Search NASA⌕ Search

SEARCH · Search NASA

Results for “timing error evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Real-Time Point Positioning Performance Evaluation of Single-Frequency Receivers Using NASA's Global Differential GPS System

This paper evaluates the performance of a single-frequency receiver using the 1-Hz differential corrections as provided by NASA's global differential GPS system. While the dual-frequency user has the ability to eliminate the ionosphere error by taking a linear combination of observables, the single-frequency user must remove or calibrate this error by other means. To remove the ionosphere error we take advantage of the fact that the magnitude of the group delay in range observable and the carrier phase advance have the same magnitude but are opposite in sign. A way to calibrate this error is to use a real-time database of grid points computed by JPL's RTI (Real-Time Ionosphere) software. In both cases we evaluate the positional accuracy of a kinematic carrier phase based point positioning method on a global extent.

internet-based global differential GPS (IGDG)↗

Offline Maximizing Minimally Invasive Proper Orthogonal Decomposition for Reduced-Order Modeling of S n Radiation Transport

Deterministic solutions to the Sn radiation transport equation can be computationally expensive to calculate. Reduced-order modeling enables efficient approximation of the full-order model (FOM) solution. We propose a novel method for constructing reduced-order models (ROMs) of the S n radiation transport equation, offline maximizing minimally invasive (OMMI) proper orthogonal decomposition (POD). POD uses the method of snapshots to create a reduced-order basis for constructing an ROM. Minimally invasive POD leverages the sweep infrastructure existing in deterministic transport codes to create a POD-based ROM, even when infeasible by traditional methods. Offline maximizing minimally invasive proper orthogonal decomposition (OMMI-POD) extends minimally invasive POD by performing sweeps offline, therefore maximizing the potential speedup. OMMI-POD does so by creating a library of reduced systems from a training set. This library of reduced systems is then interpolated to provide a rapid approximate solution of the S n radiation transport equation. The model is evaluated on a set of test problems, achieving a low error with a 466 times speedup over the FOM. Also presented is a study of the effect of sampling method on the performance of OMMI-POD, specifically comparing naive uniform sampling to the more accurate and computationally expensive greedy sampling.

97 MATHEMATICS AND COMPUTING↗

Predicting initial trans-membrane pressure across cycles in the ultrafiltration process using random forest

With growing freshwater scarcity, direct potable reuse (DPR) systems that reclaim wastewater for drinking are becoming increasingly important for sustainable water supply. Reliable operation requires minimizing downtime in ultrafiltration (UF) units, where membrane fouling leads to elevated trans-membrane pressure (TMP). This study develops data-driven regression models based on random forest (RF) and autoregressive (AR) approaches to forecast the initial TMP at the start of each UF filtration cycle in a pilot-scale DPR system. The RF model consistently outperforms baseline methods, including historical mean, last observation carried forward, and AR models, across multiple forecast horizons, achieving the lowest root mean square error. To evaluate how different classes of process variables contribute to TMP dynamics over time, we examine the feature importance of independent input variables across multiple forecast horizons. This analysis provides insight into the temporal relevance of operational and sensor-derived features, guiding control and monitoring strategies. Additionally, the impact of hyperparameter tuning on TMP prediction performance is assessed for both direct and recursive RF modelling approaches. The proposed RF framework establishes a robust foundation for predictive monitoring and real-time optimization of UF operations, supporting sustainable and reliable water reuse.

direct potable reuse↗

Numerical integration of second order differential equations

Performance characteristics of higher order approximations of Runge-Kutta type are analyzed, and performance predictors for time required on machine and for error size are developed. Technique is useful in evaluating system performance, analyzing material characteristics, and designing inertial guidance and nuclear instrumentation and materials.

Shanks, E. B.↗

General Purpose Computer (GPC) to GPC systems interface description

The General Purpose Computer (GPC) 'subsystem' of the Orbiter Data Processing System was described. Two interface areas are discussed. One is the area of GPC intraconnections and intracommunications involving the hardware/software interface between the Central Processing Unit (CPU) and the Input/Output Processor (IOP). The other is the area of GPC interconnections and intercommunications and involves the hardware/software interface between the five Orbiter GPC's. Based on the detailed GPC interface given, it is felt that the basic CPU to IOP interface and the GPC to GPC interface have the potential for trouble free operation. However, due to the complexity of the interface and the criticality of GPC synchronization to overall avionics performance, the GPC to GPC interface should be carefully evaluated when attempting to resolve test anomalies that may involve GPC timing and synchronization errors.

Breyer, B. C.↗

Full field flow visualization and computer-aided velocity measurements in a bank of cylinders in a wind tunnel

The full field flow tracking (FFFT) method that is presented in this paper uses a laser-generated, mechanically strobed planar sheet of light, a low luminosity TV camera coupled with a long distance microscope, and a computer-controlled video recorder to study nonintrusively and qualitatively the flow structures in a bank of cylinders that are placed in a wind tunnel. This setup simulates an upscale version of the geometry of internal cooling passageways characteristic of small air-cooled radial turbines. The qualitative images supplied by the FFFT system are processed by means of a computer-integrated image quantification (CIIQ) method into quantitative information, trajectories and velocities, that describe the flow upstream of and within the bank of cylinders. The tracking method is Lagrangian in concept, and permits identification and tracking of the same particle, thus facilitating construction of time dependent trajectories and the calculation of true velocities and accelerations. The error analysis evaluates the accuracy with which the seed particles follow the flow and the errors incurred during the quantitative processing of the raw data derived from the FFFT/CIIQ method.

Braun, M. J.↗

Testing, Requirements, and Metrics

The criticality of correct, complete, testable requirements is a fundamental tenet of software engineering. Also critical is complete requirements based testing of the final product. Modern tools for managing requirements allow new metrics to be used in support of both of these critical processes. Using these tools, potential problems with the quality of the requirements and the test plan can be identified early in the life cycle. Some of these quality factors include: ambiguous or incomplete requirements, poorly designed requirements databases, excessive or insufficient test cases, and incomplete linkage of tests to requirements. This paper discusses how metrics can be used to evaluate the quality of the requirements and test to avoid problems later. Requirements management and requirements based testing have always been critical in the implementation of high quality software systems. Recently, automated tools have become available to support requirements management. At NASA's Goddard Space Flight Center (GSFC), automated requirements management tools are being used on several large projects. The use of these tools opens the door to innovative uses of metrics in characterizing test plan quality and assessing overall testing risks. In support of these projects, the Software Assurance Technology Center (SATC) is working to develop and apply a metrics program that utilizes the information now available through the application of requirements management tools. Metrics based on this information provides real-time insight into the testing of requirements and these metrics assist the Project Quality Office in its testing oversight role. This paper discusses three facets of the SATC's efforts to evaluate the quality of the requirements and test plan early in the life cycle, thus preventing costly errors and time delays later.

Rosenberg, Linda↗

Adverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015

Purpose: Radiation oncology relies on rapidly evolving technology and highly complex processes. The US Food and Drug Administration collects reports of adverse events related to medical devices. We sought to characterize all events involving radiation oncology devices (RODs) from the US Food and Drug Administration's postmarket surveillance Manufacturer and User Facility Device Experience (MAUDE) database, comparing these with non–radiation oncology devices. Methods and Materials: MAUDE data on RODs from 1991 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems) and 5 device problem categories (software, mechanical, electrical, user error, and dose delivery impact). Outcomes included whether the device was evaluated by the manufacturer, adverse event type, remedial action, problem code, device age, and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by the Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 4234 ROD and 4,985,698 other device adverse event reports. Adverse event reports increased over time, and events involving RODs peaked in 2011. Most ROD reports involved external beam therapy (50.8%), followed by brachytherapy (24.9%) and treatment planning systems (21.6%). The top problem types were software (30.4%), mechanical (20.9%), and user error (20.4%). RODs differed significantly from other devices in each outcome (P<.001). RODs were more likely to be evaluated by the manufacturer after an event (46.9% vs 33.0%) but less likely to be recalled (10.5% vs 37.9%) (P<.001). Device age and time since 510(k) approval were shorter among RODs (P<.001). Conclusions: Compared with other devices, RODs may experience adverse events sooner after manufacture and market approval. Close postmarket surveillance, improved software design, and manufacturer–user training may help mitigate these events.

07 ISOTOPE AND RADIATION SOURCES↗

MO-G-BRE-06: Metrics of Success: Measuring Participation and Attitudes Related to Near-Miss Incident Learning Systems

Purpose: Interest in incident learning systems (ILS) for improving safety and quality in radiation oncology is growing, as evidenced by the upcoming release of the national ILS. However, an institution implementing such a system would benefit from quantitative metrics to evaluate performance and impact. We developed metrics to measure volume of reporting, severity of reported incidents, and changes in staff attitudes over time from implementation of our institutional ILS. Methods: We analyzed 2023 incidents from our departmental ILS from 2/2012–2/2014. Incidents were prospectively assigned a near-miss severity index (NMSI) at multidisciplinary review to evaluate the potential for error ranging from 0 to 4 (no harm to critical). Total incidents reported, unique users reporting, and average NMSI were evaluated over time. Additionally, departmental safety attitudes were assessed through a 26 point survey adapted from the AHRQ Hospital Survey on Patient Safety Culture before, 12 months, and 24 months after implementation of the incident learning system. Results: Participation in the ILS increased as demonstrated by total reports (approximately 2.12 additional reports/month) and unique users reporting (0.51 additional users reporting/month). Also, the average NMSI of reports trended lower over time, significantly decreasing after 12 months of reporting (p<0.001) but with no significant change at months 18 or 24. In survey data significant improvements were noted in many dimensions, including perceived barriers to reporting incidents such as concern of embarrassment (37% to 18%; p=0.02) as well as knowledge of what incidents to report, how to report them, and confidence that these reports were used to improve safety processes. Conclusion: Over a two-year period, our departmental ILS was used more frequently, incidents became less severe, and staff confidence in the system improved. The metrics used here may be useful for other institutions seeking to create or evaluate their own incident learning systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

On The Jacobian of the ECEF J2 Gravitation Model

An Earth-centered, Earth-fixed (ECEF) inertial navigation system must compute the Jacobian of its employed gravitation model with respect to position while time-propagating the error covariance of the system. One commonly used gravitation model is the ‘J2 model’ which is a second-order truncation of the Earth’s spherical harmonic gravitation model. The J2 model is popular because it can quickly and efficiently be evaluated, and the truncation error is small: The ‘J3 term’ --- the third term in the spherical harmonic expansion --- is approximately 1000 times smaller than the J2 term.

42 ENGINEERING↗

MO-C-17A-04: Forecasting Longitudinal Changes in Oropharyngeal Tumor Morphology Throughout the Course of Head and Neck Radiation Therapy

Purpose: To generate, evaluate, and compare models that predict longitudinal changes in tumor morphology throughout the course of radiation therapy. Methods: Two morphology feature vectors were used to describe the size, shape, and position of 35 oropharyngeal GTVs at each treatment fraction during intensity-modulated radiation therapy. The feature vectors comprised the coordinates of the GTV centroids and one of two shape descriptors. One shape descriptor was based on radial distances between the GTV centroid and 614 GTV surface landmarks. The other was based on a spherical harmonic decomposition of these distances. Feature vectors over the course of therapy were described using static, linear, and mean models. The error of these models in forecasting GTV morphology was evaluated with leave-one-out cross-validation, and their accuracy was compared using Wilcoxon signed-rank tests. The effect of adjusting model parameters at 1, 2, 3, or 5 time points (adjustment points) was also evaluated. Results: The addition of a single adjustment point to the static model decreased the median error in forecasting the position of GTV surface landmarks by 1.2 mm (p<0.001). Additional adjustment points further decreased forecast error by about 0.4 mm each. The linear model decreased forecast error compared to the static model for feature vectors based on both shape descriptors (0.2 mm), while the mean model did so only for those based on the inter-landmark distances (0.2 mm). The decrease in forecast error due to adding adjustment points was greater than that due to model selection. Both effects diminished with subsequent adjustment points. Conclusion: Models of tumor morphology that include information from prior patients and/or prior treatment fractions are able to predict the tumor surface at each treatment fraction during radiation therapy. The predicted tumor morphology can be compared with patient anatomy or dose distributions, opening the possibility of anticipatory re-planning. American Legion Auxiliary Fellowship; The University of Texas Graduate School of Biomedical Sciences at Houston.

60 APPLIED LIFE SCIENCES↗

The potential of positron emission tomography for intratreatment dynamic lung tumor tracking: A phantom study

Purpose: This study aims to evaluate the potential and feasibility of positron emission tomography for dynamic lung tumor tracking during radiation treatment. The authors propose a center of mass (CoM) tumor tracking algorithm using gated-PET images combined with a respiratory monitor and investigate the geometric accuracy of the proposed algorithm. Methods: The proposed PET dynamic lung tumor tracking algorithm estimated the target position information through the CoM of the segmented target volume on gated PET images reconstructed from accumulated coincidence events. The information was continuously updated throughout a scan based on the assumption that real-time processing was supported (actual processing time at each frame ≈10 s). External respiratory motion and list-mode PET data were acquired from a phantom programmed to move with measured respiratory traces (external respiratory motion and internal target motion) from human subjects, for which the ground truth target position was known as a function of time. The phantom was cylindrical with six hollow sphere targets (10, 13, 17, 22, 28, and 37 mm in diameter). The measured respiratory traces consisted of two sets: (1) 1D-measured motion from ten healthy volunteers and (2) 3D-measured motion from four lung cancer patients. The authors evaluated the geometric accuracy of the proposed algorithm by quantifying estimation errors (Euclidean distance) between the actual motion of targets (1D-motion and 3D-motion traces) and CoM trajectories estimated by the proposed algorithm as a function of time. Results: The time-averaged error of 1D-motion traces over all trajectories of all targets was 1.6 mm. The error trajectories decreased with time as coincidence events were accumulated. The overall error trajectory of 1D-motion traces converged to within 2 mm in approximately 90 s. As expected, more accurate results were obtained for larger targets. For example, for the 37 mm target, the average error over all 1D-motion traces was 1.1 mm; and for the 10 mm target, the average error over all 1D-motion traces was 2.8 mm. The overall time-averaged error of 3D-motion traces was 1.6 mm, which was comparable to that of the 1D-motion traces. There were small variations in the errors between the 3D-motion traces, although the motion trajectories were very different. The accuracy of the estimates was consistent for all targets except for the smallest. Conclusions: The authors developed an algorithm for dynamic lung tumor tracking using list-mode PET data and a respiratory motion signal, and demonstrated proof-of-principle for PET-guided lung tumor tracking. The overall tracking error in phantom studies is less than 2 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geometric and dosimetric accuracy of dynamic tumor-tracking conformal arc irradiation with a gimbaled x-ray head

Purpose: The Vero4DRT system has the capability for dynamic tumor-tracking (DTT) stereotactic irradiation using a unique gimbaled x-ray head. The purposes of this study were to develop DTT conformal arc irradiation and to estimate its geometric and dosimetric accuracy. Methods: The gimbaled x-ray head, supported on an O-ring gantry, was moved in the pan and tilt directions during O-ring gantry rotation. To evaluate the mechanical accuracy, the gimbaled x-ray head was moved during the gantry rotating according to input command signals without a target tracking, and a machine log analysis was performed. The difference between a command and a measured position was calculated as mechanical error. To evaluate beam-positioning accuracy, a moving phantom, which had a steel ball fixed at the center, was driven based on a sinusoidal wave (amplitude [A]: 20 mm, time period [T]: 4 s), a patient breathing motion with a regular pattern (A: 16 mm, average T: 4.5 s), and an irregular pattern (A: 7.2–23.0 mm, T: 2.3–10.0 s), and irradiated with DTT during gantry rotation. The beam-positioning error was evaluated as the difference between the centroid position of the irradiated field and the steel ball on images from an electronic portal imaging device. For dosimetric accuracy, dose distributions in static and moving targets were evaluated with DTT conformal arc irradiation. Results: The root mean squares (RMSs) of the mechanical error were up to 0.11 mm for pan motion and up to 0.14 mm for tilt motion. The RMSs of the beam-positioning error were within 0.23 mm for each pattern. The dose distribution in a moving phantom with tracking arc irradiation was in good agreement with that in static conditions. Conclusions: The gimbal positional accuracy was not degraded by gantry motion. As in the case of a fixed port, the Vero4DRT system showed adequate accuracy of DTT conformal arc irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Breast Volume on Treatment Reproducibility on a Tomotherapy Unit in the Treatment of Breast Cancer

Purpose: To determine whether the volume of a patient's breast is correlated with reliable daily setup in treatment of breast cancer with a helical tomotherapy treatment unit. Methods and Materials: Thirty-six consecutive patients with breast cancer were treated on a helical tomotherapy unit. During simulation, kilovoltage CT images were obtained for treatment planning. These were fused with daily megavoltage CT scans, and after setup based on skin marks and laser alignment the necessary shifts were carried out. The magnitude of daily shifts (in millimeters) was retrospectively obtained from the daily image fusions, and the breast volume was obtained from the treatment plan. A total of 873 fusion scans were reviewed. Random error for absolute and directional daily shifts was evaluated for correlation to volume. Variation over time was also evaluated. Results: Mean (SD) random shift for all patients in the lateral, longitudinal, and vertical directions was 2.7 (2.0), 3.1 (1.5), and 3.2 (2.6) mm, respectively. Mean (SD) absolute distance shifted was 6.0 (3.5) mm. There was no significant correlation between mean absolute or mean directional daily shift and breast volume (0.08, 0.08, 0.22, and 0.07, respectively). There was no correlation between setup variation and time. Conclusions: In this cohort, there was no correlation between breast volume and degree of daily shift. There was no correlation between time course and setup variation. Therefore, setup variation does not improve or degrade with repeated treatment setups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A simple soil mass correction for a more accurate determination of soil carbon stock changes

Abstract Agricultural soils can act as a sink for large quantities of soil organic carbon (SOC) but can also be sources of carbon to the atmosphere. The international standard for assessing SOC stock and measuring stock change stipulates fixed depth sampling to at least 30 cm. The tendency of bulk density (BD) to decrease with decreasing disturbance and increasing SOC concentration and the assumption of constant SOC and BD within this depth profile promotes error in the estimates of SOC stock. A hypothetical but realistic change in BD from 1.5 to 1.1 g cm −3 from successive fixed depth sampling to 30 cm underestimates SOC stock change by 17%. Significant effort has been made to evaluate and reduce this fixed depth error by using the equivalent soil mass (ESM) approach, but with limited adoption. We evaluate the error in SOC stock assessment and change generated from fixed depth measurements over time relative to the ESM approach and propose a correction that can be readily adopted under current sampling and analytical methods. Our approach provides a more accurate estimate of SOC stock accumulation or loss that will help incentivize management practice changes that reduce the environmental impacts of agriculture and further legitimize the accounting practices used by the emerging carbon market and organizations that have pledged to reduce their supply chain greenhouse gas (GHG) footprints.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-01: 3D-2D Image Registration for Target Localization in Spine Surgery: Comparison of Similarity Metrics Against Robustness to Content Mismatch

Purpose: In image-guided spine surgery, mapping 3D preoperative images to 2D intraoperative images via 3D-2D registration can provide valuable assistance in target localization. However, the presence of surgical instrumentation, hardware implants, and soft-tissue resection/displacement causes mismatches in image content, confounding existing registration methods. Manual/semi-automatic methods to mask such extraneous content is time consuming, user-dependent, error prone, and disruptive to clinical workflow. We developed and evaluated 2 novel similarity metrics within a robust registration framework to overcome such challenges in target localization. Methods: An IRB-approved retrospective study in 19 spine surgery patients included 19 preoperative 3D CT images and 50 intraoperative mobile radiographs in cervical, thoracic, and lumbar spine regions. A neuroradiologist provided truth definition of vertebral positions in CT and radiography. 3D-2D registration was performed using the CMA-ES optimizer with 4 gradient-based image similarity metrics: (1) gradient information (GI); (2) gradient correlation (GC); (3) a novel variant referred to as gradient orientation (GO); and (4) a second variant referred to as truncated gradient correlation (TGC). Registration accuracy was evaluated in terms of the projection distance error (PDE) of the vertebral levels. Results: Conventional similarity metrics were susceptible to gross registration error and failure modes associated with the presence of surgical instrumentation: for GI, the median PDE and interquartile range was 33.0±43.6 mm; similarly for GC, PDE = 23.0±92.6 mm respectively. The robust metrics GO and TGC, on the other hand, demonstrated major improvement in PDE (7.6 ±9.4 mm and 8.1± 18.1 mm, respectively) and elimination of gross failure modes. Conclusion: The proposed GO and TGC similarity measures improve registration accuracy and robustness to gross failure in the presence of strong image content mismatch. Such registration capability could offer valuable assistance in target localization without disruption of clinical workflow. G. Kleinszig and S. Vogt are employees of Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

Comparison of numerical techniques for integration of stiff ordinary differential equations arising in combustion chemistry

The efficiency and accuracy of several algorithms recently developed for the efficient numerical integration of stiff ordinary differential equations are compared. The methods examined include two general-purpose codes, EPISODE and LSODE, and three codes (CHEMEQ, CREK1D, and GCKP84) developed specifically to integrate chemical kinetic rate equations. The codes are applied to two test problems drawn from combustion kinetics. The comparisons show that LSODE is the fastest code currently available for the integration of combustion kinetic rate equations. An important finding is that an interactive solution of the algebraic energy conservation equation to compute the temperature does not result in significant errors. In addition, this method is more efficient than evaluating the temperature by integrating its time derivative. Significant reductions in computational work are realized by updating the rate constants (k = at(supra N) N exp(-E/RT) only when the temperature change exceeds an amount delta T that is problem dependent. An approximate expression for the automatic evaluation of delta T is derived and is shown to result in increased efficiency.

Radhakrishnan, K.↗

Runge-Kutta methods combined with compact difference schemes for the unsteady Euler equations

Recent development using compact difference schemes to solve the Navier-Stokes equations show spectral-like accuracy. A study was made of the numerical characteristics of various combinations of the Runge-Kutta (RK) methods and compact difference schemes to calculate the unsteady Euler equations. The accuracy of finite difference schemes is assessed based on the evaluations of dissipative error. The objectives are reducing the numerical damping and, at the same time, preserving numerical stability. While this approach has tremendous success solving steady flows, numerical characteristics of unsteady calculations remain largely unclear. For unsteady flows, in addition to the dissipative errors, phase velocity and harmonic content of the numerical results are of concern. As a result of the discretization procedure, the simulated unsteady flow motions actually propagate in a dispersive numerical medium. Consequently, the dispersion characteristics of the numerical schemes which relate the phase velocity and wave number may greatly impact the numerical accuracy. The aim is to assess the numerical accuracy of the simulated results. To this end, the Fourier analysis is to provide the dispersive correlations of various numerical schemes. First, a detailed investigation of the existing RK methods is carried out. A generalized form of an N-step RK method is derived. With this generalized form, the criteria are derived for the three and four-step RK methods to be third and fourth-order time accurate for the non-linear equations, e.g., flow equations. These criteria are then applied to commonly used RK methods such as Jameson's 3-step and 4-step schemes and Wray's algorithm to identify the accuracy of the methods. For the spatial discretization, compact difference schemes are presented. The schemes are formulated in the operator-type to render themselves suitable for the Fourier analyses. The performance of the numerical methods is shown by numerical examples. These examples are detailed. described. The third case is a two-dimensional simulation of a Lamb vortex in an uniform flow. This calculation provides a realistic assessment of various finite difference schemes in terms of the conservation of the vortex strength and the harmonic content after travelling a substantial distance. The numerical implementation of Giles' non-refelctive equations coupled with the characteristic equations as the boundary condition is discussed in detail. Finally, the single vortex calculation is extended to simulate vortex pairing. For the distance between two vortices less than a threshold value, numerical results show crisp resolution of the vortex merging.

Yu, Sheng-Tao↗