Search NASA⌕ Search

SEARCH · Search NASA

Results for “targeted quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

TU-EF-210-03: Real-Time Ablation Monitoring and Lesion Quantification Using Harmonic Motion Imaging

The use of therapeutic ultrasound to provide targeted therapy is an active research area that has a broad application scope. The invited talks in this session will address currently implemented strategies and protocols for both hyperthermia and ablation applications using therapeutic ultrasound. The role of both ultrasound and MRI in the monitoring and assessment of these therapies will be explored in both pre-clinical and clinical applications. Katherine Ferrara: High Intensity Focused Ultrasound, Drug Delivery, and Immunotherapy Rajiv Chopra: Translating Localized Doxorubicin Delivery to Pediatric Oncology using MRI-guided HIFU Elisa Konofagou: Real-time Ablation Monitoring and Lesion Quantification using Harmonic Motion Imaging Keyvan Farahani: AAPM Task Groups in Interventional Ultrasound Imaging and Therapy Learning Objectives: Understand the role of ultrasound in localized drug delivery and the effects of immunotherapy when used in conjunction with ultrasound therapy. Understand potential targeted drug delivery clinical applications including pediatric oncology. Understand the technical requirements for performing targeted drug delivery. Understand how radiation-force approaches can be used to both monitor and assess high intensity focused ultrasound ablation therapy. Understand the role of AAPM task groups in ultrasound imaging and therapies. Chopra: Funding from Cancer Prevention and Research Initiative of Texas (CPRIT), Award R1308 Evelyn and M.R. Hudson Foundation; Research Support from Research Contract with Philips Healthcare; COI are Co-founder of FUS Instruments Inc Ferrara: Supported by NIH, UCDavis and California (CIRM and BHCE) Farahani: In-kind research support from Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

A Sheaf Theoretical Approach to Uncertainty Quantification of Heterogeneous Geolocation Information

Integration of multiple, heterogeneous sensors is a challenging problem across a range of applications. Prominent among these are multi-target tracking, where one must combine observations from different sensor types in a meaningful and efficient way to track multiple targets. Because different sensors have differing error models, we seek a theoretically justified quantification of the agreement among ensembles of sensors, both overall for a sensor collection, and also at a fine-grained level specifying pairwise and multi-way interactions among sensors. We demonstrate that the theory of mathematical sheaves provides a unified answer to this need, supporting both quantitative and qualitative data. Furthermore, the theory provides algorithms to globalize data across the network of deployed sensors, and to diagnose issues when the data do not globalize cleanly. We demonstrate and illustrate the utility of sheaf-based tracking models based on experimental data of a wild population of black bears in Asheville, North Carolina. A measurement model involving four sensors deployed among the bears and the team of scientists charged with tracking their location is deployed. This provides a sheaf-based integration model which is small enough to fully interpret, but of sufficient complexity to demonstrate the sheaf’s ability to recover a holistic picture of the locations and behaviors of both individual bears and the bear-human tracking system. A statistical approach was developed in parallel for comparison, a dynamic linear model which was estimated using a Kalman filter. This approach also recovered bear and human locations and sensor accuracies. When the observations are normalized into a common coordinate system, the structure of the dynamic linear observation model recapitulates the structure of the sheaf model, demonstrating the canonicity of the sheaf-based approach. However, when the observations are not so normalized, the sheaf model still remains valid.

97 MATHEMATICS AND COMPUTING↗

Statistically-driven Experimental Design to Improve Reference-free Quantification of Small Molecules by Liquid Chromatography-Mass Spectrometry

Non-targeted analysis of small molecules and metabolites in unknown, complex samples using liquid chromatography-tandem mass spectrometry remains challenging. One of the main bottlenecks is the extensive unannotated regions of metabolomics mass spectrometry data, resulting in knowledge gaps. Small molecule annotation in mass spectrometry data has conventionally relied on reference standards and libraries for compound identification and confirmation, which can constrain compound identification to those molecules already known, thus limiting the ability to discover new knowledge and new markers. Retention time prediction can facilitate and expedite unknown compound identification in non-targeted analysis of complex metabolomics samples. Additionally, accurate retention time predictions can also inform sample mixture design for LC-MS/MS analyses. However, current machine learning-based methods for retention time prediction are typically developed for specific chromatographic platforms and are not generalizable across scales. And while technologies and methods to improve reference-free metabolite identification for more comprehensive annotation of unknowns has received much attention, development of the same for quantitation without reference standards has been much more limited, despite its importance in toxicological, environmental, food safety, forensics, and clinical applications. We believe that a reference-free quantitation strategy that exploits mass spectrometry data already collected for reference-free identification can provide much more insight on unknowns, and move the metabolomics field for more complete unknowns characterization. As such, we pursue two efforts to improve upon current state-of-the-art methods in non-targeted analysis: (1) machine learning-based retention time prediction and (2) statistical design of experiments framework for reference-free quantitation. In this work, we develop and demonstrate (1) a generalizable retention time prediction capability across chromatographic conditions and scales, and (2) a statistical design-based framework for response factor contribution elucidation and reference-free quantitation. Evaluation of our retention time prediction model, PrediToR, showed approximately 24% improvement over current models, and we observed approximately 10X improvement in concentration estimation accuracy from our statistical design-based response factor model over a primarily ionization efficiency-based model. We expect that future efforts to improve upon these new capabilities will further advance non-targeted analysis of small molecules towards truly reference-free metabolomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The E3 ligase for metastasis associated 1 protein, TRIM25, is targeted by microRNA-873 in hepatocellular carcinoma

Highlights: • TRIM25 degrades pro-metastatic protein in hepatocellular carcinoma MTA-1. • TRIM25 expression is downregulated in HCC by miR-873. • Decreasing miR-873 expression can decrease metastasis in xenograft models. • MiR-873 thus can serve as a marker and therapeutic target in HCC patients. Tumor metastasis accounts for 90% of all cancer-related deaths. Epithelial to mesenchymal transition (EMT) considered to be centrally important in acquired resistance to chemotherapy and in progression of tumors to secondary organs. One of the important mediators of metastatic progression in hepatocellular carcinoma (HCC) is the metastasis associated protein 1 (MTA-1). We have earlier shown that in the context of HCC and normal liver cell lines, MTA-1 protein is actively stabilized in HCC cell lines and actively degraded in normal liver cells. We have also shown that TRIM25 is the E3 ligase that interacts with and degrades MTA-1 protein. The identity of the factor regulating expression of TRIM25 in normal liver cells and HCC is unknown. In the current work we elucidate that microRNA (miR)− 873 targets TRIM25 in HCC cells. Both metagenomic analysis and quantification of miR-873 and TRIM25 in 25 HCC patients revealed an inverse correlation between the two in HCC patients with high miR-873 and low TRIM25 expression, respectively. The expression pattern was mimicked in the normal liver cells THLE-2 and the HCC cell line, HuH6. In vitro luciferase reporter assays confirmed TRIM25 as the target of miR-873. Transient transfection of HuH6 cells with an anti-miR-873 antagomir significantly decreased both transwell motility in these cells. Furthermore, in in vivo xenograft assays treatment with anti-miR-873 antagomir significantly decreased hepatic nodules formation. Cumulatively, our data indicate that suppression of TRIM25 expression by high levels of miR-873 dictates MTA1 protein upregulation in HCC.

60 APPLIED LIFE SCIENCES↗

Toward machine-learning-assisted PW-class high-repetition-rate experiments with solid targets

We present progress in utilizing a machine learning (ML) assisted optimization framework to study the trends in a parameter space defined by spectrally shaped, high-intensity, petawatt-class (8 J, 45 fs) laser pulses interacting with solid targets and give the first simulation-based overview of predicted trends. A neural network (NN) incorporating uncertainty quantification is trained to predict the number of hot electrons generated by the laser–target interaction as a function of pulse shaping parameters. The predictions of this NN serve as the basis function for a Bayesian optimization framework to navigate this space. For post-experimental evaluation, we compare two separate neural network (NN) models. One is based solely on data from experiments, and the other is trained only on ensemble particle-in-cell simulations. Reviewing the predicted and observed trends across the experiment-capable laser parameter search space, we find that both ML models predict a maximal increase in hot electron generation at a level of approximately 12%–18%; however, no statistically significant enhancement was observed in experiments. On direct comparison of the NN models, the average discrepancy is 8.5%, with a maximum of 30%. Since shot-to-shot fluctuations in experiments affect the observations, we evaluate the behavior of our optimization framework by performing virtual experiments that vary the number of repeated observations and the noise levels. Here, we discuss the implications of such a framework for future autonomous exploration platforms in high-repetition-rate experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantifying spatial resolution in a fast neutron radiography system

Neutron imaging is a powerful nondestructive examination modality that has been employed in various applications. Fast neutrons provide advantages over lower energy neutrons, such as examining thicker samples and inducing negligible activation and transmutations. However, fast neutrons interact mostly via elastic scattering with both the neutron detector and the object, causing degradation in spatial resolution. This study explores the quantification of spatial resolution caused by the testing target itself and suggests proper candidate materials for characterizing spatial resolution in terms of modulation transfer function. Knife-edge radiographs of 3 mm, 6 mm, and 5 cm thick Tantalum (Ta) foils, and a 2.54 cm Tungsten (W) cube were acquired using a CCD-based imaging system and a Polyvinyl Toluene (PVT) scintillator at the Ohio State Research Reactor (OSURR)’s fast neutron beam facility. The spatial resolutions calculated were 195 ± 20 μm, 224 ± 22 μm, 248 ± 25 μm, and 435 ± 44 μm for 3 mm, 6 mm, and 5 cm Ta foils, and 2.54 cm W cube, respectively. The results showed a worsening spatial resolution with increasing target thickness. Simulations and calculations estimate that elastic scattering kinematics between neutrons and protons in the PVT medium also limits spatial resolution, and it sets a lower limit of ~44 μm on the spatial resolution for 2 MeV neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Guiding the choice of informatics software and tools for lipidomics research applications

Progress in mass spectrometry lipidomics has led to a rapid proliferation of studies across biology and biomedicine. These generate extremely large raw datasets requiring sophisticated solutions to support automated data processing. To address this, numerous software tools have been developed and tailored for specific tasks. However, for researchers, deciding which approach best suits their application relies on ad hoc testing, which is inefficient and time consuming. Here we first review the data processing pipeline, summarizing the scope of available tools. Next, to support researchers, LIPID MAPS provides an interactive online portal listing open-access tools with a graphical user interface. This guides users towards appropriate solutions within major areas in data processing, including (1) lipid-oriented databases, (2) mass spectrometry data repositories, (3) analysis of targeted lipidomics datasets, (4) lipid identification and (5) quantification from untargeted lipidomics datasets, (6) statistical analysis and visualization, and (7) data integration solutions. Detailed descriptions of functions and requirements are provided to guide customized data analysis workflows.

59 BASIC BIOLOGICAL SCIENCES↗

Deep-learning-enabled Bayesian inference of fuel magnetization in magnetized liner inertial fusion

Fuel magnetization in magneto-inertial fusion (MIF) experiments improves charged burn product confinement, reducing requirements on fuel areal density and pressure to achieve self-heating. By elongating the path length of 1.01 MeV tritons produced in a pure deuterium fusion plasma, magnetization enhances the probability for deuterium–tritium reactions producing 11.8-17.1 MeV neutrons. Nuclear diagnostics thus enable a sensitive probe of magnetization. Characterization of magnetization, including uncertainty quantification, is crucial for understanding the physics governing target performance in MIF platforms, such as magnetized liner inertial fusion (MagLIF) experiments conducted at Sandia National Laboratories, Z-facility. We demonstrate a deep-learned surrogate of a physics-based model of nuclear measurements. A single model evaluation is reduced from O ( 10 – 100 ) (10–100) CPU hours on a high-performance computing cluster down to O ( 10 – 100 ) (10) ms on a laptop. This enables a Bayesian inference of magnetization, rigorously accounting for uncertainties from surrogate modeling and noisy nuclear measurements. The approach is validated by testing on synthetic data and comparing with a previous study. We analyze a series of MagLIF experiments systematically varying preheat, resulting in the first ever systematic experimental study of magnetic confinement properties of the fuel plasma as a function of fundamental inputs on any neutron-producing MIF platform. We demonstrate that magnetization decreases from B R ∼ 0.2 ~0.5 to B R ∼ 0.2 ~0.2 MG cm as laser preheat energy deposited increases from E preheat ∼ 460 ~460 J to E preheat ∼ 460 ~1.4 kJ. This trend is consistent with 2D LASNEX simulations showing Nernst advection of the magnetic field out of the hot fuel and diffusion into the target liner.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron scattering on A = 3 nuclei from quantum Monte Carlo based approaches

We perform first-principle calculations of electron-nucleus scattering on 3 He and 3 H using the Green's function Monte Carlo method and two approaches based on the factorization of the final hadronic state: the spectral-function formalism and the short-time approximation. These three methods are benchmarked among each other and compared to the experimental data for the longitudinal and transverse electromagnetic response functions of 3 He, and the inclusive cross sections of both 3 He and 3 H. Since these three approaches are based on the same description of nuclear dynamics of the initial target state, comparing their results enables a precise quantification of the uncertainties inherent to factorization schemes. At sufficiently large values of the momentum transfer, we find an excellent agreement of the Green's function Monte Carlo calculation with experimental data and with both the spectral-function formalism and the short-time approximation. Here, we also analyze the relevance of relativistic effects, whose inclusion becomes crucial to explain data at high momentum and energy transfer.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electron scattering on ${\mathbf{A=3}}$ nuclei from quantum Monte Carlo based approaches

We perform first-principle calculations of electron-nucleus scattering on $^3$He and $^3$H using the Green's function Monte Carlo method and two approaches based on the factorization of the final hadronic state: the spectral-function formalism and the short-time approximation. These three methods are benchmarked among each other and compared to the experimental data for the longitudinal and transverse electromagnetic response functions of $^3$He, and the inclusive cross sections of both $^3$He and $^3$H. Since these three approaches are based on the same description of nuclear dynamics of the initial target state, comparing their results enables a precise quantification of the uncertainties inherent to factorization schemes. At sufficiently large values of the momentum transfer, we find an excellent agreement of the Green's function Monte Carlo calculation with experimental data and with both the spectral-function formalism and the short-time approximation. We also analyze the relevance of relativistic effects, whose inclusion becomes crucial to explain data at high momentum and energy transfer.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Review on Quantitative Multiplexed Proteomics

Over the last few decades, mass spectrometry-based proteomics has become an increasingly powerful tool that is now able to routinely detect and quantify thousands of proteins. A major advance for global protein quantification was the introduction of isobaric tags, which in a single experiment enable the global quantification of proteins across multiple samples. We refer to these methods as multiplexed proteomics. We discuss the principles, advantages, and drawbacks of various multiplexed proteomics techniques, and compare them to alternative approaches. We discuss how the emerging combination of multiplexing with targeted proteomics might enable the reliable and high-quality quantification of very low-abundance proteins across multiple conditions. We suggest that fusing multiplexed proteomics with data-independent acquisition approaches might enable the comparison of hundreds of different samples without missing values while maintaining the superb measurement precision and accuracy obtainable with isobaric tag quantification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Post-Landing Major Element Quantification Using SuperCam Laser Induced Breakdown Spectroscopy

The SuperCam instrument on the PerseveranceMars 2020 rover uses a pulsed 1064 nm laser to ablate targets at a distance and conduct laser induced breakdown spectroscopy (LIBS) by analyzing the light from the resulting plasma. SuperCam LIBS spectra are preprocessed to remove ambient light, noise, and the continuum signal present in LIBS observations. Prior to quantification, spectra are masked to remove noisier spectrometer regions andspectra are normalized to minimize signal fluctuations and effectsof target distance.In some cases, the spectra are also standardized or binned prior to quantification. To determine quantitative elemental compositionsof diverse geologic materials at Jezero crater, Mars, we use a suite of 1198 laboratory spectra of 334 well-characterized reference samples. The samples were selected to span a wide range of compositions and include typical silicate rocks, pure minerals (e.g.,silicates, sulfates, carbonates, oxides),more unusual compositions (e.g.,Mn oreand sodalite), andreplicates of the sintered SuperCam calibration targets (SCCTs) onboardthe rover. For each major element (SiO2, TiO2, Al2O3, FeOT, MgO, CaO, Na2O, K2O), the database was subdivided into five“folds” with similar distributions of the element of interest. One fold was held out as an independent test set, and the remaining fourfolds were used to optimize multivariate regression models relating the spectrum to the composition. We considered a variety of models, and selected several for further investigation for each element, based primarily on the root mean squared error of prediction (RMSEP) on the test set, when analyzed at 3m. In cases with several models of comparable performance at 3 m, we incorporated the SCCT performance at different distances to choose the preferred model. Shortly after landing on Mars and collecting initial spectra of geologic targets, we selected one model per element. Subsequently, with additional data from geologic targets, some models were revised to ensure results that are more consistent with geochemical constraints. The calibration discussed here is a snapshot of an ongoing effort to deliver the most accurate chemical compositions with SuperCam LIBS.

Mars 2020↗

Dosimetric evaluation of MapCHECK 2 and 3DVH in the IMRT delivery quality assurance process

Based on per-field data, 3 dose-volume histogram (DVH) is designed to calculate 3-dimensional (3D) dose using patient-computed tomography (CT) for an intensity-modulated radiation therapy (IMRT) delivery quality assurance (DQA) process measured with diode detector arrays. In this study, the characteristics and suitability of 3DVH for an IMRT DQA process were evaluated by assessment of clinically applied results. The DQA plans were prepared with a 2D diode detector array (MapCHECK 2) for 20 IMRT patients (10 with head and neck cancer and 10 with prostate cancer), and the matching rate between the calculated dose and the measured dose was analyzed. The relative dose differences between the original IMRT plan and the recalculated plan by 3DVH were evaluated for tumor target and organs at risk (OARs). Confidence limits (CLs) were determined for quantification of the degree of agreement that should be expected in each DQA method. The individual CLs for DQA accuracy of 3D dosimetric evaluation in the tumor target and OARs were also calculated to evaluate the differences compared with conventional 2D-based DQA results. The matching rates were sufficient to validate the accuracy of IMRT DQA analyses and the calculated CL values were reasonable values considering the normal criteria of our institution. The 3DVH analysis generally had better matching rate than per-field measurement analysis and the CL values for OARs were better than those for the planning target volume (PTV). The usefulness of the 3DVH tool was verified for IMRT DQA from the point of view of dose evaluation in the corresponding patient's CT data. It also enables dosimetric evaluation in each important structure (PTV and OARs), which can promote more effective evaluation of DQA error in terms of tumor treatment and side effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

Post-landing major element quantification using SuperCam laser induced breakdown spectroscopy

The SuperCam instrument on the Perseverance Mars 2020 rover uses a pulsed 1064 nm laser to ablate targets at a distance and conduct laser induced breakdown spectroscopy (LIBS) by analyzing the light from the resulting plasma. SuperCam LIBS spectra are preprocessed to remove ambient light, noise, and the continuum signal present in LIBS observations. Prior to quantification, spectra are masked to remove noisier spectrometer regions and spectra are normalized to minimize signal fluctuations and effects of target distance. In some cases, the spectra are also standardized or binned prior to quantification. To determine quantitative elemental compositions of diverse geologic materials at Jezero crater, Mars, we use a suite of 1198 laboratory spectra of 334 well-characterized reference samples. The samples were selected to span a wide range of compositions and include typical silicate rocks, pure minerals (e.g., silicates, sulfates, carbonates, oxides), more unusual compositions (e.g., Mn ore and sodalite), and replicates of the sintered SuperCam calibration targets (SCCTs) onboard the rover. For each major element (SiO 2 , TiO 2 , Al 2 O 3 , FeO T , MgO, CaO, Na 2 O, K 2 O), the database was subdivided into five “folds” with similar distributions of the element of interest. One fold was held out as an independent test set, and the remaining four folds were used to optimize multivariate regression models relating the spectrum to the composition. We considered a variety of models, and selected several for further investigation for each element, based primarily on the root mean squared error of prediction (RMSEP) on the test set, when analyzed at 3 m. In cases with several models of comparable performance at 3 m, we incorporated the SCCT performance at different distances to choose the preferred model. Shortly after landing on Mars and collecting initial spectra of geologic targets, we selected one model per element. Subsequently, with additional data from geologic targets, some models were revised to ensure results that are more consistent with geochemical constraints. The calibration discussed here is a snapshot of an ongoing effort to deliver the most accurate chemical compositions with SuperCam LIBS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mercury speciation using microcolumns with a direct mercury analyzer (DMA). Development of analytical method for the Savannah River Site liquid system

Mercury in the Savannah River Site (SRS) Liquid Waste System (LWS) exists in various forms, including: a) ionic inorganic mercury, organomercury (e.g., methyl Hg), and other less abundant species dissolved in LWS fluids, b) mercury solids such as oxides, hydroxides, amalgams, sulfides, and sorbed mercury, c) accumulations of dense liquid elemental mercury, and d) vapor phase elemental and organomercury mercury in tank headspace gas and in evaporators. Strategic and proactive management of the estimated 60,000 Kg mercury in the LWS requires deployment of efficient and effective paradigms for sampling and analysis of the total quantity of mercury in the various physical-chemical forms. Scoping tests of selective gas-phase sorbents for mercury speciation were performed to support LWS objectives. This research specifically focused on developing and testing streamlined methods to obtain high-quality analytical results for gaseous mercury species. The proposed methods are straightforward, using small columns (microcolumns) filled with materials that selectively sorb one or more target forms of mercury. Simple differentiation of mercury species and quantification is then achieved using an efficient thermal-desorption-based total mercury analyzer as the final step. Benefits associated with transitioning from multistep procedures such as EPA Methods 245.1, 1630 and 1631to streamlined microcolumn approaches include reduced analysis time, labor, and waste generation. Such transitioning would maximize the value of the current deployment of direct mercury analysis (EPA Method 7473) at SRS. This work has two target end uses: 1) simplifying the analysis steps and reducing costs for liquid samples (e.g., developing a total organic mercury (TOM) method), and 2) providing options for high-quality onsite analysis and rapid turnaround for gas samples in support of SRS LWS industrial hygiene (IH) objectives.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-618: Plan Robustness Study of Volumetric-Modulated Arc Therapy Vs. Intensity-Modulated Radiation Therapy for Head and Neck Cancer

Purpose: Lack of plan robustness may contribute to local failure in volumetric-modulated arc therapy (VMAT) to treat head and neck (H&N) cancer. Thus we compared plan robustness of VMAT with intensity-modulated radiation therapy (IMRT). Methods: VMAT and IMRT plans were created for 9 H&N cancer patients. For each plan, six new perturbed dose distributions were computed — one each for ± 3mm setup deviations along the S-I, A-P and L-R directions. We used three robustness quantification tools: (1) worst-case analysis (WCA); (2) dose-volume histograms (DVHs) band (DVHB); and (3) root-mean-square-dose deviation (RMSD) volume histogram (DDVH). DDVH represents the relative volume (y) on the vertical axis and the RMSD (x) on the horizontal axis. Similar to DVH, this means that y% of the volume of the indicated structure has the RMSD at least x Gy[RBE].The width from the first two methods at different target DVH indices (such as D95 and D5) and the area under the DDVH curves (AUC) for the target were used to indicate plan robustness. In these robustness quantification tools, the smaller the value, the more robust the plan is. Plan robustness evaluation metrics were compared using Wilcoxon test. Results: DVHB showed the width at D95 from IMRT to be larger than from VMAT (unit Gy) [1.59 vs 1.18 (p=0.49)], while the width at D5 from IMRT was found to be slightly larger than from VMAT [0.59 vs 0.54 (p=0.84)]. WCA showed similar results [D95: 3.28 vs 3.00 (p=0.56); D5: 1.68 vs 1.95 (p=0.23)]. DDVH showed the AUC from IMRT to be slightly smaller than from VMAT [1.13 vs 1.15 (p=0.43)]. Conclusion: VMAT plan robustness is comparable to IMRT plan robustness. The plan robustness conclusions from WCA and DVHB are DVH parameter dependent. On the other hand DDVH captures the overall effect of uncertainties on the dose to a volume of interest. NIH/NCI K25CA168984; Eagles Cancer Research Career Development; The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research Mayo ASU Seed Grant; The Kemper Marley Foundation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Updating Fission Yield Data for Applications (Summary Report)

The First Research Coordination Meeting of the CRP on “Updating Fission Yield Data for Applications” was held by video conference from 31 August to 4 September 2020 with more than 50 international experts from 16 countries attending the meeting. The CRP is devoted to evaluation efforts of cumulative and independent fission yields for incident energies from the thermal point up to 14 MeV on actinide targets. Produced fission yield evaluations should include full uncertainty quantification and are expected to combine available experimental data and state-of-art model information. Four working groups were created within the collaboration: 1) Availability of experimental fission product yield data for evaluations; 2) New fission product yield experimental data; 3) Fission product yield evaluation; and 4) Fission product yield validation. Technical discussions and the resulting work plan of the Coordinated Research Programme are summarized in this report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Summary Report of the 1st RCM of the CRP on the Updating Fission Yield Data for Applications

The First Research Coordination Meeting of the CRP on “Updating Fission Yield Data for Applications” was held by video conference from 31 August to 4 September 2020 with more than 50 international experts from 16 countries attending the meeting. The CRP is devoted to evaluation efforts of cumulative and independent fission yields for incident energies from the thermal point up to 14 MeV on actinide targets. Produced fission yield evaluations should include full uncertainty quantification and are expected to combine available experimental data and state-of-art model information. Four working groups were created within the collaboration: 1) Availability of experimental fission product yield data for evaluations; 2) New fission product yield experimental data; 3) Fission product yield evaluation; and 4) Fission product yield validation. Technical discussions and the resulting work plan of the Coordinated Research Programme are summarized in this report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗