Water-Cooled Total-Temperature Probe

Water-cooled supersonic total-pressure, static-pressure, and total-temperature probes developed to study high-temperature jet plumes. Total-temperature probe tested up to 2,000 degrees F incorporates annular cooling system up to thermocouple lead. Lead extends into test chamber to sense temperature of supersonic external flow. Design novel and significant. Applicable in development of jet engines and in research on fast flows of hot gases.

Lagen, Nicholas T.↗

A Temperature Sensor using a Silicon-on-Insulator (SOI) Timer for Very Wide Temperature Measurement

A temperature sensor based on a commercial-off-the-shelf (COTS) Silicon-on-Insulator (SOI) Timer was designed for extreme temperature applications. The sensor can operate under a wide temperature range from hot jet engine compartments to cryogenic space exploration missions. For example, in Jet Engine Distributed Control Architecture, the sensor must be able to operate at temperatures exceeding 150 C. For space missions, extremely low cryogenic temperatures need to be measured. The output of the sensor, which consisted of a stream of digitized pulses whose period was proportional to the sensed temperature, can be interfaced with a controller or a computer. The data acquisition system would then give a direct readout of the temperature through the use of a look-up table, a built-in algorithm, or a mathematical model. Because of the wide range of temperature measurement and because the sensor is made of carefully selected COTS parts, this work is directly applicable to the NASA Fundamental Aeronautics/Subsonic Fixed Wing Program--Jet Engine Distributed Engine Control Task and to the NASA Electronic Parts and Packaging (NEPP) Program. In the past, a temperature sensor was designed and built using an SOI operational amplifier, and a report was issued. This work used an SOI 555 timer as its core and is completely new work.

Patterson, Richard L.↗

Thermal compensator for helium refrigerators

Closed-cycle helium refrigerator sensor generates negative-feedback control signals that drive heating diode to maintain temperature stability. Temperature-sensing diode and heating diode are mounted on heat sink that provides conductive path between load and cold tip. Method is applicable to other temperature-control applications, such as laser equipment, electronic instruments, and computer systems.

Hillman, J. J.↗

CFD Predictions of Boiling Regime Transitions during Line Chilldown validated against a 1G LN2 Experiment

Introduction Before filling a propellant tank on the ground or in Space, the transfer line between the donor and receiver tanks must be cooled down preferably by sacrificing a minimum amount of the cryogenic fluid. The cryogenic line chill-down process involves a transition between different flow boiling regimes, namely, film boiling, transition film boiling, and nucleate boiling which are complex and may be quite gravity-dependent. Capturing these boiling phenomena and predicting the transition between them in a CFD framework is new and challenging both for 1g and microgravity applications. Materials & Methods The present work addresses this challenge by employing a two-phase Eulerian approach in the context of a homogeneous fluid mixture together with the Lee phase change model to capture the film boiling regime of the chill-down process using ANSYS Fluent®. The nucleate boiling regime is predicted by incorporating an in-house developed sub-grid model that accounts for bubble nucleation, bubble growth, bubble departure diameter, and their shedding frequency. The sub-grid model is encoded and implemented into Fluent via a user-defined function for the wall-fluid heat flux calculations. The mathematical formulation and numerical implementation of the CFD model are described in detail. The coupled CFD-Subgrid model is validated against published experimental data for liquid nitrogen chill-down of a heated stainless-steel pipe in 1g. Results Numerical simulation results show good agreements between the CFD predictions of the wall temperature evolution, rewetting temperature, and transition between film and nucleate boiling, with the experimental measurements published by Darr et al [2] for several different LN2 flowrates in the vertical pipe orientation. The CFD predictions for the wall temperature distribution indicate a rapid quenching of the wall at two upstream and downstream temperature sensing locations as compared to the experimental measurement. The only tuning parameter in the CFD model is the Lee mass transfer coefficient. The CFD Model predicts the Liedenfrost rewetting temperature in close agreement with the experiment. This marks a transition between stable and transitionary flow boiling regimes. The CFD-predicted boiling curve for the downstream sensor location is also compared against its experimental counterpart and indicates that the model is able to predict all the key temperature and heat flux parameters during the transitions from stable to transitionary film boiling to nucleate boiling in close agreement with the experiment. A sequence of predicted volume fraction, and temperature contours depicting these transitions will be presented.

Evaporation Condensation↗

Wide-Range Temperature Sensors with High-Level Pulse Train Output

Two types of temperature sensors have been developed for wide-range temperature applications. The two sensors measure temperature in the range of -190 to +200 C and utilize a thin-film platinum RTD (resistance temperature detector) as the temperature-sensing element. Other parts used in the fabrication of these sensors include NPO (negative-positive- zero) type ceramic capacitors for timing, thermally-stable film or wirewound resistors, and high-temperature circuit boards and solder. The first type of temperature sensor is a relaxation oscillator circuit using an SOI (silicon-on-insulator) operational amplifier as a comparator. The output is a pulse train with a period that is roughly proportional to the temperature being measured. The voltage level of the pulse train is high-level, for example 10 V. The high-level output makes the sensor less sensitive to noise or electromagnetic interference. The output can be read by a frequency or period meter and then converted into a temperature reading. The second type of temperature sensor is made up of various types of multivibrator circuits using an SOI type 555 timer and the passive components mentioned above. Three configurations have been developed that were based on the technique of charging and discharging a capacitor through a resistive element to create a train of pulses governed by the capacitor-resistor time constant. Both types of sensors, which operated successfully over the wide temperature range, have potential use in extreme temperature environments including jet engines and space exploration missions.

Hammoud, Ahmad↗

Geographic variation in the relationships of temperature, salinity or sigma sub t versus plant nutrient concentrations in the world ocean

A NODC data set representing all regions of the world ocean was analyzed for temperature and sigma-t relationships with nitrate, phosphate or silicic acid. Six cubic regressions were for each ten degree square of latitude and longitude containing adequate data. World maps display the locations that allow the prediction of plant nutrient concentrations from temperature or sigma-t. Geographic coverage improves along the sequence: nitrate, phosphate, and silicic acid and is better for sigma-t than for temperature. Contour maps of the approximate temperature of sigma-t at which these nitrients are no longer measurable in a parcel of water are generated, based on a percentile analysis of the temperature or sigma-t at which less than a selected amount of plant nutrient occurs. Results are stored on magnetic tape in tabular form. The global potential to predict plant nutrient concentrations from remotely sensed temperature of sigma-t and to emphasize the latitudinally and longitudinally changing phytoplankton growth environment in present and past oceans is demonstrated.

Kamykowski, D.↗

Superconducting Effects in Optimization of Magnetic Penetration Thermometers for X-ray Microcalorimeters

We have made high resolution x-ray microcalorimeters using superconducting MoAu bilayers and Nb meander coils. The temperature sensor is a Magnetic Penetration Thermometer (MPT). Operation is similar to metallic magnetic calorimeters, but instead of the magnetic susceptibility of a paramagnetic alloy, we use the diamagnetic response of the superconducting MoAu to sense temperature changes in an x-ray absorber. Flux-temperature responsivtty can be large for small sensor heat capacity, with enough dynamic range for applications. We find models of observed flux-temperature curves require several effects to explain flux penetration or expulsion in the microscopic devices. The superconductor is non-local, with large coherence length and weak pinning of flux. At lowest temperatures, behavior is dominated by screening currents that vary as a result of the temperature dependence of the magnetic penetration depth, modified by the effect of the nonuniformity of the applied field occurring on a scale comparable to the coherence length. In the temperature regime where responslvity is greatest, spadal variations in the order parameter become important: both local variations as flux enters/leaves the film and an intermediate state is formed, and globally as changing stability of the electrical circuit creates a Meissner transition and flux is expelled/penetrates to minimize free energy.

Stevenson, Thomas R.↗

Health Sensing Functions in Thermal Barrier Coatings Incorporating Rare-Earth-Doped Luminescent Sublayers

Great effort has been directed towards developing techniques to monitor the health of thermal barrier coatings (TBCs) that would detect the approach of safety-threatening conditions. An unconventional approach is presented here where health sensing functionality is integrated into the TBC itself by the incorporation of rare-earth-doped luminescent sublayers to monitor erosion as well as whether the TBC is maintaining the underlying substrate at a sufficiently low temperature. Erosion indication is demonstrated in electron-beam physical vapor deposited (EB-PVD) TBCs consisting of 7wt% yttria-stabilized zirconia (7YSZ) with europium-doped and terbium-doped sublayers. Multiple ingot deposition produced sharp boundaries between the doped sublayers without interrupting the columnar growth of the TBC. The TBC-coated specimens were subjected to alumina particle jet erosion, and the erosion depth was then indicated under ultraviolet illumination that excited easily visible luminescence characteristic of sublayer that was exposed by erosion. In addition, temperature measurements from a bottom-lying europium-doped sublayer in a TBC produced by multiple ingot EB-PVD were accomplished by measuring the temperature-dependent decay time from the 606 nm wavelength emission excited in that sublayer with a 532 nm wavelength laser that was selected for its close match to one of the europium excitation wavelengths as well as being at a wavelength where the TBC is relatively transparent. It is proposed the low dopant levels and absence of interruption of the TBC columnar growth allow the addition of the erosion and temperature sensing functions with minimal effects on TBC performance.

Eldridge, J. I.↗

Effects of Coating and Diametric Load on Fiber Bragg Gratings as Cryogenic Temperature Sensors

Cryogenic temperature sensing was demonstrated using pressurized fiber Bragg gratings (PFBGs) with polymer coating of various thicknesses. The PFBG was obtained by applying a small diametric load to a regular fiber Bragg grating (FBG). The Bragg wavelengths of FBGs and PFBG were measured at temperatures from 295 K to 4.2 K. The temperature sensitivities of the FBGs were increased by the polymer coating. A physical model was developed to relate the Bragg wavelength shifts to the thermal expansion coefficients, Young's moduli, and thicknesses of the coating polymers. When a diametric load of no more than 15 N was applied to a FBG, a pressure-induced transition occurred at 200 K during the cooling cycle. The pressure induced transition yielded PFBG temperature sensitivities three times greater than conventional FBGs for temperatures ranging from 80 to 200 K, and ten times greater than conventional fibers for temperatures below 80 K. PFBGs were found to produce an increased Bragg wavelength shift of 2.2 nm compared to conventional FBGs over the temperature range of 4.2 to 300 K. This effect was independent of coating thickness and attributed to the change of the fiber thermo-optic coefficient.

Wu, meng-Chou↗

Implementation of an Ultra-Bright Thermographic Phosphor for Gas Turbine Engine Temperature Measurements

The overall goal of the Aeronautics Research Mission Directorate (ARMD) Seedling Phase II effort was to build on the promising temperature-sensing characteristics of the ultrabright thermographic phosphor Cr-doped gadolinium aluminum perovskite (Cr:GAP) demonstrated in Phase I by transitioning towards an engine environment implementation. The strategy adopted was to take advantage of the unprecedented retention of ultra-bright luminescence from Cr:GAP at temperatures over 1000 C to enable fast 2D temperature mapping of actual component surfaces as well as to utilize inexpensive low-power laser-diode excitation suitable for on-wing diagnostics. A special emphasis was placed on establishing Cr:GAP luminescence-based surface temperature mapping as a new tool for evaluating engine component surface cooling effectiveness.

temperature↗

Heat flux instrumentation for HYFLITE thermal protection system

Tasks performed in this project were defined in a September 9, 1994 meeting of representatives of Vatell, NASA Lewis and Virginia Tech. The overall objective agreed upon in the meeting was 'to demonstrate the viability of thin film techniques for heat flux and temperature sensing in HYSTEP thermal protection systems'. We decided to attempt a combination of NASA's and Vatell's best heat flux sensor technology in a sensor which would be tested in the Vortek facility at Lewis early in 1995. The NASA concept for thermocouple measurement of surface temperature was adopted, and Vatell methods for fabrication of sensors on small diameter substrates of aluminum nitride were used to produce a sensor. This sensor was then encapsulated in a NARloy-Z housing. Various improvements to the Vatell substrate design were explored without success. The basic NASA and Vatell sensor layouts were analyzed by finite element modeling, in an attempt to better understand the effects of material properties, dimensions and thermal differential element location on sensor symmetry, bandwidth and sensitivity. This analysis showed that, as long as the thermal resistivity of the thermal differential element material is much larger (10X) than that of the substrate material, the simplest arrangement of layer is best. During calibration of the sensor produced in this project, undesirable side-effects of combining the heat flux and temperature sensor return leads were observed. The sensor did not cleanly separate the heat flux and temperature signals, as sensors with four leads have consistently done before. Task 7 and 8 discussed in the meeting will be performed with a continuation of funding in 1995. The following is a discussion of each of the tasks performed as outlined in the statement of work dated september 26, 1994. Task 1A was added to cover further investigation into the NASA sensor concept.

Diller, T. E.↗

Remote sensing of chlorophyll and temperature in marine and fresh waters.

An airborne differential radiometer was demonstrated to be a sensitive, real-time detector of surface chlorophyll content in water bodies. The instrument continuously measures the difference in radiance between two wavelength bands, one centered near the maximum of the blue chlorophyll a absorption region and the other at a reference wavelength outside this region. Flights were made over fresh water lakes, marine waters, and an estuary, and the results were compared with 'ground truth' measurements of chlorophyll concentration. A correlation between output signal of the differential radiometer and the chlorophyll concentration was obtained. Examples of flight data are illustrated. Simultaneous airborne measurements of chlorophyll content and water temperature revealed that variations in chlorophyll are often associated with changes in temperature. Thus, simultaneous sensing of chlorophyll and temperature provides useful information for studies of marine food production, water pollution, and physical processes such as upwelling.

Arvesen, J. C.↗

University of Utah four-channel pulse-to-pulse commutated SUPER-LOKI rocket meteorological parachutesonde (electronics)

The electronics and temperature sensing units of the pulse-to-pulse rocketsonde are described. The sonde is designed for the 2 1/8-inch dart of the SUPER-LOKI meteorological rocket. In flight, the sonde descends by parachute from rocket apogees of about 75 kilometers. As the sonde descends, it transmits air temperature data back to ground radio receiving stations.

Atwood, K. W.↗

High-sensitivity cryogenic temperature sensors using pressurized fiber Bragg gratings

Cryogenic temperature sensing was studied using a pressurized fiber Bragg grating (PFBG). The PFBG was obtained by simply applying a small diametric load to a regular fiber Bragg grating (FBG), which was coated with polyimide of a thickness of 11 micrometers. The Bragg wavelength of the PFBG was measured at temperatures from 295 to 4.2 K. A pressure-induced transition occurred at 200 K during the cooling cycle. As a result the temperature sensitivity of the PFBG was found to be nonlinear but reach 24 pm/K below 200 K, more than three times the regular FBG. For the temperature change from 80 K to 10 K, the PFBG has a total Bragg wavelength shift of about 470 pm, 10 times more than the regular FBG. From room temperature to liquid helium temperature the PFBG gives a total wavelength shift of 3.78 nm, compared to the FBG of 1.51 nm. The effect of the coating thickness on the temperature sensitivity of the gratings is also discussed.

Wu, Meng-Chou↗

High-sensitivity Cryogenic Temperature Sensors using Pressurized Fiber Bragg Gratings

Cryogenic temperature sensing was studied using a pressurized fiber Bragg grating (PFBG). The PFBG was obtained by simply applying a small diametric load to a regular fiber Bragg grating (FBG), which was coated with polyimide of a thickness of 11 micrometers. The Bragg wavelength of the PFBG was measured at temperatures from 295 to 4.2 K. A pressure-induced transition occurred at 200 K during the cooling cycle. As a result the temperature sensitivity of the PFBG was found to be nonlinear but reach 24 pm/K below 200 K, more than three times the regular FBG. For the temperature change from 80 K to 10 K, the PFBG has a total Bragg wavelength shift of about 470 pm, 10 times more than the regular FBG. From room temperature to liquid helium temperature the PFBG gives a total wavelength shift of 3.78 nm, compared to the FBG of 1.51 nm. The effect of the coating thickness on the temperature sensitivity of the gratings is also discussed.

Wu, Meng-Chou↗

Single-Tip Probe Senses Pressure Or Temperature

Single-tip probe designed for use in supersonic wind tunnel switched to sense pressure or temperature measurements nearly simultaneous at that point. Includes small valve like valves used in bicycle and automotive tires, called "Schraeder valve". Tire valve opened or closed by push rod and solenoid. In open position, flow past thermocouple enables measurements of temperature. In closed position, flow blocked and pressure in probe backs up to pressure transducer.

Trimarchi, Paul↗

Threaded average temperature thermocouple

A threaded average temperature thermocouple 11 is provided to measure the average temperature of a test situs of a test material 30. A ceramic insulator rod 15 with two parallel holes 17 and 18 through the length thereof is securely fitted in a cylinder 16, which is bored along the longitudinal axis of symmetry of threaded bolt 12. Threaded bolt 12 is composed of material having thermal properties similar to those of test material 30. Leads of a thermocouple wire 20 leading from a remotely situated temperature sensing device 35 are each fed through one of the holes 17 or 18, secured at head end 13 of ceramic insulator rod 15, and exit at tip end 14. Each lead of thermocouple wire 20 is bent into and secured in an opposite radial groove 25 in tip end 14 of threaded bolt 12. Resulting threaded average temperature thermocouple 11 is ready to be inserted into cylindrical receptacle 32. The tip end 14 of the threaded average temperature thermocouple 11 is in intimate contact with receptacle 32. A jam nut 36 secures the threaded average temperature thermocouple 11 to test material 30.

Ward, Stanley W.↗