Virtual Agents-Based Attack-Resilient Distributed Control for Islanded AC Microgrid

Due to its dependence on a communication network, distributed secondary control of microgrids is susceptible to denial-of-service (DoS) attacks in channel shutdown mode, which may negatively impact the network connectivity and thus deteriorate the coordination and power sharing among distributed generators (DGs). Honeypot is a common method for cyber deception by introducing fake targets. However, in the context of microgrid, the misleading information spread by honeypots will also impact the system performance. This paper proposes an attack-resilient distributed control for AC microgrids utilizing virtual agents (VAs) to counteract both DoS edge and node attacks. The VAs are designed to not impact the system’s steady state during normal operation but to share information among neighboring real agents and serve as dummy targets for DoS attacks. The control with VAs is implemented by a primal-dual gradient based distributed algorithm to efficiently obtain a practical solution for voltage/frequency regulation and power sharing. The simulation results on a 4-DG test system and a modified IEEE 34-bus system show that 1) VAs do not impact the normal functionality of the test system, and 2) deploying VAs can enhance the resilience of the microgrid control against DoS edge and node attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Mechanical and Thermomechanical Water Vapor Compression Techniques for Enabling High Temperature Lift Hydration-Based Chemical Heat Pumps

Achieving high temperature lifts (>200 K) via a chemical heat pump based on salt hydration/dehydration reactions requires the transport of water vapor from low to high pressure. Alternative compression approaches require condensing of low-pressure water vapor, pumping of liquid water, and subsequent evaporation when the low-side pressure corresponds to sub-ambient water saturation temperatures. Thus, this study compares four steam compression methods for use within a chemical heat pump system based on a reversible calcium oxide hydration/dehydration reaction with a temperature lift from 350 °C heat to >600 °C. Purely mechanical and thermochemical/mechanical compression technologies are considered. A parametric study of maximum allowable temperature, the isentropic efficiency of mechanical compressors, the effectiveness of heat exchangers, and the assumed allowable heat exchanger pressure drop is conducted to determine the mechanical and thermal energy consumed per kilogram of compressed steam. The system complexity in terms of the number of main system components, maximum pressure ratio, and maximum allowable temperature is estimated. Model results show an absorption-based steam compressor has the highest exergetic efficiency for the required chemical heat pump required conditions. As a result, this system configuration was then experimentally demonstrated to illustrate the impact of system performance on component effectiveness.

Advanced reactors↗

Advancing the HERO WEC Through Integrated Modeling, Testing, and Field Deployments

The Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC) was developed by the National Laboratory of the Rockies as a modular platform for advancing wave-powered desalination technologies. Designed to operate in either a hydraulic or electric configuration, the system enables direct comparison of mechanical-to-water and electrical-to-water conversion pathways using a single hardware architecture. Deployments in 2022 and 2024 at the Jennette's Pier test site in North Carolina demonstrated freshwater production between 60 and 300 gallons per day, including successful operation in wave heights as low as 0.25 m. A structured evaluation approach combining numerical modeling of hydrodynamic and power take-off response, controlled laboratory testing, and in-ocean field deployments has been used to characterize and refine system performance. Specifically, insights from these efforts are now informing the second-generation HERO WEC (V2) to increase robustness and overall survivability. Changes from the original prototype include improved drivetrain components, refined geometry, enhanced control systems, and design. The HERO WEC platform continues to serve as an open-access research asset supporting broader marine energy and desalination development.

16 TIDAL AND WAVE POWER↗

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data↗

Research to Address Technical Barriers to Expanded Markets for Biodiesel and Biodiesel Blends (CRADA Final Report)

NREL and the Clean Fuels Alliance America (CFAA) will work cooperatively to assess the effects of biodiesel blends on the performance of modern diesel engines. This work will include research to understand the impact of biodiesel blends on the operation and durability of particle filters and NO x control sorbents/catalysts, to quantify the effect on emission control systems performance, and to understand effects on engine component durability. This research was performed at NREL Renewable Fuels and Lubricants (REFUEL) laboratory (an engine testing laboratory) as well as at third party labs paid directly by CFAA with NREL as part of the project management team. Also, research to develop appropriate ASTM standards for biodiesel quality and stability was conducted in NREL’s bench scale fuel chemistry laboratory. The cooperative project involved laboratory testing and research at NREL using biodiesel from a variety of sources and in collaboration with a broad range of other stakeholders. In addition, NREL will work with NBB to set up an Industrial Steering Committee to design the scope for the various tasks and to provide technical oversight to these projects. NREL and NBB will cooperatively communicate the study results to as broad an audience as possible. This research benefits the public by expanding markets for a domestically produced low-carbon intensity fuel for use in diesel engines.

09 BIOMASS FUELS↗

Immersive Analytics in Critical Spatial Domains: From Materials to Energy Systems

Immersive analytics (IA) leverages virtual reality, augmented reality, and mixed reality to transform how users interact with complex datasets across domains such as science, industry, and education. These immersive technologies offer spatial and multimodal environments that foster intuitive exploration, but they also introduce challenges related to cognitive load, interface design, and system performance. Here, this article presents a comprehensive review of visualization techniques, interaction models, and multimodal inputs utilized in IA. Drawing on case studies in scientific visualization, industrial training, and educational communication, we examine both the potential and limitations of current systems. Finally, we propose future research directions, focusing on real‐time collaboration, adaptive user interfaces, and scalable data exploration strategies to advance the field.

99 - GENERAL AND MISCELLANEOUS↗

Holistic Small-Signal Stability Analysis for Large-Scale Inverter-Intensive Power Systems with Coupled and Full-Order Dynamics from Control Systems and Power Networks

The increasing penetration of inverter-based resources (IBRs) into the existing power systems introduces tremendous benefits for enhanced sustainability but also poses inevitable challenges in terms of insufficient inertia, potential instability, and complex network dynamics, among others. However, the additional coupling introduced by the interactions among gridfollowing (GFL) and grid-forming (GFM) IBRs and the other components (i.e., synchronous generators [SGs], loads, and network, etc.) has not been clearly explored. A holistic, scalable, and quantitative stability analysis framework with the control systems and power networks is still missing. Here, in this paper, to fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established. An extended power flow model with operation dynamics from both generator control schemes and power networks is proposed to provide the varying steady-state operating points for small-signal modeling. The proposed method is compared with MATLAB solvers, and the results show that the proposed approach has a minimum calculation time, which can be less than 12 seconds for a large-scale power system with up to 2,000 buses. Furthermore, a quantitative method is developed to identify the impacts of IBRs on system performance with emphases on the potential stability issues with GFL IBRs, additional benefits of employing GFM IBRs, the feasibility of replacing SGs with GFM IBRs, and the impact of penetration level of different kinds of generation units. Finally, a field island power system is used to verify the proposed approach, and hardware-in-the-loop (HIL) tests are provided to further demonstrate the effectiveness of the proposed analysis.

14 SOLAR ENERGY↗

Modeling and Analysis of Clean Energy and Storage Technologies (CRADA Final Report, Project 1)

The goal of this project is to provide Southern Company Services, Inc. ("Participant") with custom scripts that can be used to create an average PV energy production profile, calculate lifetime energy value, calculate capacity value, and calculate the resultant financial metrics considering those value streams. Secondly, a fuel-cell model will be added to the public version of System Advisor Model (SAM). This standalone technology will incorporate PV and battery storage, allowing the participant to model the interaction of these three technologies. By adding this capability to a public version of SAM, a broad audience will be able to consider the system performance and financial benefits of installing a fuel cell as a baseline generator with PV. Thirdly, automated dispatch algorithms will be developed and added to SAM. These algorithms will enable Southern Company to dispatch a DC-connected front-of-the-meter battery system while considering price signals and PV clipping behavior. By adding these capabilities to a public version of SAM, users will be able to consider more complex and realistic ways of dispatching a battery system.

14 SOLAR ENERGY↗

Relating Aerial Infrared Thermography Defects to Photovoltaic Performance: Preprint

In this research, we examine the relationship between aerial IR defect analysis and photovoltaic (PV) performance data for twelve utility- and commercial-scale solar sites in the United States. To do this, we fuse the site diagram geoJSON's, aerial infrared thermography (aIRT) defect analyses, and associated inverter time series, allowing for a direct comparison between site defects and time series data. Defect analyses were provided by Zeitview, under its Solar Insights platform. Following the data fusion process, we look at the relationship between system performance and aIRT defects. We investigate the relationship between degradation and hotspot defects, as well as the relationship between AC power data and offline strings and misaligned modules. In general, system degradation was not affected by long-term or balance-of-system (BoS) defects as they occurred infrequently in the data set. However, for one system, a near statistically significant relationship (p-value=0.057) was found when comparing the degradation of inverter blocks with several multi-hotspot defects to all other inverter blocks without this particular defect. There was strong alignment when comparing short-term recoverable module defects such as stuck trackers and offline strings to time series data. In general, we found that when an inverter block has more than 80% of modules flagged for one of these defects, its AC power time data is flat-lined and the inverter block is not producing.

aerial inspection↗

Mu2e resonant extraction regulation system simulation in delivery ring

Mu2e is an upcoming experiment at Fermilab that relies on the slowly extracted 8 GeV proton beam from the Delivery Ring. The experiment imposes strong requirements on the spill uniformity. To address these requirements, the fast spill regulations system is being developed and commissioned. To inform this development and optimize the system performance we are carrying out the detailed simulations of the regulation process. The simulation includes the effect of six harmonic sextupoles that excite the third-integer resonance and three fast ramping quadrupoles that drive the horizontal tune to 29/3. The components of spill regulation system are designed to mitigate long-term drifts in the beam, ensuring stable operation over extended timescales, as well as addresses rapid variations within single spill. In this study, we review the regulation system design, simulation of the slow regulation, and the fast regulation PID regulation to curtail random variations in the extraction rate that could occur within a single spill.

Narayanan, Aakaash [Fermilab]↗

Scaleup and Site-Specific Engineering Design for Global Thermostat Direct Air Capture Technology

The overall goal of the project is completion of an initial design of a commercial-scale, Carbon Capture, Utilization, and Storage Direct Air Capture (CCUS-DAC) plant design at three different sites that captures a net of at least 100,000 tonnes per year (TPY) carbon dioxide (CO 2 ) from the atmosphere and considers compression and conditioning of the captured CO 2 for purpose of pipeline transportation to different geological formation sites for deep well injection and underground storage. In addition to the leading system consisting of a scaled-up Global Thermostat DAC unit, overall plant design includes a combined Heat and Power (CHP) unit integrated with a conventional liquid amine-based carbon capture system (90% capture) and compression facilities. These are considered balance of plant (BOP) systems and are required to provide low carbon-intensity steam and power to the DAC process. A second approach involving provision of DAC units modified to directly capture emissions from the CHP unit was initially assessed as an alternative and it was determined to be less mature than considered approach and not included in the scaled-up plant design efforts. Three geographically diverse continental United States locations were selected to better understand the effect of local/regional ambient conditions on scaled-up DAC system performance and project costs: Bucks, Alabama (hot wet climate), Odessa, Texas (dry hot climate), and Goose Creek, Illinois (mid continental climate). The team focused on initial engineering design activities, including the development of project design criteria, initiation of site-specific studies and investigations, completion of DAC system process and equipment design, and definition of balance of plant (BOP) engineering. The purpose of the activities were to develop Technoeconomic Analysis (TEA), Life-Cycle Analysis (LCA), and Environmental, Health, and Safety (EH&S) analysis, and Business Case Analysis (BCA) to validate that the project engineering and scale-up plans of the DAC systems, at each of the three distinct case studies considered, are technically, economically, and environmentally feasible for commercial-scale operation.

20 FOSSIL-FUELED POWER PLANTS↗

Development, Monitoring, and Control of Fracture Thermal Energy Storage (FTES) in Crystalline Rock Formations (DEMO-FTES) (CRADA Final Report)

The DEMO-FTES project sought to demonstrate the thermal efficiency of fracture thermal energy storage (FTES) through numerical simulations, laboratory and meso-scale field tests. A detailed dimensional and scaling analysis was performed to identify key parameters and how they can be most effectively scaled to the laboratory and decameter scale. Numerical models were developed and used for three purposes: 1. Before field experiments, numerical modelling can be used to estimate fracture properties based on previous data from the EGS Collab experiment and then predict thermal hydrological behaviors of the fracture system with hot water injection/withdrawal, therefore, help to design the experiments (e.g., to decide the duration of the cycles based on the flow rate the pump can provide, and the estimated fracture properties); 2. After the field experiment, to estimate the system properties during the experiment (as the size and shape of a fracture could change over time), and understand why system performance is different than what has been predicted, i.e., to help understand the meso-scale test; and, 3. To model the lab experiments and estimate fracture properties and storage efficiency. Ultimately, the experiment and numerical models could shed light on the processes and uncertainty happening during fracture activation and help understand the scaling between lab and field test, and finally, the design and optimization of potential fracture thermal energy storage systems.

25 ENERGY STORAGE↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

Mobility Energy Productivity (MEP) Metric: Partnerships, Applications, and Key Enhancements

The Mobility Energy Productivity (MEP) metric is a holistic measure of transportation systems performance that quantifies the ability of individuals to reach destinations in a cost-efficient and energy-efficient manner. This presentation highlights recent partnerships that have advanced the adoption of MEP as a decision-support tool by various agencies, stakeholders, and researchers. Applications include evaluating multimodal accessibility, comparing system-level energy impacts, and informing infrastructure investment strategies. Key enhancements to the metric - such as expanded regional applications and incorporation of emerging technologies - are also discussed. Together, these efforts highlight the potential of MEP to inform data-driven decisions that shape future transportation systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High-Fidelity and High-Performance Computational Simulations for Rapid Design Optimization of Sulfur Thermal Energy Storage

Industrial process heating (IPH) accounts for approximately 70% of US manufacturing energy use and is primarily produced by fossil fuel combustion. Approximately 1500 TWht (approximately 60%) of IPH demand is in the temperature range of 100-300. Industrial applications in this temperature range include drying, hydrothermal processing, thermal enhanced oil recovery, food and beverage, bioethanol production, etc. Cost-effective thermal energy storage (TES) that increases the utilization of waste and renewable heat (solar, geothermal, etc.) could provide significant energy savings and reliable heat sources, decrease emissions, and increase US manufacturing competitiveness through reductions in fuel consumption. TES development has historically been dominated by technologies suitable for deployment with concentrating solar power (CSP). State-of-the-art thermal storage deployed commercially with power tower CSP plants uses a 60%/40% NaNO3/KNO3 molten salt and operates between temperatures of approximately 280 degrees Celsius and 570 degrees Celsius using a two-tank configuration. However, these nitrate salts are unsuitable for operation outside of this temperature range due to a high freezing point of approximately 220 degrees Celsius, and limits on high-temperature salt stability and corrosion resistance of containment alloys. Other materials being investigated for TES include those based on: (1) sensible energy storage (various molten salt compositions, inert solid particles, rocks or pebble beds, sulfur, water, concrete, graphite, etc.), (2) latent energy storage in materials that undergo solid-liquid phase change at relevant temperatures (organic materials for low-temperature applications, inorganic salts and/or metals for high-temperature applications), or (3) thermochemical energy storage (hydrides, hydroxides, carbonates, metal oxides, etc.). The application temperature and challenges pertaining to storage material and/or containment cost, energy density, long-term thermal and cyclic stability, and charge/discharge heat transfer effectiveness drive material selection for a given IPH or electricity generation application. Sulfur is a cheap commodity at $80/ton compared to $1100 - 1300/ton for conventional salts. When using a metric of storage cost per kWh, sulfur costs around 2-3 $/kWh. Previous sulfur TES development focused on high temperature (>600 degrees) concentrated solar power applications with sulfur encapsulated in pipes and flow of gaseous HTF (air) in the shell side. However, for lower-temperature IPH applications in the range of approximately 100-300 degrees Celsius Element 16 adopted a compact and scalable TES design with molten sulfur in the shell and HTF pipes submerged in the molten sulfur bath. The low-cost molten sulfur TES for dispatchable IPH has deployment potential for broad applications. The spatial and temporal evolution of the HTF and sulfur temperature is critical to the TES system performance, and thus detailed modeling can improve understanding of the performance and facilitate design improvements. Using high performance computing and computational fluid dynamics (CFD) a low-cost molten sulfur thermal energy storage (TES) system for industrial process heating (IPH) applications was developed. The unique challenges in CFD modeling of sulfur TES are the sharp property changes of sulfur relevant to the working temperatures. Above 159, liquid sulfur undergoes polymerization, and the viscosity of sulfur rapidly increases by several orders of magnitude between 159 degrees Celsius and 188 degrees Celsius, followed by a decrease in viscosity beyond 188 degrees Celsius due to thermal bound dissociation. In addition, various concentrations of H2S impurities can also modify sulfur viscosity. This numerical challenge is especially relevant to transient simulation of the sulfur TES charging and discharging processes as the extreme property variations limit the applicability of traditional heat transfer correlations. Transient CFD simulations including the temperature-dependent sulfur properties and geometric complexity of the TES design were used to predict the effect of natural convection during charging and discharging on the heat transfer process, sulfur temperature uniformity, charge/discharge rates, and performance of the storage devices. The CFD model was validated with experimental results for a full charge and discharge cycle. The work will show 3D and 2D simulation comparisons aimed to facilitate rapid design iterations and a machine learning based design optimization approach.

CFD↗

Fundamentals of Solar PV Bolted Joint Loosening and Prevention

The photovoltaic (PV) industry has long reported anecdotal accounts of systems exhibiting intermittent or chronic fastener loosening, including joints that fail to maintain preload despite multiple re-tightening attempts. These occurrences are frequently, and often incorrectly, attributed to installer errors, vibration, or loading beyond design expectations (e.g., extreme weather events). Loose fasteners have serious implications and can significantly impact solar PV systems’ performance, reliability, and safety. However, effective bolted joint design and proper assembly practices can mitigate or eliminate loosening. Until the US Department of Energy’s Solar Energy Technologies Office (SETO) funded research on fasteners and solar PV structures, there was a notable gap in understanding the causes of loosening in solar PV systems.

14 SOLAR ENERGY↗

Control co-design under uncertainty for offshore wind farms: Optimizing grid integration, energy storage, and market participation

Offshore wind farms (OWFs) are set to significantly contribute to global decarbonization efforts. Developers often use a sequential approach to optimize design variables and market participation for grid-integrated offshore wind farms. However, this method can lead to sub-optimal system performance, and uncertainties associated with renewable resources are often overlooked in decision-making. Here, this paper proposes a control co-design approach, optimizing design and control decisions for integrating OWFs into the power grid while considering energy market and primary frequency market participation. Additionally, we introduce optimal sizing solutions for energy storage systems deployed onshore to enhance revenue for OWF developers over time. This framework addresses uncertainties related to wind resources and energy prices. We analyze five U.S. west-coast offshore wind farm locations and potential interconnection points, as identified by the Bureau of Ocean Energy Management (BOEM). Results show that optimized control co-design solutions can increase market revenue by 3.2% and provide flexibility in managing wind resource uncertainties.

Control Co-design↗

Techno-Economic Analysis and Market Potential of Geological Thermal Energy Storage (GeoTES) Charged With Solar Thermal and Heat Pumps

In this project, we developed a techno-economic analysis (TEA) model that can be used to evaluate the viability of a proposed Geological Thermal Energy Storage (GeoTES) design. This MATLAB-based model integrates distinct subsystem models for the reservoir, wells, power cycle, and solar field to capture their distinct characteristics. It applies this approach in simulating GeoTES storage and dispatch operations for durations ranging from hourly to seasonal. Using cases studies based on GeoTES designs provided by industry partners - Premier Resource Management (PRM) and EarthBridge Energy - we validated the TEA model estimations of system performance and costs (such as thermal and electrical power/energy inflow and outflow, capital costs, and levelized costs of energy and storage) for both concentrating solar thermal (CST) and Carnot Battery (CB) pairings with GeoTES (CST-GeoTES and CB-GeoTES). For the CST-GeoTES case, the model was validated against the proposed system designed by PRM. It showed good agreement with PRM's estimations when well and pump costs derived from PRM's estimations were used. When GETEM-based costs were used, there was a slight overprediction due to GETEM's project/site agnostic assumption of these costs. From a sensitivity analysis perspective, the levelized cost of electricity (LCOE) of the CST-GeoTES case was most sensitive to well flow rate and the charging temperature. An optimal design scenario resulted in an LCOE of 0.11 $\$$/kWhe. CST-GeoTES can also provide a source of heat to meet seasonal demands. With 12-hour and 24-hour levelized cost of heat (LCOH) of 0.018 $\$$/kWhth and 0.022 $\$$/kWhth, respectively, CST-GeoTES could be competitive in the California market with an average industrial price of natural gas in California between 0.041-0.047 $\$$/kWhth. The levelized cost of storage (LCOS) for CST-GeoTES depends on the energy storage duration. Although the LCOS is relatively higher for shorter durations (e.g., ~0.50 $\$$/kWhe for 1 hour of storage), it is an order of magnitude lower (0.06 $\$$/kWhe) for longer storage durations and competitive with lithium-ion batteries (beyond 12 hours of storage) and molten-salt thermal energy storage (beyond 32 hours). Energy. Three options were explored and applied to the EarthBridge case study: (1) A Carnot Battery design using R125 working fluid with both hot and cold storage; (2) A Carnot Battery design using R125 working fluid with only hot storage; (3) A Carnot Battery using a commercially available heat pump with carbon dioxide (CO2) working fluid and hot storage only. The CB-GeoTES with cold storage only had a slight (round-trip) efficiency advantage over the system without (43.4% vs. 42.8%). This is because the cold storage is limited by the freezing point of water, so the cold storage is not much colder than the environment. The system using commercially available technologies was the least efficient - partly because different cycles were used in the heat pump (CO2) and heat engine (binary cycle) which leads to some inefficiencies. Using the commercially available design, the levelized cost of energy (LCOS) from the model (0.10 $\$$/kWhe) was higher than that estimated by EarthBridge (0.068 $\$$/kWhe). This is because of the low round-trip (38.7%) efficiency of the commercially available design. Sensitivity analysis reveals that the model is most sensitive to electricity price. Including electricity price in the TEA for CB-GeoTES leads to an increase in LCOS from the base value to 0.25 $\$$/kWhe. To determine storage sites suitable for GeoTES, we gathered and analyzed geological, petrophysical, and geophysical data of oil and gas reservoir and aquifers in California and Texas. We down-selected possible sites based on cut-off values for site characteristics (e.g., reservoir temperature, formation thickness, permeability, porosity, depth, and brine salinity) and preliminary costs. Using this approach, the Carrizo-Wilcox, Yegua-Jackson, and Dockum brackish aquifers in Texas were identified as having the highest suitability. Similarly, in the central California region, the White Wolf, Belridge South Tulare, and Belridge South Reef Ridge were the most suitable. Going further, we assessed the storage potential in the selected sites. To do this we developed distributions of reservoir characteristic data and applied a Monte Carlo-based analysis to account for intrinsic uncertainty in the acquired data. The analysis revealed that the Carrizo-Wilcox aquifer had the highest storage potential with a mean capacity of 554 TWhth (i.e., 63 TWhe). The estimated capacity serves as an upper limit of storage potential given that not all fields in the basin will be developed. We participated in multiple outreach activities including conference presentations, panel session discussions, and the facilitation of a GeoTES workshop at the NREL Golden campus.