Search NASA⌕ Search

SEARCH · Search NASA

Results for “software validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Study of Whisper Statistics for Criticality Safety Code Validation

Whisper is computational software designed to assist with validation studies with the Monte Carlo particle transport package MCNP. Historical approaches rely on expert based judgment to select benchmarks while Whisper uses sensitivity/uncertainty (S/U) methods to select relevant benchmarks to a particular application model. Whisper will also derive a calculational margin and margin of subcriticality (MOS) that may be used to generate an upper subcritical limit (USL) for a particular application model. Whisper finds benchmark experiments whose isotope sensitivity profiles align best with the MCNP model in question, and assign a correlation coefficient ('ck' in Whisper parlance) to each selected benchmark as a measure of how closely those profiles agree. When ck values are high, there is less uncertainty between model and benchmarks and a higher USL is possible, relative to cases when ck values are low. The default Whisper settings recommends a 100,000 particles per cycle run for 500 active cycles, resulting in 50 M active neutron histories per application run. This is computationally intensive and may not be necessary to produce accurate results. A Whisper statistical study was done varying the neutron histories per cycle from 10,000 to the default 100,000. A lower number of neutron histories will allow Whisper to be used on low memory systems such as laptops. The intent of this paper is to present the changes in the Whisper results as the number of neutrons histories run is varied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-C-204-06: Monte Carlo Dose Calculation for Kilovoltage X-Ray-Psoralen Activated Cancer Therapy (X-PACT): Preliminary Results

Purpose: X-PACT is an experimental cancer therapy where kV x-rays are used to photo-activate anti-cancer therapeutics through phosphor intermediaries (phosphors that absorb x-rays and re-radiate as UV light). Clinical trials in pet dogs are currently underway (NC State College of Veterinary Medicine) and an essential component is the ability to model the kV dose in these dogs. Here we report the commissioning and characterization of a Monte Carlo (MC) treatment planning simulation tool to calculate X-PACT radiation doses in canine trials. Methods: FLUKA multi-particle MC simulation package was used to simulate a standard X-PACT radiation treatment beam of 80kVp with the Varian OBI x-ray source geometry. The beam quality was verified by comparing measured and simulated attenuation of the beam by various thicknesses of aluminum (2–4.6 mm) under narrow beam conditions (HVL). The beam parameters at commissioning were then corroborated using MC, characterized and verified with empirically collected commissioning data, including: percent depth dose curves (PDD), back-scatter factors (BSF), collimator scatter factor(s), and heel effect, etc. All simulations were conducted for N=30M histories at M=100 iterations. Results: HVL and PDD simulation data agreed with an average percent error of 2.42%±0.33 and 6.03%±1.58, respectively. The mean square error (MSE) values for HVL and PDD (0.07% and 0.50%) were low, as expected; however, longer simulations are required to validate convergence to the expected values. Qualitatively, pre- and post-filtration source spectra matched well with 80kVp references generated via SPEKTR software. Further validation of commissioning data simulation is underway in preparation for first-time 3D dose calculations with canine CBCT data. Conclusion: We have prepared a Monte Carlo simulation capable of accurate dose calculation for use with ongoing X-PACT canine clinical trials. Preliminary results show good agreement with measured data and hold promise for accurate quantification of dose for this novel psoralen X-ray therapy. Funding Support, Disclosures, & Conflict of Interest: The Monte Carlo simulation work was not funded; Drs. Adamson & Oldham have received funding from Immunolight LLC for X-PACT research.

60 APPLIED LIFE SCIENCES↗

Nuclear Energy Advanced Modeling and Simulation (NEAMS) Waste Integrated Performance and Safety Codes (IPSC) : FY10 development and integration.

This report describes the progress in fiscal year 2010 in developing the Waste Integrated Performance and Safety Codes (IPSC) in support of the U.S. Department of Energy (DOE) Office of Nuclear Energy Advanced Modeling and Simulation (NEAMS) Campaign. The goal of the Waste IPSC is to develop an integrated suite of computational modeling and simulation capabilities to quantitatively assess the long-term performance of waste forms in the engineered and geologic environments of a radioactive waste storage or disposal system. The Waste IPSC will provide this simulation capability (1) for a range of disposal concepts, waste form types, engineered repository designs, and geologic settings, (2) for a range of time scales and distances, (3) with appropriate consideration of the inherent uncertainties, and (4) in accordance with robust verification, validation, and software quality requirements. Waste IPSC activities in fiscal year 2010 focused on specifying a challenge problem to demonstrate proof of concept, developing a verification and validation plan, and performing an initial gap analyses to identify candidate codes and tools to support the development and integration of the Waste IPSC. The current Waste IPSC strategy is to acquire and integrate the necessary Waste IPSC capabilities wherever feasible, and develop only those capabilities that cannot be acquired or suitably integrated, verified, or validated. This year-end progress report documents the FY10 status of acquisition, development, and integration of thermal-hydrologic-chemical-mechanical (THCM) code capabilities, frameworks, and enabling tools and infrastructure.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Generalized framework for likelihood-based field-level inference of growth rate from velocity and density fields

Measuring the growth rate of large-scale structures ( f ) as a function of redshift has the potential to break degeneracies between modified gravity and dark energy models, when combined with expansion-rate probes. Direct estimates of peculiar velocities of galaxies have attracted interest as a means of estimating fσ 8 . In particular, field-level methods can be used to fit the field nuisance parameter along with cosmological parameters simultaneously. This article aims to provide the community with a unified framework for the theoretical modeling of the likelihood-based field-level inference by performing fast field covariance calculations for velocity and density fields. Our purpose is to lay the foundations for a nonlinear extension of the likelihood-based method at the field level. We have developed a generalized framework, implemented in the dedicated software flip to perform a likelihood-based inference of fσ 8 . We derived a new field covariance model, which includes wide-angle corrections. We also included the models previously described in the literature inside our framework. We compared their performance against ours, and we validated our model by comparing it with the two-point statistics of a recent N-body simulation. The tests we performed have allowed us to validate our software and determine the appropriate wavenumber range to integrate our covariance model and its validity in terms of separation. Our framework allows for a wider wavenumber coverage to be used in our calculations than in previous works, which is particularly interesting for nonlinear model extensions. Finally, our generalized framework allows us to efficiently perform a survey geometry-dependent Fisher forecast of the fσ 8 parameter. We show that the Fisher forecast method we developed gives an error bar that is 30% closer to a full likelihood-based estimation than a standard volume Fisher forecast.

Ravoux, Corentin↗

HPAC Validation against NRC Documentation

This report describes validation of the radiological source terms in the Nuclear Facility Accident (NFAC) module of the Defense Threat Reduction Agency (DTRA)’s Hazard Prediction and Assessment Capability (HPAC) software. The validation will be conducted by comparing the source terms defined in HPAC to published data from references approved by the U. S. Nuclear Regulatory Commission (NRC). Comparisons will be done for both pressurized water reactors (PWRs) and boiling water reactors (BWRs). This comparison includes the magnitude, isotopic composition, and timing of the release fractions over the course of a severe or moderate accident. Calculations for both facility-specific nuclear power plants and for more generic reactor categories are involved. It is shown that the NFAC radiological source terms in HPAC agree well with NRC standards for moderate and severe accidents at PWRs and BWRs.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

EMPIRICAL VALIDATION OF BUILDING ENERGY SIMULATION SOFTWARE: ENERGYPLUS

This paper compares the results from a study conducted at Iowa Energy Center s Energy Resource Station with EnergyPlus simulation results. The building consists of controlled test rooms, dedicated air handling units and air-cooled chillers for the purpose of obtaining quality data suitable for empirical validation studies. Weather data were also collected at the facility and used for the simulation. Empirical validation can be performed on various levels of the program such as zone level, systems level, and plant level. This study is unique in the sense that it integrates the zones, system, and plant into one analysis. For this study, the difference between empirical and EnergyPlus predicted zone cooling loads varied from 1.7% to 10.2%, but the difference for the compressor power was as much as 22.4%. The paper also describes the potential reasons why simulation results might not match field data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of various approaches for assessing dose indicators and patient organ doses resulting from radiotherapy cone-beam CT

Purpose: The aim of this study was to evaluate various approaches for assessing patient organ doses resulting from radiotherapy cone-beam CT (CBCT), by the use of thermoluminescent dosimeter (TLD) measurements in anthropomorphic phantoms, a Monte Carlo based dose calculation software, and different dose indicators as presently defined. Methods: Dose evaluations were performed on a CBCT Elekta XVI (Elekta, Crawley, UK) for different protocols and anatomical regions. The first part of the study focuses on using PCXMC software (PCXMC 2.0, STUK, Helsinki, Finland) for calculating organ doses, adapting the input parameters to simulate the exposure geometry, and beam dose distribution in an appropriate way. The calculated doses were compared to readouts of TLDs placed in an anthropomorphic Rando phantom. After this validation, the software was used for analyzing organ dose variability associated with patients’ differences in size and gender. At the same time, various dose indicators were evaluated: kerma area product (KAP), cumulative air-kerma at the isocenter (K{sub air}), cone-beam dose index, and central cumulative dose. The latter was evaluated in a single phantom and in a stack of three adjacent computed tomography dose index phantoms. Based on the different dose indicators, a set of coefficients was calculated to estimate organ doses for a range of patient morphologies, using their equivalent diameters. Results: Maximum organ doses were about 1 mGy for head and neck and 25 mGy for chest and pelvis protocols. The differences between PCXMC and TLDs doses were generally below 10% for organs within the field of view and approximately 15% for organs at the boundaries of the radiation beam. When considering patient size and gender variability, differences in organ doses up to 40% were observed especially in the pelvic region; for the organs in the thorax, the maximum differences ranged between 20% and 30%. Phantom dose indexes provided better correlation with organ doses than K{sub air} and KAP, with average ratios ranging between 0.9 and 1.1 and variations for different organs and protocols below 20%. The triple phantom setup allowed us to take into account scatter dose contributions, but nonetheless, the correlation with the evaluated organ doses was not improved with this method. Conclusions: The simulation of rotational geometry and of asymmetric beam distribution by means of PCXMC 2.0 enabled us to determine patient organ doses depending on weight, height and gender. Alternatively, the measurement of an in phantom dose indicator combined with proper correction coefficients can be a useful tool for a first dose estimation of in-field organs. The data and coefficients provided in this study can be applied to any patient undergoing a scan by an Elekta XVI equipment.

60 APPLIED LIFE SCIENCES↗

Mass Spectrometer Transient Analysis

This software implements a complete preprocessing pipeline for transient mass spectrometry (MS) data collected during TAP (Temporal Analysis of Products) experiments. It is designed to extract chemically meaningful fluxes from overlapping ion signals by applying a calibrated defragmentation matrix and solving the resulting linear system using non-negative least squares (NNLS) regression. The core script, preprocess_mass_spec.py, performs the following operations: Gain correction: Applies amplifier gain scalars derived from inert-packed calibration pulses to normalize signal intensities across AMUs and acquisition settings. Background subtraction: Removes experiment baselines using user-defined time windows, ensuring compatibility with slow-diffusing species and preventing negative values that would interfere with NNLS. Options to subtract before and after defragmentation. Defragmentation: Constructs a fragmentation matrix A from zeroth moments of calibration pulses (equal molar gas:inert mixtures) and solves Ax=b at each time point, where b is the raw MS signal and x is the estimated species flux. The matrix is normalized to inert signals and accounts for instrument-specific fragmentation behavior. Pulse-mode handling: Supports both averaged and individual pulse modes, enabling statistical treatment of fluxes and calculation of standard deviations. Integration and output: Computes zeroth moments (integrated fluxes) and exports time-resolved and integrated data in CSV format, suitable for downstream kinetic modeling. The software is validated using both virtual TAP simulations (VTAP) and experimental data from propane dehydrogenation (PDH) on CrOx/Al2O3 catalysts. It preserves temporal resolution by applying NNLS point-by-point across the pulse duration (typically 6,000+ time slices per pulse), leveraging the linear superposition principle to reconstruct full flux profiles. The defragmented outputs are compatible with kinetic extraction methods such as the G and Y procedures, which are used to derive rate–concentration relationships from TAP data. The details of these validations are discussed in detail in the supporting manuscript and supporting information. Example data and output files are also included. The methodology is robust to experimental noise and drift, with calibration protocols that account for pulse size effects, MS aging, and inert gas normalization. The software is modular, reproducible, and tailored for high-throughput TAP-MS workflows in catalysis research.

Kristy, Stephen [Idaho National Laboratory (INL), ↗

MS–STEM–FEM: A parallelized multi-slice fluctuation TEM simulation tool

Atomic configurations of glassy or amorphous materials containing medium-range order (MRO) may be identified by comparing fluctuation transmission electron microscopy (FTEM) measurements to FTEM simulations obtained using model configurations. Candidate model sizes have traditionally been much thinner than the samples measured experimentally, and publicly available FTEM simulation software has until now omitted microscope parameters, dynamical scattering, and the phase of the diffracted electron wave. We introduce MS–STEM–FEM, an open-source software package for simulating FTEM experiments using established multi-slice TEM simulation techniques to emulate experiment more closely by incorporating microscope parameters and simulating electron scattering and propagation as a complex valued wave. Simulations using established models are compared with results of experimental STEM–FEM to validate the software. Several statistical measures of diffraction are implemented and their responses to model features are compared. Dynamical scattering is found to be less influential than the variety of crystallite orientations which occur in thicker models. Simulations of variable resolution microscopy confirm that cumulative intensity of the FTEM signal decreases with reduced model MRO and increased coherence volume. In conclusion, advantageous model scaling characteristics and efficient processor performance scaling are demonstrated, along with a study of convergence with respect to pertinent simulation parameters to identify accuracy requirements.

36 MATERIALS SCIENCE↗

2.2.2.405 - Verdant/NREL Research Measurement Campaign

The marine renewable energy industry primarily uses thermoset composite materials for blades and other hydrodynamic components, which can have up to 50% reduction in strength when exposed to seawater and are not recyclable. Thermoplastic composite materials have been shown at a coupon-scale to have improved seawater saturated properties but have not been validated at full scale. The primary goal of the project is to demonstrate the structural properties of thermoplastic-fiberglass composite blades compared to epoxy-fiberglass composite blades in seawater at a tidal energy site on an operational turbine. Through this work, NREL manufactured, tested and deployed thermoplastic blades and a data acquisition system on Verdant Power's turbine TriFrame in the East River, NYC. The thermoplastic blades and DAQ were retrieved after a 6-month deployment with no signs of degradation and all cable connections, structural supports and strain gages had a 100% survival rate. The blades are currently undergoing post-deployment structural validation to compare their performance to traditional epoxy blades that were deployed for the same amount of time. This will increase confidence in thermoplastic materials and move it closer to commercial adoption, as well as increase confidence in the design of a DAQ and instrumentation method for a tidal turbine. However, due to an error in the DAQ software that was introduced after the DAQ and software were validated, there was no loads data collected during the deployment.

blade testing↗

Biomaniac

Los Alamos National Laboratory researchers are developing a machine-learning based algorithm to revolutionize how biopolymers are designed and optimized. BioManIAC is a software platform that fills the gaps in data to gain insight into new potential polymer properties without making and testing them. Polymer engineers are able to use BioManIAC software to extrapolate and tune new biopolymer properties that allow the user to create small smart libraries, rather than largescale trial and error testing. This targeted design is expected to improve both time to market and R&D expenditure, as well as the resulting mechanical properties of biopolymers, enabling for more direct competition with traditional petroleum-based polymers. Los Alamos is seeking partners to further validate our software platform.

36 MATERIALS SCIENCE↗

RUScal : Software for the analysis of resonant ultrasound spectroscopy measurements

Resonant ultrasound spectroscopy is used to nondestructively measure the elastic resonances of small solids to elucidate the material's elastic properties or other qualities like size, shape, or composition. In this work, we introduce the software RUScal for the purpose of determining elastic properties by analyzing the eigenfrequencies of solid specimens with common shapes, such as rectangular parallelepipeds, cylinders (solid and hollow tube), ellipsoids, and octahedrons, as well as irregularly shaped ellipsoids that can be described analytically. All symmetry classes are supported, from isotropic to triclinic, along with the option to add or remove up to three orthogonal mirror planes as well as the ability to reorient the crystal axes with respect the sample edges via Euler angles. Additional features include tools to help find initial sets of elastic constants, including grid exploration and Monte Carlo methods, a tool to analyze frequencies as a function of sample length or crystal orientation, an error analysis tool to assess fit quality, and formatting of the input and output files for batch fitting, e.g., as a function of temperature. This software was validated with published resonant ultrasound spectroscopy data for various materials, shapes, and symmetries with noted improvements in calculation time compared to finite element methods.

47 OTHER INSTRUMENTATION↗

Free software for performing physical analysis of systems for digital radiography and mammography

Purpose: In this paper, the authors present a free software for assisting users in achieving the physical characterization of x-ray digital systems and image quality checks. Methods: The program was developed as a plugin of a well-known public-domain suite ImageJ. The software can assist users in calculating various physical parameters such as the response curve (also termed signal transfer property), modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE). It also includes the computation of some image quality checks: defective pixel analysis, uniformity, dark analysis, and lag. Results: The software was made available in 2009 and has been used during the last couple of years by many users who gave us valuable feedback for improving its usability. It was tested for achieving the physical characterization of several clinical systems for digital radiography and mammography. Various published papers made use of the outcomes of the plugin. Conclusions: This software is potentially beneficial to a variety of users: physicists working in hospitals, staff working in radiological departments, such as medical physicists, physicians, engineers. The plugin, together with a brief user manual, are freely available and can be found online ( http://www.medphys.it/downloads.htm ). With our plugin users can estimate all three most important parameters used for physical characterization (MTF, NPS, and also DQE). The plugin can run on any operating system equipped with ImageJ suite. The authors validated the software by comparing MTF and NPS curves on a common set of images with those obtained with other dedicated programs, achieving a very good agreement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-212: Influence of the Modulation Index On Daily Quality Assurance in Rapid Arc Treatments

Purpose: At our Institute some measured parameters for daily quality assurance (DQA) of dynamic arc therapy plans showed an unexpected behavior, therefore an investigation of the influence of the magnitude of modulation was conducted. Methods: In our clinical practice all DQAs of dynamic arc therapy plans are measured and analyzed prior to treatments using commercial software. For this study these plans were additionally exported to our in-house software written in MATLAB.The developed software extracted the leaf position, gantry angle, cumulative meterset weight of each control point (CP) and the total number of Monitor Units (MU) of each arc. Based on this information we calculated the leaf travel distance, irradiated segment area, number of MUs and dose rate for each CP. These data allowed us to calculate the modulation indexes (MI) of the plans, applying five different definitions of MI. The results were then correlated to the results of our DQA measurements.To validate the software, additional plans of known MIs were created and analyzed. For confirmation, the calculated parameters were compared to the segmented treatment table (STT) coming from the treatment planning system. Results: All calculated CP-parameters matched the STT by 99% or better. For linac 1, the comparison of the MI evaluation and the DQA results showed a slight tendency: 91.3% failed DQA plans had a MI lower than the average value. For this definition we consider that the lower the MI the higher the modulation. The results of the linac 2 present no significant relevance due to the low sample sizes for each DQA software. Conclusion: Available data and given definitions of the modulation index do not bring conclusive results; one cannot find a clear and distinct correlation with the failure of the DQA. The ongoing analysis with an increased sample size might lead to another conclusion.

07 ISOTOPE AND RADIATION SOURCES↗

Nuclear Energy Advanced Modeling and Simulation (NEAMS) waste Integrated Performance and Safety Codes (IPSC) : gap analysis for high fidelity and performance assessment code development.

This report describes a gap analysis performed in the process of developing the Waste Integrated Performance and Safety Codes (IPSC) in support of the U.S. Department of Energy (DOE) Office of Nuclear Energy Advanced Modeling and Simulation (NEAMS) Campaign. The goal of the Waste IPSC is to develop an integrated suite of computational modeling and simulation capabilities to quantitatively assess the long-term performance of waste forms in the engineered and geologic environments of a radioactive waste storage or disposal system. The Waste IPSC will provide this simulation capability (1) for a range of disposal concepts, waste form types, engineered repository designs, and geologic settings, (2) for a range of time scales and distances, (3) with appropriate consideration of the inherent uncertainties, and (4) in accordance with rigorous verification, validation, and software quality requirements. The gap analyses documented in this report were are performed during an initial gap analysis to identify candidate codes and tools to support the development and integration of the Waste IPSC, and during follow-on activities that delved into more detailed assessments of the various codes that were acquired, studied, and tested. The current Waste IPSC strategy is to acquire and integrate the necessary Waste IPSC capabilities wherever feasible, and develop only those capabilities that cannot be acquired or suitably integrated, verified, or validated. The gap analysis indicates that significant capabilities may already exist in the existing THC codes although there is no single code able to fully account for all physical and chemical processes involved in a waste disposal system. Large gaps exist in modeling chemical processes and their couplings with other processes. The coupling of chemical processes with flow transport and mechanical deformation remains challenging. The data for extreme environments (e.g., for elevated temperature and high ionic strength media) that are needed for repository modeling are severely lacking. In addition, most of existing reactive transport codes were developed for non-radioactive contaminants, and they need to be adapted to account for radionuclide decay and in-growth. The accessibility to the source codes is generally limited. Because the problems of interest for the Waste IPSC are likely to result in relatively large computational models, a compact memory-usage footprint and a fast/robust solution procedure will be needed. A robust massively parallel processing (MPP) capability will also be required to provide reasonable turnaround times on the analyses that will be performed with the code. A performance assessment (PA) calculation for a waste disposal system generally requires a large number (hundreds to thousands) of model simulations to quantify the effect of model parameter uncertainties on the predicted repository performance. A set of codes for a PA calculation must be sufficiently robust and fast in terms of code execution. A PA system as a whole must be able to provide multiple alternative models for a specific set of physical/chemical processes, so that the users can choose various levels of modeling complexity based on their modeling needs. This requires PA codes, preferably, to be highly modularized. Most of the existing codes have difficulties meeting these requirements. Based on the gap analysis results, we have made the following recommendations for the code selection and code development for the NEAMS waste IPSC: (1) build fully coupled high-fidelity THCMBR codes using the existing SIERRA codes (e.g., ARIA and ADAGIO) and platform, (2) use DAKOTA to build an enhanced performance assessment system (EPAS), and build a modular code architecture and key code modules for performance assessments. The key chemical calculation modules will be built by expanding the existing CANTERA capabilities as well as by extracting useful components from other existing codes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automating crystallographic structure solution and refinement of protein–ligand complexes

A software system for automated protein–ligand crystallography has been implemented in the Phenix suite. This significantly reduces the manual effort required in high-throughput crystallographic studies. High-throughput drug-discovery and mechanistic studies often require the determination of multiple related crystal structures that only differ in the bound ligands, point mutations in the protein sequence and minor conformational changes. If performed manually, solution and refinement requires extensive repetition of the same tasks for each structure. To accelerate this process and minimize manual effort, a pipeline encompassing all stages of ligand building and refinement, starting from integrated and scaled diffraction intensities, has been implemented in Phenix. The resulting system is able to successfully solve and refine large collections of structures in parallel without extensive user intervention prior to the final stages of model completion and validation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range

Purpose: Photon dosimetry in the kilovolt (kV) energy range represents a major challenge for diagnostic and interventional radiology and superficial therapy. Plastic scintillation detectors (PSDs) are potentially good candidates for this task. This study proposes a simple way to obtain accurate correction factors to compensate for the response of PSDs to photon energies between 80 and 150 kVp. The performance of PSDs is also investigated to determine their potential usefulness in the diagnostic energy range. Methods: A 1-mm-diameter, 10-mm-long PSD was irradiated by a Therapax SXT 150 unit using five different beam qualities made of tube potentials ranging from 80 to 150 kVp and filtration thickness ranging from 0.8 to 0.2 mmAl + 1.0 mmCu. The light emitted by the detector was collected using an 8-m-long optical fiber and a polychromatic photodiode, which converted the scintillation photons to an electrical current. The PSD response was compared with the reference free air dose rate measured with a calibrated Farmer NE2571 ionization chamber. PSD measurements were corrected using spectra-weighted corrections, accounting for mass energy-absorption coefficient differences between the sensitive volumes of the ionization chamber and the PSD, as suggested by large cavity theory (LCT). Beam spectra were obtained from x-ray simulation software and validated experimentally using a CdTe spectrometer. Correction factors were also obtained using Monte Carlo (MC) simulations. Percent depth dose (PDD) measurements were compensated for beam hardening using the LCT correction method. These PDD measurements were compared with uncorrected PSD data, PDD measurements obtained using Gafchromic films, Monte Carlo simulations, and previous data. Results: For each beam quality used, the authors observed an increase of the energy response with effective energy when no correction was applied to the PSD response. Using the LCT correction, the PSD response was almost energy independent, with a residual 2.1% coefficient of variation (COV) over the 80-150-kVp energy range. Monte Carlo corrections reduced the COV to 1.4% over this energy range. All PDD measurements were in good agreement with one another except for the uncorrected PSD data, in which an over-response was observed with depth (13% at 10 cm with a 100 kVp beam), showing that beam hardening had a non-negligible effect on the PSD response. A correction based on LCT compensated very well for this effect, reducing the over-response to 3%.Conclusion: In the diagnostic energy range, PSDs show high-energy dependence, which can be corrected using spectra-weighted mass energy-absorption coefficients, showing no considerable sign of quenching between these energies. Correction factors obtained by Monte Carlo simulations confirm that the approximations made by LCT corrections are valid. Thus, PSDs could be useful for real-time dosimetry in radiology applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗