Installation and commissioning of the ion source systems for the new spallation neutron source 2.5 MeV injector

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world’s most intense pulsed neutron beams to a wide array of instruments, which are used to conduct investigations in many fields of engineering, physics, chemistry, material science, and biology. Neutrons are produced by spallation of liquid Hg by the bombardment of short (∼1 µs), intense (∼35 A) pulses of protons delivered at 60 Hz by an accumulator ring which is fed by a high-intensity, 1 GeV, H− LINAC (linear accelerator). This facility has operated nearly continuously since 2006 but has recently undergone a 4-month maintenance period, which featured a complete replacement of the 2.5 MeV injector feeding the LINAC. The new injector was developed at ORNL in an off-line beam test facility and consists of an ion source, low energy beam transport, and a Radio Frequency Quadrupole (RFQ). This report first describes the installed configuration of the new injector detailing the ion source system. The first beam current, RFQ transmission, emittance, and energy measurements from the injector installed on the SNS are reported. These data not only show a significant performance improvement for our existing facility but will also make accessible the higher beam current requirements for future SNS upgrade projects: the proton power upgrade and second target station.

Welton, R. F.↗

Broadband Wide-Angle VElocity Selector (BWAVES) neutron spectrometer designed for the SNS Second Target Station

A recently proposed wide-angle velocity selector (WAVES) device for choosing the velocity of detected neutrons after they have been scattered by the sample paves the way for inverted geometry neutron spectrometers with continuously adjustable final neutron wavelength. BWAVES broadband inverted geometry spectrometer proposed for the Second Target Station at the Spallation Neutron Source at Oak Ridge National Laboratory is designed using WAVES to simultaneously probe dynamic processes spanning 4.5 decades in time (energy transfer). This makes BWAVES a uniquely flexible instrument which can be viewed as either a quasielasitc neutron scattering (QENS) spectrometer with a practically unlimited (overlapping with the vibrational excitations) range of energy transfers, or a broadband inelastic vibrational neutron spectrometer with QENS capabilities, including a range of accessible momentum transfer (Q) and a sufficiently high energy resolution at the elastic line. The new capabilities offered by BWAVES will expand the application of neutron scattering in ways not possible with existing neutron spectrometers.

36 MATERIALS SCIENCE↗

Cinematic reflectometry using QIKR, the quite intense kinetics reflectometer

The Quite Intense Kinetics Reflectometer (QIKR) will be a general-purpose, horizontal-sample-surface neutron reflectometer. Reflectometers measure the proportion of an incident probe beam reflected from a surface as a function of wavevector (momentum) transfer to infer the distribution and composition of matter near an interface. The unique scattering properties of neutrons make this technique especially useful in the study of soft matter, biomaterials, and materials used in energy storage. Exploiting the increased brilliance of the Spallation Neutron Source Second Target Station, QIKR will collect specular and off-specular reflectivity data faster than the best existing such machines. It will often be possible to collect complete specular reflectivity curves using a single instrument setting, enabling “cinematic” operation, wherein the user turns on the instrument and “films” the sample. Samples in time-dependent environments (e.g., temperature, electrochemical, or undergoing chemical alteration) will be observed in real time, in favorable cases with frame rates as fast as 1 Hz. Cinematic data acquisition promises to make time-dependent measurements routine, with time resolution specified during post-experiment data analysis. This capability will be deployed to observe such processes as in situ polymer diffusion, battery electrode charge–discharge cycles, hysteresis loops, and membrane protein insertion into lipid layers.

47 OTHER INSTRUMENTATION↗

New Opportunities for Neutrons in Environmental and Biological Sciences

The use of neutron methods in environmental and biological sciences is rapidly emerging and accelerating with the development of new instruments at neutron user facilities. This article, based on a workshop held at Oak Ridge National Laboratory (ORNL), offers insights into the application of neutron techniques in environmental and biological sciences. Here we highlight recent advances and identify key challenges and potential future research areas. These include soil and rhizosphere processes, root water dynamics, plant-microbe interactions, structure and dynamics of biological systems, applications in synthetic biology and enzyme engineering, next-generation bioproducts, biomaterials and bioenergy, nanoscale structure, and fluid dynamics of porous materials in geochemistry. We provide an outlook on emerging opportunities with an emphasis on new capabilities that will be enabled at the Spallation Neutron Source Second Target Station currently under design at ORNL. The mission of scientific neutron user facilities worldwide is to enable science using state-of-the-art neutron capabilities. We aim to encourage researchers in the environmental and biological research community to explore the unique capability afforded by neutrons at these facilities.

54 ENVIRONMENTAL SCIENCES↗

CHESS: The future direct geometry spectrometer at the second target station

CHESS, chopper spectrometer examining small samples, is a planned direct geometry neutron chopper spectrometer designed to detect and analyze weak signals intrinsic to small cross sections (e.g., small mass, small magnetic moments, or neutron absorbing materials) in powders, liquids, and crystals. CHESS is optimized to enable transformative investigations of quantum materials, spin liquids, thermoelectrics, battery materials, and liquids. The broad dynamic range of the instrument is also well suited to study relaxation processes and excitations in soft and biological matter. The 15 Hz repetition rate of the Second Target Station at the Spallation Neutron Source enables the use of multiple incident energies within a single source pulse, greatly expanding the information gained in a single measurement. Furthermore, the high flux grants an enhanced capability for polarization analysis. This enables the separation of nuclear from magnetic scattering or coherent from incoherent scattering in hydrogenous materials over a large range of energy and momentum transfer. This paper presents optimizations and technical solutions to address the key requirements envisioned in the science case and the anticipated uses of this instrument.

47 OTHER INSTRUMENTATION↗

A flexible neutron spectrometer concept with a new ultra-high field steady-state vertical-bore magnet

The proposed facility explores materials under ultra-high magnetic fields. By combining the power of high fields to tune materials and of neutron scattering to probe the resulting changes down to the atomic scale, this facility will enable transformative progress in the study of quantum materials and is named for the “TITAN” subset of Greek gods to reflect this transformation. TITAN will offer DC magnetic fields up to at least 20 T. Exploiting the record brightness and bandwidth of the Second Target Station at the Spallation Neutron Source, TITAN will probe atomic-scale responses through high efficiency neutron spectroscopy up to 80 meV energy transfer, high resolution diffraction, and small angle neutron scattering. Focusing neutron optics will maximize flux on accurately positioned samples, while radial collimation and optimized shielding and detection strategies will minimize backgrounds.

47 OTHER INSTRUMENTATION↗

Conceptual Polarization Setup at CENTAUR, the SANS/WANS Instrument at the Second Target Station of SNS

CENTAUR is a multifunctional general purpose small-angle and wide-angle neutron scattering instrument with diffraction and spectroscopic capability in the future Second Target Station at the Spallation Neutron Source of the Oak Ridge National Laboratory. To fill a gap in neutron polarization capability, the instrument will be designed to provide polarization analysis. Here we present the conceptual polarization setup at CENTAUR, as well as the Spin Echo Modulated Small-Angle Neutron Scattering setup which will further expand the length scale covered by the instrument.

Qian, Shuo↗

On possibility of low-emittance high-energy muon source based on plasma wakefield acceleration

We report plasma wakefield acceleration (PWA) channels are characterized by very high accelerating gradients and very strong focusing fields. We propose to employ these properties for effective production of low emittance high energy muon beams, consider muon beam dynamics in the PWFA cell and analyze various options and potential of the PWA-based muon sources.

43 PARTICLE ACCELERATORS↗

A science-driven approach to optimize the design for a biological small-angle neutron scattering instrument

Biological small-angle neutron scattering (SANS) instruments facilitate critical analysis of the structure and dynamics of complex biological systems. However, with the growth of experimental demands and the advances in optical systems design, a new neutron optical concept is necessary to overcome the limitations of current instruments. This work presents an approach to include experimental objectives ( i.e. the science to be supported by a specific neutron scattering instrument) in the optimization of the neutron optical concept. The approach for a proposed SANS instrument at the Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory, USA, is presented here. Further, the instrument is simulated with the McStas software package. The optimization process is driven by an evolutionary algorithm using McStas output data, which are processed to calculate an objective function designed to quantify the expected performance of the simulated neutron optical configuration for the intended purpose. Each McStas simulation covers the complete instrument, from source to detector, including realistic sample scattering functions. This approach effectively navigates a high-dimensional parameter space that is otherwise intractable; it allows the design of next-generation SANS instruments to address specific scientific cases and has the potential to increase instrument performance compared with traditional design approaches.

47 OTHER INSTRUMENTATION↗

Optimization of the moderators in the STS preliminary design

This report details the results for an optimization of the dimensions of the moderators in the preliminary design of the Spallation Neutron Source Second Target Station (STS). This study uses the optimization algorithms of Dakota and an unstructured mesh model for the moderators in MCNP. More details on the unstructured mesh model and the automated mesh generation can be found in [3]. Parallel to this effort, the same moderator geometries have been optimized using a constructive solid geometry (CSG) MCNP model. More details on this model and its results can be found in [4]. Three optimal designs are selected for each moderator: one that is optimized for maximum peak brightness, one for maximum time-integrated brightness, and one for a combination of peak and time-integrated brightness. The backbone of the optimization work flow is provided by Dakota. For each set of design parameters requested by Dakota, a new solid geometry is automatically built in Creo and SpaceClaim, and subsequently exported to Attila4MC to generate an unstructured mesh geometry for MCNP. After the MCNP calculation is finished, the objective function (e.g., brightness metric) is returned to Dakota. After the new design has been evaluated, a result-file is written, and Dakota proposes the next set of design parameters to be evaluated. The loop continues until a specified convergence criterion has been met. The design parameters of the cylindrical (upper) moderator include the hydrogen radius, the premoderator thickness (top, bottom, radial), the beryllium radius and the horizontal position of the moderator. The crucial design choice is the hydrogen radius. A radius of 62 mm is shown to provide the maximum time-integrated brightness. The maximum peak brightness occurs with a radius of 40 mm. A combined (middle) design, which balances peak and time-integrated brightnesses, is obtained with a hydrogen radius of 50 mm. The premoderator thicknesses and the beryllium radius are slightly larger in the design optimized for time-integrated brightness than in the design optimized for peak brightness. The sensitivity to these two parameters is relatively small close to the optimal configurations. The hydrogen vessel and vacuum vessel wall thicknesses are dependent on the radius of the liquid hydrogen due to structural integrity requirements. The increased wall thicknesses for larger vessels significantly penalize the time-integrated brightness, with the maximum obtainable value reduced by more than 10% relative to earlier studies which used fixed vessel wall thicknesses. The impact of the variable wall thicknesses is much less for the peak brightness and combined brightness designs. The design parameters of the tube (lower) moderator selected for the optimization are the tube length, the annular premoderator thickness, the beryllium radius and the horizontal position of the moderator. The tube length is the crucial parameter and is chosen large (210 mm) and small (125 mm) in the designs optimized for time-integrated and peak brightness respectively. A combined optimal design has a tube length of 170 mm. The premoderator thickness and the beryllium radius are chosen larger in the design optimized for time-integrated brightness.

42 ENGINEERING↗

Analyses of Dose Rates for Second Inner Reflector Plug Replacement at Spallation Neutron Source

The Inner Reflector Plug (IRP) is a central component of the Spallation Neutron Source (SNS) target monolith, which houses the liquid mercury target and four liter-sized neutron moderator units. It is exposed to high-level radiation fields during routine operation and builds up significant activity. The IRP needs to be replaced due to moderator neutron poison and decoupler burn-out, which is used for shaping neutron pulses. The first IRP exchange took place in March 2018 and next one, which is IRP2, is planned to be replaced during the facility maintenance period in the end of December 2025, beginning of January 2026 calendar year. The replacement of IRP is a complex task due to its location in the area receiving high irradiation, being under significant amount of shielding, and size, which requires removal in segments. For planning the replacement workflow to help to reduce radiation exposure to workers dose rates for each stage of extraction/replacement operation are predicted.

42 ENGINEERING↗

59 Co(p,X) spallation reaction cross sections for 250 MeV to 2 GeV protons

Cobalt is an advantageous target for probing the physics of nuclear spallation, because it is a naturally mono-isotopic element ( 59 Co), and its per-nucleon binding energy (BE/A = 8.768 MeV) is near the maximum value for all nuclei. We measured nuclear spallation cross sections for the 59 Co(p,X) reaction at five kinetic energies ranging from 250 MeV to 2 GeV. Cross sections for the production of 58 Co, 57 Co, 57 Mn, 56 Co, 56 Mn, 56 Cr, 55 Fe, 53 Fe, 54 Mn, 52 Mn, 51 Cr, 49 Cr, 48 V, 47 Sc, 46 Sc, 44 Sc, and 44 Scm are reported. Where comparable data exist in the EXFOR reaction database, we find that our measured cross sections generally agree. In many cases, we provide data for reactions or energies not currently reported in EXFOR. Our cross sections also provide evidence for the presence of α-clusters within the 59 Co nucleus, a surprising result given the asymmetry in Z (27) and N (32) for this nucleus. Finally, we use our measurements to evaluate the accuracy of spallation cross section simulations from GEANT4-based radiation transport toolkit, performed with the INCLXX-, Bertini-, and Binary-ion-cascade (BIC) based physics lists. This benchmarking activity revealed that the simulations overestimated the cross sections by a factor of ∼2–4 on average, and that the INCL-XX physics list provides the most reliable results. This evaluation informs the selection of the GEANT4 physics lists used for the analysis of data from NASA’s Psyche mission, which will measure γ rays and neutrons resulting from spallation reactions occurring on the surface of an asteroid whose surface is thought to be rich in iron-nickel metal.

43 PARTICLE ACCELERATORS↗

CINDER90 and CINDER2008 Comparison for Second Target Station Analysis

A preliminary target activation analysis for the Second Target Station (STS) at the Spallation Neutron Source (SNS) located at Oak Ridge National Laboratory (ORNL) was preformed using Monte Carlo N-Particle X (MCNPX), CINDER90, and the corresponding multi-group cross section libraries distributed with CINDER90. This preliminary analysis has been used to guide some design decisions of the STS target design. Using the MCNPX output files from this preliminary analysis, a comparison of the activation analysis using CINDER90 and CINDER2008 was performed. While the CINDER90 code has been validated for use in spallation source activation and transmutation calculations, and compares well with measurements, the transition to the modernized version of the code (CINDER2008) and the updated cross section libraries is desirable. The goal of this comparison is to evaluate the differences and implications for the STS activation analysis. Overall, the total activity differs between CINDER2008 and CINDER90 by no more than 20% for the materials evaluated in this report. The largest discrepancies were observed in the decay gamma intensity densities with CINDER90 calculating a factor of 2 higher than CINDER2008.

97 MATHEMATICS AND COMPUTING↗

ORNL Second Target Station Project: Biological & Environmental Science Workshop

Recent advances in neutron sources and instrumentation have opened up many new opportunities for the application of neutron scattering techniques in the biological and environmental sciences. Neutrons enable studies of the structure and dynamics of biological and environmental samples with a particular sensitivity to light elements, such as hydrogen, which is a key component of biological and environmental samples. Studies using neutrons are complementary to X-rays and have the unique advantage of being non-destructive and highly-penetrating. Oak Ridge National Laboratory’s upcoming Spallation Neutron Source (SNS) Second Target Station (STS) will provide high brightness cold neutron sources that significantly advance the scientific capabilities of neutron scattering instruments. The STS will advance our understanding of biological and environmental processes across spatial and temporal scales. The capabilities will enhance our ability to discover, design, and develop new materials essential for advanced sustainable technologies to address society’s most pressing needs. This report summarizes the discussions and recommendations from a joint workshop held by the STS Project and the Biological and Environmental Systems Science Directorate (BESSD) in June 2022. The purpose of the workshop was to explore science opportunities and capabilities related to biological and environmental systems that could be incorporated into both current and future STS instrument designs, as well as additional instruments at the SNS First Target Station (FTS) and High Flux Isotope Reactor (HFIR). With six breakout sessions, each with two invited plenary speakers from other institutions, the participants discussed a wide range of topics relevant to biological and environmental research. Based on the input from participants, a number of recommendations on instrumentation, sample environments, complementary multi-modal methods, data processing and analysis and sample deuteration are provided in the report. The participants also identified science opportunities that are emerging from the planned instrument capabilities at STS. Selected recommendations and science opportunities are listed in the Executive Summary.

54 ENVIRONMENTAL SCIENCES↗

Magnetic Designs of New First Target Beamline Magnets for the ORNL SNS Upgrade

The Spallation Neutron Source (SNS) at ORNL currently is being upgraded from 1.0 GeV to 1.3 GeV. Several water-cooled magnets should be upgraded to transport 30% of higher beam energy. New chicane, injection/extraction septum, and Lambertson magnets were designed. Designing the magnets was a challenging task because the new magnets required good combined integrated field quality and needed to occupy the old magnets space but with about 20% greater integrated magnetic field. Additional strong requirements applied to the magnets fringe field do not disturb the circulating beam. The special field profiles had to be provided in foil areas between magnets. The analysis described here was based on OPERA3D simulations. A special technique was used for analyzing the integrated field harmonics. Initially, the particle track was simulated, and integrated field components were calculated along this track for the reference radius, which were used for the harmonics analysis. In addition, 3D field maps were provided for beam optics simulations. The final beamline analysis confirmed good beam transmission and low losses.

3d field maps↗

Calibration of the 2-Phase Bubble Tracking Model for Liquid Mercury Target Simulation with Machine Learning Surrogate Models

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is one of the most powerful accelerator-driven neutron sources in the world. The intense protons strike on SNS's mercury target to provide bright neutron beams, which also leads to severe fluid-structure interactions inside the target. Prediction of resultant loading on the target is difficult particularly when helium gas is injected into mercury to reduce the loading and mitigate the pitting damage on vessel walls. A 2-phase material model that incorporates the Rayleigh-Plesset (R-P) model is expected to address this multi-physics problem. However, several uncertain parameters in the R-P model require intensive simulations to determine their optimal values. With the help of machine learning and the measured target strain, we have studied the major uncertain parameters in this R-P model and developed a framework to identify optimal parameters that significantly reduce the discrepancy between simulations and experimental strains. The preliminary results show the possibility of using this mercury/helium mixture and surrogate models to predict a better match of target strain response when the helium gas is injected.

Lin, Lianshan↗

Optimization of the Second Target Station cold source moderators using an automated workflow

The Second Target Station (STS) at the US Department of Energy’s Oak Ridge National Laboratory is designed to become the world’s highest peak-brightness spallation source of cold neutrons. Successful completion of the STS, which is currently in the preliminary design phase, will provide transformative new capabilities to examine novel materials for future technologies. At STS, neutrons will be generated by spallation reactions in a solid tungsten target. They will be moderated and thermalized in two cold (20 K) para-hydrogen moderators. Careful optimization of these moderators is essential to the project’s success. To find optimal moderator designs, an advanced optimization workflow integrates high-fidelity neutronics calculations using the Monte Carlo N-Particle (MCNP) transport code MCNP6.2 with state-of-the-art optimization algorithms in the Dakota optimization toolkit. For each design iteration, a parametrized solid CAD geometry is generated in Creo and automatically converted into an unstructured mesh geometry by Attila 4MC for the neutronics calculation with MCNP. Iterations repeat until optimal designs are found. Herein this paper presents the results of a sensitivity and optimization study for the cylindrical and tube moderators. Both moderators can be optimized for maximum peak brightness, maximum time-integrated brightness, or any combination between these extremes. Maximum peak brightness is achieved by using smaller optimal dimensions of the moderators, whereas maximum time-integrated brightness is achieved by using larger dimensions. A Pareto front details the designs that optimally balance both brightness metrics. The Pareto front can be found in only 40–110 iterations with 4–5 design parameters when using the efficient global and Pareto-set optimization algorithms in Dakota. Additionally, important engineering constraints can be taken into account, such as the coupling between the cylindrical moderator radius and aluminum vessel wall thicknesses required to ensure structural integrity of the vessels. This interaction has a significant impact on the resulting optimal designs. Our new, highly efficient, fully automated optimization workflow will be used to optimize additional STS components in the future and can be adopted for design and optimization studies at other experimental neutron and accelerator facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗