Search NASA⌕ Search

SEARCH · Search NASA

Results for “solar inverters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Development of Lattice-Mismatched GaInAsP for Radiation Hardness

We develop lattice-mismatched GaInAsP as an alternative alloy to pure As-based alloys currently used in III-V multijunction solar cells. Increasing the alloy phosphorous and indium content while maintaining an optimal bandgap may allow high efficiency multijunction devices with increased radiation hardness. Here, 1.0-eV GaInAsP is developed and implemented into single and multijunction solar cell devices. The lattice-mismatched GaInAsP must be grown strain free, and the subcell thickness must be maintained below the thickness where surface-driven phase separation occurs. As observed in transmission electron microscopy and cathodoluminescence imaging, phase separation strengthens in the GaInAsP layer and leads to interfacial defect formation when the cell thickness is too great. We show single junction 1.0-eV Ga 0.5 In 0.5 As 0.7 P 0.3 with excellent carrier collection and a bandgap-voltage offset of 0.40 V. This material quality approaches that of 1.0-eV Ga 0.7 In 0.3 As used in inverted metamorphic multijunction devices, but has increased phosphorus content and consequently is expected to have a higher radiation resistance. We incorporate the 1.0-eV GaInAsP subcell into a 3-junction inverted metamorphic solar cell to test the performance of the subcell in a multijunction. No additional loss is observed upon integration into a multijunction cell: both the carrier collection and voltage of the GaInAsP subcell are unchanged from single junction devices. While further materials development and radiation testing is still required, these preliminary results indicate that lattice-mismatched GaInAsP can be effectively used in multijunction solar cells to replace radiation-soft materials.

14 SOLAR ENERGY↗

Mitigating Phase Unbalance for Distribution Systems with High Penetrations of Solar PV (Final Technical Report)

Distribution system operators have traditionally limited unbalance among phases by maintaining similar loadings on each phase. High penetrations of distributed solar PV continually change the net loading on each phase, resulting in time-varying phase unbalances that can damage three-phase devices such as three-phase motors, violate grid codes, and increase technical losses. This project has developed several control strategies for the reactive power outputs of solar PV inverters in order to mitigate power quality issues related to phase unbalance. These control strategies include a decentralized approach that is solely based on local measurements, distributed and grouped approaches that consider subsets of loads and PV generators, and a centralized approach that leverages measurements from a variety of locations in order to compute optimal reactive power setpoints for each inverter. Variants of the controllers handle challenges relevant to practical implementations, including noisy measurements, delayed communications, and reactive power limits. Moreover, the project developed theory that provides convergence guarantees for systems with multiple interacting controllers as well as “balanceability” certificates that ensure satisfaction of phase unbalance requirements with variable loading. The controllers were integrated with NRECA’s Open Modeling Framework (omf.coop) and evaluated using actual distribution system models obtained from several NRECA member utilities. Application of the controllers results in significant improvements to phase unbalance in these test cases with decreases from base case levels of over 3% to under 0.5%, which is within the 2% IEC phase unbalance standard.

14 SOLAR ENERGY↗

Utility-Scale Operational Consequences for Solar Grid Services

This report delves into the critical aspects of grid services provided by solar inverter-based resources (IBRs), with an emphasis on the evolving landscape of microgrids, virtual power plants (VPPs), aggregators, and distributed energy resource management systems (DERMS). As the energy sector undergoes a transformative shift towards more decentralized and resilient grid architectures, understanding the multifaceted risks associated with these technologies becomes paramount. The report categorizes these risks into organizational, technical, and procedural domains, providing a thorough risk assessment framework that stakeholders can utilize to anticipate and mitigate potential issues. In addressing the increasing complexity of grid interconnections, the report highlights the importance of Cyber-Informed Engineering (CIE). By embedding engineering controls and cybersecurity measures into the early stages of system design, this approach aims to fortify grid infrastructure against emerging cyber threats. The analysis includes an exploration of best practices and strategies for integrating CIE principles to enhance grid security and resilience. To provide practical insights, the report conducts a detailed consequence analysis of various grid services and cyber mitigations that can be applied through the interconnection process. This analysis evaluates the potential impacts of different failure modes and vulnerabilities, offering a clear understanding of the consequences that could arise from disruptions within the energy grid. The findings are further enriched by a series of case studies that illustrate real-world scenarios and lessons learned from past incidents. Through this comprehensive examination of grid services and their criticality, the report aims to prepare industry professionals with the knowledge and tools necessary to navigate the complexities of modern energy systems. By providing a comprehensive approach that includes risk assessment, cybersecurity, and consequence analysis, solar stakeholders can more effectively guarantee the reliability, efficiency, and security of the energy grid.

14 SOLAR ENERGY↗

Guided Optimization of Phase-Unstable III–V Compositionally Graded Buffers by Cathodoluminescence Spectrum Imaging

Compositionally graded buffers (CGBs) are essential components of high-efficiency III-V inverted metamorphic solar cells, and high-quality CGBs with low defect densities are a requirement for high device efficiencies. Here, we use plan-view and cross-sectional cathodoluminescence spectrum imaging (CLSI) to investigate the effect of growth conditions on the microstructure of Al y Ga 1-x-y In x AS CGBs with x In > 0.30. CLSI reveals significant compositional fluctuation in these materials that correlates with the distribution of threading dislocations in the CGBs. Threading dislocations are observed to collect in regions between abrupt transitions in emission energy, implying that concomitant strain fluctuations in these regions restrict dislocation motion. Thus, the compositional fluctuation leads to elevated threading dislocation densities that degrade CGB quality. We also correlate compositional fluctuation in the CGB with compositional fluctuation in subsequently grown device layers. The effectiveness of specific growth conditions at suppressing compositional fluctuation and limiting threading dislocation density is evaluated. CGBs grown at high temperatures with high Al content exhibit the lowest defect densities. The use of a high V/III ratio suppresses compositional fluctuation and defect density. In conclusion, these insights lead directly to improvements in the efficiency of metamorphic Ga 1-x In x As solar cells grown on AlyGa 1-x-y In x As CGBs.

14 SOLAR ENERGY↗

Detection and Diagnosis of Data Integrity Attacks in Solar Farms Based on Multilayer Long Short-Term Memory Network

Photovoltaic (PV) systems are becoming more vulnerable to cyber threats. In response to this emerging concern, developing cyber-secure power electronics converters has received increased attention from the IEEE Power Electronics Society that recently launched a cyber-physical-security initiative. Here this letter proposes a deep sequence learning based diagnosis solution for data integrity attacks on PV systems in smart grids, including dc–dc and dc–ac converters. The multilayer long short-term memory networks are used to leverage time-series electric waveform data from current and voltage sensors in PV systems. The proposed method has been evaluated in a PV smart grid benchmark model with extensive quantitative analysis. As a comparison, we have evaluated classic data-driven methods, including K-nearest neighbor, decision tree, support vector machine, artificial neural network, and convolutional neural network. Comparison results verify performances of the proposed method for detection and diagnosis of various data integrity attacks on PV systems.

42 ENGINEERING↗

Security assessment and impact analysis of cyberattacks in integrated T&D power systems

In this paper, we examine the impact of cyberattacks in an integrated transmission and distribution (T&D) power grid model with distributed energy resource (DER) integration. We adopt the OCTAVE Allegro methodology to identify critical system assets, enumerate potential threats, analyze and prioritize risks for threat scenarios. Based on the analysis, attack strategies and exploitation scenarios are identified which could lead to system compromise. Specifically, we investigate the impact of data integrity attacks in inverted-based solar PV controllers, control signal blocking attacks in protective switches and breakers, and coordinated monitoring and switching time-delay attacks. Index Terms—Cyberattacks, security assessment, impact analysis, case studies, integrated power systems.

14 SOLAR ENERGY↗

Moisture Ingress Models of Film Capacitors in PV Inverters

This presentation discusses the methodology for developing moisture ingress models for components inside a PV inverter. This method uses time series-based analyses for moisture ingress unlike a single maximum temperature, humidity, and voltage setpoint used in Hallberg-Peck equations. Experiments were performed for determination of moisture ingress time to estimate moisture ingress in and out of the capacitor device under normal and extreme temperatures and RH conditions.

film capacitors↗

Quasi-Static Time Series Fatigue Simulation for PV Inverter Semiconductors with Long-Term Solar Profile

Power system simulations with long-term data tend to have large time steps varying from one second to a few minutes. However, for PV inverter semiconductors, the minimum thermal stresses cycle is with line frequency. This requires the time step of the fatigue simulation to be much smaller than the line period. This small time step results in poor simulation speed, especially for long-term simulations. This paper proposes a fast fatigue simulation for inverter semiconductors using the quasi-static time series (QSTS) simulation concept. The fatigue analysis typically focuses on the peak and valley values of a strain and neglect the transients from peaks to valleys. The proposed simulation utilizes this property of fatigue analysis and calculates the steady state of the semiconductor junction temperature only. The resulting time step of the fatigue simulation is 15 minutes, which is consistent with the solar dataset without losing accuracy.

fast simulation↗

Multilevel Cybersecurity for Photovoltaic Systems

The motivation behind this project is to protect critical infrastructure in electric power generation pertaining to solar photovoltaic (PV) systems. This growing renewable energy resource is becoming a more vital part of the nation’s energy portfolio, particularly since it has achieved grid-parity to existing generation methods in terms of cost. It is thus vital that steps be taken to ensure the cybersecurity of these assets. The project goal was to devise a multilevel cybersecurity solution to address PV security gaps at the inverter and system levels, and field test the solution under the supervision and review of a US-based solar inverter manufacturer and PV installer/operator. A two-level cyberattack defense approach was formulated whereby the first level, the solar inverter level, hardens individual devices and achieves a deeply cyber-secure inverter. The inverter level security involves a multi-layer defense-in-depth approach for securing the inverter while also providing data for the system level algorithms. The second level, the system level, addresses intrusion detection and restoration involving an ensemble of inverters and relevant systems.

14 SOLAR ENERGY↗

An Optimized H5 Hysteresis Current Control with Clamped Diodes in Transformer-Less Grid-PV Inverter

With the rise of renewable energy penetration in the grid, photovoltaic (PV) panels are connected to the grid via inverters to supply solar energy. Transformer-less grid-tied PV inverters are gaining popularity because of their improved efficiency, reduced size, and lower costs. However, they can induce a path for leakage currents between the PV and the grid due to the absence of galvanic isolation. This leads to serious electromagnetic interference, loss in efficiency, and safety concerns. The leakage current is primarily influenced by the nature of the common mode voltage (CMV), which is determined by the switching techniques of the inverter. In this paper, a novel inverter topology of Hysteresis Controlled H5 with Two Clamping Diodes (HCH5-D2) is derived. The HCH5-D2 topology helps decouple the AC part (Grid) and DC part (PV) during the freewheeling period to make the CMV constant, thereby reducing the leakage current. Additionally, the extra diodes help reduce voltage spikes generated during the freewheeling period and maintain the CMV at a constant value. Finally, a 2.2 kW grid-connected single-phase HCH5-D2 PV inverter system’s MATLAB simulation is presented, showing better results compared to a traditional H4 inverter.

42 ENGINEERING↗

Verification of Adaptive Protection in Hardware in the Loop for Coordination with Solar Variability

As inverter-based resources continue to be installed at all levels of the electric grid, the fixed protection schemes used at the distribution level will continue to be stressed until they no longer ensure the protection of the grid. Adaptive protection has been proposed as a solution with the ability to update the protection schemes in near real-time to ensure reliability and increase the resilience of the grid. However, weather variability poses a significant challenge to the ability of these methods to keep the selectivity and reliability of these schemes coordinated. If the ramp rates, due to solar variability, of the inverter-based resources change faster than the adaptive protection can issue new settings, the protection system could be uncoordinated, with the wrong device responding to a system fault. The proposed adaptive protection method ensures that due to solar variability, communication, and protection calculation latency, it can issu e coordinated protection settings promptly, in one minute or less. The hardware-in-the-loop results show the protection settings being issued and maintaining system coordination in under a minute.

Summers, Adam↗

Automating the Solar Interconnection Technical Evaluation Process: PREconfiguring and Controlling Inverter SEt-Points (PRECISE)

Utilities are receiving an increasing number of interconnection requests for distributed solar photovoltaic (PV) systems from their customers, requiring a solution to quickly and intelligently perform technical assessments of these requests and to manage these new renewable energy assets. In this paper, we present a stand-alone interconnection tool, PREconfiguring and Controlling Inverter SEt-points (PRECISETM), and how it overcomes the challenges of accelerating technical evaluations and leverages smart inverter functionality to provide local voltage support on an as-needed basis. The paper details the purpose and architecture of PRECISE, including tools, data source requirements, the model-based interconnection evaluation process, and technical results. PRECISE is an integrated software tool that customizes PV inverter settings for utilities by modeling and assessing impacts on local voltages and the need for advanced inverter functions (AIFs) (e.g., volt-VAR and volt-watt). PRECISE maximizes the use of readily available utility data sets to make fast online assessments of incoming PV interconnection requests and makes accept/reject recommendations along with custom settings for AIFs.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Protection and Restoration Solutions to Reliable and Resilient Integration of Grid-connected PV Installations and Distributed Energy Resources: Design, Testbed, Proof of Work and Impact Studies (Final Report)

To gain a better understanding of the complex transients in a utility grid with a large number of solar PV installations coupled by PWM inverters during the protection and restoration period of the power grid, in this project a kW-level experimental system with dominating inverter-based resources and a hardware-in-loop simulation system with transmission and distribution models, as well as several SEL protective relays have been built and used. The major research findings of the project are summarized below in two perspectives: Experimental research: A self-organized ultra-high frequency solitary waveform is discovered and demonstrated in the hardware experimental system. Despite the familiarities, such a solitary waveform is distinct from any harmonics, transient, or resonance waves in that, it is 1) non-dispersive over time and space, 2) not associated with any active source or the linear superposition of sources, 3) half-cycle asymmetric, 4) not responding to filters or change of system characteristic resonance frequency, 5) ubiquitous as it occurs simultaneously everywhere in the system from DC supply, power lines, and the utility grid, and 6) explosive through tripping the protection or damaging susceptible devices or circuits. Analytical study: The nature of such a new waveform and an analytical explanation of its formation are studied based on related physics and non-linear science principles, with the following highlights: 1) such a new waveform follows the solutions to the Non-linear Schrödinger equation, so the classic linear perturbation theory is unable to explain or predict such a unique waveform as confirmed with the research team of RTDS; 2) the critical condition of occurrence of such a waveform is derived, which indicates that the breakings of solitary wave is a system synchronous issue between the utility grid in the 60Hz phasor domain and duty-ratio modulation of DC sources in the inverter switching frequency domain; 3) such a waveform carries energy mass so it could be detrimental; 4) such a waveform is deceiving as it is not readily detectable in the energy propagation direction by the primary protection equipment, while it is detrimental in the perpendicular direction of energy propagation, i.e. voltage direction. Thus, it has more likely challenges to the second primary equipment and devices, particularly at the weakest link and point such as aging insulation and inappropriate setting of susceptible devices. Therefore, such a waveform can be easily ignored in the aftermath investigation. The intellectual merits: The experimental discovery reveals certain unfamiliar transient phenomena that could challenge the integration of large-scale grid-connected solar PV installation during the group ride-through period of solar PV installations, commissioning of large-solar farms, or dramatic change of solar radiation conditions. Particularly, the research findings suggest that the occurrence of the unfamiliar transient phenomena is uniquely associated with the inverter-based solar PV installation, which is less likely to happen for rotary energy systems. The physics and non-linear science-based research work laid down an analytical path to the challenging transient stability problems including those that have been observed currently and future calls. Both experimental and analytical research results explain the limitation of many current research effects including some DoE research undertakings as well as possible solutions. The broader impacts: The research outcome of the project advances the understanding of the possible transient problems for the integration of inverter-based solar PV installation. It also highlights the theoretical and technical barriers for applying the conventional theory and technology to design and implement countermeasures against their adverse impacts of the large-scale solar PV installation and operation on grid reliability and security. More broadly, the research outcomes have shed some light on the open, fundamental challenges in the integration of large-scale solar photovoltaic energy into current and next-generation power grids across the country, and worldwide. The advanced physics and non-linear science-based analysis open up a path to harmonization of the renewables for societal energy needs via building a resilient and sustainable electric power infrastructure.

14 SOLAR ENERGY↗

Use of Hardware-in-the-Loop to De-Risk Field Deployment of Hydrogen Assets

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

08 HYDROGEN↗