A Polarimeter for SOFIA: Summary of Research

The purpose of this research was to study designs for a far-infrared polarimeter for SOFIA that would greatly surpass the performance of the earlier polarimeter, Stokes, used on the Kuiper Airborne Observatory. Specifically we wished to gain the sensitivity to observe much fainter objects, to provide a choice of passbands, to reduce systematic errors, and to improve the efficiency. All of these objectives were successfully addressed. The gain in sensitivity will be achieved in part by the superior capabilities of SOFIA but to an even greater extent by the incorporation of new-technology detector arrays. We are developing superconducting transition-edge detectors using the "pop-up" design conceived by Dr. Harvey Moseley. The choice of passbands is achieved by providing three alternative optical paths, each with its own spectral filter, half-wave plate, and pupil tens. A new investigation has shown that multiwavelength observations provide an essential feature of far-infrared polarimetry. The principal source of systematic errors in observations of extended objects has been unknown polarization in the reference beams. We have developed a strategy for estimating these errors.

Hildebrand, Roger H.↗

Coronagraphic Notch Filter for Raman Spectroscopy

A modified coronagraph has been proposed as a prototype of improved notch filters in Raman spectrometers. Coronagraphic notch filters could offer alternatives to both (1) the large and expensive double or triple monochromators in older Raman spectrometers and (2) holographic notch filters, which are less expensive but are subject to environmental degradation as well as to limitations of geometry and spectral range. Measurement of a Raman spectrum is an exercise in measuring and resolving faint spectral lines close to a bright peak: In Raman spectroscopy, a monochromatic beam of light (the pump beam) excites a sample of material that one seeks to analyze. The pump beam generates a small flux of scattered light at wavelengths slightly greater than that of the pump beam. The shift in wavelength of the scattered light from the pump wavelength is known in the art as the Stokes shift. Typically, the flux of scattered light is of the order of 10 7 that of the pump beam and the Stokes shift lies in the wave-number range of 100 to 3,000 cm 1. A notch filter can be used to suppress the pump-beam spectral peak while passing the nearby faint Raman spectral lines. The basic principles of design and operation of a coronagraph offer an opportunity for engineering the spectral transmittance of the optics in a Raman spectrometer. A classical coronagraph may be understood as two imaging systems placed end to end, such that the first system forms an intermediate real image of a nominally infinitely distant object and the second system forms a final real image of the intermediate real image. If the light incident on the first telescope is collimated, then the intermediate image is a point-spread function (PSF). If an appropriately tailored occulting spot (e.g., a Gaussian-apodized spot with maximum absorption on axis) is placed on the intermediate image plane, then the instrument inhibits transmission of light from an on-axis source. However, the PSFs of off-axis light sources are formed off axis - that is, away from the occulting spot - so that they become refocused onto the final image plane.

Cohen, David↗

Optical recognition of constructs using hyperspectral imaging and detection (ORCHID)

Abstract Challenges to deep sample imaging have necessitated the development of special techniques such as spatially offset optical spectroscopy to collect signals that have travelled through several layers of tissue. However, these techniques provide only spectral information in one dimension (i.e., depth). Here, we describe a general and practical method, referred to as Optical Recognition of Constructs Using Hyperspectral Imaging and Detection (ORCHID). The sensing strategy integrates (1) the spatial offset detection concept by computationally binning 2D optical data associated with digital offsets based on selected radial pixel distances from the excitation source; (2) hyperspectral imaging using tunable filter; and (3) digital image binding and collation. ORCHID is a versatile modality that is designed to collect optical signals deep inside samples across three spatial (X, Y, Z) as well as spectral dimensions. The ORCHID method is applicable to various optical techniques that exhibit narrow-band structures, from Raman scattering to quantum dot luminescence. Samples containing surface-enhanced Raman scattering (SERS)-active gold nanostar probes and quantum dots embedded in gel were used to show a proof of principle for the ORCHID concept. The resulting hyperspectral data cube is shown to spatially locate target emitting nanoparticle volumes and provide spectral information for in-depth 3D imaging.

47 OTHER INSTRUMENTATION↗

Miniaturized, 9-12 micron heterodyne spectrometer with space qualifiable design features

A demonstration-prototype CO2-laser heterodyne spectrometer operating at 9-12 microns and suitable for long-term space missions is described and illustrated with extensive diagrams, drawings, photographs, and graphs of test performance data. The spectrometer has total volume 0.63 cu m, mass 30 kg, and power requirement 60-70 W, compatible with miniature-class Space Shuttle experiment payload specifications. It comprises three modules: (1) an optical front end with reflecting optics, a 2-GHz BW HgCdTe photomixer, and a 0-2-GHz 40-dB RF preamplifier; (2) a local oscillator with an RF-excited waveguide CO2 laser, a 75-percent-efficiency RF amplifier, a stepper-driven grating mode selector, and an etalon stabilized for over 30,000 h of use; and (3) an RF-filter-bank spectral-line receiver with a 25-MHz RF channel, 1.6-GHz IF spectral coverage, onboard instrument control, a serial link to the host computer, and highly integrated design.

Glenar, D. A.↗

Design of the focal plane array assembly for the Mars Observer/Visual and Infrared Mapping Spectrometer (MO/VIMS)

A unique focal plane array (FPA) assembly combining both electronic and optical components in a single hermetically sealed hybrid package has been designed to meet the performance requirements imposed on the focal plane assembly in the Visual and Infrared Mapping Spectrometer (VIMS) for the Mars Observer (MO) mission. Inside the FPA package is a configuration of three multiplexed linear arrays containing 320 detector elements, a combination of Si and InSb, allowing continuous spectral coverage from 0.35 to 5.14 microns. An optical subassembly consisting of two spectral order-sorting filters with intrinsic field-of-view apertures requiring critical optical alignment is also internal to the hybrid. Several engineering issues arose during the MO/VIMS FPA development phase which had challenging design ramifications. FPA performance requirements, design approach, and critical issues are discussed.

Niblack, Curtiss A.↗

Development and Operation of a Material Identification and Discrimination Imaging Spectroradiometer

Many imaging applications require quantitative determination of a scene's spectral radiance. This paper describes a new system capable of real-time spectroradiometric imagery. Operating at a full-spectrum update rate of 30Hz, this imager is capable of collecting a 30 point spectrum from each of three imaging heads: the first operates from 400 nm to 950 nm, with a 2% bandwidth; the second operates from 1.5 micro-m to 5.5 micro-m with a 1.5% bandwidth; the third operates from 5 micro-m to 12 micro-m, also at a 1.5% bandwidth. Standard image format is 256 x 256, with 512 x 512 possible in the VIS/NIR head. Spectra of up to 256 points are available at proportionately lower frame rates. In order to make such a tremendous amount of data more manageable, internal processing electronics perform four important operations on the spectral imagery data in real-time. First, all data in the spatial/spectral cube of data is spectro-radiometrically calibrated as it is collected. Second, to allow the imager to simulate sensors with arbitrary spectral response, any set of three spectral response functions may be loaded into the imager including delta functions to allow single wavelength viewing; the instrument then evaluates the integral of the product of the scene spectral radiances and the response function. Third, more powerful exploitation of the gathered spectral radiances can be effected by application of various spectral-matched filtering algorithms to identify pixels whose relative spectral radiance distribution matches a sought-after spectral radiance distribution, allowing materials-based identification and discrimination. Fourth, the instrument allows determination of spectral reflectance, surface temperature, and spectral emissivity, also in real-time. The spectral imaging technique used in the instrument allows tailoring of the frame rate and/or the spectral bandwidth to suit the scene radiance levels, i.e., frame rate can be reduced, or bandwidth increased to improve SNR when viewing low radiance scenes. The unique challenges of design and calibration are described. Pixel readout rates of 160 MHz, for full frame readout rates of 1000 Hz (512 x 512 image) present the first challenge; processing rates of nearly 600 million integer operations per second for sensor emulation, or over 2 billion per second for matched filtering, present the second. Spatial and spectral calibration of 66,536 pixels (262,144 for the 512 x 512 version) and up to 1,000 spectral positions mandate novel decoupling methods to keep the required calibration memory to a reasonable size. Large radiometric dynamic range also requires care to maintain precision operation with minimum memory size.

Dombrowski, Mark↗

Digital Signal Processing Techniques for the GIFTS SM EDU

The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Sensor Module (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiance using a Fourier transform spectrometer (FTS). The GIFTS instrument employs three Focal Plane Arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes several digital signal processing (DSP) techniques involved in the development of the calibration model. In the first stage, the measured raw interferograms must undergo a series of processing steps that include filtering, decimation, and detector nonlinearity correction. The digital filtering is achieved by employing a linear-phase even-length FIR complex filter that is designed based on the optimum equiripple criteria. Next, the detector nonlinearity effect is compensated for using a set of pre-determined detector response characteristics. In the next stage, a phase correction algorithm is applied to the decimated interferograms. This is accomplished by first estimating the phase function from the spectral phase response of the windowed interferogram, and then correcting the entire interferogram based on the estimated phase function. In the calibration stage, we first compute the spectral responsivity based on the previous results and the ideal Planck blackbody spectra at the given temperatures, from which, the calibrated ambient blackbody (ABB), hot blackbody (HBB), and scene spectra can be obtained. In the post-calibration stage, we estimate the Noise Equivalent Spectral Radiance (NESR) from the calibrated ABB and HBB spectra. The NESR is generally considered as a measure of the instrument noise performance, and can be estimated as the standard deviation of calibrated radiance spectra from multiple scans. To obtain an estimate of the FPA performance, we developed an efficient method of generating pixel performance assessments. In addition, a random pixel selection scheme is developed based on the pixel performance evaluation. This would allow us to perform the calibration procedures on a random pixel population that is a good statistical representation of the entire FPA. The design and implementation of each individual component will be discussed in details.

Tian, Jialin↗

EMI Mitigation of a Ćuk-Based Power-Electronic System Using Switching-Sequence-Based Control

Switching-sequence-based control (SBC) laws when designed based on topological switching behavior can have positive effects on slow- and fast-scale dynamics of a power-electronic system (PES). The slow-scale control can encompass fast PES state regulation and tracking, based on predefined objective, while fastscale control can address differential-mode (DM) and commonmode (CM) spectral-peak energy associated with PES switching operation. Such control laws may offer enhanced programmability to conventional PES design where bulky electromagnetic interference (EMI) filters have been traditionally used to reduce EMI of switching power converters to meet EMI regulatory standards. An EMI filter is always a less programmable solution since it is usually designed for the worst-case EMI mitigation and usually overkill for a PES operating under reduced load condition. The control scheme outlined in this article offers EMI mitigation across wide operating regions without compromising PES regulation. Moreover, it does so by use of switching sequences that guarantee the reachability of the PES dynamics using an advanced Lyapunov-function-based approach. SBC is a powerful tool to generate control actions for a PES based on multivariate PES state constraints. Hence, contemporary EMI regulatory standards are used as constraints in the SBC formulation to operate the PES under wide operating regime while autonomously mitigating the EMI levels. The work may be of paramount importance for operating the ultra-fast-transition recent wide-bandgap semiconductor devices like GaN–FET and SiC MOSFET under higher power with increasing switching frequencies, which is usually desirable for increased power density and reduced switching losses. Here, a hardware Cuk–PES operated ´ with GaN–FETs is fabricated and is used for case illustration. It is shown by experimental results how SBC mitigate DM and CM EMI noise of the PES while maintaining regulation even for the higher order nonminimum phase PES, while reducing sensor requirements using state observer derived from the switching model of the PES.

42 ENGINEERING↗

Mosaic-Detector-Based Fluorescence Spectral Imager

A battery-powered, pen-sized, portable instrument for measuring molecular fluorescence spectra of chemical and biological samples in the field has been proposed. Molecular fluorescence spectroscopy is among the techniques used most frequently in laboratories to analyze compositions of chemical and biological samples. Heretofore, it has been possible to measure fluorescence spectra of molecular species at relative concentrations as low as parts per billion (ppb), with a few nm spectral resolution. The proposed instrument would include a planar array (mosaic) of detectors, onto which a fluorescence spectrum would be spatially mapped. Unlike in the larger laboratory-type molecular fluorescence spectrometers, mapping of wavelengths to spatial positions would be accomplished without use of relatively bulky optical parts. The proposed instrument is expected to be sensitive enough to enable measurement of spectra of chemical species at relative concentrations <1 ppb, with spectral resolution that could be tailored by design to be comparable to a laboratory molecular fluorescence spectrometer. The proposed instrument (see figure) would include a button-cell battery and a laser diode, which would generate the monochromatic ultraviolet light needed to excite fluorescence in a sample. The sample would be held in a cell bounded by far-ultraviolet-transparent quartz or optical glass. The detector array would be, more specifically, a complementary metal oxide/ semiconductor or charge-coupled- device imaging photodetector array, the photodetectors of which would be tailored to respond to light in the wavelength range of the fluorescence spectrum to be measured. The light-input face of the photodetector array would be covered with a matching checkerboard array of multilayer thin film interference filters, such that each pixel in the array would be sensitive only to light in a spectral band narrow enough so as not to overlap significantly with the band of an adjacent pixel. The wavelength interval between adjacent pixels (and, thus, the spectral resolution) would typically be chosen by design to be approximately equal to the width of the total fluorescence wavelength range of interest divided by the number of pixels. The unitary structure comprising the photodetector array overlaid with the matching filter array would be denoted a hyperspectral mosaic detector (HMD) array.

Son, Kyung-Ah↗

Optimum design and performance of Costas receivers containing soft bandpass limiters

This paper investigates several key questions concerning the mechanization and design of a Costas receiver for reconstruction of a carrier from a suppressed carrier signal. For baseband NRZ encoded data symbols and a soft bandpass limiter preceding the loop, several design issues which are considered herein and which affect acquisition and tracking performance are: (1) The choice of an IF bandwidth. (2) The optimum choice of the Costas arm filter bandwidths as well as the spectral roll-off characteristics. (3) The optimum choice of loop bandwidth to data rate ratio for a given signal-to-noise ratio. (4) The signal suppression factor and the combined limiter-squaring loss. (5) The variations in loop bandwidth and damping with signal level. (6) The choice of the limiter transfer characteristic. (7) Performance degradation due to the presence of a limiter. Various new results in system design are presented and typical numerical results are given and graphically demonstrated in SNR regions of practical interest. The theory is applicable to the design of carrier reconstruction loops required in the implementation of spread spectrum communication receivers.

Lindsey, W. C.↗

Synthetic aperture radar system design for random field classification

An optimum design study is carried out for synthetic aperture radar systems intended for classifying randomly reflecting areas (such as agricultural fields) characterized by a reflectivity density spectral density. The problem solution is obtained, neglecting interfield interference and assuming areas of known configuration and location, as well as a certain Gaussian signal field property. The optimum processor is nonlinear, but includes conventional matched filter processing. A set of summary design curves is plotted, and is applied to the design of a satellite synthetic aperture radar system.

Harger, R. O.↗

Solar Confocal interferometers for Sub-Picometer-Resolution Spectral Filters

The confocal Fabry-Perot interferometer allows sub-picometer spectral resolution of Fraunhofer line profiles. Such high spectral resolution is needed to keep pace with the higher spatial resolution of the new set of large-aperture solar telescopes. The line-of-sight spatial resolution derived for line profile inversions would then track the improvements of the transverse spatial scale provided by the larger apertures. In particular, profile inversion allows improved velocity and magnetic field gradients to be determined independent of multiple line analysis using different energy levels and ions. The confocal interferometer's unique properties allow a simultaneous increase in both etendue and spectral power. The higher throughput for the interferometer provides significant decrease in the aperture, which is important in spaceflight considerations. We have constructed and tested two confocal interferometers. A slow-response thermal-controlled interferometer provides a stable system for laboratory investigation, while a piezoelectric interferometer provides a rapid response for solar observations. In this paper we provide design parameters, show construction details, and report on the laboratory test for these interferometers. The field of view versus aperture for confocal interferometers is compared with other types of spectral imaging filters. We propose a multiple etalon system for observing with these units using existing planar interferometers as pre-filters. The radiometry for these tests established that high spectral resolution profiles can be obtained with imaging confocal interferometers. These sub-picometer spectral data of the photosphere in both the visible and near-infrared can provide important height variation information. However, at the diffraction-limited spatial resolution of the telescope, the spectral data is photon starved due to the decreased spectral passband.

Gary, G. Allen↗

Carrier Estimation Using Classic Spectral Estimation Techniques for the Proposed Demand Assignment Multiple Access Service

In any satellite communication, the Doppler shift associated with the satellite's position and velocity must be calculated in order to determine the carrier frequency. If the satellite state vector is unknown then some estimate must be formed of the Doppler-shifted carrier frequency. One elementary technique is to examine the signal spectrum and base the estimate on the dominant spectral component. If, however, the carrier is spread (as in most satellite communications) this technique may fail unless the chip rate-to-data rate ratio (processing gain) associated with the carrier is small. In this case, there may be enough spectral energy to allow peak detection against a noise background. In this thesis, we present a method to estimate the frequency (without knowledge of the Doppler shift) of a spread-spectrum carrier assuming a small processing gain and binary-phase shift keying (BPSK) modulation. Our method relies on an averaged discrete Fourier transform along with peak detection on spectral match filtered data. We provide theory and simulation results indicating the accuracy of this method. In addition, we will describe an all-digital hardware design based around a Motorola DSP56303 and high-speed A/D which implements this technique in real-time. The hardware design is to be used in NMSU's implementation of NASA's demand assignment, multiple access (DAMA) service.

Scaife, Bradley James↗

Spinning metasurface stack for spectro-polarimetric thermal imaging

Spectro-polarimetric imaging in the long-wave infrared (LWIR) region plays a crucial role in applications from night vision and machine perception to trace gas sensing and thermography. However, the current generation of spectro-polarimetric LWIR imagers suffers from limitations in size, spectral resolution, and field of view (FOV). While meta-optics-based strategies for spectro-polarimetric imaging have been explored in the visible spectrum, their potential for thermal imaging remains largely unexplored. In this work, we introduce an approach for spectro-polarimetric decomposition by combining large-area stacked meta-optical devices with advanced computational imaging algorithms. The co-design of a stack of spinning dispersive metasurfaces along with compressive sensing and dictionary learning algorithms allows simultaneous spectral and polarimetric resolution without the need for bulky filter wheels or interferometers. Our spinning-metasurface-based spectro-polarimetric stack is compact (<10×10×10cm) and robust, and it offers a wide field of view (20.5°). We show that the spectral resolving power of our system substantially enhances performance in machine learning tasks such as material classification, a challenge for conventional panchromatic thermal cameras. Our approach represents a significant advance in the field of thermal imaging for a wide range of applications including heat-assisted detection and ranging (HADAR).

Optics↗

Cloud Top Scanning radiometer (CTS)

A scanning radiometer to be used for measuring cloud radiances in each of three spectral regions is described. Significant features incorporated in the Cloud Top Scanner design are: (1) flexibility and growth potential through use of easily replaceable modular detectors and filters; (2) full aperture, multilevel inflight calibration; (3) inherent channel registration through employment of a single shared field stop; and (4) radiometric sensitivity margin in a compact optical design through use of Honeywell developed (Hg,Cd)Te detectors and preamplifiers.

Source record↗

Video image processing

Current technology projections indicate a lack of availability of special purpose computing for Space Station applications. Potential functions for video image special purpose processing are being investigated, such as smoothing, enhancement, restoration and filtering, data compression, feature extraction, object detection and identification, pixel interpolation/extrapolation, spectral estimation and factorization, and vision synthesis. Also, architectural approaches are being identified and a conceptual design generated. Computationally simple algorithms will be research and their image/vision effectiveness determined. Suitable algorithms will be implimented into an overall architectural approach that will provide image/vision processing at video rates that are flexible, selectable, and programmable. Information is given in the form of charts, diagrams and outlines.

Murray, N. D.↗

Lunar multispectral mosaics from Galileo's second Earth-Moon flyby

Galileo's Solid-State Imaging (SSI) experiment acquired about 800 images of the Moon from the second Earth-Moon flyby (EM2) in December of 1992. Ten major sequences were acquired; each consists of mosaics of the entire or nearly entire visible and illuminated surface from each viewing geometry in at least six spectral filters (effective wavelengths for the Moon of 420, 564, 660, 756, 890, and 990 nm). The geometries of LUNMOS numbers 3, 4, 5, and 6 were designed to provide stereo data at the best possible resolutions. The purpose of this abstract is to describe the sequences, calibration, processing, and mosaicking, and to present a set of color products in a poster session.

Mcewen, A. S.↗