Search NASA⌕ Search

SEARCH · Search NASA

Results for “spallation source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Coherent Scattering Investigations at the Spallation Neutron Source: a Snowmass White Paper

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory, Tennessee, provides an intense flux of neutrinos in the few tens-of-MeV range, with a sharply-pulsed timing structure that is beneficial for background rejection. In this white paper, we describe how the SNS source can be used for a measurement of coherent elastic neutrino-nucleus scattering (CENNS), and the physics reach of different phases of such an experimental program (CSI: Coherent Scattering Investigations at the SNS).

Akimov, D.↗

RISE/FALL TIME ENHANCEMENT OF THE SPALLATION NEUTRON SOURCE LINAC LEBT CHOPPER SYSTEM

The Spallation Neutron Source (SNS) Linac Low Energy Beam Transport (LEBT) chopper system provides fast chopping of the H- ion beam in the LEBT structure. Four identical pulsed power supplies (pulsers) create a series of 2.5 kV pulses to the four deflection electrodes floating on the focusing voltage of -50 kV. Each pulser is connected to the electrode through the network which consists of high voltage (HV) cables, a blocking capacitor, HV feed-through connectors, current-limiting resistors and transient voltage suppressors. Effective beam chopping requires minimal rise/fall time of the rectangular HV pulses on the load. In the present configuration these values are approximately 100 ns. Methods of reducing rise/fall time on the LEBT electrodes are discussed. Results of simulation and comparative measurements of the original and upgraded system on the test stand are presented. Furthermore, the effect of these changes on reliability degradation caused by arcing in the LEBT structure is discussed.

LEBT chopper↗

DEVELOPMENT OF THE CRYOGENIC HYDROGEN SYSTEM FOR A SPALLATION NEUTRTON SOURCE IN J-PARC

An intense spallation neutron source (JSNS) driven by a proton beam of 1-MW has been constructed as one of the main experimental facilities in J-PARC. Supercritical hydrogen at around 20 K and 1.5 MPa was selected as a moderator material in JSNS. Three kinds of hydrogen moderators (coupled, decoupled, and poisoned) were installed to provide pulsed neutron beam of higher neutronic performance. The total nuclear heating in the moderators was estimated to be 3.75 kW for a proton beam power of 1 MW. The cryogenic hydrogen system, where the hydrogen circulation system is cooled by a helium refrigerator system with the refrigerator capacity of 6.45 kW at 15.6 K, provides the supercritical hydrogen for the moderators and absorbs nuclear heating in the moderators. The off-beam commissioning has confirmed that the cryogenic hydrogen system can be cooled down to 18 K within 19 hours. The supercritical hydrogen with a mass flow rate of 190 g/s can be circulated in the rated condition. It was verified that the cryogenic hydrogen system satisfied the performance requirements. The first cold neutron beam cooled by the cryogenic hydrogen system was successfully generated in May 2008.

42 ENGINEERING↗

Characterization of an explosively bonded aluminum proton beam window for the Spallation Neutron Source

An effort is underway at the Spallation Neutron Source (SNS) to change the design of the 1st Generation high-nickel alloy proton beam window (PBW) to one that utilizes aluminum for the window material. One of the key challenges to implementation of an aluminum PBW at the SNS was selection of an appropriate joining method to bond an aluminum window to the stainless steel bulk shielding of the PBW assembly. An explosively formed bond was selected as the most promising joining method for the aluminum PBW design. A testing campaign was conducted to evaluate the strength and efficacy of explosively formed bonds that were produced using two different interlayer materials: niobium and titanium. The characterization methods reported here include tensile testing, thermal-shock leak testing, optical microscopy, and advanced scanning electron microscopy. All tensile specimens examined failed in the aluminum interlayer and measured tensile strengths were all slightly greater than the native properties of the aluminum interlayer, while elongation values were all slightly lower. A leak developed in the test vessel with a niobium interlayer joint after repeated thermal-shock cycles, and was attributed to an extensive crack network that formed in a layer of niobium-rich intermetallics located on the bond interfaces of the niobium interlayer; the test vessel with a titanium interlayer did not develop a leak under the conditions tested. Due to the experience gained from these characterizations, the explosively formed bond with a titanium interlayer was selected for the aluminum PBW design at the SNS.

316L Stainless Steel↗

SPALLATION NEUTRON SOURCE HIGH-POWER PROTECTION MODULE TEST STAND

The Spallation Neutron Source (SNS) High-Power Protection Module (HPM) provides interlocks and fast shutdown for the radio frequency (RF) system to protect the accelerating structures and high power RF (HPRF) Distribution System. The HPM has required some functional upgrades since the start of beam operations and an upgrade to the HPM test stand was required to support these added features. The HPM test stand currently verifies functionality, RF channel calibration, and measurement of the speed of shutdown to ensure the specifications are met. The upgraded test stand was implemented in a Field Programmable Gate Array (FPGA) to allow for future growth and flexibility. Work is currently progressing on automation of the test stand to better perform the required module calibration schedule.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of irradiated AISI 316L stainless steel disks removed from the Spallation Neutron Source

Irradiated AISI 316L stainless steel disks were removed from the Spallation Neutron Source (SNS) for post-irradiation examination (PIE) to assess mechanical property changes due to radiation damage and erosion of the target vessel. Topics reviewed include high-resolution photography of the disk specimens, cleaning to remove mercury (Hg) residue and surface oxides, profile mapping of cavitation pits using high frequency ultrasonic testing (UT), high-resolution surface replication, and machining of test specimens using wire electrical discharge machining (EDM), tensile testing, Rockwell Superficial hardness testing, Vickers microhardness testing, scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS). The effectiveness of the cleaning procedure was evident in the pre- and post-cleaning photography and permitted accurate placement of the test specimens on the disks. Due to the limited amount of material available and the unique geometry of the disks, machine fixturing and test specimen design were critical aspects of this work. Multiple designs were considered and refined during mock-up test runs on unirradiated disks. The techniques used to successfully machine and test the various specimens will be presented along with a summary of important findings from the laboratory examinations.

cavitation-induced erosion↗

Stabilized operation of the improvement of the Spallation Neutron Source (SNS) radio-frequency quadrupole (RFQ)

The Spallation Neutron Source (SNS) radio-frequency quadrupole (RFQ) had resonance control instabilities at duty factors higher than approximately four percent. Systematic investigations have been carried out to understand the cause of the instability and to ensure the operational stability of the RFQ. The most critical source of the instability is revealed to be an interaction between hydrogen released by beam bombardments and the RFQ RF field resulting in a discharge, which consumes additional RF power and could cause the RFQ to operate in an unstable region. This paper reports improvement of the SNS RFQ operational stability based on the findings during the SNS operation.

08 HYDROGEN↗

Fatigue analysis of the Spallation Neutron Source 2 MW target design

Upgrades to the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory are under way with two major projects. The first project is the Proton Power Upgrade (PPU), which will double the power capacity of the SNS accelerator system to enable the operation of a future second neutron source target station—the second project. PPU also will increase power to the SNS first target station – which currently operates at 1.4 MW with 1.0 GeV protons – to 2 MW with 1.3 GeV protons. Final design of the PPU 2 MW target module is finished, including all necessary design and analysis calculations. The fatigue evaluation described herein is an assessment of the fitness of the PPU 2 MW target mercury vessel to resist failure from cyclic loading from the pulsed 60 Hz proton beam and thermal changes from disrupted operation. In addition to the reliability predictions, the method, detail, and depth of this fatigue evaluation are superior to those of past target design assessments. Furthermore, the thermal fatigue life is predicted to exceed 3125 thermal cycles per 1250 h of operation for all load cases. The design also meets the (relative) fatigue design goal for combined thermal and pulse loading of greater than 0.5 times the minimum fatigue life calculated for a jet-flow target design operating at 1.4 MW—the most robust design to date in terms of resistance to fatigue failure. From the onset of the PPU, it has been known that pulse loading requires effective application of helium gas injection into the target mercury to reduce beam pressure loading. For the PPU 2 MW target, none of the pulse load cases requires a maximum strain reduction from gas injection of more than 50% (for base material) to meet the fatigue design goal. This level of reduction is achievable from gas injection, according to historical strain measurements from 1.4 MW target operation. Overall, the PPU 2 MW target design is predicted to have superior resistance to fatigue failure compared with past target designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Compact Gas Liquid Separator for the Spallation Neutron Source Mercury Process Loop

Upgrades at the spallation neutron source (SNS) accelerator at Oak Ridge National Laboratory are underway to double its proton beam power from 1.4 to 2.8 MW. About 2 MW will go to the current first station while the rest will go to the future Second Target Station. The increase of beam power to the first target station is especially challenging for its mercury target. When the short proton beam hits the target, strong pressure waves are generated, causing cavitation erosion and challenging stresses for the target's weld regions. SNS has successfully operated reliably at 1.4 MW by mitigating the pressure wave with the injection of small Helium bubbles into the mercury. To operate reliably at 2 MW, more gas will be injected into mercury to mitigate the pressure wave further. However, the mercury process loop was not originally designed for gas injection, and the accumulation of gas in the pipes is a concern. Due to space constraints, a custom gas liquid separator (GLS) was designed to fit a 90-deg horizontal elbow space in the SNS mercury loop. Simulations and experiments were performed, and a successful design was developed that has the desired efficiency while keeping the pressure losses acceptable.

42 ENGINEERING↗

The Spallation Neutron Source Beam Commissioning and Initial Operations

The Spallation Neutron Source (SNS) accelerator delivers a one mega-Watt beam to a mercury target to produce neutrons used for neutron scattering materials research. It delivers ~ 1 GeV protons in short (< 1 us) pulses at 60 Hz. At an average power of ~ one mega-Watt, it is the highest-powered pulsed proton accelerator. The accelerator includes the first use of superconducting RF acceleration for a pulsed protons at this energy. The storage ring used to create the short time structure has record peak particle per pulse intensity. Beam commissioning took place in a staged manner during the construction phase of SNS. After the construction, neutron production operations began within a few months, and one mega-Watt operation was achieved within three years. The methods used to commission the beam and the experiences during initial operation are discussed.

43 PARTICLE ACCELERATORS↗

INITIAL COMMISSIONING EXPERIENCE WITH THE SPALLATION NEUTRON SOURCE VERTICAL TEST AREA RF SYSTEM

The Spallation Neutron Source (SNS) has developed a vertical test area (VTA) for the testing and qualification of superconducting radio frequency cavities. The associated RF System successfully supported the initial commissioning of the VTA system and has been utilized for cavity testing at both 4 and 2 K. As operational experience was gained, improvements to the RF system were implemented to better utilize the dynamic range of the system, and software updates and additions were made to meet operational needs. The system continues to evolve as we gain better understanding of the testing needs.

Crofford, Mark↗

Cavitation-induced erosion in liquid metal spallation targets – A comparison between a predictive method and measured erosion damage to stainless steel target modules at the Spallation Neutron Source

Neutrons are produced for neutron scattering instruments at the Spallation Neutron Source by bombarding liquid mercury with a pulsed high-energy proton beam. The liquid mercury target material flows through a replaceable stainless-steel target vessel and cavitates during operation due to the extremely high heating rate caused by each proton pulse. Cavitation-induced erosion damage to the mercury-facing surfaces of target vessels is a key concern for target lifetime and has been the subject of considerable research. While numerous experiments have studied and modeled the progression of cavitation erosion damage to liquid metal target containers, direct quantitative measurements of actual erosion of a spallation target vessel were previously not available. Recently, the erosion damage to multiple target vessels operated at the Spallation Neutron Source was measured using a high-resolution laser scanning system, which provided an opportunity to study the efficacy of a cavitation damage progression model. In this paper, a cavitation progression modeling procedure developed using empirical observations is compared to measurements of samples from target vessels after operation. We discuss the strengths and limitations of the technique and propose methods for improving future modeling and predictive accuracy.

36 MATERIALS SCIENCE↗

Conceptual Design of the Moderator Test Station at the Spallation Neutron Source

We describe the Moderator Test Station (MTS), under construction at the Spallation Neutron Source. We will leverage the Beam Test Facility (BTF) at the Spallation Neutron Source to provide a moderator neutronics test stand with which we will verify the anticipated performance gains expected and required from the innovative moderator concepts central to the SNS Second Target Station (STS) and the future of the First Target Station (FTS). These concepts include large-volume para-hydrogen moderators and high-brightness tube moderators. The MTS will add to the existing BTF a proton beam chopper similar to that already used in the SNS at the RFQ exit (the so-called MEBT chopper), various proton beam transport components, a neutron-producing target, a cryogenic moderator test stand, a reflector-shielding assembly, and a performance assessment neutron beamline. The MTS will provide the ability to test a wide variety of moderators in a prototypic configuration, simultaneously measuring the neutronic performance of the moderator concept central to the anticipated STS gains and developing the instrumentation necessary to provide that performance in a production environment. The presentation will describe the MTS, its progress, and the way we optimize the prototypic nature of the moderators we will test.

Iverson, Erik B↗

Operational experiences of the spallation neutron source superconducting linac and power ramp-up

The spallation neutron source (SNS) is a second generation pulsed neutron source and designed to provide a 1-GeV, 1.44-MW proton beam to a mercury target for neutron production. Since the commissioning of the accelerator complex in 2006, the SNS has started its operation for neutron production and beam power ramp-up has been in progress toward the design goal. All subsystems of the SNS were designed and developed for substantial improvements compared to existing accelerators because the design beam power is almost an order of magnitude higher compared to existing neutron facilities and the achievable neutron scattering performance will exceed present sources by more than a factor of 20 to 100. In this paper, the operational experiences with the SNS Superconducting Linac (SCL), Power Ramp-up Plan to reach the design goal and the Power Upgrade Plan (PUP) will be presented including machine, subsystem and beam related issues.

43 PARTICLE ACCELERATORS↗

Spallation neutron source GNEIS

A brief description of the spallation pulsed neutron source and neutron TOF spectrometer GNEIS based on the 1 GeV proton synchrocyclotron of PNPI in Gatchina is presented. The main parameters of the GNEIS are given in comparison with the analogous world-class facilities. The experimental capabilities of the GNEIS are demonstrated by the examples of some nuclear physics and applied research experiments carried out during four decades of its operation.

43 PARTICLE ACCELERATORS↗

A time-of-flight backscattering spectrometer at the Spallation Neutron Source, BASIS

We describe the design and current performance of the backscattering silicon spectrometer (BASIS), a time-of-flight backscattering spectrometer built at the spallation neutron source (SNS) of the Oak Ridge National Laboratory (ORNL). BASIS is the first silicon-based backscattering spectrometer installed at a spallation neutron source. In addition to high intensity, it offers a high-energy resolution of about 3.5 {mu}eV and a large and variable energy transfer range. These ensure an excellent overlap with the dynamic ranges accessible at other inelastic spectrometers at the SNS.

43 PARTICLE ACCELERATORS↗

Awareness, Preference, Utilization, and Messaging Research for the Spallation Neutron Source and High Flux Isotope Reactor

Oak Ridge National Laboratory (ORNL) offers the scientific community unique access to two types of world-class neutron sources at a single site - the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR). The 85-MW HFIR provides one of the highest steady-state neutron fluxes of any research reactor in the world, and the SNS is one of the world's most intense pulsed neutron beams. Management of these two resources is the responsibility of the Neutron Sciences Directorate (NScD). NScD commissioned this survey research to develop baseline information regarding awareness of and perceptions about neutron science. Specific areas of investigative interest include the following: (1) awareness levels among those in the scientific community about the two neutron sources that ORNL offers; (2) the level of understanding members of various scientific communities have regarding benefits that neutron scattering techniques offer; and (3) any perceptions that negatively impact utilization of the facilities. NScD leadership identified users of two light sources in North America - the Advanced Photon Source (APS) at Argonne National Laboratory and the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory - as key publics. Given the type of research in which these scientists engage, they would quite likely benefit from including the neutron techniques available at SNS and HFIR among their scientific investigation tools. The objective of the survey of users of APS, NSLS, SNS, and HFIR was to explore awareness of and perceptions regarding SNS and HFIR among those in selected scientific communities. Perceptions of SNS and FHIR will provide a foundation for strategic communication plan development and for developing key educational messages. The survey was conducted in two phases. The first phase included qualitative methods of (1) key stakeholder meetings; (2) online interviews with user administrators of APS and NSLS; and (3) one-on-one interviews and traditional and online focus groups with scientists. The latter include SNS, HFIR, and APS users as well as scientists at ORNL, some of whom had not yet used HFIR and/or SNS. These approaches informed development of the second phase, a quantitative online survey. The survey consisted of 16 questions and 7 demographic categorizations, 9 open-ended queries, and 153 pre-coded variables and took an average time of 18 minutes to complete. The survey was sent to 589 SNS/HFIR users, 1,819 NSLS users, and 2,587 APS users. A total of 899 individuals provided responses for this study: 240 from NSLS; 136 from SNS/HFIR; and 523 from APS. The overall response rate was 18%.

43 PARTICLE ACCELERATORS↗

A realistic guide misalignment model for the Second Target Station instruments at the Spallation Neutron Source

The Second Target Station (STS) at the Spallation Neutron Source, including a suite of initial instrument concepts, are being designed in Oak Ridge. The moderator size at STS is significantly smaller than that of the First Target Station, making the guide misalignment a more prominent concern. Here a realistic misalignment model based on Monte Carlo neutron ray tracing simulation was developed to evaluate the impacts of both the random misalignment and floor settlement on the performance of a toy model of 150 m straight guide system, and MENUS, an STS instrument concept with a typical guide design of two opposing Montel mirrors. The study shows that longer instruments, and instruments with complex curved mirrors/guides are sensitive to significant performance penalties due to misalignments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗