Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Thermal performance evaluation of Solar Energy Products Company (SEPCO) 'Soloron' collector tested outdoors

The test article, Model EF-212, Serial Nr. 002, is a single glazed collector with a nonselective absorber plate, using flowing air as the heat transfer medium. The absorber plate and box frame are aluminum and the insulation is one inch isocyanurate foam board with thermal conductivity of 0.11 (BTU/sq ft Hr0/ft.) The tests included the following. (1) time constant test, (2) collector efficiency test, (3) collector stagnation test, (4) incident angle modifier test, (5) load test, (6) weathering test, and (7) absorber plate optical properties test. The results of these tests are tabulated, graphed, or otherwise recorded.

Chiou, J., Sr.↗

Evaluation of thermal control surface on-orbit servicing methods for long term missions

Future activities of NASA will include the long-term (10 - 30 years) operation of space vehicles. For this reason, there will be an urgent need to provide the basic technology for space vehicle thermal control surfaces and their functional maintenance for future long-term missions. One of the problems arising in connection with such missions is related to contamination which can degrade operational design parameters of critical and thermal control surfaces. All Space Based Payloads will arrive on orbit with a certain level of contamination from ground handling, and, on orbit, will be subjected to some level of contamination over their mission life. For the extension of mission life, it appears practical to institute surface refurbishment procedures for contaminated and degraded surfaces. Potential resurfacing methods are evaluated, taking into account three potential processes. The most promising of these is a cleaning procedure based on the utilization of atomic oxygen.

Saylor, W.↗

Thermal performance evaluation of the Calmac (liquid) solar collector

The procedures used and the results obtained during the evaluation test program on the S. N. 1, (liquid) solar collector are presented. The flat plate collector uses water as the working fluid. The absorber plate is aluminum with plastic tubes coated with urethane black. The glazing consists of .040 in fiberglass reinforced polyester. The collector weight is 78.5 pounds with overall external dimensions of approximately 50.3in. x 98.3in. x 3.8in. The following information is given: thermal performance data under simulated conditions, structural behavior under static loading, and the effects of long term exposure to natural weathering. These tests were conducted using the MSFC Solar Simulator.

Usher, H.↗

Thermal performance evaluation of the Semco (liquid) solar collector

Procedures used and results obtained during the evaluation test program on a flat plate collector which uses water as the working fluid are discussed. The absorber plate is copper tube soldered to copper fin coated with flat black paint. The glazing consists of two plates of Lo-Iron glass; the insulation is polyurethane foam. The collector weight is 242.5 pounds with overall external dimensions of approximately 48.8 in. x 120.8 in. x 4.1 in. The test program was conducted to obtain thermal performance data before and after 34 days of weather exposure test.

Source record↗

High time service evaluation of thermal barrier coatings on the Rolls-Royce RB211 engine

One of the main concerns of airline operators for the use of thermal barrier coatings (TBC) in the turbine is that the coating will spall and cause a premature engine removal. Even though much cyclic data is available on TBCs, high time data is much harder and expensive to come by. The typical 150 h type test used to qualify hardware, or modifications, falls far short of the 5 to 10,000 hour experience desired. One way to obtain data demonstrating the longevity of TBCs is through a service evaluation program on a commercial engine. For a meaningful evaluation of the TBC system it must be applied to a component which operates in a typical hot end environment. In addition the component performance should not suffer if the coating is lost. For these reasons Rolls-Royce chose to coat the IP turbine nozzle guide vanes, and run these in an RB211 engine. Two ceramic top coats and several different bond coats were tested in a rainbow fashion on several engines. Three layer magnesium zirconate was used as a base line. Various yttria stabilized zirconia ceramics were used. Top MCrAlY bond coats were applied by various techniques. Some of the coated vanes have now accumulated ofer 5000 hours. The results are presented from the first sets with 2500 and 4200 hours of service respectively.

Toriz, F. Chris↗

Thermal performance evaluation of the Suncatcher SH-11 (liquid) solar collector

The procedures used and the results obtained during the evaluation test program on the Solar Unlimited, Inc., Suncatcher SH-11 (liquid) solar collector are presented. The flat-plate collector case assembly is made of .08 inch aluminum 3003 H14 riveted with fiberglass board insulation. The absorber consists of collared aluminum fins mechanically bonded to 3/8 inch copper tubing and coated with 3M Nextel black. Water is used as the working fluid. The glazing is made of a single glass, 1/8 inch water white, tempered and antireflective. The collector weight is 85 pounds with overall external dimensions of about 35.4 in x 82.0 in x 4.0 in. Thermal performance data on the Solar Unlimited Suncatcher SH-11 solar collector under simulated conditions were conducted using the MSFC Solar Simulator.

Source record↗

Evaluation of thermal loading on a methane injector at high pressure and temperature

Experimental and numerical analyses are conducted to determine the surface temperature on a methane fuel injector used to produce a high enthalpy test stream for a combustion-fed subscale wind tunnel facility. It was found that the ratio of the methane fuel injection velocity to the air stream velocity is a significant factor in the production of high injector surface temperatures which lead to rapid deterioration of the fuel injector structure. The numerical code utilized for the computational analysis was found to be representative of the experimentally measured data since the experimental trends were reproduced by the numerical simulation. The quantitative accuracy of the numerical predictions could not be assessed from the data gathered because of the difficulty of making a noninterfering injector surface temperature measurement. The numerical code can be used for parametric evaluation of combustor parameters and thus will serve as an important tool in the design of such fuel injector systems.

Harvin, Stephen F.↗

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance↗

Evaluation of thermal energy storage for central receiver concentrating solar power plants under charging cycles through structural assessment

Electricity production by concentrated solar power (CSP) systems has stood out among energy transition alternatives due to their large generation capacity (between 30 MW and 400 MW) and high capacity factor (80%) when incorporating thermal storage systems (TES). Although TES tanks in operation worldwide are made of austenitic steels with remarkable mechanical and anticorrosive properties, operational failures have been reported due to low-cycle fatigue, creep, and the abrupt release of residual stresses generated during tank manufacturing. A critical operation for salt tanks is the initial daily charging operation, given the low fluid level and the thermal gradients between the inventory and the salt entering the tank. This study presents a structural simulation of a 39.6 m-diameter molten salt tank for central receiver CSP plants, accounting for temperature and pressure variations during charging and different sparger ring inlet configurations. The initial pre-stressed condition of the floor, resulting from the manufacture of welded plates, is used as a boundary condition. The fatigue and creep life analyses were performed in accordance with the ASME BPVC and API standards. It was found that the tank's floor is in a less favourable mechanical condition than the wall, due to its initial manufacturing condition and the maximum temperature differences during charging. A critical zone was identified in an area affected by residual stress on the floor and under the sparger ring. The baseline sparger ring configuration, with 52 2-inch-diameter orifices and a flow direction of 90 degrees , results in an average floor stress of approximately 25 MPa and creep damage after 1.2 years of tank operation.

14 SOLAR ENERGY↗

Chrome-free qandilite (Mg 2 TiO 4 ) refractory aggregates: Role of titania source and evaluation of thermal expansion coefficient

As used chrome-based refractories may contain toxic Cr 6+ , the chrome-free Mg 2 TiO 4 phase is being considered which is known to improve hot strength and resistance to thermal shock and slag corrosion. As in situ Mg 2 TiO 4 formation generates porosity, preformed aggregates are desirable. Dilatometric studies revealed that when dead burned magnesia is combined with industrial anatase instead of rutile, it expanded less (1% versus 7.2%) and the reaction occurred earlier (965°C compared to 1120°C). After sintering at 1,600°C, rutile produced an aggregate with 3.8% open porosity, whereas anatase led to 0 % porosity and a bulk density of 3.24g/cm 3 with a thermal expansion coefficient (70–1,600°C) of 13.5×10 -6 K -1 . Moreover, replacing rutile by anatase eliminates the undesirable MgTiO 3 phase. The anatase-based aggregate consisted of a Mg 2 TiO 4 matrix with residual unreacted MgO and an intergranular, refractory CaTiO 3 phase. In conclusion, the rutile-based aggregate was deemed unsuitable due to a low-melting microstructure of forsterite contiguous with CaTiO 3 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

From phase decomposition to evaporation: A multi-modal evaluation of thermally degraded model lightweight high-entropy alloy

Lightweight high-entropy alloys (LHEAs) have the potential to replace conventional lightweight materials due to their superior mechanical properties and thermal stability. However, the thermal degradation pattern of LHEAs from phase decomposition to evaporation is not clear. We develop a new Al-based dual phase (FCC + HCP) LHEA—AlTi 0.45 CuZn, and further investigate its thermal degradation behavior for potential high-temperature structural applications. Using multimodal advanced characterization techniques such as differential scanning calorimetry/thermogravimetric analysis, scanning/transmission electron microscopy, and synchrotron X-ray diffraction/pair distribution function (XRD/PDF), a sequence of thermal degradation events beyond the thermal phase stability limit—between 250 and 360 °C—is observed. These include phase decomposition at ~360 °C, Zn evaporation at ~750 °C, and LHEA melting at 880 °C which results in ~25% cumulative weight loss. The formation of Al-Ti phase off the AlTi 0.45 CuZn matrix is due to the largest negative mixing enthalpy for Al-Ti than other binary pairs. Similarly, Zn evaporation from AlTi 0.45 CuZn LHEA is due to its faster evaporation rate than other constituent elements. The high-resolution synchrotron XRD and PDF results support the aforementioned observations; in addition, they reveal local atomic arrangements, local strain, and sluggish grain growth in the LHEA. Among other LHEAs of close density range (5.55 ≤ ρ ≤ 5.85 g/cc), the investigated LHEA exhibits outstanding nano-indentation hardness values due to the coupled grain size effect and HCP phase strengthening of the FCC matrix. As the search for LHEAs for lightweight applications grows, this study shows the potential use of AlTi 0.45 CuZn LHEA for structural applications even at elevated temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis and Evaluation of Thermally Annealed Pyrolytic Graphite Heat Spreader for Power Modules

Next generation power modules demand increased heat extraction capability along with reduced weight and volume. In this paper, thermally annealed pyrolytic graphite (TPG) is analyzed and compared with conventional materials used in power modules for thermal management. Fundamental properties of TPG are explained and compared with commonly used materials in power module heat spreaders and substrates. The encapsulated TPG based heat spreader is manufactured and compared with bulk copper in simulation and experimental based analysis. The results show that encapsulated TPG based heat spreader achieves more than 50% reduction in thermal resistance along with 48% reduction in weight in the heat spreader layer.

Gurpinar, Emre↗

Advanced Modeling and Simulations for Evaluation of Thermal Neutron Scattering Materials [Slides]

In this presentation, researchers detail tradeoffs between two simulation suites for thermal neutron scattering data. OXLIMAX + MCViNE provide a more accurate elastic peak shape and NJOY + MCNP have more accurate spectra between phonon mode peaks (most likely due to multiple neutron scattering). Additionally, some outstanding issues with MCViNE are noted, including multiple neutron scattering and non-uniform (Q,E) grid for data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗