Search NASA⌕ Search

SEARCH · Search NASA

Results for “total ozone”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Total Ozone from the Ozone Monitoring System (OMI) using TOMS and DOAS Methods

The Ozone Monitoring Instrument (OMI) is the Dutch-Finnish contribution to NASA's EOS-Aura satellite scheduled for launch in January 2004. OMI is an imaging spectrometer that will measure the back-scattered Solar radiance in the wavelength range of 270 to 500 nm. The instrument provides near global coverage in one day with a spatial resolution of 13x24 square kilometers. OMI is a new instrument, with a heritage from TOMS, SBW, GOME, GOMOS and SCIAMACHY. OMI'S unique capabilities for measuring important trace gases and aerosols with a small footprint and daily global coverage, in conjunction with the other Aura instruments, will make a major contribution to our understanding of stratospheric and tropospheric chemistry and climate change. OMI will provide data continuity with the 23-year ozone record of TOMS. There are three ozone products planned for OMI: total column ozone, ozone profile and tropospheric column ozone. We are developing two different algorithms for total column ozone: one similar to the algorithm currently being used to process the TOMS data, and the other an improved version of the differential optical absorption spectroscopy (DOAS) method, which has been applied to GOME and SCIAMACHY data. The main reasons for starting with two algorithms for total ozone have to do with heritage and past experience; our long-term goal is to combine the two to develop a more accurate and reliable total ozone product for OMI. We will compare the performance of these two algorithms by applying both of them to the GOME data. We will examine where and how the results differ, and use the extensive TOMS-Dobson comparison studies to assess the performance of the DOAS algorithm.

Veefkind, J. P.↗

Contingency maneuver strategies for the Total Ozone Mapping Spectrometer-Earth Probe (TOMS-EP)

The Total Ozone Mapping Spectrometer-Earth Probe (TOMS-EP) is a polar-orbiting spacecraft designed to measure total ozone levels in the Earth's atmosphere. The nominal mission orbit is a 955-kilometer circular Sun-synchronous orbit with an ascending node mean local crossing time (MLT) between 11:02 a.m. and 11:25 a.m. These two mean local ascending node times constitute the boundaries of the MLT box for this mission. The MLT boundaries were chosen to maintain the Sun-to-Earth-to-vehicle orbit-normal (SVN) angle within a preselected set of seasonally independent boundaries. Because the SVN angle is seasonally dependent, but the MLT is not, contingency options for correcting the MLT of orbital states that fall outside of the required MLT range become time dependent. This paper focuses on contingency orbit adjustment strategies developed at the Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) during the mission planning phase of TOMS-EP. Time-dependent delta-V strategies are presented for correcting mission orbit states lying outside of the MLT range. Typically, passive control of the MLT drift rate can be used to restore the orbit state to the required MLT before a seasonal violation of SVN angle constraints can occur. Passive control of the MLT drift rate is obtained through adjustment of the semimajor axis and/or the inclination. The time between initial arrival on orbit at an 'out-of-the box' MLT state and violation of the SVN angle constraints is always less than or equal to 1 year. The choice of which parameter(s) to adjust is dictated by the duration of this time period, the desired mission lifetime, the delta-V cost, and operational constraints.

Kestler, James↗

Spatial variability of total ozone at high latitudes in winter

The spatial variability of total ozone at high latitudes in winter is explained by the vertical structure of planetary-scale waves. The location of the maximum in total ozone is governed by the phase shift with height of the waves, while the amplitude of the maximum depends on the phase and also on the vertical and horizontal mean-zonal ozone gradients.

Kurzeja, R. J.↗

Initial estimate of NOAA-9 SBUV/2 total ozone drift: Based on comparison with re-calibrated TOMS measurements and pair justification of SBUV/2

Newly recalibrated version 6 Total Ozone Mapping Spectrometer (TOMS) data are used as a reference measurement in a comparison of monthly means of total ozone in 10 degree latitude zones from SBUV/2 and the nadir measurements from TOMS. These comparisons indicate a roughly linear long-term drift in SBUV/2 total ozone relative to TOMS of about 2.5 Dobson units per year at the equator over the first three years of SBUV/2. The pari justification technique is also applied to the SBUV/2 measurements in a manner similar to that used for SBUV and TOMS. The higher solar zenith angles associated with the afternoon orbit of NOAA-9 and the large changes in solar zenith angle associated with its changing equator crossing time degrade the accuracy of the pair justification method relative to its application to SBUV and TOMS, but the results are consistent with the SBUV/2-TOMS comparisons, and show a roughly linear drift in SBUV/2 of 2.5 to 4.5 Dobson units per year in equatorial ozone.

Wellemeyer, C. G.↗

Northern hemisphere total ozone values from 1989-1993 determined with the NOAA-11 Solar Backscatter Ultraviolet (SBUV/2) instrument

Determinations of global total ozone amounts have been made from recently reprocessed measurements with the SBUV/2 on the NOAA-11 environmental satellite since January 1989. This data set employs a new algorithm and an updated calibration. Comparisons with total ozone amounts derived from a significant subset of the global network of Dobson spectrophotometers shows a 0.3% bias between the satellite and ground measurements for the period January 1989-May 1993. Comparisons with the data from individual stations exhibit differing degrees of agreement which could be due to the matchup procedures and also to the uncertainties in the Dobson data. The SBUV/2 data set discussed here traces the Northern Hemisphere total ozone from 1989 to the present, showing a marked decrease from the average of those years starting in the summer of 1992 and continuing into 1993, with an apparent returning to more normal levels in late 1993.

Planet, W. G.↗

Fine-Scale Comparison of TOMS Total Ozone Data with Model Analysis of an Intense Midwestern Cyclone

High-resolution (approx. 40 km) along-track total column ozone data from the Total Ozone Mapping Spectrometer (TOMS) instrument are compared with a high-resolution mesoscale numerical model analysis of an intense cyclone in the Midwestern United States. Total ozone increased by 100 DU (nearly 38%) as the TOMS instrument passed over the associated tropopause fold region. Complex structure is seen in the meteorological fields and compares well with the total ozone observations. Ozone data support the meteorological analysis showing that stratospheric descent was confined to levels above approx. 600 hPa; significant positive potential vorticity at lower levels is attributable to diabetic processes. Likewise, meteorological fields show that two pronounced ozone streamers extending north and northeastward into Canada at high levels are not bands of stratospheric air feeding into the cyclone; one is a channel of exhaust downstream from the system, and the other apparently previously connected the main cyclonic circulation to a southward intrusion of polar stratospheric air and advected eastward as the cut-off cyclone evolved. Good agreement between small-scale features in the model output and total ozone data underscores the latter's potential usefulness in diagnosing upper tropospheric/lower stratospheric dynamics and kinematics.

Olsen, Mark A.↗

Complementary information between UV and IR for remote sensing of total ozone

When infrared and ultraviolet measurements are available simultaneously with the same field of view, it is possible to minimize some of the errors in measuring the total ozone. The addition of the infrared technique to Total Ozone Mapping Spectrometer (TOMS) operation can aid in getting measurements of ozone in the nighttime and during the polar night. A radiometer with a channel in the window region around 11 microns, a channel in the 9-6 micron O sub 3 band, and three channels in the 15 micron CO sub 2 band should be adequate to retrieve total ozone. Such a radiometer could be designed to do cross track scanning. This combination of ultraviolet and infrared instruments could be flown on a geostationary or polar orbiting satellite.

Cuddapah, Prabhakara↗

The effect of bandwidth on filter instrument total ozone accuracy

The effect of the width and shape of the New Zealand filter instrument's passbands on measured total-ozone accuracy is determined using a numerical model of the spectral measurement process. The model enables the calculation of corrections for the 'bandwidth-effect' error and shows that highly attenuating passband skirts and well-suppressed leakage bands are at least as important as narrow half-bandwidths. Over typical ranges of airmass and total ozone, the range in the bandwidth-effect correction is about 2% in total ozone for the filter instrument, compared with about 1% for the Dobson instrument.

Basher, R. E.↗

Variability in total ozone associated with baroclinic waves

One-point regression maps of total ozone formed by regressing the time series of bandpass-filtered geopotential height data have been analyzed against Total Ozone Mapping Spectrometer data. Results obtained reveal a strong signature of baroclinic waves in the ozone variability. The regressed patterns are found to be similar in extent and behavior to the relative vorticity patterns reported by Lim and Wallace (1991).

Mote, Philip W.↗

Comment on 'Further interpretation of satellite measurements of Antarctic total ozone'

It is argued that the best explanation for the 1980-1982 Total Ozone Mapping Spectrometer (TOMS) data showing a decline in zonal monthly mean total ozone for Octobers between 1979 and 1985/86 for all latitudes south of 40 S (as reported by Stolarski and Schoeberl, 1986) is a near-cancellation between an ozone source and a newly developed chemical sink for ozone, with both initiated by the arrival of spring in the southern hemisphere. In a reply by Schoeberl and Stolarski, additional TOMS observations are reported which suggest that some uncompensated ozone loss may be occurring in the spring Antarctic in the most recent years. A significant change in the midlatitude ozone source appears to have occurred as well. The observations show the importance of the final warming in setting up the summertime ozone distribution.

Eliott, Scott↗

Combined Characterisation of GOME and TOMS Total Ozone Using Ground-Based Observations from the NDSC

Several years of total ozone measured from space by the ERS-2 GOME, the Earth Probe Total Ozone Mapping Spectrometer (TOMS), and the ADEOS TOMS, are compared with high-quality ground-based observations associated with the Network for the Detection of Stratospheric Change (NDSC), over an extended latitude range and a variety of geophysical conditions. The comparisons with each spaceborne sensor are combined altogether for investigating their respective solar zenith angle (SZA) dependence, dispersion, and difference of sensitivity. The space- and ground-based data are found to agree within a few percent on average. However, the analysis highlights for both Global Ozone Monitoring Experiment (GOME) and TOMS several sources of discrepancies, including a dependence on the SZA at high latitudes and internal inconsistencies.

Lambert, J.-C.↗

Low ozone amounts during 1992 - 1993 from Nimbus 7 and Meteor 3 total ozone mapping spectrometers

The global distribution of ozone during the October 31, 1978, to May 6, 1993, observing lifetime of the Nimbus 7 total ozone mapping spectrometer (TOMS) is described, with emphasis on the low ozone amounts observed during 1992 and 1993. Ozone amount time series are extended beyong May 6, 1993, to the end of July 1993 using preliminary Meteor 3 TOMS data. Time series for zonally averaged ozone amounts show that there has not been a significant shift in the seasonal patterns of ozone maxima and minima caused by the Mount Pinatubo eruption or by the onset of very low ozone values during 1992 and 1993. There has been a relatively slow, nearly linear decrease in the amount of ozone over the entire globe from 1979 to the end of 1991, with rates ranging from no change at the equator to a 4 - 6% decrease per decade at midlatitudes and a 10 - 12% decrease per decade at higher latitudes. After the eruption of Mount Pinatubo during June 1991, the ozone amount decreased in the equatorial latitudes (10 deg S to 10 deg N) for about 6 months (-10 Dobson units (DU) between 0 deg and 10 deg S and -3 DU between 0 deg and 10 deg N). During 1992 and continuing into 1993, the rate of ozone decrease deviated from the previously linear trend with the onset of changes that were large in comparison with the historical range of ozone values from 1979 to 1991. The first of the large decreases in ozone amount occurred earlier, in February 1990 to May 1990, at 50 deg - 70 deg N. At high northern latitudes, the 1993 decreased ozone amounts were about 12.5% below the envelope of historical values; at midlatitudes they were about 7% lower; and at low latitudes they were about 4% lower. Area-weighted averages in the northern and southern hemispheres show that most of the 1992 - 1993 ozone losses have occurred in the northern hemisphere. The 1993 global average (70 deg S to 70 deg N) ozone amount is 3% below the 1979 to 1991 minimum, 5% below the historical envelope in the northern hemisphere, and near the lower boundary of the historical envelope in the southern hemisphere. In the 70 deg - 60 deg S latitude band, the ozone losses between 1979 and 1993 have reduced the annual minimum amount to values below those seen in the equatorial regions.

Herman, J. R.↗

First comparison of simultaneous IRIS, BUV, and ground-based measurements of total ozone

In the present paper, the zonally-averaged global distribution of total ozone obtained simultaneously from different measurements are compared with respect to differences in the measured latitudinal and seasonal variations of total ozone. Emphasis is placed on systematic discrepancies that appear to be related to differences in the sensing methodologies or instruments. While the zonal averages of the IRIS and BUV satellite techniques agree quite well at low latitudes, the results are consistently higher for IRIS than for BUV above mid-latitudes in both the Northern and Southern Hemispheres. The BUV and ground-based ultraviolet averages agree better with each other than with infrared IRIS measurements.

Prior, E. J.↗

Investigation of the effect of atmospheric dust on the determination of total ozone from the earth's ultraviolet reflectivity measurements, 2

Results of a detailed analysis of the simulated measurements for the BUV (Nimbus-4) configuration are described by using a total-ozone estimation procedure. A set of recommendations are discussed for increasing the accuracy and confidence level of the total ozone values estimated from the measurements of the earth's ultraviolet reflectivity at five different wavelengths (BUV configuration). A tentative procedure is also considered for the estimation of total ozone from measurements of reflectivity at six different wavelengths specified in the SBUV/TOMS (Nimbus-G) configuration.

Dave, J. V.↗

Low frequency oscillations in total ozone measurements

Low frequency oscillations with periods of approximately one to two months are found in eight years of global grids of total ozone data from the Total Ozone Mapping Spectrometer (TOMS) satellite instrument. The low frequency oscillations corroborate earlier analyses based on four years of data. In addition, both annual and seasonal one-point correlation maps based on the 8-year TOMS data are presented. The results clearly show a standing dipole in ozone perturbations, oscillating with 35 to 50 day periods over the equatorial Indian Ocean-west Pacific region. This contrasts with the eastward moving dipole reported in other data sets. The standing ozone dipole appears to be a dynamical feature associated with vertical atmospheric motions. Consistent with prior analyses based on lower stratospheric temperature fields, large-scale standing patterns are also found in the extratropics of both hemispheres, correlated with ozone fluctuations over the equatorial west Pacific. In the Northern Hemisphere, a standing pattern is observed extending from the tropical Indian Ocean to the north Pacific, across North America, and down to the equatorial Atlantic Ocean region. This feature is most pronounced in the NH summer.

Gao, X. H.↗

Low-frequency oscillations in total ozone measurements

Low frequency oscillations with periods of approximately one to two months are found in eight years of global grids of total ozone data from the Total Ozone Mapping Spectrometer (TOMS) satellite instrument. The low frequency oscillations corroborate earlier analyses based on four years of data. In addition, both annual and seasonal one-point correlation maps based on the 8-year TOMS data are presented. The results clearly show a standing dipole in ozone perturbations, oscillating with 35 to 50 day periods over the equatorial Indian Ocean-west Pacific region. This contrasts with the eastward moving dipole reported in other data sets. The standing ozone dipole appears to be a dynamical feature associated with vertical atmospheric motions. Consistent with prior analyses based on lower stratospheric temperature fields, large-scale standing patterns are also found in the extratropics of both hemispheres, correlated with ozone fluctuations over the equatorial west Pacific. In the Northern Hemisphere, a standing pattern is observed extending from the tropical Indian Ocean to the north Pacific, across North America, and down to the equatorial Atlantic Ocean region. This feature is most pronounced in the NH summer.

Gao, X. H.↗

Small-Scale Tropopause Dynamics and TOMS Total Ozone

This project used Earth Probe Total Ozone Mapping Spectrometer (EP TOMS) along-track ozone retrievals, in conjunction with ancillary meteorological fields and modeling studies, for high resolution investigations of upper troposphere and lower stratosphere dynamics. Specifically, high resolution along-track (Level 2) EP TOMS data were used to investigate the beautiful fine-scale structure in constituent and meteorological fields prominent in the evolution of highly non-linear baroclinic storm systems. Comparison was made with high resolution meteorological models. The analyses provide internal consistency checks and validation of the EP TOMS data which are vital for monitoring ozone depletion in both polar and midlatitude regions.

Stanford, John L.↗

The effect of surface reflection and clouds on the estimation of total ozone from satellite measurements

The total amount of ozone in a vertical column is being measured by Nimbus 4 and 7 observations of the intensity of ultraviolet sunlight scattered from the earth. The algorithm for deriving the amount of ozone from the observations uses the assumption that the surface reflects the light isotropically and the albedo is independent of wavelength. The effects of anisotropic surfaces and clouds on the estimate of total ozone are computed for models of the earth-atmosphere system.

Fraser, R. S.↗