Search NASA⌕ Search

SEARCH · Search NASA

Results for “split cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Assessment of the US Department of Energy's Sustainable Energy Resources for Consumers Grant Program

This report presents the results of an assessment of the Sustainable Energy Resources for Consumers (SERC) grant program that was administered by the US Department of Energy Weatherization and Intergovernmental Program Office. Grants totaling $90 million were awarded to 101 local weatherization agencies located in 27 states. More than 15,000 housing units were touched by the SERC program. Close to 29,000 SERC technologies were installed and/or services delivered. The report summarizes the results of site visits to 27 agencies in which the following 14 technologies were observed: solar photovoltaic panels, solar hot water heaters, solar thermal air panels for space heating, tankless water heaters, heat pump water heaters, geothermal heat pumps, super-evaporative cooling systems, combination boilers and indirect water heaters, small-scale residential wind systems, cool roofs, masonry spray foam insulation, attic radiant barriers, mini-split heat pumps, and in-home energy monitors. The evaluation found that the national weatherization network is capable of installing and delivering a wide range of new and innovative technologies, but the usability and adoptability of some technologies may prove impractical for the weatherization network and the demographic for which it serves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Landsat Data Continuity Mission

The Landsat Data Continuity Mission (LDCM) is currently under development and is on schedule to launch the 8th satellite in the Landsat series in December of 2012. LDCM is a joint project between the National Aeronautics and Space Administration (NASA) and the United States Geological Survey (USGS). NASA is responsible for developing and launching the flight hardware and on-orbit commissioning and USGS is responsible for developing the ground system and operating the system onorbit after commissioning. Key components of the flight hardware are the Operational Land Imager (OLI), nearing completion by Ball Aerospace & Technologies Corp in Boulder, CO, the Thermal Infrared Sensor (TIRS), being built by NASA's Goddard Space Flight Center and the spacecraft, undergoing integration at Orbital Sciences Corp in Gilbert, Arizona. The launch vehicle will be an Atlas-5 with launch services provided by NASA's Kennedy Space Center. Key ground systems elements are the Mission Operations Element, being developed by the Hammers Corporation, and the Collection Activity Planning Element, Ground Network Element, and Data Processing and Archive System, being developed internally by the USGS Earth Resources Observations and Science (EROS) Center. The primary measurement goal of LDCM is to continue the global coverage of moderate spatial resolution imagery providing continuity with the existing Landsat record. The science goal for this imagery is to monitor land use and land cover, particularly as it relates to global climate change. Together the OLI and TIRS instruments on LDCM replace the ETM+ instrument on Landsat-7 with significant enhancements. The OLI is a pushbroom design instrument where the scanning mechanism of the ETM+ is effectively replaced by a long line of detectors. The OLI has 9 spectral bands with similar spatial resolution to ETM+: 7 of them similar to the reflective spectral bands on ETM+ and two new bands. The two new bands cover (1) the shorter wavelength blue part of the spectrum to help with coastal studies and aerosol analyses/atmospheric correction and (2) an atmospheric water absorption band, where the Earth surface is generally not visible, but Cirrus clouds are, to aid in cloud detection and screening. The radiometry of OLI benefits from improved SNR, dynamic range and quantization. OLI is undergoing system testing with a delivery scheduled for Spring 2011. The TIRS is also a pushbroom design and used QWIPS detectors that require cooling to 43K using a cryocooler. It.has two spectral bands, effectively splitting the ETM+ band 6 in half, that can be used as a split window to aid in atmospheric correction. It has nominally 100 m spatial resolution as opposed to the 60 m of Landsat-7 ETM+: TIRS has commenced integration and test, with a delivery to the spacecraft vendor scheduled for Winter 2011-2012. The Orbital spacecraft currently being integrated for LDCM will have improved capabilities for pointing over previous missions. These capabilities will allow the OLI and TIRS instruments to point off-nadir the equivalent of one WRS-2 path to increase the chances of coverage for high priority targets, particularly in the event of natural disasters. Also, the pointing capability will allow the calibration of the OLI using the sun (roughly weekly), the moon (monthly), stars (during commissioning) and the Earth (at 90 deg from normal orientation, a.k.a., side slither) quarterly. The solar calibration will be used for OLI absolute and relative calibration, the moon for trending the stability of the OLI response, the stars will be used for Line of Sight determination and the side slither will be an alternate OLI and relative gain determination methodology. The spacecraft is scheduled to begin integration with the OLI instrument in Summer 2011. The LDCM data processing and archive system (DPAS), located at USGS EROS, generates the products for distribution to users. Like Landsat-7 this includes an image assessment system for characrizing instrument performance and updating calibration parameters. Products will be generated that include the spectral bands from both instruments, terrain corrected and registered to the geoid. Also, like Landsat-7, data products will be distributed at no charge to the user. The current status and plans of the space and ground segments of the LDCM project will be presented along with performance predictions as available. More detailed information on the two instruments is intended to be presented in separate papers.

Markham, Brian↗

Infrared spectroscopy and tunneling dynamics of the vinyl radical in 4 He nanodroplets

Here, the vinyl radical has been trapped in 4 He nanodroplets and probed with infrared laser spectroscopy in the CH stretch region between 2850 and 3200 cm -1 . The assigned band origins for the CH 2 symmetric (ν 3 ), CH 2 antisymmetric (ν 2 ), and lone α-CH stretch (ν 1 ) vibrations are in good agreement with previously reported full-dimensional vibrational configuration interaction computations. For all three bands, a-type and b-type transitions are observed from the lowest symmetry allowed roconvibrational state of each nuclear spin isomer, which allows for a determination of the tunneling splittings in both the ground and excited vibrational levels. Comparisons to gas phase millimeter-wave rotation-tunneling and high-resolution jet-cooled infrared spectra reveal that the He solvent effect is to reduce the ground and ν 3 excited state tunneling splittings by ≈20%. This solvent-induced modification of the tunneling dynamics can be reasonably accounted for by assuming either a ≈2.5% increase in the effective barrier height along the tunneling coordinate or a ≈5% increase in the effective reduced mass of the tunneling particles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The suppression of pulsar and gamma-ray burst annihilation lines by magnetic photon splitting

Neutron stars, relativistic and compact by nature, show great potential for the copious creation of electron-positron pairs in the magnetospheres; these rapidly cool, thermalize, and then annihilate. It is therefore expected that many neutron sources might display evidence of pair annihilation lines in the 400-500 keV range. It is shown that magnetic photon splitting, which operates effectively at these energies and in the enormous neutron star magnetic fields, can destroy an annihilation feature by absorbing line photons and reprocessing them to lower energies. In so doing, photon splitting creates a soft gamma-ray bump and a broad quasi-power-law contribution to the X-ray continuum, which is too flat to conflict with the observed X-ray paucity in gamma-ray bursts. The destruction of the line occurs in neutron stars with surface fields of 5 x 10 exp 12 G or maybe even less, depending on the size of the emission region.

Baring, Matthew G.↗

Energy Performance Comparison of Heating and Air Conditioning Systems for Multi-Family Residential Buildings

The type of heating, ventilation and air conditioning (HVAC) system has a large impact on the heating and cooling energy consumption in multifamily residential buildings. This paper compares the energy performance of three HVAC systems: a direct expansion (DX) split system, a split air source heat pump (ASHP) system, and a closed-loop water source heat pump (WSHP) system with a boiler and an evaporative fluid cooler as the central heating and cooling source. All three systems use gas furnace for heating or heating backup. The comparison is made in a number of scenarios including different climate conditions, system operation schemes and applicable building codes. It is found that with the minimum code-compliant equipment efficiency, ASHP performs the best among all scenarios except in extremely code climates. WSHP tends to perform better than the split DX system in cold climates but worse in hot climates.

15 GEOTHERMAL ENERGY↗

Superconducting Magnet Performance in LCLS-II Cryomodules

New LCLS-II Linear Superconducting Accelerator Cry-omodules are under construction at Fermilab. Installed in-side each SCRF Cryomodule is a superconducting magnet package to focus and steer an electron beam. The magnet package is an iron dominated configuration with conduc-tively cooled racetrack-type quadrupole and dipole coils. For easier installation the magnet can be split in the vertical plane. Initially the magnet was tested in a liquid helium bath, and high precision magnetic field measurements were performed. The first (prototype) Cryomodule with the magnet inside was built and successfully tested at Fermilab test facility. In this paper the magnet package is discussed, the Cryomodule magnet test results and current leads con-duction cooling performance are presented. So far magnets in nine Cryomodules were successfully tested at Fermilab.

Kashikhin, V.↗

PRE-FLARE CORONAL JET AND EVOLUTIONARY PHASES OF A SOLAR ERUPTIVE PROMINENCE ASSOCIATED WITH THE M1.8 FLARE: SDO AND RHESSI OBSERVATIONS

We investigate the triggering, activation, and ejection of a solar eruptive prominence that occurred in a multi-polar flux system of active region NOAA 11548 on 2012 August 18 by analyzing data from the Atmospheric Imaging Assembly on board the Solar Dynamics Observatory , the Reuven Ramaty High Energy Solar Spectroscopic Imager , and the Extreme Ultraviolet Imager/Sun Earth Connection Coronal and Heliospheric Investigation on board the Solar Terrestrial Relation Observatory . Prior to the prominence activation, we observed striking coronal activities in the form of a blowout jet, which is associated with the rapid eruption of a cool flux rope. Furthermore, the jet-associated flux rope eruption underwent splitting and rotation during its outward expansion. These coronal activities are followed by the prominence activation during which it slowly rises with a speed of ∼12 km s{sup −1} while the region below the prominence emits gradually varying EUV and thermal X-ray emissions. From these observations, we propose that the prominence eruption is a complex, multi-step phenomenon in which a combination of internal (tether-cutting reconnection) and external (i.e., pre-eruption coronal activities) processes are involved. The prominence underwent catastrophic loss of equilibrium with the onset of the impulsive phase of an M1.8 flare, suggesting large-scale energy release by coronal magnetic reconnection. We obtained signatures of particle acceleration in the form of power-law spectra with hard electron spectral index ( δ ∼ 3) and strong HXR footpoint sources. During the impulsive phase, a hot EUV plasmoid was observed below the apex of the erupting prominence that ejected in the direction of the prominence with a speed of ∼177 km s{sup −1}. The temporal, spatial, and kinematic correlations between the erupting prominence and the plasmoid imply that the magnetic reconnection supported the fast ejection of prominence in the lower corona.

79 ASTRONOMY AND ASTROPHYSICS↗

Operating characteristics of 120-millimeter-bore ball bearings at 3 million DN

A parametric study was performed with split inner-race 120-mm-bore angular-contact ball bearings at a speed of 25,000 rpm (3 million DN) at initial contact angles of 20 deg and 24 deg. Provisions were made for outer- and inner-race cooling and for injection of lubricant into the bearing through a number of radial holes in the split inner-race of the bearing. Oil flow and coolant rate to the bearing was controlled and varied for a total up to approximately 3.2 gal/min. Bearing temperature was found to decrease as the total lubricant flow to the bearing increased. However, at intermediate flow rates temperature began to increase with increasing flow. Power consumption increased with increasing flow rate. Bearing operating temperature, differences in temperatures between the inner and outer races, and bearing power consumption can be tuned to any desirable operating requirement. Cage speed increased by not more than 2 percent with increasing oil flow to the inner race.

Zaretsky, E. V.↗

Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Use in Quantum Data Centers: Scaling the Impact of Computer Architecture, Qubit Performance, Size, and Thermal Parameters

As quantum computers increase in size, the total energy used by a quantum data center, including the cooling, will become a greater concern. The cooling requirements of quantum computers, which operate at temperatures near absolute zero, are determined by computing system parameters, including the number and type of physical qubits, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. When combined with thermal system parameters such as cooling efficiency and cryostat heat transfer, the total energy use can be determined using a first-principles energy model. These models show that cooling of quantum computers differs in two fundamental ways from conventional data centers: (1) the energy required for cooling is much greater than the energy required for computation, and (2) the cooling loads are sensitive to the computational architecture. The temperature requirements for different qubit types can change energy requirements by orders of magnitude. Power use and computational power, as quantified by quantum volume, are analytically correlated. Approaches are identified for minimizing energy use in integrated quantum systems relative to computational power. Furthermore, designing a sustainable quantum computer will require both efficient cooling and system design that minimizes cooling requirements.

97 MATHEMATICS AND COMPUTING↗

Dynamically polarized target for the g p 2 and G p E experiments at Jefferson Lab

We describe a dynamically polarized target that has been utilized for two electron scattering experiments in Hall A at Jefferson Lab. The primary components of the target are a new, high cooling power 4 He evaporation refrigerator, and a re-purposed, superconducting split-coil magnet. It has been used to polarize protons in irradiated NH 3 at a temperature of 1 K and at fields of 2.5 and 5.0 Tesla. The performance of the target material in the electron beam under these conditions will be discussed. The maximum polarizations of 28% and 95% were obtained at those fields, respectively. To satisfy the requirements of both experiments, the magnet had to be routinely rotated between angles of 0, 6, and 90 degrees with respect to the incident electron beam. This was accomplished using a new rotating vacuum seal which permits rotations to be performed in only a few minutes.

43 PARTICLE ACCELERATORS↗

Connected Thermostat Alternatives for Room Air Conditioners and Minisplit Heat Pumps

The availability of smart, connected thermostats has improved climate control, energy efficiency, and grid demand-response programs for central HVAC systems. However, a significant gap exists in addressing integrated control systems for point-source heating and cooling systems such as window air-conditioners (window ACs) and mini-split heat pumps (MSHPs). This report examines the emerging market of third-party connected thermostats tailored for these systems, focusing on their effectiveness, reliability, and potential barriers to adoption.This study evaluates several commercially available products designed for room ACs and MSHPs through a series of laboratory tests. While these infrared-based (IR-based) thermostats offer remote temperature control and scheduling via mobile apps, our findings reveal that none are seamless, with reliability of basic functions being a critical factor. Promising features include integration of indoor air quality metrics and time-of-use pricing, but the latter are not yet available in the U.S. Barriers to broad user acceptance include non-seamless setup processes, challenges in thermostat placement, and unclear product differentiation. There is a pressing need for research and development in enabling MSHPs and central thermostats to coordinate, enhancing energy savings and comfort in retrofit applications. This study underscores the importance of further innovation in connected thermostat technology to address the diverse needs of single-zone HVAC systems and promote efficient energy management in households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hyperfine spectroscopy and laser cooling of the fermionic isotopes 47 Ti and 49 Ti

Here, we report on magneto-optical trapping of the two fermionic isotopes of atomic titanium, 47 Ti and 49 Ti . Unlike the even mass-number isotopes, which were recently laser cooled, 47 Ti and 49 Ti have nonzero nuclear spins and, consequently, their atomic levels are split by hyperfine structure. Combining and comparing theoretical calculations and atomic beam-spectroscopy measurements, we determine the hyperfine structures and isotope shifts of the 3⁢𝑑 2 ⁢4⁢𝑠 2 𝑎 3 ⁢𝐹 4 → 3⁢𝑑 2 ⁢( 3 𝑃)⁢4⁢𝑠⁢4⁢𝑝⁢( 3 𝑃 𝑜 ) 𝑦 5 ⁢𝐷$^o_4$ optical-pumping transition at optical wavelength 391 nm and the 3⁢𝑑 3 ⁢(4𝐹)⁢4⁢𝑠 𝑎 5 ⁢𝐹 5 → 3⁢𝑑 3 ⁢( 4 𝐹)⁢4⁢𝑝 𝑦 5 ⁢𝐺$^𝑜_6$ laser-cooling transition at wavelength 498 nm. With this information, we produce magneto-optical traps of both 47 Ti and 49 Ti by applying two additional tones of light to repump atoms to the maximum-spin states on the laser-cooling transition. Directly loading from the atomic flux of a titanium sublimation pump, we produce 47 Ti and 49 Ti traps with 731(190) and 1142(240) atoms, and with lifetimes of 330⁢(15) and 310⁢(8)⁢ ms, respectively.

atomic spectra↗

A transmissive concentrator photovoltaic module with cells directly cooled by silicone oil for solar cogeneration systems

Hybrid concentrator photovoltaic-thermal systems can cogenerate electricity and heat by beam-splitting incoming concentrated light onto photovoltaic cells and a thermal receiver to increase total conversion efficiency and potentially reduce system cost. To demonstrate this, we have designed and prototyped a transmissive spectrum-splitting concentrator photovoltaic module that maximizes solar energy conversion by utilizing the entire solar spectrum. Visible light is collected using infrared-transmissive triple-junction photovoltaic cells to achieve an in-band module efficiency of 43.3% for light of wavelength λ < 873 nm, while 44.2% of out-of-band light with λ > 873 nm is transmitted through for collection by a thermal receiver. During testing on a dual-axis tracked parabolic concentrator dish at up to 166 suns, cell temperatures were maintained at 119 °C or below via a novel active cooling method. This cooling system strictly flows silicone oil directly across both sides of the cells, without inhibiting optical transmission, as verified through experimentation and simulation. The module was validated outdoors for 572 sun·hrs, and achieved a maximum thermal receiver temperature of 180 °C. 86.1% of incident solar power is collected at 166 suns average concentration collectively among the electrical, cooling, and thermal receiver subsystems. The remaining 13.9% is lost to mirror reflectivity, dish shadowing, receiver reflection, and thermal losses. The ability to directly cool the cells with an inert silicone oil offers the potential for reduced system cost relative to previous transmissive hybrid concentrator photovoltaic-thermal systems, including microfluidic-cooled designs. This solar cogeneration capability is valuable in a wide range of commercial and industrial applications.

14 SOLAR ENERGY↗

Composite casting/bonding construction of an air-cooled, high temperature radial turbine wheel

A composite casting/bonding technique has been developed for the fabrication of a unique air-cooled, high temperature radial inflow turbine wheel design applicable to auxilliary power units with small rotor diameters and blade entry heights. The 'split blade' manufacturing procedure employed is an alternative to complex internal ceramic coring. Attention is given to both aerothermodynamic and structural design, of which the latter made advantageous use of the exploration of alternative cooling passage configurations through CAD/CAM system software modification.

Hammer, A. N.↗

Lab-scaled performance evaluation of novel water-lean solvents for post combustion CO 2 capture

Here, this work focuses on demonstrating the energetic performance and operational reliability in a continuous system of RTI's water-lean solvents for post-combustion CO 2 capture applications. RTI's Non-Aqueous Solvent, NAS-1A was subjected to 100 h of continuous, CO 2 capture and regeneration operation using a Lab-scale Gas Absorption System (LsGAS) while the CO 2 capture efficiency, mass balance, and total energy inputs were monitored. Throughout the test period, NAS-1A demonstrated stable operation with 90% CO 2 capture while requiring about 15% lower total energy input for solvent regeneration compared to 30 wt% monoethanolamine (MEA) solution. The use of a slipstream of CO 2 -rich solvent from the absorber sump reduced the regenerated CO 2 temperature before the gas was further cooled by the overhead condenser at the top of the desorber. The rich-split setup combined with a wash section may be an effective approach to remove water and solvent vapor from the regenerated CO 2 as well as to recover heat at the top of the desorber. NAS-1B was later developed and included a modifier component that lowers the heat of CO 2 absorption and reduces the vapor pressure of the amine component. The total energy inputs for 90% CO 2 capture with NAS-1B was found to be 25% less than that of the MEA. A gas chromatograph was used to monitor the amine concentration in the gas leaving the absorber wash section. It was found that under similar operating conditions, the presence of the modifier in NAS-1B reduces the amine in the absorber off-gas from 143 ppm in NAS-1A to 20 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Passive motion control of pneumatically driven displacers in cryogenic coolers

The split cryogenic cooler with a remote cold finger offers many advantages for use in cooling of infrared systems. A pneumatic drive for the displacer in such coolers was adopted in many cryocooler designs. This concept can be significantly improved by causing the displacer to move sinusoidally rather than in an essentially square wave, as in most of the present models. The way this motion was achieved passively is described and its advantages outlined. Data of minicoolers using this concept are presented.

Pundak, N.↗