Search NASA⌕ Search

SEARCH · Search NASA

Results for “targeted quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Electron scattering on A = 3 nuclei from quantum Monte Carlo based approaches

We perform first-principle calculations of electron-nucleus scattering on 3 He and 3 H using the Green's function Monte Carlo method and two approaches based on the factorization of the final hadronic state: the spectral-function formalism and the short-time approximation. These three methods are benchmarked among each other and compared to the experimental data for the longitudinal and transverse electromagnetic response functions of 3 He, and the inclusive cross sections of both 3 He and 3 H. Since these three approaches are based on the same description of nuclear dynamics of the initial target state, comparing their results enables a precise quantification of the uncertainties inherent to factorization schemes. At sufficiently large values of the momentum transfer, we find an excellent agreement of the Green's function Monte Carlo calculation with experimental data and with both the spectral-function formalism and the short-time approximation. Here, we also analyze the relevance of relativistic effects, whose inclusion becomes crucial to explain data at high momentum and energy transfer.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electron scattering on ${\mathbf{A=3}}$ nuclei from quantum Monte Carlo based approaches

We perform first-principle calculations of electron-nucleus scattering on $^3$He and $^3$H using the Green's function Monte Carlo method and two approaches based on the factorization of the final hadronic state: the spectral-function formalism and the short-time approximation. These three methods are benchmarked among each other and compared to the experimental data for the longitudinal and transverse electromagnetic response functions of $^3$He, and the inclusive cross sections of both $^3$He and $^3$H. Since these three approaches are based on the same description of nuclear dynamics of the initial target state, comparing their results enables a precise quantification of the uncertainties inherent to factorization schemes. At sufficiently large values of the momentum transfer, we find an excellent agreement of the Green's function Monte Carlo calculation with experimental data and with both the spectral-function formalism and the short-time approximation. We also analyze the relevance of relativistic effects, whose inclusion becomes crucial to explain data at high momentum and energy transfer.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Review on Quantitative Multiplexed Proteomics

Over the last few decades, mass spectrometry-based proteomics has become an increasingly powerful tool that is now able to routinely detect and quantify thousands of proteins. A major advance for global protein quantification was the introduction of isobaric tags, which in a single experiment enable the global quantification of proteins across multiple samples. We refer to these methods as multiplexed proteomics. We discuss the principles, advantages, and drawbacks of various multiplexed proteomics techniques, and compare them to alternative approaches. We discuss how the emerging combination of multiplexing with targeted proteomics might enable the reliable and high-quality quantification of very low-abundance proteins across multiple conditions. We suggest that fusing multiplexed proteomics with data-independent acquisition approaches might enable the comparison of hundreds of different samples without missing values while maintaining the superb measurement precision and accuracy obtainable with isobaric tag quantification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dosimetric evaluation of MapCHECK 2 and 3DVH in the IMRT delivery quality assurance process

Based on per-field data, 3 dose-volume histogram (DVH) is designed to calculate 3-dimensional (3D) dose using patient-computed tomography (CT) for an intensity-modulated radiation therapy (IMRT) delivery quality assurance (DQA) process measured with diode detector arrays. In this study, the characteristics and suitability of 3DVH for an IMRT DQA process were evaluated by assessment of clinically applied results. The DQA plans were prepared with a 2D diode detector array (MapCHECK 2) for 20 IMRT patients (10 with head and neck cancer and 10 with prostate cancer), and the matching rate between the calculated dose and the measured dose was analyzed. The relative dose differences between the original IMRT plan and the recalculated plan by 3DVH were evaluated for tumor target and organs at risk (OARs). Confidence limits (CLs) were determined for quantification of the degree of agreement that should be expected in each DQA method. The individual CLs for DQA accuracy of 3D dosimetric evaluation in the tumor target and OARs were also calculated to evaluate the differences compared with conventional 2D-based DQA results. The matching rates were sufficient to validate the accuracy of IMRT DQA analyses and the calculated CL values were reasonable values considering the normal criteria of our institution. The 3DVH analysis generally had better matching rate than per-field measurement analysis and the CL values for OARs were better than those for the planning target volume (PTV). The usefulness of the 3DVH tool was verified for IMRT DQA from the point of view of dose evaluation in the corresponding patient's CT data. It also enables dosimetric evaluation in each important structure (PTV and OARs), which can promote more effective evaluation of DQA error in terms of tumor treatment and side effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

Post-landing major element quantification using SuperCam laser induced breakdown spectroscopy

The SuperCam instrument on the Perseverance Mars 2020 rover uses a pulsed 1064 nm laser to ablate targets at a distance and conduct laser induced breakdown spectroscopy (LIBS) by analyzing the light from the resulting plasma. SuperCam LIBS spectra are preprocessed to remove ambient light, noise, and the continuum signal present in LIBS observations. Prior to quantification, spectra are masked to remove noisier spectrometer regions and spectra are normalized to minimize signal fluctuations and effects of target distance. In some cases, the spectra are also standardized or binned prior to quantification. To determine quantitative elemental compositions of diverse geologic materials at Jezero crater, Mars, we use a suite of 1198 laboratory spectra of 334 well-characterized reference samples. The samples were selected to span a wide range of compositions and include typical silicate rocks, pure minerals (e.g., silicates, sulfates, carbonates, oxides), more unusual compositions (e.g., Mn ore and sodalite), and replicates of the sintered SuperCam calibration targets (SCCTs) onboard the rover. For each major element (SiO 2 , TiO 2 , Al 2 O 3 , FeO T , MgO, CaO, Na 2 O, K 2 O), the database was subdivided into five “folds” with similar distributions of the element of interest. One fold was held out as an independent test set, and the remaining four folds were used to optimize multivariate regression models relating the spectrum to the composition. We considered a variety of models, and selected several for further investigation for each element, based primarily on the root mean squared error of prediction (RMSEP) on the test set, when analyzed at 3 m. In cases with several models of comparable performance at 3 m, we incorporated the SCCT performance at different distances to choose the preferred model. Shortly after landing on Mars and collecting initial spectra of geologic targets, we selected one model per element. Subsequently, with additional data from geologic targets, some models were revised to ensure results that are more consistent with geochemical constraints. The calibration discussed here is a snapshot of an ongoing effort to deliver the most accurate chemical compositions with SuperCam LIBS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mercury speciation using microcolumns with a direct mercury analyzer (DMA). Development of analytical method for the Savannah River Site liquid system

Mercury in the Savannah River Site (SRS) Liquid Waste System (LWS) exists in various forms, including: a) ionic inorganic mercury, organomercury (e.g., methyl Hg), and other less abundant species dissolved in LWS fluids, b) mercury solids such as oxides, hydroxides, amalgams, sulfides, and sorbed mercury, c) accumulations of dense liquid elemental mercury, and d) vapor phase elemental and organomercury mercury in tank headspace gas and in evaporators. Strategic and proactive management of the estimated 60,000 Kg mercury in the LWS requires deployment of efficient and effective paradigms for sampling and analysis of the total quantity of mercury in the various physical-chemical forms. Scoping tests of selective gas-phase sorbents for mercury speciation were performed to support LWS objectives. This research specifically focused on developing and testing streamlined methods to obtain high-quality analytical results for gaseous mercury species. The proposed methods are straightforward, using small columns (microcolumns) filled with materials that selectively sorb one or more target forms of mercury. Simple differentiation of mercury species and quantification is then achieved using an efficient thermal-desorption-based total mercury analyzer as the final step. Benefits associated with transitioning from multistep procedures such as EPA Methods 245.1, 1630 and 1631to streamlined microcolumn approaches include reduced analysis time, labor, and waste generation. Such transitioning would maximize the value of the current deployment of direct mercury analysis (EPA Method 7473) at SRS. This work has two target end uses: 1) simplifying the analysis steps and reducing costs for liquid samples (e.g., developing a total organic mercury (TOM) method), and 2) providing options for high-quality onsite analysis and rapid turnaround for gas samples in support of SRS LWS industrial hygiene (IH) objectives.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-618: Plan Robustness Study of Volumetric-Modulated Arc Therapy Vs. Intensity-Modulated Radiation Therapy for Head and Neck Cancer

Purpose: Lack of plan robustness may contribute to local failure in volumetric-modulated arc therapy (VMAT) to treat head and neck (H&N) cancer. Thus we compared plan robustness of VMAT with intensity-modulated radiation therapy (IMRT). Methods: VMAT and IMRT plans were created for 9 H&N cancer patients. For each plan, six new perturbed dose distributions were computed — one each for ± 3mm setup deviations along the S-I, A-P and L-R directions. We used three robustness quantification tools: (1) worst-case analysis (WCA); (2) dose-volume histograms (DVHs) band (DVHB); and (3) root-mean-square-dose deviation (RMSD) volume histogram (DDVH). DDVH represents the relative volume (y) on the vertical axis and the RMSD (x) on the horizontal axis. Similar to DVH, this means that y% of the volume of the indicated structure has the RMSD at least x Gy[RBE].The width from the first two methods at different target DVH indices (such as D95 and D5) and the area under the DDVH curves (AUC) for the target were used to indicate plan robustness. In these robustness quantification tools, the smaller the value, the more robust the plan is. Plan robustness evaluation metrics were compared using Wilcoxon test. Results: DVHB showed the width at D95 from IMRT to be larger than from VMAT (unit Gy) [1.59 vs 1.18 (p=0.49)], while the width at D5 from IMRT was found to be slightly larger than from VMAT [0.59 vs 0.54 (p=0.84)]. WCA showed similar results [D95: 3.28 vs 3.00 (p=0.56); D5: 1.68 vs 1.95 (p=0.23)]. DDVH showed the AUC from IMRT to be slightly smaller than from VMAT [1.13 vs 1.15 (p=0.43)]. Conclusion: VMAT plan robustness is comparable to IMRT plan robustness. The plan robustness conclusions from WCA and DVHB are DVH parameter dependent. On the other hand DDVH captures the overall effect of uncertainties on the dose to a volume of interest. NIH/NCI K25CA168984; Eagles Cancer Research Career Development; The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research Mayo ASU Seed Grant; The Kemper Marley Foundation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Updating Fission Yield Data for Applications (Summary Report)

The First Research Coordination Meeting of the CRP on “Updating Fission Yield Data for Applications” was held by video conference from 31 August to 4 September 2020 with more than 50 international experts from 16 countries attending the meeting. The CRP is devoted to evaluation efforts of cumulative and independent fission yields for incident energies from the thermal point up to 14 MeV on actinide targets. Produced fission yield evaluations should include full uncertainty quantification and are expected to combine available experimental data and state-of-art model information. Four working groups were created within the collaboration: 1) Availability of experimental fission product yield data for evaluations; 2) New fission product yield experimental data; 3) Fission product yield evaluation; and 4) Fission product yield validation. Technical discussions and the resulting work plan of the Coordinated Research Programme are summarized in this report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Summary Report of the 1st RCM of the CRP on the Updating Fission Yield Data for Applications

The First Research Coordination Meeting of the CRP on “Updating Fission Yield Data for Applications” was held by video conference from 31 August to 4 September 2020 with more than 50 international experts from 16 countries attending the meeting. The CRP is devoted to evaluation efforts of cumulative and independent fission yields for incident energies from the thermal point up to 14 MeV on actinide targets. Produced fission yield evaluations should include full uncertainty quantification and are expected to combine available experimental data and state-of-art model information. Four working groups were created within the collaboration: 1) Availability of experimental fission product yield data for evaluations; 2) New fission product yield experimental data; 3) Fission product yield evaluation; and 4) Fission product yield validation. Technical discussions and the resulting work plan of the Coordinated Research Programme are summarized in this report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Summary Report of the 2nd RCM of the CRP on Updating Fission Yield Data for Applications

The Second Research Coordination Meeting of the IAEA Coordinated Research Project (CRP) on Updating Fission Yield Data for Applications was held in Vienna at the IAEA headquarters from 19 to 23 December 2022, with 23 international experts attending the meeting. The CRP is devoted to evaluation efforts of cumulative and independent fission yields for incident energies from the thermal point up to 14 MeV on actinide targets. Produced fission yield evaluations should include full uncertainty quantification and are expected to combine available experimental data and state-of-the-art model information. The activities undertaken within this CRP were reviewed including the assessment of newly measured data and ongoing evaluation efforts. Technical discussions and the resulting further work plan of this CRP are summarized in this report. The meeting presentations are available at: https://www-nds.iaea.org/index-meeting-crp/2RCM_FY/index.htm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

4-1BB Aptamer-Based Immunomodulation Enhances the Therapeutic Index of Radiation Therapy in Murine Tumor Models

Purpose: To report a novel strategy using oligonucleotide aptamers to 4-1BB as an alternate method for costimulation, and show that combinatorial therapy with radiation improves the therapeutic ratio over equivalent monoclonal antibodies. Methods and Materials: Subcutaneous 4T1 (mouse mammary carcinoma) tumors were established (approximately 100 mm{sup 3}), and a radiation therapy (RT) dose/fractionation schedule that optimally synergizes with 4-1BB monoclonal antibody (mAb) was identified. Comparable tumor control and animal survival was observed when either 4-1BB antibody or aptamer were combined with RT using models of breast cancer and melanoma (4T1 and B16-F10). Off-target CD8{sup +} T-cell toxicity was evaluated by quantification of CD8{sup +} T cells in livers and spleens of treated animals. Results: When combined with 4-1BB mAb, significant differences in tumor control were observed by varying RT dose and fractionation schedules. Optimal synergy between RT and 4-1BB mAb was observed at 5 Gy × 6. Testing 4-1BB mAb and aptamer independently using the optimal RT (5 Gy × 6 for 4T1/Balb/c and 12 Gy × 1 for B16/C57BL6J mouse models) revealed equivalent tumor control using 4-1BB aptamer and 4-1BB mAb. 4-1BB mAb, but not 4-1BB aptamer-treated animals, exhibited increased lymphocytic liver infiltrates and increased splenic and liver CD8{sup +} T cells. Conclusions: Radiation therapy synergizes with 4-1BB mAb, and this effect is dependent on RT dose and fractionation. Tumor control by 4-1BB aptamer is equivalent to 4-1BB mAb when combined with optimal RT dose, without eliciting off-target liver and spleen CD8{sup +} expansion. 4-1BB aptamer-based costimulation affords a comparable and less toxic strategy to augment RT-mediated tumor control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of Uncertainty Quantification for Reactor Physics

The quantification of uncertainties is a crucial step in design. The comparison of a-priori uncertainties with the target accuracies, allows to define needs and priorities for uncertainty reduction. In view of their impact, the uncertainty analysis requires a reliability assessment of the uncertainty data used. The choice of the appropriate approach and the consistency of different approaches are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recommendations for the generation, quantification, storage and handling of peptides used for mass spectrometry-based assays

The Clinical Proteomic Tumor Analysis Consortium (1) (CPTAC) of the National Cancer Institute (NCI) is a comprehensive and coordinated effort to accelerate the understanding of the molecular basis of cancer through the application of robust technologies and workflows for the quantitative measurements of proteins. The Assay Development Working Group of the CPTAC Program aims to foster broad uptake of targeted mass spectrometry-based assays employing isotopically labeled peptides for confident assignment and quantification, including multiple reaction monitoring (MRM; also referred to as Selected Reaction Monitoring), parallel reaction monitoring (PRM), and other targeted methods.

Environmental Molecular Sciences Laboratory↗

Confirmation and Quantification of Gas Flow into Capsules

Inertial confinement fusion experiments require a fuel filled target. At the National Ignition Facility (NIF), these targets are filled through a capsule fill tube assembly (CFTA). While fabricating these assemblies, it is possible to plug the fill tube with glue, which would render the CFTA and eventual target unusable. Historically, this plugging was first detectable in a finished target after considerable resources had been expended. Herein, this paper presents a method for not only detecting a plug in the fill tube before the CFTA is assembled into a target, but also characterizing gas flow through the fill tube, which can help NIF operations prepare to expend each target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recommended Nuclear Data for the Production of Selected Therapeutic Radionuclides

Increasing interest in the treatment of human disease by means of targeted radionuclide-based therapies requires an accurate understanding of achievable yields and quantification of realisable degrees of purity. Important studies within a more extensive Coordinated Research Project of the International Atomic Energy Agency (IAEA CRP) have included in-depth assessments and evaluations of all available measured cross-section data for ten nuclear reactions leading to the formation of 131 Cs, 131 Ba, 225 Ac, 225 Ra, 227 Th, 227 Ac, 230 U and 230 Pa for various on-going and proposed therapeutic applications in nuclear medicine. Equivalent studies were also undertaken of possible reactions to produce the 178W /low-spin 178m Ta generator system that has been clinically applied in diagnosis by means of SPECT - these particular cross-section studies and recommendations are included in this paper for completeness. All available measured data have been critically reviewed and assessed to produce statistically consistent datasets. Selected datasets have been fitted by a least-squares method with Padé approximations of variable order to evaluate the production cross sections and corresponding uncertainties. New measurements have been made in some instances, and reported data have been adjusted to accommodate new nuclear decay or monitor reaction data which altered the original reported quantities adversely. Insufficient measured data are available in many cases to permit a reliable evaluation of cross sections, and these instances are discussed. Finally, recommended therapeutic radionuclide production reaction data and their uncertainties are available on the Web page of the IAEA Nuclear Data Section at www-nds.iaea.org/radionuclides/ and also at the IAEA medical portal www-nds.iaea.org/medportal/.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Probabilistic-learning-based stochastic surrogate model from small incomplete datasets for nonlinear dynamical systems

We consider a high-dimensional nonlinear computational model of a dynamical system, parameterized by a vector-valued control parameter, in the presence of uncertainties represented by an uncontrolled parameter modeled by a vector-valued random variable, and possibly with stochastic excitation. The objective is to construct a statistical surrogate model where the input is any deterministic value of the control parameter, and the output is a vector-valued observation of the computational model, which is a random vector whose probability measure is updated using a target dataset. To construct this statistical surrogate model, the stochastic response of the computational model must be built, which is a vector-valued time-discretized stochastic process in high dimension, depending on the control parameter. It is assumed that the computational cost of a single evaluation of the deterministic model is high. For the probabilistic updating, we consider a subset of the components of the observation of the computational model, defined as the “identification observation” of the computational model, for which a small target dataset is available. Therefore, the target dataset is associated with partial observability, corresponding to an incomplete data case. Given a prior probability model of the random control and uncontrolled parameters, a training dataset is constructed, consisting of realizations of the random triplet composed of the stochastic response, the random identification observation, and the random control parameter. Since the computational cost of a single evaluation of the deterministic model is assumed to be large, the training dataset is also of small size. The main challenges in this problem are the high dimensionality, partial observability leading to incomplete data in the target dataset for the identification observation of the computational model (which is not sufficient to identify the computational stochastic responses), and the availability of a small training dataset. To address these challenges, we propose a methodology based on statistical methods for constructing necessary reduced representations, direct probabilistic learning under constraints using probabilistic learning on manifolds (PLoM) constrained by the target dataset, and the use of a weak formulation of the Fourier transform of probability measures. Statistical conditioning is also employed to explore the learned dataset. The constructed predictive statistical surrogate model can be implemented in the context of online computation. Here, we apply this approach to a problem of nonlinear stochastic dynamics in high dimensions within the framework of deformable solids mechanics.

Engineering↗

Calibration and Forward Uncertainty Propagation for Large-eddy Simulations of Engineering Flows

The objective of this work is to investigate the efficacy of using calibration strategies from Uncertainty Quantification (UQ) to determine model coefficients for LES. As the target methods are for engineering LES, uncertainty from numerical aspects of the model must also be quantified. 15 The ultimate goal of this research thread is to generate a cost versus accuracy curve for LES such that the cost could be minimized given an accuracy prescribed by an engineering need. Realization of this goal would enable LES to serve as a predictive simulation tool within the engineering design process.

42 ENGINEERING↗

A refined assessment of nuclear data target accuracy requirements for ALFRED

The interest in target accuracy assessment has been recently renewed within the OECD/NEA Working Party on International Nuclear Data Evaluation Cooperation with an update exercise, thanks to the invaluable initiative of Massimo Salvatores. This work, moving from evaluations on the main core integral parameters of the Advanced Lead-cooled Fast Reactor European Demonstrator (ALFRED), and the identification of the associated target accuracies needed for improving its design, approaches the retrieval of target accuracy requirements for nuclear data, as the inverse problem of uncertainty quantification. The preliminary results obtained in a previous work are here refined by explicitly taking into account the total contribution due to correlations among variables in the optimization constraint, while its various components are evaluated individually. Moreover, three different sets of cost parameters are considered to introduce a bias in the solution in order to take in due account the relative difficulties in the execution of new differential experiments as needed for achieving the proposed target accuracies. By this, the obtained results are deemed usefully informative, and proposed for the update of a High Priority List which identifies the isotopes-reaction couples of most interest for future refinement experiments, especially when integrated with further analogous information collected on other advanced nuclear systems. Among the cross-sections whose refinement contributes the most to the reduction of the multiplication factor, the fission of Pu{sup 239} was found, which needs to be fixed below 1% in the range of interest for ALFRED (2 keV-4 MeV). Another contribution for the amelioration of the multiplication factor calculation accuracy, is due to the capture channel of Pu{sup 239}, for which the initial high uncertainty (around 15%) can be significantly reduced resorting to easily practicable experiments. The same occurs for the inelastic of Pb{sup 207}, for which the initial uncertainty value of around 50% can be drastically reduced up to target values between 4% and 7%.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗