a mean difference of less than 0.6 mm and standard deviation of less than 0.6 mm in each direction. The accuracy of the marker segmentation was visually assessed during and after treatment and found to be performing well. During treatment, there were no interruptions due to performance of the KIM software. Conclusions: For the first time, KIM has been used for real-time image guidance during cancer radiotherapy. The measured accuracy and precision were both submillimeter for the first treatment fraction. This clinical translational research milestone paves the way for the broad implementation of real-time image guidance to facilitate the detection and correction of geometric and dosimetric errors, and resultant improved clinical outcomes, in cancer radiotherapy.

60 APPLIED LIFE SCIENCES↗