Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchrotron beamline”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

High-energy synchrotron X-ray multimodal computed tomography: enabling multiscale materials characterization at NSLS-II

We report the commissioning of a multimodal computed tomography experimental setup at the 28-ID-2 (XPD) beamline of the National Synchrotron Light Source II. This high-energy (>60 keV) resource features a tunable X-ray beam size ranging from several millimetres to a few micrometres and enables comprehensive characterization of high-Z materials—an essential capability for nuclear and advanced materials research. It provides four complementary computed tomography modalities: X-ray absorption, X-ray fluorescence, X-ray diffraction, and pair distribution function tomography. A case study using a custom-made heterogeneous sample demonstrates these abilities to simultaneously capture atomic, elemental, and morphological information. This unique combination of imaging, structural, and chemical sensitive methods provides a holistic approach to study complex materials with amorphous and crystalline systems across multiple length scales.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New high-throughput endstation to accelerate the experimental optimization pipeline for synchrotron X-ray footprinting

Synchrotron X-ray footprinting (XF) is a growing structural biology technique that leverages radiation-induced chemical modifications via X-ray radiolysis of water to produce hydroxyl radicals that probe changes in macromolecular structure and dynamics in solution states of interest. The X-ray Footprinting of Biological Materials (XFP) beamline at the National Synchrotron Light Source II provides the structural biology community with access to instrumentation and expert support in the XF method, and is also a platform for development of new technological capabilities in this field. Hee, the design and implementation of a new high-throughput endstation device based around use of a 96-well PCR plate form factor and supporting diagnostic instrumentation for synchrotron XF is described. This development enables a pipeline for rapid comprehensive screening of the influence of sample chemistry on hydroxyl radical dose using a convenient fluorescent assay, illustrated here with a study of 26 organic compounds. The new high-throughput endstation device and sample evaluation pipeline now available at the XFP beamline provide the worldwide structural biology community with a robust resource for carrying out well optimized synchrotron XF studies of challenging biological systems with complex sample compositions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Memory and CPU efficient coherent mode decomposition of partially coherent synchrotron radiation with subtraction of common quadratic phase terms

Application examples of a memory and CPU efficient coherent mode decomposition (CMD) method for wave-optics based simulation of the partially coherent undulator radiation propagation through a hard X-ray beamline in a 3rd generation synchrotron radiation source are presented. The high efficiency of the method is achieved thanks to the analytical treatment of the common quadratic phase terms that are developed in the phase of cross-spectral density (CSD) of partially coherent radiation at a distance from source. This treatment allows for a considerable, several orders of magnitude, reduction of the 4D CSD mesh density (and the memory occupied by the CSD) required for ensuring sufficient accuracies of wavefront propagation simulations with the modes produced by the CMD at a beamline entrance. This method, implemented in the “Synchrotron Radiation Workshop” open-source software, dramatically increases the feasibility of the CMD of 4D CSD for producing 2D coherent modes for a large variety of applications at storage rings and other types of radiation sources.

36 MATERIALS SCIENCE↗

Milestone 1.2.15: Feasibility of In Situ Accelerated Aluminum Coupon Radiolysis by Synchrotron X-Rays

Extended dry storage of aluminum-clad spent nuclear fuel (ASNF) requires an assessment of the radiolytic generation of molecular hydrogen gas (H2) from the ASNF’s corrosion layers. H2 accumulation can potentially lead to storage canister embrittlement/rupture and the accumulation of flammable gas mixtures in accident scenarios. To date, computational models have been developed for the prediction of radiolytic H2 generation from samples exposed to lower absorbed dose regimes (up to ~3 MGy). However, greater accuracy is needed for higher absorbed doses (> 25 MGy) where the concentration of H2 ultimately reaches a steady-state. Data in this area is limited due to the amount of time taken (months) to accumulate such high gamma doses. Furthermore, a recent study observed radiation-induced damage to the surface of pre-corroded aluminum alloy coupons at high absorbed gamma doses. Despite this observation and its implications, there is currently no computational connection between the radiolytic formation of H2 and changes in the composition and morphology of the cladding’s corrosion layers with absorbed dose. To develop a better understanding of the processes and effects described above, the present study aimed to evaluate the feasibility of leveraging synchrotron x-ray capabilities for coupled accelerated irradiation and in situ surface characterization of ASNF alloys. To that end, National Synchrotron Light Source II (NSLS-II) beamtime was secured and a series of aluminum alloy 1100 (AA1100) wires, prepared under a variety of conditions, were interrogated using ex situ x-ray diffraction (XRD) and scanning electron microscopy (SEM) techniques at Idaho National Laboratory (INL) and ex situ and in situ XRD capabilities at the NSLS-II x-ray powder diffraction (XPD) beamline. Results indicated that performing synchrotron XRD using the available XPD beamline configuration can provide sufficient radiation dose but cannot discern changes in the composition and morphology of sample corrosion layers. Additionally, ex situ XRD and SEM data from Idaho National Laboratory (INL) indicated that the pre-corrosion of AA1100 wires did not generate an appreciably thick corrosion layer, as compared with previous aluminum coupon studies. These thinner surface corrosion layers were not sufficient for detection by both ex situ and in situ synchrotron XRD, specifically under consideration of the NSLS-II XPD beamline’s configuration primarily capturing information from the sample’s bulk material, i.e., aluminum metal. In summary, the use of the NSLS-II XPD beamline for promoting accelerated radiolysis and in situ surface characterization is not appropriate for this program’s goals.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Machine learning enabling high-throughput and remote operations at large-scale user facilities

Imaging, scattering, and spectroscopy are fundamental in understanding and discovering new functional materials. Contemporary innovations in automation and experimental techniques have led to these measurements being performed much faster and with higher resolution, thus producing vast amounts of data for analysis. These innovations are particularly pronounced at user facilities and synchrotron light sources. Machine learning (ML) methods are regularly developed to process and interpret large datasets in real-time with measurements. However, there remain conceptual barriers to entry for the facility general user community, whom often lack expertise in ML, and technical barriers for deploying ML models. Herein, we demonstrate a variety of archetypal ML models for on-the-fly analysis at multiple beamlines at the National Synchrotron Light Source II (NSLS-II). We describe these examples instructively, with a focus on integrating the models into existing experimental workflows, such that the reader can easily include their own ML techniques into experiments at NSLS-II or facilities with a common infrastructure. The framework presented here shows how with little effort, diverse ML models operate in conjunction with feedback loops via integration into the existing Bluesky Suite for experimental orchestration and data management.

36 MATERIALS SCIENCE↗

Effects of X-rays on Perovskite Solar Cells

Synchrotron micro- and nanoprobe beamlines have demonstrated great potential to advance photovoltaic devices. Most importantly, their small X-ray spot size has enabled the direct correlation of electrical performance with elemental composition at subgrain resolution for a variety of polycrystalline solar cells. Whereas the bulk of most inorganic semiconductors is stable under the high X-ray flux of focused X-ray beams, semiconductors with organic components are prone to a variety of degradation mechanisms. This is particularly critical to evaluate for the emerging organometal halide perovskite solar cells. In this study, we investigate the effects of hard X-rays on the nanoscale performance and elemental distribution of these solar cells. We show that their composition does not change during common operando and in situ measurements at synchrotron nanoprobes. However, we found a significant X-ray-induced electronic degradation of solar cells with methylammonium lead iodide absorbers. Time- and dose-dependent measurements unveiled two characteristic degradation time constants on the order of 12 and 200 s that are independent of the X-ray flux. On the basis of heat and dose simulations, we attribute the fast decay to the dose-driven creation of recombination centers, while the slow decay is compatible with the observation of compositional changes. Finally, we detail how degradation-induced measurement artifacts can be outrun and showcase the high correlation of the X-ray-beam-induced current with the iodine and lead distribution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Specimen-displacement correction for powder X-ray diffraction in Debye–Scherrer geometry with a flat area detector

The effect of small changes in the specimen-to-detector distance on the unit-cell parameters is examined for synchrotron powder diffraction in Debye–Scherrer (transmission) geometry with a flat area detector. An analytical correction equation is proposed to fix the shift in 2θ values due to specimen capillary displacement. This equation does not require the use of an internal reference material, is applied during the Rietveld refinement step, and is analogous to the specimen-displacement correction equations for Bragg–Brentano and curved-detector Debye–Scherrer geometry experiments, but has a different functional form. The 2θ correction equation is compared with another specimen-displacement correction based on the use of an internal reference material in which new integration and calibration parameters of area-detector images are determined. Example data sets showing the effect of a 3.3 mm specimen displacement on the unit-cell parameters for 25°C CeO 2 , including both types of displacement correction, are described. These experiments were performed at powder X-ray diffraction beamlines at the National Synchrotron Light Source II at Brookhaven National Laboratory and the Advanced Photon Source at Argonne National Laboratory.

36 MATERIALS SCIENCE↗

Adaptive X-ray imaging with reinforcement learning

X-ray imaging is a powerful technique to scan samples in a variety of contexts including biological, environmental and materials science, but commonly requires a synchrotron light source to produce X-rays at sufficient intensity. As these facilities are expensive to operate, the available beam time is limited and always in high demand. Particularly if the illuminated samples are sparse, standard raster scanning methods can be time-consuming, with a majority of that time being spent on areas of the image that carry little information. To increase the efficiency and maximize the information gain for a given time budget, we split the scanning process into a series of steps where previous measurements are used to inform the decision making and adapt the exposure distribution at later stages of the sequence. We formulate this task as a reinforcement learning problem where the goal is to produce a sequence of exposure maps that maximize a predefined scalar metric. We demonstrate the potential of this approach in simulations where the adaptive illumination can accelerate the measurement process by up to an order of magnitude compared with standard raster scanning. Finally, we present the first results from deploying the trained agents on an X-ray fluorescence beamline at the Stanford Synchrotron Radiation Lightsource.

Reinforcement Learning↗

Magnetic Designs of New First Target Beamline Magnets for the ORNL SNS Upgrade

The Spallation Neutron Source (SNS) at ORNL currently is being upgraded from 1.0 GeV to 1.3 GeV. Several water-cooled magnets should be upgraded to transport 30% of higher beam energy. New chicane, injection/extraction septum, and Lambertson magnets were designed. Designing the magnets was a challenging task because the new magnets required good combined integrated field quality and needed to occupy the old magnets space but with about 20% greater integrated magnetic field. Additional strong requirements applied to the magnets fringe field do not disturb the circulating beam. The special field profiles had to be provided in foil areas between magnets. The analysis described here was based on OPERA3D simulations. A special technique was used for analyzing the integrated field harmonics. Initially, the particle track was simulated, and integrated field components were calculated along this track for the reference radius, which were used for the harmonics analysis. In addition, 3D field maps were provided for beam optics simulations. The final beamline analysis confirmed good beam transmission and low losses.

3d field maps↗

Radiation furnace for synchrotron dark-field x-ray microscopy experiments

We present a multi-purpose radiation furnace designed for x-ray experiments at synchrotrons. The furnace is optimized specifically for dark-field x-ray microscopy (DFXM) of crystalline materials at beamline ID06 of the European Synchrotron Radiation Facility. The furnace can reach temperatures above 1200 °C with a thermal stability better than 10 °C, with heating and cooling rates up to 30 K/s. The non-contact heating design enables samples to be heated either in air or in a controlled atmosphere contained within a capillary tube. The temperature was calibrated via the thermal expansion of an α-iron grain. Temperature profiles in the y and z axes were measured by scanning a thermocouple through the focal spot of the radiation furnace. In the current configuration of the beamline, this furnace can be used for DFXM, near-field x-ray topography, bright-field x-ray nanotomography, high-resolution reciprocal space mapping, and limited powder diffraction experiments. As a first application, we present a DFXM case study on isothermal heating of a commercially pure single crystal of aluminum.

Yildirim, C. (ORCID:0000000249690685)↗

Mechanical design of a parallel flexure-based RADSI instrument for curved x-ray mirror metrology

Modern synchrotron x-ray beamlines demand reflective optics with higher surface profile accuracy to achieve diffraction-limited focusing. This necessitates advanced metrology instruments capable of delivering repeatable measurements in the nanometer to sub-nanometer range. Slope ranges exceeding 15 mrad (0.86°) and greater pose significant challenges for mirror metrology using conventional interferometric methods. Here, to address this, we present a new relative angle determinable stitching interferometry instrument featuring a parallel flexure-based mechanical design. This approach enhances vibration and thermal stability while maintaining a compact and lightweight system. Initial measurements of a cylindrical mirror with a 16 m radius of curvature and a slope range of 5 mrad demonstrate nanometer-level repeatability. Comprehensive system characterization suggests the potential for achieving sub-nanometer repeatability with further refinement to the instrument.

36 MATERIALS SCIENCE↗

Iraq/Afghanistan war lung injury reflects burn pits exposure

This descriptive case series retrospectively reviewed medical records from thirty-one previously healthy, war-fighting veterans who self-reported exposure to airborne hazards while serving in Iraq and Afghanistan between 2003 and the present. They all noted new-onset dyspnea, which began during deployment or as a military contractor. Twenty-one subjects underwent non-invasive pulmonary diagnostic testing, including maximum expiratory pressure (MEP) and impulse oscillometry (IOS). In addition, five soldiers received a lung biopsy; tissue results were compared to a previously published sample from a soldier in our Iraq Afghanistan War Lung Injury database and others in our database with similar exposures, including burn pits. We also reviewed civilian control samples (5) from the Stony Brook University database. Military personnel were referred to our International Center of Excellence in Deployment Health and Medical Geosciences, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell under the auspices of Northwell IRB: 17-0140-FIMR Feinstein Institution for Medical Research “Clinicopathologic characteristics of Iraq Afghanistan War Lung Injury.” We retrospectively examined medical records, including exposure data, radiologic imaging, and non-invasive pulmonary function testing (MGC Diagnostic Platinum Elite Plethysmograph) using the American Thoracic Society (ATS) standard interpretation based on Morgan et al., and for a limited cohort, biopsy data. Lung tissue, when available, was examined for carbonaceous particles, polycyclic aromatic hydrocarbons (Raman spectroscopy), metals, titanium connected to iron (Brookhaven National Laboratory, National Synchrotron Light Source II, Beamline 5-ID), oxidized metals, combustion temperature, inflammatory cell accumulation and fibrosis, neutrophil extracellular traps, Sirius red, Prussian Blue, as well as polarizable crystals/particulate matter/dust. Among twenty-one previously healthy, deployable soldiers with non-invasive pulmonary diagnostic tests, post-deployment, all had severely decreased MEP values, averaging 42% predicted. These same patients concurrently demonstrated abnormal airways reactance (X5Hz) and peripheral/distal airways resistance (D5–D20%) via IOS, averaging – 1369% and 23% predicted, respectively. These tests support the concept of airways hyperresponsiveness and distal airways narrowing, respectively. Among the five soldiers biopsied, all had constrictive bronchiolitis. We detected the presence of polycyclic aromatic hydrocarbons (PAH)—which are products of incomplete combustion—in the lung tissue of all five warfighters. All also had detectable titanium and iron in the lungs. Metals were all oxidized, supporting the concept of inhaling burned metals. Combustion temperature was consistent with that of burned petrol rather than higher temperatures noted with cigarettes. All were nonsmokers. Neutrophil extracellular traps were reported in two biopsies. Compared to our prior biopsies in our Middle East deployment database, these histopathologic results are similar, since all database biopsies have constrictive bronchiolitis, one has lung fibrosis with titanium bound to iron in fixed mathematical ratios of 1:7 and demonstrated polarizable crystals. These results, particularly constrictive bronchiolitis and polarizable crystals, support the prior data of King et al. (N. Engl. J. Med. 365:222–230, 2011) Soldiers in this cohort deployed to Iraq and Afghanistan since 2003, with exposure to airborne hazards, including sandstorms, burn pits, and improvised explosive devices, are at high risk for developing chronic clinical respiratory problems, including: (1) reduction in respiratory muscle strength; (2) airways hyperresponsiveness; and (3) distal airway narrowing, which may be associated with histopathologic evidence of lung damage, reflecting inhalation of burned particles from burn pits along with particulate matter/dust. Non-invasive pulmonary diagnostic tests are a predictor of burn pit-induced lung injury

36 MATERIALS SCIENCE↗

Performance of microchannel plate based detectors for <25 keV x rays: Monte Carlo simulations and comparisons with experimental results

We present the results of Monte Carlo simulations of the microchannel plate (MCP) response to x rays in the 250 eV to 25 keV energy range as a function of both x-ray energy and impact angle and their comparisons with the experimental results from the X8A beamline at the National Synchrotron Light Source at Brookhaven National Laboratory. Incoming x rays interact with the lead glass of the microchannel plate, producing photoelectrons. Transport of the photoelectrons is neglected in this model, and it is assumed that photoelectrons deposit all their energy at the point they are created. This deposition leads to the generation of many secondary electrons, some fraction of which diffuse to the MCP pore surface where they can initiate secondary electron cascades in the pore under an external voltage bias. X-ray penetration through multiple MCP pore walls is increasingly important above 5 keV, and the effect of this penetration on MCP performance is studied. In agreement with past measurements, we find that the dependence of MCP sensitivity with angle relative to the pore bias changes from a cotangent dependence to angular independence and then proceeds to a secant dependence as the x-ray energy increases. We also find that with the increasing x-ray energy, the MCP gain sensitivity as a function of bias voltage decreases. The simulations also demonstrate that for x rays incident normal to the MCP surface, spatial resolution shows little dependence on the x-ray energy but degrades with the increasing x-ray energy as the angle of incidence relative to the surface normal increases. This agrees with experimental measurements. Simulation studies have also been completed for MCPs gated with a subnanosecond voltage pulse. In this work, we find that the optical gate profile width increases as the x-ray energy is increased above 5 keV, a consequence of increased x-ray penetration at energies >5 keV. Simulations of the pulsed dynamic range show that the dynamic range varies between ~100 and 1000 depending on x-ray energy and peak voltage.

47 OTHER INSTRUMENTATION↗

Multi frame radiography of supersonic water jets interacting with a foil target

Pulsed-power-driven underwater electrical explosion of cylindrical or conical wire arrays produces supersonic water jets that emerge from a bath, propagating through the air above it. Interaction of these jets with solid targets may represent a new platform for attaining materials at high pressure (>1010 Pa) conditions in a university-scale laboratory. However, measurements of the internal structure of such jets and how they interact with targets are difficult optically due to large densities and density contrasts involved. We utilized multi-frame x-ray radiographic imaging capabilities of the ID19 beamline at the European Synchrotron Radiation Facility to explore the water jet and its interaction with a 50 μm thick copper foil placed a few mm from the surface of water. The jet was generated with a ∼130 kA-amplitude current pulse of ∼450 ns rise time applied to a conical wire array. X-ray imaging revealed a droplet-type structure of the jet with an average density of <400 kg/m3 propagating with a velocity of ∼1400 m/s. Measurements of deformation and subsequent perforation of the target by the jet suggested pressures at the jet–target interface of ∼5 × 109 Pa. The results were compared to hydrodynamic simulations for better understanding of the jet parameters and their interaction with the foil target. These results can be used in future research to optimize the platform, and extend it to larger jet velocities in the case of higher driving currents supplied to the wire array.

Physics↗

CPU and memory efficient coherent mode decomposition for the partially coherent x-ray simulations

In this work, the method of the Coherent Mode Decomposition (CMD) is applied to numerical wave propagation calculations for partially-coherent X-rays, using the Fourier optics and compatible methods. Its CPU and memory efficiency is discussed in various cases of the wavefront at the source and the beam waist. With the absence of the quadratic phase terms, the required sampling density of the electric fields is effectively reduced. The problem size is thus moderate and the method is feasible to be implemented on a single-node CPU server. In other cases, the same argument holds with proper treatments of the quadratic phase terms. Tests on CMD and the modes propagation are done for the case of the Coherent Hard X-ray beamline of the National Synchrotron Light Source II, using the Synchrotron Radiation Workshop software. We observe a few hundred or less dominant decomposed modes that resemble the electric fields converge to the wavefront intensity at a high accuracy of over 99%.

36 MATERIALS SCIENCE↗

Adaptive shape control of wavefront-preserving X-ray mirrors with active cooling and heating

This article describes the development and testing of a novel, water cooled, active optic mirror system (called “REAL: Resistive Element Adjustable Length”) that combines cooling with applied auxiliary heating, tailored to the spatial distribution of the thermal load generated by the incident beam. This technique is theoretically capable of sub-nanometer surface figure error control even at high power density. Tests conducted in an optical metrology laboratory and at synchrotron X-ray beamlines showed the ability to maintain the mirror profile to the level needed for the next generation storage rings and FEL mirrors.

42 ENGINEERING↗