Search NASA⌕ Search

SEARCH · Search NASA

Results for “time of flight”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Fatigue in Short-Haul Operations: Regulations and Research

Short-haul multi-segment flight operations are conducted within Part 117 table limits for Flight Time and Flight Duty Period, yet there are few data available regarding the impact on sleep, workload, and performance in these operations. The Civil Aerospace Medical Institute (CAMI) has invested in the planning and execution of a study that will result in data characterizing the effects of short-haul multi-segment flight operations on cumulative sleep loss and pilot workload across trip pairings. Scientific researchers from CAMI, in collaboration with NASA Ames Research Center, are currently running an operational field study to examine the human factors and elements of pilot performance associated with short-haul multi-segment flight operations to better understand the impact of sleep disruption and workload across trip pairings. The first half of this presentation will provide a brief overview of current duty and rest requirements and identify gaps in current operational research data. The second half of the presentation will focus on results from a focus group study which developed the scope of the larger field study, followed by an overview of the current field study.

short-haul↗

Time-of-flight mobility and trapping results for ZnSe.

Results of measurements of time-of-flight mobility and trapping for zinc selenide. The data were obtained at room temperature for electric fields in the range from 30,000 to 800,000 V/cm. A relatively constant hole mobility (about 50 sq cm/V sec) was found for the entire range of investigated fields. The electron mobility was approximately constant (about 400 sq cm/V sec) up to approximately equal to 300,000 V/cm, above which the drift velocity remained constant. No obvious negative differential mobility was observed, even though the Gunn effect has been reported for the field range investigated. Trapping and detrapping times in the vicinity of 1 nsec are reported for both holes and electrons. The field dependence of the electron-trapping times is unusual and remains unexplained.

Heaton, J. L., III↗

Effect of Trapped Ions in a Gated Time-of-Flight Apparatus

K.E. Martus,O.J. Orient,A Three-mesh gate is used in a time-of-flight(TOF) apparatus to analyze the Velocity of positive ions. Test results and a theoretical description are presented of an effect arising from trapping ions between meshes of a two gate TOF velocity analyzer. The entrapped ions produce a side peak in the TOF spectra corresponding to faster ions.

time-of-flight↗

Effect of trapped ions in a gated time-of-flight apparatus

A three-mesh gate is used in a time-of-flight (TOF) apparatus to analyze the velocity of positive ions. Test results and a theoretical description are presented of an effect arising from trapping ions between meshes of a two-gate TOF velocity analyzer. The entrapped ions produce a side peak in the TOF spectra corresponding to faster ions. The onset and relative height of the side peak is dependent on the gating voltage and risetime of the pulsing electronics, while the relative intensity depends upon the velocity being sampled and the ratio of the gate width to duration.

Martus, K. E.↗

Four-Spot Time-Of-Flight Laser Anemometer For Turbomachinery

Two-color, four-spot time-of-flight laser anemometer designed for measuring flow velocity within narrow confines of small centrifugal compressor. Apparatus well suited for measuring fast (typical speeds 160 to 700 m/s), highly turbulent gas flows in turbomachinery. Other potential applications include measurement of gas flows in pipelines and in flows from explosions.

Wernet, Mark P.↗

A Segmented Time-of-Flight Mass Spectrometer

The present paper describes the design of a time-of-flight mass spectrometer (TOFMS) in which the single flight tube of a conventional TOFMS has been replaced by several cylindrical electrostatic lenses in tandem. By a judicious choice of voltages on these lenses, an improved TOFMS has been realized which has a superior mass and energy resolution, shorter flight lengths, excellent signal-to-noise ratio and less stringent requirements on the bias voltages.

Srivastava, S. K.↗

Laser Time-of-Flight Mass Spectrometry for Future In Situ Planetary Missions

Laser desorption/ionization time-of-flight mass spectrometry (LD-TOF-MS) is a versatile, low-complexity instrument class that holds significant promise for future landed in situ planetary missions that emphasize compositional analysis of surface materials. Here we describe a 5kg-class instrument that is capable of detecting and analyzing a variety of analytes directly from rock or ice samples. Through laboratory studies of a suite of representative samples, we show that detection and analysis of key mineral composition, small organics, and particularly, higher molecular weight organics are well suited to this instrument design. A mass range exceeding 100,000 Da has recently been demonstrated. We describe recent efforts in instrument prototype development and future directions that will enhance our analytical capabilities targeting organic mixtures on primitive and icy bodies. We present results on a series of standards, simulated mixtures, and meteoritic samples.

Getty, S. A.↗

The time-of-flight system on the Goddard medium energy gamma-ray telescope

A scintillation counter time of flight system, incorporated into the Goddard 50 cm by 50 cm spark chamber gamma ray telescope is described. The system, which utilizes constant fractions timing and particle position compensation and digitizes up to 10 ns time differences to six bit accuracy in less than 500 ns is analyzed. The performance of this system during balloon flight is discussed.

Ross, R. W.↗

The time-of-flight system on the Goddard medium energy gamma-ray telescope

A scintillation counter time-of-flight system has been incorporated into the Goddard 50 cm by 50 cm spark chamber gamma-ray telescope. This system, utilizing constant fraction timing and particle position compensation, digitizes up to 10 ns time differences to six bit accuracy in less than 500 ns. Event selection decisions, discriminating against upward-moving particles, are made prior to spark chamber triggering. The performance of this system during a November 1978 balloon flight is discussed.

Ross, R. W.↗

Two-step Laser Time-of-Flight Mass Spectrometry to Elucidate Organic Diversity in Planetary Surface Materials.

Laser desorption/ionization time-of-flight mass spectrometry (LD-TOF-MS) holds promise to be a low-mass, compact in situ analytical capability for future landed missions to planetary surfaces. The ability to analyze a solid sample for both mineralogical and preserved organic content with laser ionization could be compelling as part of a scientific mission pay-load that must be prepared for unanticipated discoveries. Targeted missions for this instrument capability include Mars, Europa, Enceladus, and small icy bodies, such as asteroids and comets.

Europa↗

Biomark/Organic Analysis with Time-of-Flight Mass Spectrometry

The concept of a Comprehensive 2-Dimensional Gas Chromatography coupled with Time-of-Flight Mass Spectrometry (GCxGC-TOWS) for the analysis of organic compounds has been proven with commercially available instrumentation (LECO Corp). The performance of a GCxGC instrument has been characterized in various stages using two independent breadboard systems. The GCxGC separation systems, including the thermal modulator, have been miniaturized to the size of a benchtop configuration. One breadboard system employs a Flame Ionization Detector (FID), whereas the second breadboard system employs a Time-of-Fight mass spectrometer (TOFWS) as a detection system.

Waite, J. Hunter, Jr.↗

Video Guidance Sensor and Time-of-Flight Rangefinder

A proposed video guidance sensor (VGS) would be based mostly on the hardware and software of a prior Advanced VGS (AVGS), with some additions to enable it to function as a time-of-flight rangefinder (in contradistinction to a triangulation or image-processing rangefinder). It would typically be used at distances of the order of 2 or 3 kilometers, where a typical target would appear in a video image as a single blob, making it possible to extract the direction to the target (but not the orientation of the target or the distance to the target) from a video image of light reflected from the target. As described in several previous NASA Tech Briefs articles, an AVGS system is an optoelectronic system that provides guidance for automated docking of two vehicles. In the original application, the two vehicles are spacecraft, but the basic principles of design and operation of the system are applicable to aircraft, robots, objects maneuvered by cranes, or other objects that may be required to be aligned and brought together automatically or under remote control. In a prior AVGS system of the type upon which the now-proposed VGS is largely based, the tracked vehicle is equipped with one or more passive targets that reflect light from one or more continuous-wave laser diode(s) on the tracking vehicle, a video camera on the tracking vehicle acquires images of the targets in the reflected laser light, the video images are digitized, and the image data are processed to obtain the direction to the target. The design concept of the proposed VGS does not call for any memory or processor hardware beyond that already present in the prior AVGS, but does call for some additional hardware and some additional software. It also calls for assignment of some additional tasks to two subsystems that are parts of the prior VGS: a field-programmable gate array (FPGA) that generates timing and control signals, and a digital signal processor (DSP) that processes the digitized video images. The additional timing and control signals generated by the FPGA would cause the VGS to alternate between an imaging (direction-finding) mode and a time-of-flight (range-finding mode) and would govern operation in the range-finding mode.

Bryan, Thomas↗

Time-of-flight velocity analysis of atomic and molecular beams

Conditions required for resolving a given beam speed distribution were evaluated by calculating the time-of-flight (TOF) signal for a finite open time of the beam shutter. Design criteria for a beam chopper and detection system are discussed in terms of the resolution, the range of speeds to be measured, and the optimum signal to noise ratio. A TOF system for detection of high intensity molecular beams with large speed ratios, as well as for low intensity scattered beams, is described. Experimental results are presented.

Hagena, O. F.↗

Sensors for Using Times of Flight to Measure Flow Velocities

Thin-film sensors for measuring flow velocities in terms of times of flight are undergoing development. These sensors are very small and can be mounted flush with surfaces of airfoils, ducts, and other objects along which one might need to measure flows. Alternatively or in addition, these sensors can be mounted on small struts protruding from such surfaces for acquiring velocity measurements at various distances from the surfaces for the purpose of obtaining boundary-layer flow-velocity profiles. These sensors are related to, but not the same as, hot-wire anemometers. Each sensor includes a thin-film, electrically conductive loop, along which an electric current is made to flow to heat the loop to a temperature above that of the surrounding fluid. Instantaneous voltage fluctuations in segments of the loop are measured by means of electrical taps placed at intervals along the loop. These voltage fluctuations are caused by local fluctuations in electrical resistance that are, in turn, caused by local temperature fluctuations that are, in turn, caused by fluctuations in flow-induced cooling and, hence, in flow velocity. The differential voltage as a function of time, measured at each pair of taps, is subjected to cross-correlation processing with the corresponding quantities measured at other pairs of taps at different locations on the loop. The cross-correlations yield the times taken by elements of fluid to travel between the pairs of taps. Then the component of velocity along the line between any two pairs of taps is calculated simply as the distance between the pairs of taps divided by the travel time. Unlike in the case of hot-wire anemometers, there is no need to obtain calibration data on voltage fluctuations versus velocity fluctuations because, at least in principle, the correlation times are independent of the calibration data.

Fralick, Gutave↗