Search NASA⌕ Search

SEARCH · Search NASA

Results for “stream flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Modeling of injected current stream-induced 3D perturbations in local helicity injection plasmas

Solenoid-free tokamak startup techniques are essential for spherical tokamaks and offer a pathway to cost reduction and design simplification in fusion energy systems. Local helicity injection (LHI) is one such approach, employing compact edge current sources to drive open field line current that initiates and sustains tokamak plasmas. The recently commissioned Pegasus-III Experiment provides a platform for advancing this and other solenoid-free startup methods. This study investigates the effect of LHI on magnetic topology in Pegasus-III plasmas. A helical filament model represents the injected current, and the linear plasma response to its three-dimensional field is calculated with M3D-C1. Poincaré mapping reveals substantial flux surface degradation in all modeled cases. The onset of overlapping magnetic structures and large-scale surface deformation begins near Ψ N ≈ 0.37, indicating a broad region of perturbed topology extending toward the edge. In rotating plasmas, both single-fluid and two-fluid models exhibit partial screening of the n = 1 perturbation, with two-fluid calculations showing stronger suppression near the edge. In contrast, the absence of rotation leads to strong resonant field amplification in the single-fluid case, while the two-fluid case with zero electron rotation mitigates this amplification and preserves edge screening. Magnetic probe measurements indicate that modeling the stream with spatial spreading—representing distributed current and/or oscillatory motion—better reproduces measured magnetic power profiles than a rigid filament model. The results underscore the role of rotation and two-fluid physics in screening stream perturbations and point to plasma flow measurements and refined stream models as key steps toward improving predictive fidelity.

Schaefer, Carolyn E. [Univ. of Wisconsin, Madison,↗

Growth of organized flow coherent motions within a single-stream shear layer: 4D-PTV measurements

Abstract This study investigates the evolution of a single-stream shear layer (SSSL) originating from a wall boundary layer past a backward-facing step. Utilizing a time-resolved 3D-Particle Tracking Velocimetry (4D-PTV) technique, we track the trajectories of fluorescent particles to gain insight into the flow characteristics of the SSSL. A compact water tunnel facility ( $$\textrm{Re}_\tau =1\,240$$ Re τ = 1 240 ) is fabricated to obtain an SSSL with a perpendicular slow entrainment stream past the separation edge. A hybrid interpolation approach that combines ensemble binning and Gaussian weighting is implemented to derive minimally filtered mean and instantaneous lower- and higher-order flow field parameters. Spanwise-dominant coherent motion accompanied by finer flow scales is observed to grow due to flow entrainment through “nibbling” actions of small-scale vortices, “engulfing” by large-scale vortices, and vortex pairing events. Furthermore, the non-zero-speed stream edge grows relatively faster than the zero-speed stream edge, showing a strong asymmetry in mixing composition across a mixing layer. The SSSL reaches self-similarity at a streamwise distance of $$\approx 55\,\theta _{0}$$ ≈ 55 θ 0 , where $$\theta _0$$ θ 0 is the initial momentum thickness from the separation edge, i.e., considerably shorter than reported in previous studies. A literature comparison of growth rate parameters raises intriguing questions regarding a potential inclusive growth scaling unifying the free shear layers. A turbulent kinetic energy (TKE) budget analysis reveals a negative production region immediately downstream of the separation edge attributed to a large positive streamwise gradient of streamwise velocity. In the self-similar region, the phase-averaged flow mapping demonstrates a larger concentration of turbulence production rate around the outer edges of spanwise vortices, specifically at the intersection of braids and vortices. Furthermore, a spatial separation exists in the regions of peak production and dissipation rates within the vortex core region favoring dissipation. The braids exhibit a larger concentration of turbulence diffusion rates, indicating their function as a conduit for exchanging turbulence between neighboring coherent motions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Utilization of Unmanned Aircraft Systems for Environmental Purposes at the Savannah River Site – 26578

Born in the 1950s, the Savannah River Plant was constructed as a plutonium and tritium production plant. As the Cold War era came and went, a change of direction was signaled when the name of the facility changed from Savannah River Plant to Savannah River Site (1989) – the main mission at Savannah River shifted from “production” to “cleanup.” The Department of Energy is responsible for managing the 310 square miles of land that is the Savannah River Site and the cleanup/remediation activities that occur. The Savannah River National Laboratory utilizes unmanned aircraft systems to assist with some of those environmental monitoring and remediation activities. One function of unmanned aircraft systems at the Savannah River National Laboratory is conducting aerial photography and videography. Various infrastructure evaluations have been performed with unmanned aircraft – facility rooftop inspections, water tower lock verifications, earthen dam surveys, etc. An unmanned aircraft system has been used for progress footage of remediation projects – Dunbarton Bay remediation, Saltstone Disposal Unit construction, etc. Thermal cameras on an unmanned aircraft system are used to help identify cracks/leaks in structures from vantage points not readily accessible by personnel. Virtual tours of different waste units are conducted with unmanned aircraft systems for Site groups and federal/state regulators to save costs and travel time. Additionally, advanced remote sensing technologies are used on unmanned aircraft systems at the Savannah River Site. Light Detection and Ranging uses laser pulses to measure distances to the Earth's surface or other targets to create highly detailed topographic maps that accurately portray terrain (e.g., elevation changes, slopes, and contours). Data collection with a Light Detection and Ranging unit mounted on an unmanned aircraft system is quick and efficient – large-area surveys are conducted in shorter time frames. Because Light Detection and Ranging can penetrate through foliage and vegetation to ground level, it is being used in conjunction with a watershed model to study the General Separations Area of the Site to determine stormwater flow volume and direction, monitor stream stability, and forecast river flow behavior. A hyperspectral camera captures a wide spectrum of electromagnetic wavelengths across numerous narrow bands, beyond what the human eye can see. It provides detailed spectral information about the objects or surfaces in an image, which can be used to identify and analyze materials based on their spectral signatures. A hyperspectral camera mounted on an unmanned aircraft system has been used at the Savannah River Site for non-destructive evaluation of concrete and concrete structures. Unmanned aircraft systems at the Savannah River Site are also used for the application of herbicide on identified rooftops. P-Reactor and R-Reactor are entombed nuclear reactors at the Savannah River Site. Unwanted vegetation is often present on these rooftops – over time roots can penetrate seams, cracks, and joints of the general roof and concrete caps, leading to water ingress and deterioration of the structural components. For time and cost efficiencies as well as in the interest of personnel safety, an unmanned aircraft is used to dispense herbicide on rooftop areas where vegetation is noticed to help alleviate the issues/hazards.

Lorier, Troy [Savannah River National Laboratory (↗

Natural gas liquefaction employing independent refrigerant path

A method of liquefying natural gas. The method comprises cooling a gaseous natural gas process stream with a refrigerant flowing in a path isolated from the natural gas process stream. The refrigerant may differ in composition from a composition of the natural gas process stream, and the refrigerant composition may be selected to enhance efficiency of the refrigerant path with regard to a specific composition of the natural gas process stream. The refrigeration path may be operated at pressures, temperatures and flow rates differing from those of the natural gas process stream. Other methods of liquefying natural gas are described. A natural gas liquefaction plant is also described.

03 NATURAL GAS↗

Particulate matter sensor

Microfabricated PM sensors measure concentrations of particulate matter (PM) in air. Some sensors improve the accuracy of measurements by accounting for the effect of ambient conditions (e.g., temperature or humidity) on mass-sensitive elements employed to determine a mass of the PM in a stream of air. Some sensors improve the accuracy of measurements by controlling humidity in the stream of air measured by mass-sensitive elements. Some sensors employ a plurality of mass-sensitive elements to extend the useful life of the PM sensor. Some sensors employ one or more mass-sensitive elements and heating elements to cause deposition and allow measurement of different sizes of PM. Some sensors can measure mass concentration of coarse PM in addition to fine PM in a stream of air. Some sensors control the flow rate of a stream of air measured by mass-sensitive elements. Some sensors include features to mitigate electromagnetic interference or electromagnetic signal loss.

Paprotny, Igor↗

System and method for controlling metal oxide gel particle size

Metal oxide gel particles, may be prepared with a desired particle size, by preparing a low-temperature aqueous metal nitrate solution containing hexamethylene tetramine as a feed solution; and causing the feed solution to flow through a first tube and exit the first tube as a first stream at a first flow rate, so as to contact a high-temperature nonaqueous drive fluid. The drive fluid flows through a second tube at a second flow rate. Shear between the first stream and the drive fluid breaks the first stream into particles of the metal nitrate solution, and decomposition of hexamethylene tetramine converts metal nitrate solution particles into metal oxide gel particles. A metal oxide gel particle size is measured optically, using a sensor device directed at a flow of metal oxide gel particles within the stream of drive fluid. The sensor device measures transmission of light absorbed by either the metal oxide gel particles or the drive fluid, so that transmission of light through the drive fluid changes for a period of time as a metal oxide gel particle passes the optical sensor. If a measured particle size is not about equal to a desired particle size, the particle size may be corrected by adjusting a ratio of the first flow rate to a total flow rate, where the total flow rate is the sum of the first and second flow rates.

Linneen, Nicholas N.↗

System and method for controlling metal oxide gel particle size

Metal oxide gel particles, may be prepared with a desired particle size, by preparing a low-temperature aqueous metal nitrate solution containing hexamethylene tetramine as a feed solution; and causing the feed solution to flow through a first tube and exit the first tube as a first stream at a first flow rate, so as to contact a high-temperature nonaqueous drive fluid. The drive fluid flows through a second tube at a second flow rate. Shear between the first stream and the drive fluid breaks the first stream into particles of the metal nitrate solution, and decomposition of hexamethylene tetramine converts metal nitrate solution particles into metal oxide gel particles. A metal oxide gel particle size is measured optically, using a sensor device directed at a flow of metal oxide gel particles within the stream of drive fluid. The sensor device measures transmission of light absorbed by either the metal oxide gel particles or the drive fluid, so that transmission of light through the drive fluid changes for a period of time as a metal oxide gel particle passes the optical sensor. If a measured particle size is not about equal to a desired particle size, the particle size may be corrected by adjusting a ratio of the first flow rate to a total flow rate, where the total flow rate is the sum of the first and second flow rates.

Linneen, Nicholas↗

Seasonal to Decadal Variability in Focused Groundwater and Contaminant Discharge along a Channelized Stream

Abstract Focused groundwater discharge to streams is problematic at contaminated sites because high fluxes can limit natural attenuation in the hyporheic zone. However, information on location, spatial evolution, and temporal persistence of springs in unlithified sediments over multiyear time scales is limited. We examine discharge at point (~1‐m) to reach (~300‐m) scales along a stream that intercepts trichloroethene and technetium‐99 plumes from a Superfund site. During 2011 to 2012, we seasonally monitored stream and spring flow and contaminant concentrations, along with probing streambed temperatures on a grid in winter and summer, building on prior monitoring during 1999 to 2002. Baseflow measured by both gauging and dye dilution generally increased with distance downstream, and stream and spring discharge varied seasonally, from minima in October to January to maxima in February to June. Thermal anomalies identified by probing occupied approximately 3% to 6% of the reach and typically coincided with visible springs or seeps. Locations of anomalies were similar to those identified in summer 2002, although some orifices disappeared and others emerged. Vertical groundwater fluxes calculated from probing tended to be less than net fluxes calculated from stream discharge, perhaps in part because the assumption of one‐dimensional, steady‐state flow in calculating point fluxes was simplistic. Maximum contaminant concentrations and fluxes decreased between 1999 to 2001 and 2011 to 2012 as a result of partial capture by an upgradient pump‐and‐treat system. Our findings confirm that springs in unlithified sediments can remain stationary within a few meters over decadal time scales, and seasonal variability in discharge can be greater than decadal variability.

Tripathi, Ganesh N.↗

ZFP Hardware Implementation

ZFP is a floating-point compression format gaining traction in high-performance computing applications. A software implementation has demonstrated the ability to reduce data movement across communication channels and to reduce the footprint of floating-point arrays in memory. Nevertheless, any benefit in performance is limited to the spare compute cycles available before reaching bandwidth limitations. A hardware implementation of ZFP has the potential to substantially improve HPC application performance. Hardware compression speedup over software alone on a single CPU core ranges from 15x for 1-D arrays to over 200x for 3-D arrays. The implementation of ZFP is sourced in SystemC to facilitate its evaluation in various architectures. The encode pipeline consists of several modules. Uncompressed blocks of floating-point numbers in IEEE format flow into the pipeline in a stream and a compressed bitstream flows out from the pipeline. The decode pipeline is the inverse of the encode pipeline. A modular design enables formats other than IEEE (such as posits) to be considered with minor adaptations. Best performance will be realized from the hardware ZFP unit when batches of blocks are processed at a time. The implementation supports 1-D, 2- D and 3-D blocks of floating-point numbers. The hardware implementation of ZFP has been validated with the software implementation of ZFP. C++ template parameters are used to specify the bit width of floating-point numbers and the array dimension of the encoder. A test bench program has been created with several test cases, some with continuous data that is ideal for ZFP, and others with extreme cases containing numbers near or at the maximum or minimum values supported by the number format.

Lloyd, GS↗

Systems and methods of making carbon nanotubes

A method of producing a carbon nanotube may include heating a convergent flow nozzle and a flow chamber of a carbon nanotube reactor, flowing a vaporized reactant stream through the nozzle and collecting a carbon nanotube product from an outlet of a heated flow chamber disposed downstream of the heated convergent flow nozzle. The vaporized reactant stream may include a carbon nanotube nucleation carbon source, a carbon nanotube growth carbon source, and a carbon nanotube catalyst precursor. The nozzle may have a nozzle contraction ratio of from 3:1 to 300:1.

Wang, Yuhuang↗

Out-of-plane curved fluidic oscillator

Various implementations include, an out-of-plane feedback-type fluidic oscillator. including a first portion, a second portion, a middle portion coupled between the first portion and the middle portion, and an axis of rotation. The middle portion includes a first side, a second side opposite and spaced apart from the first side, and a middle plane, an interaction chamber, a fluid supply inlet, an outlet nozzle, a first feedback a channel, and a second feedback channel. The first side is coupled to the first portion, and the second side is coupled to the second portion. The first side, the second side, and the middle plane extend circumferentially around the axis of rotation. The middle plane is disposed equally distanced from the first side and the second side. The fluid stream oscillates as it flows through the interaction chamber such that the fluid stream oscillates as the fluid stream exits the outlet nozzle.

Hossain, Mohammad Arif↗

Seasonal mixing from intermittent flow drives concentration-discharge behaviour in a stream affected by coal mine drainage

Abandoned mining operations continue to severely degrade many ecosystems worldwide by releasing acidic water and/or heavy metals into surface and groundwater. Contaminant concentrations in affected streams vary with discharge in patterns that reflect both geochemical reactions and variable mixing of contaminated and non-contaminated waters. However, controls on concentration-discharge (C-Q) patterns remain unclear, particularly for constituents that experience changing solubility across redox and pH gradients. Understanding the C-Q behaviour of contaminants aids in predicting both downstream transport and effects on aquatic life under variable flow. Here, we examined the C-Q behaviours of non-reactive (Na, K, Ca, Mg, Cl - ) and reactive (Fe, Mn, Al, H + , SO 4 2- ) solutes in a stream contaminated with acid mine drainage in northeastern Ohio, USA. Concentration-discharge patterns at the watershed outlet primarily reflected mixing of contaminated baseflow with intermittent inputs of high pH water draining from a passive limestone treatment system into the stream. The treatment system acted as an ephemeral tributary that mitigated contamination in the stream by diluting solutes, raising pH, and driving metal precipitation, but only when flow was present during wet seasons. Consequently, AMD-derived reactive solutes (H + , Fe, Mn, Al) decreased with increasing stream discharge while relatively conservative solutes (e.g., Ca, Mg, K, Na) decreased only slightly or were chemostatic. This study highlights both the unique C-Q patterns of reactive solutes when compared to those of non-reactive solutes and the potential for intermittent streams to control C-Q behaviour in headwater catchments.

58 GEOSCIENCES↗

Millisecond timescale reactions observed via X-ray spectroscopy in a 3D microfabricated fused silica mixer

Determination of electronic structures during chemical reactions remains challenging in studies which involve reactions in the millisecond timescale, toxic chemicals, and/or anaerobic conditions. Here, a three-dimensionally (3D) microfabricated microfluidic mixer platform that is compatible with time-resolved X-ray absorption and emission spectroscopy (XAS and XES, respectively) is presented. This platform, to initiate reactions and study their progression, mixes a high flow rate (0.50–1.5 ml min –1 ) sheath stream with a low-flow-rate (5–90 µl min –1 ) sample stream within a monolithic fused silica chip. The chip geometry enables hydro­dynamic focusing of the sample stream in 3D and sample widths as small as 5 µm. The chip is also connected to a polyimide capillary downstream to enable sample stream deceleration, expansion, and X-ray detection. In this capillary, sample widths of 50 µm are demonstrated. Further, convection–diffusion-reaction models of the mixer are presented. The models are experimentally validated using confocal epifluorescence microscopy and XAS/XES measurements of a ferricyanide and ascorbic acid reaction. The models additionally enable prediction of the residence time and residence time uncertainty of reactive species as well as mixing times. Residence times (from initiation of mixing to the point of X-ray detection) during sample stream expansion as small as 2.1 ± 0.3 ms are also demonstrated. Importantly, an exploration of the mixer operational space reveals a theoretical minimum mixing time of 0.91 ms. The proposed platform is applicable to the determination of the electronic structure of conventionally inaccessible reaction intermediates.

3D microfabrication↗

Hydrologic response of artificially drained agricultural watersheds: insights from high-resolution integrated surface/subsurface simulations

Artificial drainage systems comprising subsurface networks of perforated pipes (tile drains) and engineered surface ditches are widely used to remove excess water from poorly drained agricultural regions. Artificial drainage lowers the water table by design but also has inadvertent effects on the watershed-scale hydrologic response with important implications for flood risk and nutrient exports. We investigated the effects of tile drains on watershed-scale hydrologic response in the Portage River, OH, Watershed using a high-resolution physically based integrated surface/subsurface hydrology model with recently developed capabilities to represent artificial drainage. Tile drains were found to enhance streamflow during times of low flow, generally consistent with previous studies. Streamflow flashiness was found to have a non-monotonic dependence on tile spacing with a minimum at intermediate spacings (∼50 m). Flashiness and the event hydrographs for small tile spacing were similar to the situation with no tiles, but flow paths from farm to stream were very different for those two end member cases, emphasizing the limitations of the stream hydrograph in characterizing hydrologic response. For typical tile spacings, peak flow can either be enhanced or attenuated by the presence of tiles, depending on the size of the event and the antecedent meteorological conditions. Tiles enhance peak flow when the event is below a threshold of ∼25 mm or when events arrive in dry conditions. Peak flow is reduced by tiles when events are large and arrive in conditions that are not overly dry. The dependence on event size and antecedent conditions is explained by differences in available storage and flow paths to the streams. These results provide additional insights into how tile drainage modulates event-scale hydrologic response, an important control on flood generation mechanisms and nutrient exports.

agricultural watershed↗

A Thermodynamic Model Toward the Comprehension of Ferrous Burden Softening and Melting Using FactSage Macro-Processing

The softening and melting properties of iron-bearing materials play a decisive role in the formation of the cohesive zone, which greatly affects blast furnace gas flow distribution and heat-transfer efficiency. To improve the understanding regarding the evolution of condensed phases during reduction, softening, and melting, a thermodynamic model has been developed using FactSage™ thermodynamic software and macro-processing. The model was constructed using a series of equilibrium stages and splitters to determine flow directions of streams and to consider kinetic inhibitions. For all iron-bearing materials studied, the methodology proposed for modeling was capable of obtaining reduction degrees in very good agreement to its experimental data. The evolution of solid phases was qualitatively comparable to the available literature, with Fayalite, Kirschsteinite, Melilite, and FeO as the main solid phases in equilibrium before slag formation. The comparison between the profiles of the calculated slag mass fraction and the experimental pressure drop showed a close relation between these properties. Moreover, the level of heterogeneity of each raw material may play a significant role in the interpretation of its results.

36 MATERIALS SCIENCE↗

Quantitatively Monitoring Bubble-Flow at a Seep Site Offshore Oregon: Field Trials and Methodological Advances for Parallel Optical and Hydroacoustical Measurements

Two lander-based devices, the Bubble-Box and GasQuant-II, were used to investigate the spatial and temporal variability and total gas flow rates of a seep area offshore Oregon, United States. The Bubble-Box is a stereo camera–equipped lander that records bubbles inside a rising corridor with 80 Hz, allowing for automated image analyses of bubble size distributions and rising speeds. GasQuant is a hydroacoustic lander using a horizontally oriented multibeam swath to record the backscatter intensity of bubble streams passing the swath plain. The experimental set up at the Astoria Canyon site at a water depth of about 500 m aimed at calibrating the hydroacoustic GasQuant data with the visual Bubble-Box data for a spatial and temporal flow rate quantification of the site. For about 90 h in total, both systems were deployed simultaneously and pressure and temperature data were recorded using a CTD as well. Detailed image analyses show a Gaussian-like bubble size distribution of bubbles with a radius of 0.6–6 mm (mean 2.5 mm, std. dev. 0.25 mm); this is very similar to other measurements reported in the literature. Rising speeds ranged from 15 to 37 cm/s between 1- and 5-mm bubble sizes and are thus, in parts, slightly faster than reported elsewhere. Bubble sizes and calculated flow rates are rather constant over time at the two monitored bubble streams. Flow rates of these individual bubble streams are in the range of 544–1,278 mm 3 /s. One Bubble-Box data set was used to calibrate the acoustic backscatter response of the GasQuant data, enabling us to calculate a flow rate of the ensonified seep area (~1,700 m 2 ) that ranged from 4.98 to 8.33 L/min (5.38 × 10 6 to 9.01 × 10 6 CH 4 mol/year). Such flow rates are common for seep areas of similar size, and as such, this location is classified as a normally active seep area. For deriving these acoustically based flow rates, the detailed data pre-processing considered echogram gridding methods of the swath data and bubble responses at the respective water depth. The described method uses the inverse gas flow quantification approach and gives an in-depth example of the benefits of using acoustic and optical methods in tandem.

54 ENVIRONMENTAL SCIENCES↗

Hydrothermal Liquefaction and Upgrading of Wastewater-Grown Microalgae: 2021 State of Technology

The fiscal year (FY) 2021 State of Technology (SOT) Assessment for the hydrothermal liquefaction (HTL) of wastewater (WW)-grown microalgae and biocrude upgrading system was completed and reported here. An industrial partner, Gross-Wen Technologies (GWT), provided algae feedstock cultivated on a revolving algal biofilm (RAB) system by using the primary effluent from a water resource recovery facility (WRRF). This provided algae was tested at PNNL for HTL processing. The experimental results provided the major design basis of the HTL process of the SOT baseline case. The primary effluent of the Metropolitan Water Reclamation District (MWRD) of Greater Chicago was assumed to be the nutrients source for algae growth and the algae yield data per gallon wastewater provided by GWT were used to estimate the total algae production rate and thus the HTL conversion plant scale. Considering different cultivation technologies and wastewater streams with different flow rates and nutrients contents can be used to produce algae, this SOT assessment just provided an example case study for WW-grown algae based HTL conversion to fuels systems. A preliminary economic analysis was developed based on process simulation results. Sensitivity analysis was implemented to evaluate cost impacts of plant scales, potential cost improvements and other key factors.

54 ENVIRONMENTAL SCIENCES↗

StrmtbFlow Fortran Program, Version 2

<span>This zip file contains files storing Fortran source code, compiled files, an executable file for Windows computers, and example input and output files for StmtbFlow. StrmtbFlow is a Fortran program that solves the multiphase flow equations within stream tubes and can be used to estimate the oil produced and CO2 stored from the application of CO2 EOR to an oil field. StrmtbFlow and StrmtbGen comprise the FE/NETL CO2 Prophet Model, which is a streamline/stream tube reservoir simulator for modeling CO2 EOR. StrmtbFlow's user&rsquo;s manual as well as StrmtbGen and its user's manual and a report on the mathematical basis for the FE/NETL CO2 Prophet Model are available on NETL's website under the Collection Name: FE/NETL CO2 Prophet Model.</span><span>&nbsp;</span>

Morgan, David↗