Search NASA⌕ Search

SEARCH · Search NASA

Results for “time domain simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Evaluation of nonlinear control performance of air handling units under variable operation conditions using root distribution approach

The control systems at Air handling units (AHUs) have nonlinear nature, resulting potentially in sluggish, aggressive, or oscillatory responses under variable operation conditions. This paper is to develop an approach for evaluating the nonlinear control performance of AHUs under variable operation conditions and for identifying the impact of varying multiple operation parameters which guides controller design. To do so, an operation parameter-based root distribution technique, intended to sketch the paths traced by closed-loop poles as multiple operation parameters are varied, is first introduced. The technique—which may be viewed as an extension of conventional, single-variable root locus—is then applied to a fan speed control system that includes a motor with a variable frequency drive and a supply fan with an air duct under variable fan speed and duct static pressure. Using the technique, the system’s stability region is graphically identified. The system is also found to be aggressive and gradually lose its stability as the fan speed decreases and the duct static pressure increases, which is validated by the field tests. Here, the root distribution approach is an effective tool to evaluate the performance of any nonlinear control systems at AHUs with multiple variable operation parameters without requiring time-domain simulations.

42 ENGINEERING↗

Effect of activation temperature on quantum efficiency and lifetime of NEA truncated nanocone array GaAs photocathode

This study investigates the quantum efficiency (QE) and operational lifetime of a negative electron affinity GaAs truncated nanocone array (TNCA) photocathode benchmarked against a conventional flat GaAs photocathode under varying activation temperatures. The TNCA structure demonstrated a QE of up to 13.6% at 590 nm with room temperature (RT) activation—approximately 1.5 times higher than its flat counterpart. This enhancement is due to Mie resonance effects within the nanostructure, as confirmed by finite-difference time-domain simulations. Moreover, the TNCA photocathode exhibits significantly extended charge lifetime, with enhancement factors of ∼6.1 and ∼19.8 under RT and 50 °C activations, respectively. These gains are primarily attributed to increased effective surface area and optimized dipole layer formation at elevated temperatures. In addition, shorter excitation wavelengths further contribute to lifetime improvements. These findings underscore the TNCA GaAs photocathode’s potential as a high QE, long lifetime electron source for many large-scale electron accelerators.

Cs-NF3 activation↗

Dark and bright modes, and their coherent control in dipolar metasurface bilayers

Several plasmonic nanoparticles supporting dipolar resonances can couple to form normal modes. Here, we develop an analytical model to explain the formation of nonradiative “dark” and radiative “bright” modes through radiative coupling in bilayers consisting of dipolar nanoantenna arrays that are separated by a subwavelength distance. We also include near-field contributions in our model and show that the absorption and reflectance spectra obtained from our model agree reasonably well with the respective finite-difference time-domain simulation results for both perfectly aligned and misaligned bilayers. Here, the ability to vary the reflection and absorption spectra of these bilayers by changing the material and geometrical parameters has potential applications in the design of efficient spectral filters. We also show that we can selectively excite these modes by adjusting the phase between two counterpropagating normally incident fields, which has applications in all-optical modulators and switches based on purely linear interferometric effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparative Small-Signal Stability Analysis of Grid-Forming and Grid-Following Inverters in Low-Inertia Power Systems: Preprint

Inverter-based resources (IBRs) are gradually replacing conventional fossil energy in modern power systems, which could make the system susceptible due to insufficient inertia, especially when moving towards a 100% inverter-based power grid. Grid-forming (GFM) and grid-following (GFL) controls are two common inverter control algorithms. However, the corresponding stability issues along with a comparative study on low-inertia power systems should still be investigated. This paper focuses on small-signal stability and conducts a comprehensive analysis of GFM and GFL controls, with emphases on the interactions between synchronous generators and IBRs. The detailed modeling of GFM and GFL inverters, and synchronous generators (SGs) are established. The coupling mechanism of IBRs and SGs is then conducted through participation factor analysis. The impacts of critical parameters on system stability are finally identified. The theoretical analyses are validated through time-domain simulation in MATLAB/Simulink.

grid-following↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Generalized Power Flow Model of an Extra High-Power Multi-Terminal HVdc Transmission Grid with Parallel-Connected and Voltage-Stacked Converters

To increase power transfer capacity of high-voltage direct current (HVdc) transmission, a new extra high-power HVdc architecture with multiple standard modular multilevel converters (MMCs) per substation has recently been introduced. This paper proposes a power flow model for a multi-terminal HVdc (MTdc) grid with this innovative substation architecture. The proposed MTdc model can be integrated seamlessly with existing ac-dc power flow algorithms with minimal modifications. The model is applicable to various MTdc grid types and topologies, different numbers of dc buses, dc lines, and MMCs per substation, along with diverse control parameters. In addition, it accurately captures both balanced and unbalanced operations of the MTdc grid. The proposed model is verified using a 5-terminal bipole MTdc grid that spans 4 areas in the Eastern Interconnection system of the USA. The numerical solutions obtained from unified and sequential ac-dc power flow algorithms under different operating conditions closely match the time-domain simulation results in PSCAD, validating the accuracy and versatility of the proposed MTdc power flow model.

Nguyen, Quan H.↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Root Cause Analysis of AC Overcurrent in July 2020 San Fernando Disturbance

On July 7 2020, approximately 1,000 MW reduction in solar photovoltaic (PV) output was experienced by the bulk power system in Southern California after a three-phase fault. Disturbance analysis indicates that instantaneous AC current caused inverter tripping. The projection of the root cause of AC overcurrent from the NERC report is that inverter current control is not tight. This letter provides a quantitative analysis on ac overcurrent and addresses the following questions: (i) what type of current controls may lead to ac overcurrent; and (ii) how controller parameters and grid strength influence ac overcurrent. Here, the letter provides frequency-domain analysis and time-domain simulation results of a grid-integrated inverter to illustrate the effect of control parameters and grid strength on ac overcurrent.

14 SOLAR ENERGY↗

Power Flow Models of Grid-Forming Inverters in Unbalanced Distribution Grids

Load unbalance in electric distribution systems is unavoidable. Unbalanced load currents will lead to negative sequence (NS) voltages that may damage electric equipment. Unbalanced power flow analysis is a common tool to detect and mitigate NS voltage issues and requires accurate models of grid components. While traditional source models are available, grid-forming (GFM) inverter models are not well developed. GFM inverters implement various control strategies, which affect their power flow models. Here, in this paper, a novel GFM inverter model considering control effects is proposed. We show that for some control methods, unbalanced system loading will lead to unbalanced terminal voltages of the GFM inverters, which are modeled through an equivalent negative sequence impedance. The proposed models are initially validated using a simple test circuit. Then, they are applied in the power flow analysis on the IEEE 13-bus and 34-bus systems to demonstrate the accuracy improvement over the state-of-the-art. Using time-domain simulations as benchmarks, we show that the proposed models reduce the calculation error of negative sequence voltages by at least 25% in unbalanced distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Safe Reinforcement Learning-Based Transient Stability Control for Islanded Microgrids With Topology Reconfiguration

This paper proposes a safe reinforcement learning (RL)-based transient stability emergency control (TSEC) method for islanded microgrids. RL requires extensive interaction with the environment to learn control strategies, hence, a data-driven approach is used as a substitute for time-consuming time-domain simulation calculations. Deep sigma point processes (DSPP), which is a Gaussian process model, is utilized to predict the normal distribution of transient stability of microgrids and to construct a transient stability chance constraint. Reward-constrained policy optimization (RCPO) can simultaneously achieve objective prediction, policy learning, and constraint cost coefficient update across multiple timescales. RCPO interacts with the DSPP-based microgrid environment through a multi-process parallel manner, greatly increasing the training speed. Case studies on a real islanded microgrid demonstrate that the proposed method can efficiently and quickly obtain the optimal emergency control strategy while adhering to all hard constraints.

14 SOLAR ENERGY↗

Dual-polarization Dirac cones in a simple 2D square lattice photonic crystal

We report on dual-polarization Dirac cones in a simple square lattice two-dimensional (2D) photonic crystal (PC) based on transmission at accidental degeneracies centered at the k = 0 symmetry ( Γ <#comment/> ) point. Finite difference time domain simulations are used to identify the material and geometric parameters for Dirac-like dispersion. A configuration that produces a Dirac-like point for both transverse electric and transverse magnetic polarizations at the same frequency is presented. The PC dispersion shows the expected threefold degenerate linear branch crossings at the Dirac-like point. Full-field electromagnetic wave simulations exhibit some common behaviors of devices based on Dirac-like dispersion, such as cloaking and waveguiding. The configuration works for a considerable range of the parameter space, and thus is experimentally realizable with a wide range of materials.

Rodríguez, J. A. (ORCID:0000000178926207)↗

Angle- and polarization-resolved luminescence from suspended and hexagonal boron nitride encapsulated MoSe 2 monolayers

The polarized photoluminescence from atomically thin transition metal dichalcogenides is a frequently applied tool to scrutinize optical selection rules and valley physics, yet it is known to sensibly depend on a variety of internal and external material and sample properties. In this work, we apply combined angle- and polarization-resolved spectroscopy to explore the interplay of excitonic physics and phenomena arising from the commonly utilized encapsulation procedure on the optical properties of atomically thin M o S e 2 . We probe monolayers prepared in both suspended and encapsulated manners. We show that the hBN encapsulation significantly enhances the linear polarization of exciton photoluminescence emission at large emission angles. This degree of linear polarization of excitons can increase up to ∼ <#comment/> 17 % <#comment/> in the hBN encapsulated samples. As we confirm by finite-difference time-domain simulations, it can be directly connected to the optical anisotropy of the hBN layers. In comparison, the linear polarization at finite exciton momenta is significantly reduced in a suspended M o S e 2 monolayer, and becomes notable only in cryogenic conditions. This phenomenon strongly suggests that the effect is rooted in the k-dependent anisotropic exchange coupling inherent in 2D excitons. Our results have strong implications on further studies on valley contrasting selection rules and valley coherence phenomena using standard suspended and encapsulated samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adjoint-optimized nanoscale light extractor for nitrogen-vacancy centers in diamond

Abstract We designed a nanoscale light extractor (NLE) for the efficient outcoupling and beaming of broadband light emitted by shallow, negatively charged nitrogen-vacancy (NV) centers in bulk diamond. The NLE consists of a patterned silicon layer on diamond and requires no etching of the diamond surface. Our design process is based on adjoint optimization using broadband time-domain simulations and yields structures that are inherently robust to positioning and fabrication errors. Our NLE functions like a transmission antenna for the NV center, enhancing the optical power extracted from an NV center positioned 10 nm below the diamond surface by a factor of more than 35, and beaming the light into a ±30° cone in the far field. This approach to light extraction can be readily adapted to other solid-state color centers.

42 ENGINEERING↗

System Integration Analysis for Modular Solid-State Substations

Structural modularity is critical to solid-state transformer (SST) and solid-state power substation (SSPS) concepts, but operational aspects related to this modularity are not yet fully understood. Previous studies and demonstrations of modular power conversion systems assume identical module compositions, but dependence on module uniformity undercuts the value of the modular framework. In this project, a hierarchical control approach was developed for modular SSTs which achieves system-level objectives while ensuring equitable power sharing between nonuniform building block modules. This enables module replacements and upgrades which leverage circuit and device technology advancements to improve system-level performance. The functionality of the control approach is demonstrated in detailed time-domain simulations. Results of this project provide context and strategic direction for future LDRD projects focusing on technologies supporting the SST crosscut outcome of the resilient energy systems mission campaign.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A State-Space Model for Stability Boundary Analysis of Grid-Following Voltage Source Converters Considering Grid Conditions

With the growing significance of renewable energy resources and energy storage systems, the number of grid-connected inverters has been rising at an increasingly rapid pace. Generally, these inverters are directly integrated with the distribution network by synchronizing with the grid voltage at the point of common coupling. However, the low grid strength and varying R/X ratios, as the common characteristics of most distribution networks or weak grids, can lead to dynamic interactions that comprise stability and limit the power transfer capacity of grid-connected inverters. To ensure stable operation of the inverters, researchers must determine the stability boundary, described as the maximum power transfer capacity of grid-connected inverters under the premise of maintaining system small-signal stability. For this purpose, we propose to formulate a state-space model of the system in the synchronously rotating dq-frame of reference and perform eigenvalue analysis to determine the stability boundary. With a detailed model of the control structure and parameters of the grid-connected inverters, the stability boundary is identified as a surface with respect to different grid strengths and R/X ratios. Case study results of proposed eigenvalue analysis are compared with those of admittance model-based stability analysis as well as time-domain simulation using a switching model in Matlab/Simulink, validating the effectiveness and accuracy of the proposed eigenvalue analysis for stability boundary identification.

grid-connected inverters↗

Asymmetric Dual-Grating Dielectric Laser Accelerator Optimization

Although hundreds of keV in energy gain have already been demonstrated in dielectric laser accelerators (DLAs), the challenge of creating structures that can confine electrons for multiple millimeters remains. We focus here on dual gratings with single-sided drive, which have experimentally demonstrated energy modulation numerous times. Using a Finite-Difference Time-Domain simulation to find the fields within various DLA structures and correlating these results with particle tracking simulation, we look at the impact of teeth height and width, as well as gap and offset, on the performance of these structures. We find a tradeoff between electron throughput and acceleration; however, we also find that for any given grating geometry, there is a gap and offset that will allow some charge acceleration. For our 780 nm laser wavelength, this results in a 1200 nm optimal gap size for most gratings.

Crisp, Sophie (ORCID:0000000327503727)↗