Search NASA⌕ Search

SEARCH · Search NASA

Results for “superconducting resonators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Cosmic Microwave Background Polarization Detector with High Efficiency, Broad Bandwidth, and Highly Symmetric Coupling to Transition Edge Sensor Bolometers

Four probe antennas transfer signals from waveguide to microstrip lines. The probes not only provide broadband impedance matching, but also thermally isolate waveguide and detector. In addition, we developed a new photonic waveguide choke joint design, with four-fold symmetry, to suppress power leakage at the interface. We have developed facilities to test superconducting circuit elements using a cryogenic microwave probe station, and more complete systems in waveguide. We used the ring resonator shown below to measure a dielectric loss tangent < 7x10(exp -4) over 10 - 45 GHz. We have combined component simulations to predict the overall coupling from waveguide modes to bolometers. The result below shows the planar circuit and waveguide interface can utilize the high beam symmetry of HE11 circular feedhorns with > 99% coupling efficiency over 30% fractional bandwidth.

Wollack, E.↗

Josephson frequency meter for millimeter and submillimeter wavelengths

Frequency measurements of electromagnetic oscillations of millimeter and submillimeter wavebands with frequency growth due to a number of reasons become more and more difficult. First, these frequencies are considered to be cutoffs for semiconductor converting devices and one has to use optical measurement methods instead of traditional ones with frequency transfer. Second, resonance measurement methods are characterized by using relatively narrow bands and optical ones are limited in frequency and time resolution due to the limited range and velocity of movement of their mechanical elements as well as the efficiency of these optical techniques decrease with the increase of wavelength due to diffraction losses. That requires a priori information on the radiation frequency band of the source involved. Method of measuring frequency of harmonic microwave signals in millimeter and submillimeter wavebands based on the ac Josephson effect in superconducting contacts is devoid of all the above drawbacks. This approach offers a number of major advantages over the more traditional measurement methods, that is one based on frequency conversion, resonance and interferometric techniques. It can be characterized by high potential accuracy, wide range of frequencies measured, prompt measurement and the opportunity to obtain a panoramic display of the results as well as full automation of the measuring process.

Anischenko, S. E.↗

Performance of a K-band superconducting annular ring antenna

Superconducting annular ring antennas operating in the TM12 mode at 21 GHz are designed and fabricated on a lanthanum aluminate substrate using a YBCO high-temperature superconducting thin film. The efficiencies and far-field antenna patterns are measured and compared with an identical antenna patterned with silver. The resonant frequencies and experimental far-field patterns agree well with published models, and efficiency measurements show a maximum improvement of 6 percent at 20 K in the efficiency of the HTS antenna when compared to the silver ring at the same temperature.

Richard, M. A.↗

Tunable Microwave Components for Ku- and K-Band Satellite Communications

The use of conductor/ferroelectric/dielectric thin film multilayer structures for frequency and phase agile components at frequencies at and above the Ku-band will be discussed. Among these components are edge coupled filters, microstripline ring resonators, and phase shifters. These structures were implemented using SrTiO3 (STO) ferroelectric thin films, with gold or YBa2Cu3O7-d (YBCO) high temperature superconducting (HTS) microstrip fines deposited by laser ablation on LaAlO3 (LAO) substrates. The performance of these structures in terms of tunability, operating temperature, frequency, and dc bias will be presented. Because of their small size, light weight, and low loss, these tunable microwave components are being studied very intensely at NASA as well as the commercial communication industry. An assessment of the progress made so far, and the issues yet to be solved for the successful integration of these components into the aforementioned communication systems will be presented.

Miranada, F. A.↗

Open-Access, Low-Magnetic-Field MRI System for Lung Research

An open-access magnetic resonance imaging (MRI) system is being developed for use in research on orientational/gravitational effects on lung physiology and function. The open-access geometry enables study of human subjects in diverse orientations. This system operates at a magnetic flux density, considerably smaller than the flux densities of typical other MRI systems, that can be generated by resistive electromagnet coils (instead of the more-expensive superconducting coils of the other systems). The human subject inhales air containing He-3 or Xe-129 atoms, the nuclear spins of which have been polarized by use of a laser beam to obtain a magnetic resonance that enables high-resolution gas space imaging at the low applied magnetic field. The system includes a bi-planar, constant-current, four-coil electromagnet assembly and associated electronic circuitry to apply a static magnetic field of 6.5 mT throughout the lung volume; planar coils and associated circuitry to apply a pulsed magnetic-field-gradient for each spatial dimension; a single, detachable radio-frequency coil and associated circuitry for inducing and detecting MRI signals; a table for supporting a horizontal subject; and electromagnetic shielding surrounding the electromagnet coils.

Mair, Ross W.↗

Microwave integrated circuit for Josephson voltage standards

A microwave integrated circuit comprised of one or more Josephson junctions and short sections of microstrip or stripline transmission line is fabricated from thin layers of superconducting metal on a dielectric substrate. The short sections of transmission are combined to form the elements of the circuit and particularly, two microwave resonators. The Josephson junctions are located between the resonators and the impedance of the Josephson junctions forms part of the circuitry that couples the two resonators. The microwave integrated circuit has an application in Josephson voltage standards. In this application, the device is asymmetrically driven at a selected frequency (approximately equal to the resonance frequency of the resonators), and a d.c. bias is applied to the junction. By observing the current voltage characteristic of the junction, a precise voltage, proportional to the frequency of the microwave drive signal, is obtained.

Holdeman, L. B.↗

The Millimeter-Wave Properties of Superconducting Microstrip Lines

We have developed a novel technique for making high quality measurements of the millimeter-wave properties of superconducting thin-film microstrip transmission lines. Our experimental technique currently covers the 75-100 GHz band. The method is based on standing wave resonances in an open ended transmission line. We obtain information on the phase velocity and loss of the microstrip. Our data for Nb/SiO/Nb lines, taken at 4.2 K and 1.6 K, can be explained by a single set of physical parameters. Our preliminary conclusion is that the loss is dominated by the SiO dielectric, with a temperature-independent loss tangent of 5.3 +/- 0.5 x 10(exp -3) for our samples.

Vayonakis, A.↗

In-situ sputtering of YBCO films for microwave applications

RF magnetron sputtering from a single YBCO target onto a heated substrate (700 C) was used to obtain c-axis-oriented 1-2-3 films that are superconducting without a subsequent annealing or oxygenation step, with Tc(R = 0) as high as 88 K on MgO and LaAlO3 substrates. This process uses an 8-in-diameter target in the sputter-up configuration, with a central grounded shield to eliminate negative ion bombardment. It can reproducibly and uniformly cover substrates as large as 3-in across at rates exceeding 1 A/s. Maintaining film composition very close to stoichiometry is essential for obtaining films with good superconducting properties and surface morphology. Optimum films have critical currents of 1 MA/sq cm at 77 K. Measurements of microwave surface resistance based on a stripline resonator indicate low surface resistance for unpatterned YBCO ground planes, but excess loss and a strong power dependence in a patterned center strip.

Ballentine, P. H.↗

Infrared-Bolometer Arrays with Reflective Backshorts

Integrated circuits that incorporate square arrays of superconducting-transition- edge bolometers with optically reflective backshorts are being developed for use in image sensors in the spectral range from far infrared to millimeter wavelengths. To maximize the optical efficiency (and, thus, sensitivity) of such a sensor at a specific wavelength, resonant optical structures are created by placing the backshorts at a quarter wavelength behind the bolometer plane. The bolometer and backshort arrays are fabricated separately, then integrated to form a single unit denoted a backshort-under-grid (BUG) bolometer array. In a subsequent fabrication step, the BUG bolometer array is connected, by use of single-sided indium bump bonding, to a readout device that comprises mostly a superconducting quantum interference device (SQUID) multiplexer circuit. The resulting sensor unit comprising the BUG bolometer array and the readout device is operated at a temperature below 1 K. The concept of increasing optical efficiency by use of backshorts at a quarter wavelength behind the bolometers is not new. Instead, the novelty of the present development lies mainly in several features of the design of the BUG bolometer array and the fabrication sequence used to implement the design. Prior to joining with the backshort array, the bolometer array comprises, more specifically, a square grid of free-standing molybdenum/gold superconducting-transition-edge bolometer elements on a 1.4- m-thick top layer of silicon that is part of a silicon support frame made from a silicon-on-insulator wafer. The backshort array is fabricated separately as a frame structure that includes support beams and contains a correspond - ing grid of optically reflective patches on a single-crystal silicon substrate. The process used to fabricate the bolometer array includes standard patterning and etching steps that result in the formation of deep notches in the silicon support frame. These notches are designed to interlock with the support beams on the backshort-array structure to provide structural support and precise relative positioning. The backshort-array structure is inserted in the silicon support frame behind the bolometer array, and the notches in the frame serve to receive the support beams of the backshort-array structure and thus determine the distance between the backshort and bolometer planes. The depth of the notches and, thus, the distance between the backshort and bolometer planes, can be tailored to a value between 25 to 300 m adjusting only a few process steps. The backshort array is designed so as not to interfere with the placement of indium bumps for subsequent indium bump-bonding to the multiplexing readout circuitry

Miller, Timothy M.↗

Microwave properties and characterization of co-evaporated BSCCO thin films

An extensive characterization of Bi-Sr-Ca-Cu-O (BSCCO) thin films deposited by co-evaporation on LaAlO3 and SrTiO3 substrates was performed. The films had a T(sub c) (R = O) of approximately 78 K, and were predominantly c-axis oriented, with critical current densities (J(sub c)) at 4.5 K of 1.6 x 10(exp 6) and 1.1 x 10(exp 6) A cm(sup -2), for the samples on SrTiO3 and LaAlO3, respectively. The microwave properties of the films were examined by three techniques. The complex conductivity sigma(sub *) = sigma(sub 1) - j(sigma(sub 2)) and the magnetic penetration depth (A) were measured by power transmission at 30.6 GHz; the surface resistance (R(sub s)) was measured using a cavity resonator at 58.9 GHz, and the transmission line losses were determined by measuring the quality factor (Q) of a linear microstrip resonator at 10.4 and 20.2 GHz. The complex conductivity for the film on LaAlO3 was determined to be (2.0-j10) x 10(exp 5) S/m at 77 K. It was observed that in the superconducting state sigma(sub 1) deviates from both the Bardeen-Cooper-Schrieffer (BCS) theory and the two-fluid model. Values of lambda were found to be approximately 2.0 and 1.1 microns at 77 K and 20 K respectively, and were obtained for the film on LaAlO3. The value of lambda at 20 K was approximately three times larger than that of BSCCO single crystals. R(sub s) values of 865 and 1391 mOmega were obtained for the films on SrTiO3 and LaAlO3, respectively, at 77 K and 58.9 GHz. Unloaded Q factors at 20 K of approximately 1100 and 800 at 10.4 and 20.2 GHz respectively, were measured for the BSCCO resonator. Unloaded Q values of 290 and 405 at 20 K were obtained at 10.4 GHz and 20.2 GHz respectively, for an all gold (Au) resonator.

Miranda, F. A.↗

Investigations of Relatively Easy To Construct Antennas With Efficiency in Receiving Schumann Resonances: Preparations for a Miniaturized Reconfigurable ELF Receiver

Relatively little is known about the cavity between the Earth and the ionosphere, which opens opportunities for technological advances and unique ideas. One effective means to study this cavity is with extremely low frequency (ELF) antennas. Possible applications of these antennas are global weather prediction, earthquake prediction, planetary exploration, communication, wireless transmission of power, or even a free energy source. The superconducting quantum interference device SQUID) and the coil antenna are the two most acceptable receivers discovered for picking up ELF magnetic fields. Both antennas have the potential for size reduction, allowing them to be portable enough for access to space and even for personal ware. With improvements of these antennas and signal processing, insightful analysis of Schumann resonance (SR) can give the science community a band of radio frequency (RF) signals for improving life here on Earth and exploring beyond.

Farmer, Brian W.↗

In vivo nuclear magnetic resonance imaging

During the past year the Woodlands Baylor Magnetic Resonance Imaging (MRI) facility became fully operational. A detailed description of this facility is given. One significant instrument addition this year was the 100 MHz, 40cm bore superconducting imaging spectrometer. This instrument gives researchers the capability to acquire high energy phosphate spectra. This will be used to investigate ATP, phosphocreatinine and inorganic phosphate changes in normal and atrophied muscle before, during and after exercise. An exercise device for use within the bore of the imaging magnet is under design/construction. The results of a study of T sub 1 and T sub 2 changes in atrophied muscle in animals and human subjects are given. The imaging and analysis of the lower leg of 15 research subjects before and after 5 weeks of complete bedrest was completed. A compilation of these results are attached.

Leblanc, A.↗

Reducing Field Distortion in Magnetic Resonance Imaging

A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

Eom, Byeong Ho↗

Integrated Cryogenic Satellite Communications Cross-Link Receiver Experiment

An experiment has been devised which will validate, in space, a miniature, high-performance receiver. The receiver blends three complementary technologies; high temperature superconductivity (HTS), pseudomorphic high electron mobility transistor (PHEMT) monolithic microwave integrated circuits (MMIC), and a miniature pulse tube cryogenic cooler. Specifically, an HTS band pass filter, InP MMIC low noise amplifier, HTS-sapphire resonator stabilized local oscillator (LO), and a miniature pulse tube cooler will be integrated into a complete 20 GHz receiver downconverter. This cooled downconverter will be interfaced with customized signal processing electronics and integrated onto the space shuttle's 'HitchHiker' carrier. A pseudorandom data sequence will be transmitted to the receiver, which is in low Earth orbit (LEO), via the Advanced Communication Technology Satellite (ACTS) on a 20 GHz carrier. The modulation format is QPSK and the data rate is 2.048 Mbps. The bit error rate (BER) will be measured in situ. The receiver is also equipped with a radiometer mode so that experiment success is not totally contingent upon the BER measurement. In this mode, the receiver uses the Earth and deep space as a hot and cold calibration source, respectively. The experiment closely simulates an actual cross-link scenario. Since the receiver performance depends on channel conditions, its true characteristics would be masked in a terrestrial measurement by atmospheric absorption and background radiation. Furthermore, the receiver's performance depends on its physical temperature, which is a sensitive function of platform environment, thermal design, and cryocooler performance. This empirical data is important for building confidence in the technology.

Romanofsky, R. R.↗

Characterization of superconducting magnetic bearings (dynamic stiffness and damping coefficient in axial direction)

High T(sub c) superconductor as a stator and permanent magnets for a rotor were assembled into a superconducting magnetic bearing. The dynamic stiffness and the damping coefficient of the superconducting magnetic bearing in axial direction were measured. The dynamic stiffness depended on an axial gap between superconductor and permanent magnet. The superconducting magnetic bearings are advantageous for a passive bearing, because they have a vibration damping effect that a permanent magnet bearing does not have. The tendency of its vibration damping coefficient indicated an increase as the resonant frequency increased.

Takahata, Ryoichi↗

A lead-on-sapphire superconducting cavity of superior quality

A cavity consisting of a superconducting lead film on a sapphire substrate has been fabricated to obtain the enhanced frequency stability possible with this configuration. The cavity exhibits a quality value Q exceeding 2 x 10 to the 9th in its TE011 mode with a resonant frequency of 2.689 GHz. Methods of fabrication and testing of the cavity are presented. Since the interface between the film and substrate is exposed ot the full value of the resonant magnetic field, the present experiment is the most sensitive test to date for enhanced losses at the interface itself. No evidence of such losses is used. In fact, the measured values of the surface resistance match very well predictions for RF losses based on the BCS theory.

Thakoor, S.↗

An ultraviolet gas-loaded free-electron laser

By loading the wiggler cavity of an FEL with hydrogen gas, it is possible to tune the FEL to below 130 nm, just above the electronic resonance of molecular hydrogen. The change in wavelength results from the refractive index of the gas, which alters the phase velocity of the wave and so modifies the synchronism condition. Using the parameters of the wiggler on the beamline of the Stanford Superconducting Accelerataor, this FEL can be tuned from 500 to 130 nm with a pressure ranging from 0 to 55 torr. The calculated electronic gain varies between 5.6 and 11 percent over this wavelength interval, comparable to the gain in vacuum.

Reid, Max B.↗