Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermalize”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Thermal Conductivity of 3D Woven Composite Thermal Protection System Materials via Multiscale Recursive Micromechanics

Multiscale micromechanics predictions have been made for the effective thermal conductivities and local thermal fields for a novel 3D woven composite thermal protection system material. The Multiscale Recursive Micromechanics approach, which enables micromechanics models to call other micromechanics models (or themselves recursively) to consider finer and finer length scales, has been employed. The multiscale model uses a recently developed version of the High-Fidelity Generalized Method of Cells micromechanics theory at each of three length scales. Results focus on the impact of the microstructural geometry representation at each length scale on the material’s effective thermal conductivity, along with the local thermal flux and temperature fields induced in the microstructures.

Composites↗

Thermal Conductivity of 3D Woven Composite Thermal Protection System Materials via Multiscale Recursive Micromechanics

Multiscale micromechanics predictions have been made for the effective thermal conductivities and local thermal fields for a novel 3D woven composite thermal protection system material. The Multiscale Recursive Micromechanics approach, which enables micromechanics models to call other micromechanics models (or themselves recursively) to consider finer and finer length scales, has been employed. The multiscale model uses a recently developed version of the High-Fidelity Generalized Method of Cells micromechanics theory at each of three length scales. Results focus on the impact of the microstructural geometry representation at each length scale on the material’s effective thermal conductivity, along with the local thermal flux and temperature fields induced in the microstructures.

composite↗

Acoustic Emission Analysis of Damage Progression in Thermal Barrier Coatings Under Thermal Cyclic Conditions

Damage evolution of electron beam-physical vapor deposited (EBVD-PVD) ZrO2-7 wt.% Y2O3 thermal barrier coatings (TBCs) under thermal cyclic conditions was monitored using an acoustic emission (AE) technique. The coatings were heated using a laser heat flux technique that yields a high reproducibility in thermal loading. Along with AE, real-time thermal conductivity measurements were also taken using infrared thermography. Tests were performed on samples with induced stress concentrations, as well as calcium-magnesium-alumino-silicate (CMAS) exposure, for comparison of damage mechanisms and AE response to the baseline (as-produced) coating. Analysis of acoustic waveforms was used to investigate damage development by comparing when events occurred, AE event frequency, energy content and location. The test results have shown that AE accumulation correlates well with thermal conductivity changes and that AE waveform analysis could be a valuable tool for monitoring coating degradation and provide insight on specific damage mechanisms.

calcium-magnesium-alumino-silicate (CMAS)↗

Thermal Vacuum Test Correlation of a Zero Propellant Load Case Thermal Capacitance Propellant Gauging Analytical Model

This thesis describes the development and correlation of a thermal model that forms the foundation of a thermal capacitance spacecraft propellant load estimator. Specific details of creating the thermal model for the diaphragm propellant tank used on NASA's Magnetospheric Multiscale spacecraft using ANSYS and the correlation process implemented are presented. The thermal model was correlated to within plus or minus 3 degrees Celsius of the thermal vacuum test data, and was determined sufficient to make future propellant predictions on MMS. The model was also found to be relatively sensitive to uncertainties in applied heat flux and mass knowledge of the tank. More work is needed to improve temperature predictions in the upper hemisphere of the propellant tank where predictions were found to be 2 to 2.5 C lower than the test data. A road map for applying the model to predict propellant loads on the actual MMS spacecraft toward its end of life in 2017-2018 is also presented.

Gauging↗

James Webb Space Telescope Core 2 Test - Cryogenic Thermal Balance Test of the Observatorys Core Area Thermal Control Hardware

The James Webb Space Telescope (JWST), successor to the Hubble Space Telescope, will be the largest astronomical telescope ever sent into space. To observe the very first light of the early universe, JWST requires a large deployed 6.5-meter primary mirror cryogenically cooled to less than 50 Kelvin. Three scientific instruments are further cooled via a large radiator system to less than 40 Kelvin. A fourth scientific instrument is cooled to less than 7 Kelvin using a combination pulse-tube Joule-Thomson mechanical cooler. Passive cryogenic cooling enables the large scale of the telescope which must be highly folded for launch on an Ariane 5 launch vehicle and deployed once on orbit during its journey to the second Earth-Sun Lagrange point. Passive cooling of the observatory is enabled by the deployment of a large tennis court sized five layer Sunshield combined with the use of a network of high efficiency radiators. A high purity aluminum heat strap system connects the three instrument's detector systems to the radiator systems to dissipate less than a single watt of parasitic and instrument dissipated heat. JWST's large scale features, while enabling passive cooling, also prevent the typical flight configuration fully-deployed thermal balance test that is the keystone of most space missions' thermal verification plans. This paper describes the JWST Core 2 Test, which is a cryogenic thermal balance test of a full size, high fidelity engineering model of the Observatory's 'Core' area thermal control hardware. The 'Core' area is the key mechanical and cryogenic interface area between all Observatory elements. The 'Core' area thermal control hardware allows for temperature transition of 300K to approximately 50 K by attenuating heat from the room temperature IEC (instrument electronics) and the Spacecraft Bus. Since the flight hardware is not available for test, the Core 2 test uses high fidelity and flight-like reproductions.

JWST Thermal Core 2 Test↗

Developing a Foundation for Space-Based Two-Phase Thermal Control Systems: Future of 2-Phase Thermal Control

Two-phase thermal control systems in microgravity, with significant density differences between phases, pose challenges for many current and proposed spacecraft systems. Because of the lack of understanding of these effects and the inability to scale multiphase systems in low gravity, NASA generally opts to avoid using two-phase systems for spacecraft despite the significant performance increases and lower mass. The goal of this panel discussion will be to identify key technology gaps and challenges that thermal engineers face today when considering a two-phase thermal management system. The panel discussion will begin with a brief overview of recent and on-going NASA projects designed to elicit a fundamental understanding of gas-liquid two phase behavior as it applies to thermal control systems in the Space environment. The projects/experiments discussed will range from boiling/condensation fundamentals, heat pipes, and cryogenic storage systems. We will identify what fundamental question or questions are being addressed in each case. An overview will be also be presented to address future mission needs and the specific advantages multi-phase systems offer, in particular for low cost planetary science missions and enabling missions in extreme environments. The need for efficient heat transfer with concurrent spatial and temporal temperature stability to reduce thermally-induced noise drives a serious look at multi-phase systems as a solution. Furthermore, missions to environments such as the Venus surface or penetration of ice layers in ocean worlds will likely require them. Time will be allocated at the end of this session to allow comments and questions from attendees. The intent is to use this session as a starting point to advocate for a coordinated technology development effort in this area.

Thermal Control Systems↗

Multiscale Thermal Conductivity Modeling of 3D Woven Composite Thermal Protection System Materials

Novel thermal protection systems (TPS) for re-entry and hypersonic vehicles utilize 3D woven composite materials with blended carbon filament tows (yarns) and a phenolic resin matrix. The presence of continuous carbon fibers provides superior stiffness and strength compared to legacy TPS, while the 3D weave pattern provides a great deal of design flexibility for both in-plane and through thickness thermomechanical behavior. However, modeling of 3D woven composites is notoriously complex and numerically intensive. The present investigation utilizes a unique ultra-efficient approach, known as Multiscale Recursive Micromechanics (MsRM), wherein recursive semi-analytical micromechanics methods are employed at various length scales within the composite. The MsRM approach has recently been extended to solve for the effective thermal conductivity as well as the local temperature and thermal flux fields throughout the composite. Presented model results focus on the impact of the microstructural geometry representation at each length scale on the material’s effective thermal conductivity, along with the local thermal flux and temperature fields induced in the microstructures, for a novel 3D woven TPS.

Composite↗

Thermal diffusivity measurements using a pulsed dual-beam thermal lens technique

A novel pulsed dual-beam thermal lens technique for the determination of thermal diffusivity of liquids and solids was developed. In this technique a transient thermal lens is formed in the test specimen by using a dye laser pulse as a heating source and the thermal lens decay is monitored by means of a CW He-Ne laser. The technique is fast and contactless and avoids some of the major difficulties of conventional methods. Thermal diffusivities for water and a polycarbonate plastic were measured and found to be in agreement with literature values. Considerable simplification and minimization of certain errors was achieved by use of a reference material.

Gupta, M. C.↗

Double-beam optical method and apparatus for measuring thermal diffusivity and other molecular dynamic processes in utilizing the transient thermal lens effect

A sample material was irradiated by relatively high power, short pulses from a dye laser. Energy from the pulses was absorbed by the sample material, thereby forming a thermal lens in the area of absorption. The pulse repetition rate was chosen so that the thermal lens is substantially dissipated by the time the next pulse reaches the sample material. A probe light beam, which in a specific embodiment is a relatively low power, continuous wave (cw) laser beam, irradiated the thermal lens formed in the sample material. The intensity characteristics of the probe light beam subsequent to irradiation of the thermal lens is related to changes in the refractive index of the sample material as the thermal lens is formed and dissipated.

Moacanin, J.↗

Thermal and aerothermal performance of a titanium multiwall thermal protection system

A metallic thermal protection system (TPS) concept the multiwall designed for temperature and pressure at Shuttle body point 3140 where the maximum surface temperature is approximately 811 K was tested to evaluate thermal performance and structural integrity. A two tile model of titanium multiwall and a model consisting of a low temperature reusable surface insulation (LRSI) tiles were exposed to 25 simulated thermal and pressure Shuttle entry missions. The two systems performed the same, and neither system deteriorated during the tests. It is indicated that redesign of the multiwall tiles reduces tile thickness and/or weight. A nine tile model of titanium multiwal was tested for radiant heating and aerothermodynamics. Minor design changes that improve structural integrity without having a significant impact on the thermal protection ability of the titanium multiwall TPS are identified. The capability of a titanium multiwall thermal protection system to protect an aluminum surface during a Shuttle type entry trajectory at locations on the vehicle where the maximum surface temperature is below 811 K is demonstrated.

Avery, D. E.↗

Thermal design and experiment thermal integration of the Long Duration Exposure Facility

The Long Duration Exposure Facility (LDEF) is a large (14 feet diameter by 30 feet long) Shuttle transported, reusable spacecraft. The LDEF can accommodate up to 13,000 pounds of experiments mounted in 86 standard trays. This paper describes the philosophy and approach used for the passive thermal design of the LDEF. Also discussed are the standardized guidelines and techniques used in the thermal design and integration of approximately 50 different thermally passive experiments. A technique for reducing multinode thermal models of experiments to 2 nodes is also presented. This approach allows the efficient thermal integration of large numbers of experiments with the LDEF spacecraft.

Greene, R. F., Jr.↗

Advanced thermal energy management: A thermal test bed and heat pipe simulation

Work initiated on a common-module thermal test simulation was continued, and a second project on heat pipe simulation was begun. The test bed, constructed from surplus Skylab equipment, was modeled and solved for various thermal load and flow conditions. Low thermal load caused the radiator fluid, Coolanol 25, to thicken due to its temperature avoided by using a regenerator-heat-exchanger. Other possible solutions modeled include a radiator heater and shunting heat from the central thermal bus to the radiator. Also, module air temperature can become excessive with high avionics load. A second preoject concerning advanced heat pipe concepts was initiated. A program was written which calculates fluid physical properties, liquid and vapor pressure in the evaporator and condenser, fluid flow rates, and thermal flux. The program is directed to evaluating newer heat pipe wicks and geometries, especially water in an artery surrounded by six vapor channels. Effects of temperature, groove and slot dimensions, and wick properties are reported.

Barile, Ronald G.↗

Variable thermal properties and thermal relaxation time in hyperbolic heat conduction

Numerical solutions were obtained for a finite slab with an applied surface heat flux at one boundary using both the hyperbolic (MacCormack's method) and parabolic (Crank-Nicolson method) heat conduction equations. The effects on the temperature distributions of varying density, specific heat, and thermal relaxation time were calculated. Each of these properties had an effect on the thermal front velocity (in the hyperbolic solution) as well as the temperatures in the medium. In the hyperbolic solutions, as the density or specific heat decreased with temperature, both the temperatures within the medium and the thermal front velocity increased. The value taken for the thermal relaxation time was found to determine the 'hyperbolicity' of the heat conduction model. The use of a time dependent relaxation time allowed for solutions where the thermal energy propagated as a high temperature wave initially, but approached a diffusion process more rapidly than was possible with a constant large relaxation time.

Glass, David E.↗

Applications of high thermal conductivity composites to electronics and spacecraft thermal design

Recently, high thermal conductivity graphite fiber-reinforced metal matrix composites (MMCs) have become available that can save weight over present methods of heat conduction. Another significant advantage is that these materials can be used without the plumbing and testing complexities that accompany the use of liquid heat pipes. A spinoff of this research was the development of other MMCs as electronic device heat sinks. These use particulates rather than fibers and are formulated to match the coefficient of thermal expansion of electronic substrates in order to alleviate thermally induced stresses. The development of both types of these materials as viable weight-saving substitutes for the traditional methods of thermal control for electronics packaging and also for spacecraft thermal control applications are the subjects of this report.

Sharp, G. Richard↗

Estimation of tropical forest canopy temperatures, thermal response numbers, and evapotranspiration using an aircraft-based thermal sensor

Thermal infrared Multispectral Scanner (TIMS) data were collected at a resolution of 5 to 10 m from a tropical rain forest over an elevation gradient from 35 to 2700 m in the Braulio Carrillo National Park in Costa Rica. Flight lines were repeated with a 15 to 30 minute time difference for measurement of forest canopy thermal response over time. Concurrent radiosonde measurements of atmospheric profiles of air temperature and moisture provided inputs to LOWTRAN6 for atmospheric radiance corrections of the TIMS data. Techniques for using calibrated aircraft-based thermal scanner data to examine tropical forest canopy thermal properties are described. Forest canopy temperature changes over time assessed between repeated, duplicated flight lines were combined with estimates of surface radiative energy measurements from towers above the forest canopy to determine temperature spatial variability, calculate Thermal Response Numbers (TRN), and estimate evapotranspiration along the elevation gradient from selected one hectare forest inventory plots.

Luvall, Jeffrey C.↗

The test facility requirements for the thermal vacuum thermal balance test of the Cosmic Background Explorer Observatory

The Cosmic Background Explorer Observatory (COBE) underwent a thermal vacuum thermal balance test in the Space Environment Simulator (SES). This was the largest and most complex test ever conducted at this facility. The 4 x 4 m (13 x 13 ft) spacecraft weighed approx. 2223 kg (4900 lbs) for the test. The test set up included simulator panels for the inboard solar array panels, simulator panels for the flight cowlings, Sun and Earth Sensor stimuli, Thermal Radio Frequency Shield heater stimuli and a cryopanel for thermal control in the Attitude Control System Shunt Dissipator area. The fixturing also included a unique 4.3 m (14 ft) diameter Gaseous Helium Cryopanel which provided a 20 K environment for the calibration of one of the spacecraft's instruments, the Differential Microwave Radiometer. This cryogenic panel caused extra contamination concerns and a special method was developed and written into the test procedure to prevent the high buildup of condensibles on the panel which could have led to backstreaming of the thermal vacuum chamber. The test was completed with a high quality simulated space environment provided to the spacecraft. The test requirements, test set up, and special fixturing are described.

Milam, Laura J.↗

Thermally-induced structural dynamic response of flexural configurations influenced by linear/non-linear thermal effects

The thermally-induced strucural dynamic response of flexural configurations influenced by linear/nonlinear thermal effects is presented in conjunction with 'unified' transient approaches for effectively tackling this class of interdisciplinary problems. For illustrative purposes, the flexural structural models are assumed to be of the Euler-Bernoulli type. The purpose of the present paper is to not only provide an understanding of the influence of general linear/nonlinear thermal effects on flexural configurations, but also to provide to the analyst effective computational tools which help preserve a unified technology for the interdisciplinary areas encompassing structural mechanics/dynamics and thermal sciences. Several numerical test models illustrate the representative thermally-induced structural dynamic response of flexural configurations subjected to general linear/nonlinear temperature effects.

Namburu, Raju R.↗

Test facility requirements for the thermal vacuum thermal balance test of the Cosmic Background Explorer Observatory

The Cosmic Background Explorer Observatory (COBE) underwant a thermal vacuum thermal balance test in the Space Environment Simulator (SES). This was the largest and most complex test ever conducted at this facility. The 4 x 4 m (13 x 13 ft) spacecraft weighed approx. 2223 kg (4900 lbs) for the test. The test set up included simulator panels for the inboard solar array panels, simulator panels for the flight cowlings, Sun and Earth Sensor stimuli, Thermal Radio Frequency Shield heater stimuli and a cryopanel for thermal control in the Attitude Control System Shunt Dissipator area. The fixturing also included a unique 4.3 m (14 ft) diameter Gaseous Helium Cryopanel which provided a 20 K environment for the calibration of one of the spacecraft's instruments, the Differential Microwave Radiometer. This cryogenic panel caused extra contamination concerns and a special method was developed and written into the test procedure to prevent the high buildup of condensibles on the panel which could have led to backstreaming of the thermal vacuum chamber. The test was completed with a high quality simulated space environment provided to the spacecraft. The test requirements, test set up, and special fixturing are described.

Milam, Laura J.↗