Search NASA⌕ Search

SEARCH · Search NASA

Results for “system noise temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Noise temperature and noise figure concepts: DC to light

The Deep Space Network is investigating the use of higher operational frequencies for improved performance. Noise temperature and noise figure concepts are used to describe the noise performance of these receiving systems. It is proposed to modify present noise temperature definitions for linear amplifiers so they will be valid over the range (hf/kT) 1 (hf/kT). This is important for systems operating at high frequencies and low noise temperatures, or systems requiring very accurate calibrations. The suggested definitions are such that for an ideal amplifier, T sub e = (hg/k) = T sub q and F = 1. These definitions revert to the present definition for (hf/kT) 1. Noise temperature calibrations are illustrated with a detailed example. These concepts are applied to system signal-to-noise analysis. The fundamental limit to a receiving system sensitivity is determined by the thermal noise of the source and the quantum noise limit of the receiver. The sensitivity of a receiving system consisting of an ideal linear amplifier with a 2.7 K source, degrades significantly at higher frequencies.

Stelzried, C. T.↗

A study of low-noise preamplifier systems for use with room temperature mercuric iodide /HgI2/ X-ray detectors

An analysis of different preamplification systems for use with room temperature mercuric iodide X-ray detectors has been performed. Resistor-, drain-, and light-feedback preamplifiers have been studied. Energy resolution values of 295 eV (FWHM) for an Fe-55 source (5.9 keV) and 225 eV (FWHM) for a pulser have been obtained with both the detector and the input FET at room temperature using a pulsed-light feedback preamplifier. Improvement in energy resolution by cooling the input FET using a small Peltier element has been discussed.

Iwanczyk, J. S.↗

Portable microwave test packages for beam-waveguide antenna performance evaluations

Portable microwave test packages used to evaluate a new 34-m-diameter beam-waveguide (BWG) antenna are described. The experimental methodology involved transporting test packages to different focal points of the BWG system and making noise temperature, antenna efficiency, and holography measurements. Comparisons of data measured at the different focal points enabled determinations of performance degradations caused by various mirrors in the BWG system. It is shown that, due to remarkable stabilities and accuracies of radiometric data obtained through the use of the microwave test packages, degradations caused by the BWG system were successfully determined.

Otoshi, Tom Y.↗

Development of a high stability microstrip-based L-band radiometer for ocean salinity measurements.

The development of a microstrip-based L-band Dicke radiometer with the long-term stability required for future ocean salinity measurements to an accuracy of 0.1 psu is presented. This will require the L-band radiometer requirements and configuration to achieve this objective. System configuration and component performance have been evaluated with radiometer test beds at both JPL and GSFC. The GSFC testbed uses a cryogenic chamber that al-lows long-term characterization at radiometric temperatures in the range of 70 - 120 K. The research has addressed several areas including component characterization as a function of temperature and bias, system linearity, optimum noise diode injection calibration and precision temperature control of components. A breadboard radiometer, utilizing microstrip-based technologies, has been built to demonstrate this long-term stability. This system is partially polarimetric providing V, H, -45 and +45 signals. Test results are compared to current and future ocean salinity radiometer requirements to show that the desire performance is possible.

Tanner, Alan B.↗

Noise Temperature Contribution of a Dichroic Plate in a Beam-Waveguide Antenna System

A 34m diameter antenna, built for NASA/JPL in 1990 at Goldstone, California, utilizes a beam-waveguide (BWG) design. It was discovered that if a dichroic plate is installed in a BWG antenna environment, high noise temperatures can result if the receiver system passband is greater than the passband for which the plate was designed. A method is presented for accurately calculating dichroic plate noise temperature for these conditions.

Dichroic Plate Beam-Waveguide Antenna↗

A radiometric method for measuring the insertion loss of radome materials

Radiometer system measures effective noise temperature directed towards sky, with and without radome over antenna horn. Data is then translated into computer format. With additional transmission line insertion loss data from other measurements, computer calculates insertion loss of radome material.

Seidel, B. L.↗

Performance evaluation and calibration of a modular multiband radiometer for remote sensing field research

A multiband radiometer suitable for operation from helicopter, small plane, truck, or tripod platforms was developed. The standard unit is equipped with the seven thematic mapper spectral bands with an added band from 1.5 to 1.30 microns; however, up to eight user specified bands from 0.4 to 15 microns may be installed under clean field conditions. Results of prototype tests of the spectral responsivity of the detectors, the transmittance of the optical filters as a function of wavelength, the fields of view, and the system linearity, temperature stability, noise performance, and dynamic range were evaluated. Minor modifications were made to the instrument and the results of final testing are reported.

Robinson, B. F.↗

Non-linearity in measurement systems: Evaluation method and application to microwave radiometers

A simple method for determination and correction of nonlinaearity in measurement systems is presented. The technique is applicable to a wide range of measuring systems. The basic concept, an analysis, and a sample application are given. Nonlinearity of the Goldstone DSS 13 low noise HEMT 2.3 GHz (S-band) radiometer system results in noise temperature measurement errors. These errors are successfully correct with this method.

Stelzried, C. T.↗

The Hyperspectral Microwave Photonic Instrument (HyMPI) and its NEDT Performance

This work presents an overview of a hyperspectral microwave-photonic spectrometer and demonstrates the system end-to-end noise equivalent delta temperature (NEDT) performance. The system aims at augmenting the remote sensing capability from space, with a focus on the Earth’s planetary boundary layer (PBL) thermal microwave (MW) spectral region (0-200 GHz). Combining a Photonic Integrated Circuit (PIC) channelizer and an application-specific integrated circuit (ASIC) spectrometer, the PIC & ASIC (PICASIC) module is capable of processing 40 GHz spectra at hyperspectral (4 MHz) resolution. The photonic technology is agnostic to the spectral region and multiple photonic modules can cover the entire 200 GHz spectrum. Measured results of the end-to-end system NEDT agree with predicted values confirming that the NEDT is primarily dominated by the noise figure of the MW front-end, with the optical link adding no significant noise. The data also demonstrate that a single module enables simultaneous super- and hyper-spectral resolution channel analysis across a 40 GHz range.

spectrometer↗

The S/X-Band Microwave Feed System for NASA's First Beamwaveguide Antenna

The configuration, detail design, and performance of the dual S/X-band microwave feed system for the first Deep Space Network (DSN) beamwaveguide (BWG) antenna are reported int his paper. By using existing spare components, simplifying the design of new components, and using new fabrication techniques and material, this feed system was implemented successfully with a small budget and a very tight schedule. The measured noise temperature of the feed systems is 17.5 Kelvin for S-band and 24.0 Kelvin for X-band, which agrees very closely with the predicted performance.

S/X-Band↗

Development of a High-Stability Microstrip-based L-band Radiometer for Ocean Salinity Measurements

The development of a microstrip-based L-band Dicke radiometer with the long-term stability required for future ocean salinity measurements to an accuracy of 0.1 psu is presented. This measurement requires the L-band radiometers to have calibration stabilities of less than or equal to 0.05 K over 2 days. This research has focused on determining the optimum radiometer requirements and configuration to achieve this objective. System configuration and component performance have been evaluated with radiometer test beds at both JPL and GSFC. The GSFC testbed uses a cryogenic chamber that allows long-term characterization at radiometric temperatures in the range of 70 - 120 K. The research has addressed several areas including component characterization as a function of temperature and DC bias, system linearity, optimum noise diode injection calibration, and precision temperature control of components. A breadboard radiometer, utilizing microstrip-based technologies, has been built to demonstrate this long-term stability.

Pellerano, Fernando A.↗

DSS-13 S-/X-band microwave feed system

The configuration, detail design, and performance of the dual S-/X-band microwave feed system for the new DSN beam-waveguide antenna, Deep Space Station (DSS) 13, are reported. By using existing spare components, reducing fabrication cost of new components by simplifying their design, and using new fabrication techniques and material, this DSS-13 feed system was implemented successfully with a small budget and a very tight schedule. Measured noise temperature gains of the feed system are 17.5 K for S-band (2200-2300 MHz) and 24.0 K for X-band (8200-8600 MHz), which agree very closely with the predicted performance.

Manshadi, F.↗

Evaluation of Propulsion Systems for Mach 2.4 and 3.2 High Speed Civil Transports

Advanced technology high speed civil transport (HSCT) engine cycles equipped with low emissions combustors and low noise exhaust nozzles were investigated. The objectives were as follows: (1) evaluate a range of cycle variables for engine types appropriate for Mach 2.4 and 3.2 HSCT; (2) select the most promising propulsion systems; and (3) identify and define the critical/key technology development and demonstration programs needed to be conducted prior to initiation of the product engine development and certification program. Two types of variable engines were studied: turbine bypass engines (TBE) and variable stream control engines (VSCE). This study identified payoffs in terms of aircraft gross weight, airline economics, stratospheric cruise emissions, and airport noise improvements. Comparison between the the TBE and VSCE showed the TBE to be clearly superior for Mach 2.4 and 3.2 cruise cruise operation. Critical technology areas were also identified which included the following: (1) Low emissions combustor; (2) Low noise exhaust system; (3) High temperature materials and coatings; (4) Advanced turbine cooling and aerodynamics; (5) Integrated propulsion system (inlet/engine/nozzle) and airframe controls; (6) Advanced fan/compressor aerodynamics; and (7) Magnetic bearings.

Turbine Bypass Engine (TBE)↗

Method to Measure Total Noise Temperature of a Wireless Receiver During Operation

A method has been developed to measure the total effective noise power in a GPS receiver, including contributions from the system temperature, the antenna temperature, interference, lossy components, etc. A known level of noise is periodically injected before the preamplifier during normal tracking, with a switch set to a very low duty cycle, so that there is insignificant signal loss for the GPS signals being tracked. Alternately, a signal of known power may be injected. The coupling port is fed with a switch that can be controlled from the receiver s digital processing section. The switch can connect the coupling port to a noise or signal source at a known power level. The combined system noise is measured, and nearly continuous noise calibrations are made. The effect from injected noise/signals on the performance of the GPS receiver can be less than 0.01 dB of SNR loss. Minimal additional components are required. The GPS receiver is used to measure the SNRs required to solve for the noise level. Because this measurement is referenced to the preamplifier input, it is insensitive to variations in the receiver gain.

Young, Lawrence E.↗

X-band, low-noise, traveling-wave maser

The development and performance of X-band traveling-wave maser (TWM) systems with effective input noise temperature of 3.5 K and bandwidths varying from 65 to 108 MHz is discussed. These TWMs are used on the 64-meter antennas at Deep Space Stations 14, 43 and 63 at 8420 MHz to meet the requirements of the Voyager-Saturn encounter. The TWMs use shortened and cooled signal input waveguide to reduce noise and are equipped with superconducting magnets and solid-state pump sources to provide the required stability performance.

Trowbridge, D. L.↗

433 micron laser heterodyne observations of galactic CO from Mauna Kea

A submillimeter heterodyne radiometer, developed for astronomical applications, uses an optically pumped laser local oscillator and a quasi-optical Schottky diode mixer. The resultant telescope-mounted system, which has a noise temperature less than 4000 K (double sideband) and high frequency and spatial resolution, has been used to detect the J = 6 to 5 rotational transition of carbon monoxide at 434 micrometers in the Orion molecular clouds. The measurements, when compared with previous millimeter-wave data, indicate that the broad carbon monoxide emission feature is produced by an optically thin gas whose temperature exceeds 180 K.

Buhl, D.↗