Search NASA⌕ Search

SEARCH · Search NASA

Results for “solid state physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

X-ray color analysis of the spectra of active galactic nuclei

The identification and detection of X-ray absorption and emission features depends on the resolution and the signal-to-noise ratio (S/N) of the observation, the understanding of the instrument response, and the Galactic line-of-sight absorption. Since many of the active galactic nucleus (AGN) data sets are limited in their S/N and full modeling of the physical conditions is rather complicated, we suggest a new analysis method based on 'X-ray colors.' The two sets of X-ray colors, defined for low (ROSAT Position Sensitive Proportional Counter (PSPC)) and medium (Broad Band X-Ray Telescope (BBXRT)) and ASCA Solid-State Imaging Spectrometers (SIS) resolution experiments, are used to separate regions of different physical conditions in a two-dimensional color-color plane. They are similar but superior to previous methods using the X-ray 'hardness ratio' in being able to reveal more of the physical properties of the source. We illustrate the use of such diagrams by studying a number of AGNs suspected of showing absorption features. A sample of 14 AGNs observed by the ROSAT PSPC is presented which includes several objects with suspected 'warm absorbers' along the line-of-sight to the nucleus, several others exhibiting intrinsic continuum variations, and a number of control objects thought to be featureless. Our new observations show, for the first time, the color variation as a function of time for three of the Seyfert 1 sources: NGC 4051, Mrk 335, and Mrk 766. The variations suggest that in two sources we are witnessing real changes in continuum shape, while one (NGC 4051) is consistent with having a warm absorber. Four of the objects observed by BBXRT are reanalyzed using our X-ray colors. Out of these, we discuss in detail the case of NGC 4151 and show that the color-color analysis agrees very well with previous, detailed spectral fitting methods. In particular, we confirm that the observed BBXRT observation of this source is not consistent with the warm absorber explanation and must be interpreted as a combination of a variable hard component and another component. We explain the limitations in measuring low-energy emission features in ASCA SIS observations and present color-color diagrams which can be used as a powerful diagnostic tool in the analysis of data collected by this experiment.

Netzer, Hagai↗

QuakeSim and the Solid Earth Research Virtual Observatory

We are developing simulation and analysis tools in order to develop a solid Earth science framework for understanding and studying active tectonic and earthquake processes. The goal of QuakeSim and its extension, the Solid Earth Research Virtual Observatory (SERVO), is to study the physics of earthquakes using state-of-the-art modeling, data manipulation, and pattern recognition technologies. We are developing clearly defined accessible data formats and code protocols as inputs to simulations, which are adapted to high-performance computers. The solid Earth system is extremely complex and nonlinear resulting in computationally intensive problems with millions of unknowns. With these tools it will be possible to construct the more complex models and simulations necessary to develop hazard assessment systems critical for reducing future losses from major earthquakes. We are using Web (Grid) service technology to demonstrate the assimilation of multiple distributed data sources (a typical data grid problem) into a major parallel high-performance computing earthquake forecasting code. Such a linkage of Geoinformatics with Geocomplexity demonstrates the value of the Solid Earth Research Virtual Observatory (SERVO) Grid concept, and advances Grid technology by building the first real-time large-scale data assimilation grid.

virtual observatory↗

Solid-State Ultracapacitor Polymer Composite

An ultracapacitor made from a polymer loaded with ceramic powder would have several advantages over current ultracapacitors and batteries. First is the possibility of it being printable, which would allow for printing the energy storage device along with the circuit instead of having to find a way to add one later without damaging the rest of the components. When not printed in a specific design for use on a printed wiring board, this type of ultracapacitor could still be cured via a mold to a shape suitable to specific applications. Many polymers maintain some flexibility even after curing, such as the silicone used in this study. The manufacturing process would also be far simpler than that of conventional ultracapacitors.In this work, solid-state ultracapacitors were made by adding the dielectric powder to a two-part polymer (resin and hardener) at the same time. The mixture was then cured in the desired shape at a low temperature until completely set. The addition of the powder to the polymer increased its dielectric properties while leaving most of its physical properties unaltered. At higher powder loading percentages, there were some physical changes as the maximum loading point was approached. To determine the efficiency of these solid-state ultracapacitors, their capacitances were tested, and their dielectric constants (DCs) were measured and compared.

energy storage↗

Wireless Temperature-Monitoring System

A relatively inexpensive instrumentation system that includes units that are connected to thermocouples and that are parts of a radio-communication network has been developed to enable monitoring of temperatures at multiple locations. Because there is no need to string wires or cables for communication, the system is well suited for monitoring temperatures at remote locations and for applications in which frequent changes of monitored or monitoring locations are needed. The system can also be adapted to monitoring of slowly varying physical quantities, other than temperature, that can be transduced by solid-state electronic sensors. electronic sensors. The system comprises any number of transmitting units and a single receiving unit. Each transmitting unit includes connections for as many as four external thermocouples, a signal-conditioning module, a control module, and a radio-communication module. The signal-conditioning module acts as an interface between the thermocouples and the rest of the transmitting unit and includes a built-in solid ambient temperature sensor that is in addition to the external thermocouples. The control module is a system-on-chip embedded processor that includes analog-to-digital converters, serial and parallel data ports, and an interface for local connection to an analog meter that is used during installation to verify correct operation. The radio-communication module contains a commercial spread-spectrum transceiver that operates in the 900-MHz industrial, scientific, and medical (ISM) frequency band. This transceiver transmits data to the receiving unit at a rate of 19,200 baud. The receiving unit includes a transceiver like that of a transmitting unit, plus a control module that contains a system-on-chip processor that includes serial data port for output to a computer that runs monitoring and/or control software, a parallel data port for output to a printer, and a seven-segment light-emitting-diode display. Each transmitting unit is battery-powered and can operate for at least seven days continuously while reporting temperatures every half hour. The receiving unit is powered by a wall-mounted transformer source. The receiving unit responds to each transmitting unit and reports the readings of each of the four thermocouples and of the ambient-temperature sensor of the transmitting unit. The end-to-end accuracy of the system is plus or minus 0.2 C over the temperature range from 0 to 100 C. The radio-communication range between the receiving and transmitting units is approximately equal to 0.5 mile (approximately equal to 0.8 km).

Solano, Wanda↗

Wireless Temperature-Monitoring System

A relatively inexpensive instrumentation system that includes units that are connected to thermocouples and that are parts of a radio-communication network has been developed to enable monitoring of temperatures at multiple locations. Because there is no need to string wires or cables for communication, the system is well suited for monitoring temperatures at remote locations and for applications in which frequent changes of monitored or monitoring locations are needed. The system can also be adapted to monitoring of slowly varying physical quantities, other than temperature, that can be transduced by solid-state electronic sensors. The system comprises any number of transmitting units and a single receiving unit (see figure). Each transmitting unit includes connections for as many as four external thermocouples, a signal-conditioning module, a control module, and a radio-communication module. The signal- conditioning module acts as an interface between the thermocouples and the rest of the transmitting unit and includes a built-in solid ambient-temperature sensor that is in addition to the external thermocouples. The control module is a "system-on-chip" embedded processor that includes analog-to-digital converters, serial and parallel data ports, and an interface for local connection to an analog meter that is used during installation to verify correct operation. The radio-communication module contains a commercial spread-spectrum transceiver that operates in the 900-MHz industrial, scientific, and medical (ISM) frequency band. This transceiver transmits data to the receiving unit at a rate of 19,200 baud. The receiving unit includes a transceiver like that of a transmitting unit, plus a control module that contains a system-on-chip processor that includes serial data port for output to a computer that runs monitoring and/or control software, a parallel data port for output to a printer, and a seven-segment light-emitting-diode display.

Solano, Wanda↗

Wideband Reconfigurable Harmonically Tuned GaN SSPA for Cognitive Radios

The paper presents the architecture of a wideband reconfigurable harmonically-tuned Gallium Nitrate (GaN) Solid State Power Amplifier (SSPA) for cognitive radios. When interfaced with the physical layer of a cognitive communication system, this amplifier topology offers broadband high efficiency through the use of multiple tuned input/output matching networks. This feature enables the cognitive radio to reconfigure the operating frequency without sacrificing efficiency. This paper additionally presents as a proof-of-concept the design, fabrication, and test results for a GaN inverse class-F type amplifier operating at X-band (8.4 GHz) that achieves a maximum output power of 5.14-W, Power Added Efficiency (PAE) of 38.6, and Drain Efficiency (DE) of 48.9 under continuous wave (CW) operation.

Cognitive↗

Multiband Reconfigurable Harmonically Tuned Gallium Nitride (GaN) Solid-State Power Amplifier (SSPA) for Cognitive Radios

The paper presents the architecture of a wideband reconfigurable harmonically-tuned Gallium Nitride (GaN) Solid State Power Amplifier (SSPA) for cognitive radios. When interfaced with the physical layer of a cognitive communication system, this amplifier topology offers broadband high efficiency through the use of multiple tuned input/output matching networks. This feature enables the cognitive radio to reconfigure the operating frequency without sacrificing efficiency. This paper additionally presents as a proof-of-concept the design, fabrication, and test results for a GaN inverse Class-F type amplifier operating at X-band (8.4 GHz) that achieves a maximum output power of 5.14-W, Power Added Efficiency (PAE) of 38.6 percent, and Drain Efficiency (DE) of 48.9 percent under continuous wave (CW) operation.

Cognitive↗

Mars Global Climate Modeling.

Scientists use Global Climate Models (GCMs) to better under the current and past climate states of terrestrial (solid surface) bodies in our solar system and beyond, and the physical processes that control them. GCMs are complex, multi-dimensional computer codes that can generally be divided into two parts: the geophysical fluid dynamics (GFD) framework, which represents accelerations and spatially resolved processes, and the physics routines, which provide the forcing functions for the circulation. Producing a GCM that is appropriate for a particular body—Mars, for example—requires implementing the appropriate physics routines (e.g., radiative transfer, planetary boundary layer physics, dust lifting physics to generate dust storms, etc.) for that body. In this talk, I will give an overview of the components of the NASA Ames Mars GCM and discuss some of the scientific questions we address with this state-of-the-art numerical model.

Melinda A. Kahre↗

Direct Measurements of Infrared Intensities of HCN and H2O + HCN Ices for Laboratory and Observational Astrochemistry

Hydrogen cyanide (HCN) is found in a wide variety of extraterrestrial environments within and beyond the solar system, and for that reason laboratory spectroscopists have studied this compound in many spectral regions, including the infrared (IR). However, one aspect that remains to be investigated is the intrinsic IR spectral intensities of solid HCN as opposed to relative band strengths, intrinsic intensities being needed to measure HCN abundances. Here we report measurements of IR absorption coefficients and band strengths, along with supporting refractive indices and densities, of both amorphous and crystalline HCN at two temperatures, one for interstellar work and one more relevant to the outer solar system. Spectra are presented at both temperatures, along with optical constants that can be used in numerical models. Despite widespread and longstanding interest in and investigations of solid HCN, this is the first time that the properties we are reporting have been measured in a single laboratory, avoiding the need for estimates or to combine results from various authors. We find that our measured band strength of ~1 × 1017 cm molecule1 for the CN vibration of HCN, in both amorphous HCN and in an H2O-rich ice, is substantially higher than an earlier estimate. Unless errors of 100% can be tolerated then our new value requires a rescaling of earlier work. Our results shed light on why HCN and other nitriles have been so difficult to identify in the solid state, in contrast to their many detections in the gas phase.

astrochemistry – methods: laboratory – solid state↗

Direct Measurements of Infrared Intensities of HCN and H2O + HCN Ices for Laboratory and Observational Astrochemistry

Hydrogen cyanide (HCN) is found in a wide variety of extraterrestrial environments within and beyond the solar system, and for that reason laboratory spectroscopists have studied this compound in many spectral regions, including the infrared (IR). However, one aspect that remains to be investigated is the intrinsic IR spectral intensities of solid HCN as opposed to relative band strengths, intrinsic intensities being needed to measure HCN abundances. Here we report measurements of IR absorption coefficients and band strengths, along with supporting refractive indices and densities, of both amorphous and crystalline HCN at two temperatures, one for interstellar work and one more relevant to the outer solar system. Spectra are presented at both temperatures, along with optical constants that can be used in numerical models. Despite widespread and longstanding interest in and investigations of solid HCN, this is the first time that the properties we are reporting have been measured in a single laboratory, avoiding the need for estimates or to combine results from various authors. We find that our measured band strength of ~1 × 1017 cm molecule1 for the CN vibration of HCN, in both amorphous HCN and in an H2O-rich ice, is substantially higher than an earlier estimate. Unless errors of 100% can be tolerated then our new value requires a rescaling of earlier work. Our results shed light on why HCN and other nitriles have been so difficult to identify in the solid state, in contrast to their many detections in the gas phase.

astrochemistry – methods: laboratory – solid state↗

Materials research at Stanford University

Information briefly describing the total research activity related to the science of materials is reported. Emphasis is placed on physical and mechanical properties of composite materials, energy transportation, superconductors, microwave electronics, and solid state electrochemistry.

Source record↗

Spaceborne Photonics Institute

This report describes in chronological detail the development of the Spaceborne Photonics Institute as a sustained research effort at Hampton University in the area of optical physics. This provided the research expertise to initiate a PhD program in Physics. Research was carried out in the areas of: (1) modelling of spaceborne solid state laser systems; (2) amplified spontaneous emission in solar pumped iodine lasers; (3) closely simulated AM0 CW solar pumped iodine laser and repeatedly short pulsed iodine laser oscillator; (4) a materials spectroscopy and growth program; and (5) laser induced fluorescence and atomic and molecular spectroscopy.

Venable, D. D.↗

Influence of Test Procedures on the Thermomechanical Properties of a 55NiTi Shape Memory Alloy

Over the past few decades, binary NiTi shape memory alloys have received attention due to their unique mechanical characteristics, leading to their potential use in low-temperature, solid-state actuator applications. However, prior to using these materials for such applications, the physical response of these systems to mechanical and thermal stimuli must be thoroughly understood and modeled to aid designers in developing SMA-enabled systems. Even though shape memory alloys have been around for almost five decades, very little effort has been made to standardize testing procedures. Although some standards for measuring the transformation temperatures of SMA s are available, no real standards exist for determining the various mechanical and thermomechanical properties that govern the usefulness of these unique materials. Consequently, this study involved testing a 55NiTi alloy using a variety of different test methodologies. All samples tested were taken from the same heat and batch to remove the influence of sample pedigree on the observed results. When the material was tested under constant-stress, thermal-cycle conditions, variations in the characteristic material responses were observed, depending on test methodology. The transformation strain and irreversible strain were impacted more than the transformation temperatures, which only showed an affect with regard to applied external stress. In some cases, test methodology altered the transformation strain by 0.005-0.01mm/mm, which translates into a difference in work output capability of approximately 2 J/cu cm (290 in!lbf/cu in). These results indicate the need for the development of testing standards so that meaningful data can be generated and successfully incorporated into viable models and hardware. The use of consistent testing procedures is also important when comparing results from one research organization to another. To this end, differences in the observed responses will be presented, contrasted and rationalized, in hopes of eventually developing standardized testing procedures for shape memory alloys.

Padula, Santo A., II↗

Design Considerations for Practical Li-S Batteries for Electric Aviation

The development of high-energy, high-safety, and high-power batteries beyond electric automotive standards is critical for future electric aviation applications. Non-volatile solid-state electrolytes (SSE) offer many promising advantages over traditional flammable liquid electrolytes. Solid-state electrolytes may be an enabling technology for certain battery chemistries by preventing detrimental interactions with liquid electrolytes, for example prevention of the dissolution of intermediates in lithium-sulfur common in traditional liquid organic solvents. However, significant manufacturing challenges must be overcome before the adoption of such technology. This research was conducted to identify processing techniques for producing solid-state battery components with practical dimensions and weights for enabling high specific energy cells. Traditional research has identified a range of very high theoretical ionic conductivities but are impractical due to their instability or inability to be manufactured. Electrolytes explored in this study were produced as sulfide-polymer composites with densified thicknesses below 40 micron using a tape-casting technique and thermoplastic elastomer binder. The combination of high chemical compatibility and flexibility produced robust films that had moderate impact on the ionic conductivity but was capable of dramatically reducing the parasitic mass. Despite minimal conductivity losses, films were produced 10-15 times thinner than comparable bulk powder electrolytes thus leading to overall lower film resistance. Conductivity is maintained above 0.2mS/cm for composite electrolytes. Through the analysis of materials based on their physical properties, such as density, practical cells can be designed. Based on this, low density sulfide-solid-state electrolytes are a promising candidate for achieving the energy and safety metrics for electric aviation, however, further optimization of cathode microstructure and composite processing will be required to achieve the high power metrics and will be the focus of further studies. Additionally, fabrication challenges arise when utilizing metallic lithium foil, due to its soft nature, as overflow and mechanical short circuit can occur on assembly which remains a challenge to overcome before metallic lithium anodes can be fully realized.

batteries↗

Nuclear Science Symposium, 4th, and Nuclear Power Systems Symposium, 9th, San Francisco, Calif., October 19-21, 1977, Proceedings

Consideration is given to the following types of high energy physics instrumentation: drift chambers, multiwire proportional chambers, calorimeters, optical detectors, ionization and scintillation detectors, solid state detectors, and electronic and digital subsystems. Attention is also paid to reactor instrumentation, nuclear medicine instrumentation, data acquisition systems for nuclear instrumentation, microprocessor applications in nuclear science, environmental instrumentation, control and instrumentation of nuclear power generating stations, and radiation monitoring. Papers are also presented on instrumentation for the High Energy Astronomy Observatory.

Source record↗

Semiconductor Laser Low Frequency Noise Characterization

This work summarizes the efforts in identifying the fundamental noise limit in semiconductor optical sources (lasers) to determine the source of 1/F noise and it's associated behavior. In addition, the study also addresses the effects of this 1/F noise on RF phased arrays. The study showed that the 1/F noise in semiconductor lasers has an ultimate physical limit based upon similar factors to fundamental noise generated in other semiconductor and solid state devices. The study also showed that both additive and multiplicative noise can be a significant detriment to the performance of RF phased arrays especially in regard to very low sidelobe performance and ultimate beam steering accuracy. The final result is that a noise power related term must be included in a complete analysis of the noise spectrum of any semiconductor device including semiconductor lasers.

SEMICONDUCTOR LASERS↗

The Gamma-ray Large Area Space Telescope (GLAST) Mission Concept Study

The Gamma-ray Large Area Space Telescope (GLAST), a next generation high-energy gamma-ray mission designed to observe cosmic sources of gamma-rays over the approximate energy range from 10 MeV to 300 GeV, was studied for possible flight in the next decade. The GLAST baseline mission studied will achieve a major advance in sensitivity beyond EGRET by the use of modern particle physics tracking technology. The baseline instrument design that has been extensively studied uses solid-state silicon strip detectors for particle tracking and efficient on-board data processing and event triggering to achieve more than an order of magnitude improvement in sensitivity compared to EGRET. Development of technology requirements and a technology development roadmap for the GLAST mission is presented.

Michelson, Peter F.↗