Search NASA⌕ Search

SEARCH · Search NASA

Results for “total temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Combined pressure and temperature distortion effects on internal flow of a turbofan engine

An additional data base for improving and verifying a computer simulation developed by an engine manufacturer was obtained. The multisegment parallel compressor simulation was designed to predict the effects of steady-state circumferential inlet total-pressure and total-temperature distortions on the flows into and through a turbofan compression system. It also predicts the degree of distortion that will result in surge of the compressor. The effect of combined 180 deg square-wave distortion patterns of total pressure and total temperature in various relative positions is reported. The observed effects of the combined distortion on a unitary bypass ratio turbofan engine are presented in terms of total and static pressure profiles and total temperature profiles at stations ahead of the inlet guide vanes as well as through the fan-compressor system. These observed profiles are compared with those predicted by the complex multisegment model. The effects of relative position of the two components comprising the combined distortion on the degree resulting in surge are discussed. Certain relative positions required less combined distortion than either a temperature or pressure distortion by itself.

Braithwaite, W. M.↗

Turbulent wake/shock interaction at Mach 6

The paper presents measurements of mean pitot, static pressure and total temperature profiles for a two-dimensional turbulent wake in the vicinity and downstream of intersection with a shock/expansion wave system. The wake centerline Mach number, velocity, and total temperature distributions indicated that the shock increased turbulent mixing, while the expansion field that followed the shock decreased mixing. The overall effect of the shock/expansion wave interaction was to increase mixing for shock angles 15 deg and less for the shock generator geometry used in the present study. Wake growth rates determined from the total temperature profiles confirmed the increased turbulent mixing effect of the shock. These data could be used to validate nonquilibrium turbulence modeling and numerical solution of the time-averaged Navier-Stokes equations.

Walsh, M. J.↗

LWC and Temperature Effects on Ice Accretion Formation on Swept Wings at Glaze Ice Conditions

An experiment was conducted to study the effect of liquid water content and temperature on the critical distance in ice accretion formation on swept wings at glaze ice conditions. The critical distance is defined as the distance from the attachment line to tile beginning of the zone where roughness elements develop into glaze ice feathers. A baseline case of 150 mph, 25 F, 0.75 g/cu m. Cloud Liquid Water Content (LWC) and 20 micrometers in Water Droplet Median Volume Diameter (MVD) was chosen. Icing runs were performed on a NACA 0012 swept wing tip at 150 mph and MVD of 20 micrometers for liquid water contents of 0.5 g/cu m, 0.75 g/cu m, and 1.0 g/cu m, and for total temperatures of 20 F, 25 F and 30 F. At each tunnel condition, the sweep angle was changed from 0 deg to 45 deg in 5 deg increments. Casting data, ice shape tracings, and close-up photographic data were obtained. The results showed that decreasing the LWC to 0.5 g/cu m decreases the value of the critical distance at a given sweep angle compared to the baseline case, and starts the formation of complete scallops at 30 sweep angle. Increasing the LWC to 1.0 g/cu m increases the value of the critical distance compared to the baseline case, the critical distance remains always above 0 millimeters and complete scallops are not formed. Decreasing the total temperature to 20 F decreases the critical distance with respect to the baseline case and formation of complete scallops begins at 25 deg sweep angle. When the total temperature is increased to 30 F, bumps covered with roughness elements appear on the ice accretion at 25 deg and 30 deg sweep angles, large ice structures appear at 35 deg and 40 deg sweep angles, and complete scallops are formed at 45 deg sweep angle.

Vargas, Mario↗

Calibration of sonic valves for the laminar flow control, leading-edge flight test

Sonic needle valves were calibrated to measure and control airflow in the suction system for the leading-edge flight test. The procedure and results for the calibration flow test of 4:41 flight valves are given. Mass-flow rates, which ranged from 0.001 to 0.012 lbm/sec, and maximum back pressure were measured for total temperatures from -30 F to 75 F and total pressures from 120 to 540 psf. Correlating equations are obtained for mass-flow rate as a function of total pressure, total temperature, and valve opening length. The most important aspect of flow measurement and control is found to be the measurement of valve opening length.

Petley, D. H.↗

Pitot-Pressure Measurements in Flow Fields Behind a Rectangular Nozzle with Exhaust Jet for Free-Stream Mach Numbers of 0.00, 0.60, and 1.20

An investigation has been conducted in the Langley 16-Foot Transonic Tunnel to measure the flow field in and around the jet exhaust from a nonaxisymmetric nozzle configuration. The nozzle had a rectangular exit with a width-to-height ratio of 2.38. Pitot-pressure measurements were made at five longitudinal locations downstream of the nozzle exit. The maximum distance downstream of the exit was about 5 nozzle heights. These measurements were made at free-stream Mach numbers of 0.00, 0.60, and 1.20 with the nozzle operating at a ratio of nozzle total pressure to free-stream static pressure of 4.0. The jet exhaust was simulated with high-pressure air that had an exit total temperature essentially equal to the free-stream total temperature.

Putnam, L. E.↗

Anomalous Net Biome Exchange Over Amazonian Rainforests Induced by the 2015/16 El Niño: Temperature-dominated Total Flux but Soil Dryness-Shaped Spatial Pattern

The magnitude and spatial pattern of anomalous net biome exchange (NBE) induced by the 2015/16 El Niño over Amazonian rainforests remain uncertain. We here investigated them using multi-model posterior NBE products in the Orbiting Carbon Observatory-2 (OCO-2) version 10 modeling intercomparison project. Results suggest that relative to the annual NBE average in 2017/18, larger anomalous carbon release occurred over the eastern and northern Amazonian rainforests in 2015/16, with a total flux of approximately 0.4 PgC yr−1 after assimilating satellite-observed column CO2 concentrations (XCO2) over land. We further find that this anomalous spatial pattern was predominantly determined by soil dryness, while the total positive NBE anomaly was dominated by higher temperature with its contribution of approximately 68~70%. We believe that atmospheric inversions assimilating more satellite-observed XCO2 in future can provide us more comprehensive understanding how Amazonian rainforests cope with the abiotic stresses induced by El Niño events.

Jun Wang↗

Method to Measure Total Noise Temperature of a Wireless Receiver During Operation

A method has been developed to measure the total effective noise power in a GPS receiver, including contributions from the system temperature, the antenna temperature, interference, lossy components, etc. A known level of noise is periodically injected before the preamplifier during normal tracking, with a switch set to a very low duty cycle, so that there is insignificant signal loss for the GPS signals being tracked. Alternately, a signal of known power may be injected. The coupling port is fed with a switch that can be controlled from the receiver s digital processing section. The switch can connect the coupling port to a noise or signal source at a known power level. The combined system noise is measured, and nearly continuous noise calibrations are made. The effect from injected noise/signals on the performance of the GPS receiver can be less than 0.01 dB of SNR loss. Minimal additional components are required. The GPS receiver is used to measure the SNRs required to solve for the noise level. Because this measurement is referenced to the preamplifier input, it is insensitive to variations in the receiver gain.

Young, Lawrence E.↗

Tropospheric- Stratospheric Measurement Studies Summary

The two high altitude aircraft, ER-2 NASA #706 and 709 and the DC-8 NASA #717 are in active use in several programs of upper atmospheric research to study polar ozone changes, stratospheric-tropospheric exchange processes and atmospheric effects of aviation aircraft. The ER-2 has participated in seven major missions which mainly concentrated on vortex dynamics and the large losses of Ozone in the Polar regions (Ozone hole) observed in the spring. One mission verified the complex dynamical chemical and physical processes that occur during sunrise and sunset. Stratospheric Tracers of Atmospheric Transport (STRAT) obtained background measurements using the full ER-2 suite of instruments. Photochemistry of Ozone Loss in the Arctic Region in Summer (POLARIS) in 1997 assisted in understanding the mid-latitude and Arctic Ozone losses during the Northern Summer. The DC-8 with the Meteorological Measurement System (MMS) has participated in the Subsonic Aircraft: Cloud and Contrail Effects Special Study (SUCCESS), in 1996 and the Subsonic assessment Ozone and Nitrogen oxide experiment (SONEX) in 1997 missions. The MMS with its sophisticated software accurately measures ground speed and attitude, in-situ static and dynamic pressure total temperature, which are used to calculate the three dimensional wind fields, static pressure, temperature and turbulence values to meteorological accuracy. The meteorological data is not only of interest for its own sake in atmospheric dynamical processes such as mountain waves and flux measurements; but is also required by other ER-2 experiments that simultaneously measure water vapor, O3, aerosols, NO, HCl, CH4, N2O, ClO, BrO, CO2, NOy, HOx and temperature gradients. MMS products are extensively used to assist in the interpretation of their results in understanding the importance of convective effects relative to in-situ chemical changes, as may be noted by examining the list of references attached. The MMS consists of three subsystems: (a) aircraft instrumentation, inertial navigation system (INS), static and dynamic pressure taps, (b) additional dedicated instrumentation measuring angle of attack, yaw, total temperature, and a GPS which on the DC-8 measures position, velocity and attitude (c) an on board data, storage and computing acquisition system. This instrumentation and the associated software requires both an on-going laboratory ground calibration procedure for the total air temperature, static and total pressure inputs, verification of the INS dynamic response and also extensive air measurements and intercomparisons which ultimately verify and calibrate the complete system and its software. More than the usual accuracy is required because of the near cancellation occurring in the difference between the ground speed and true airspeed vectors used to give the wind vector. In the past year we have redesigned, recalibrated and used the MMS system on the NASA DC-8 that was previously used in the SUCCESS mission for the SONEX mission. Two papers were co-authored based on SUCCESS flights. Several reports and handouts were written for SONEX. Calibrations of the DC-8 pressure transducer temperature measuring thermistors was completed and an extensive analysis spanning several years of data files of the DC-8 Rosemount pressure transducer calibrations was done.

Browen, Stuart W.↗

Turbulence measurements in shock induced flows

Turbulence measurements have been made in the incident and reflected flows of a shock tube. For the incident flow, M = 0.47 and Re/in. between 25,000 and 170,000 whereas in the reflected region M = 0.15 and Re/in. is between 12,000 and 85,000. Hot wire anemometers have been used to measure mass flux and total temperature fluctuations. In the incident flow mass flux and total temperatures averaged 1.2 percent and 0.5 percent respectively. The reflected shock amplified the turbulence intensities by approximately a factor of three. In general the intensities decreased with increasing flow Reynolds numbers.

Trolier, J. W.↗

Effects of Unsteady Flow Interactions on the Performance of a Highly-Loaded Transonic Compressor Stage

The primary focus of this paper is to investigate the loss sources in an advanced GE transonic compressor design with high reaction and high stage loading. This advanced compressor has been investigated both experimentally and analytically in the past. The measured compressor efficiency is significantly lower than the efficiency calculated with various existing tools based on RANS and URANS. The general understanding is that some important flow physics in this modern compressor design are not represented in the current tools. To pinpoint the source of the efficiency miss, an advanced test with detailed flow traverse was performed for the front one and a half stage at the NASA Glenn Research Center. In the present paper, a Large Eddy Simulation (LES) is employed to determine whether a higher-fidelity simulation can pick up any additional flow physics that can explain past efficiency miss with RANS and URANS. The results from the Large Eddy Simulation were compared with the NASA test results and the GE interpretation of the test data. LES calculates lower total pressure and higher total temperature on the pressure side of the stator, resulting in large loss generation on the pressure side of the stator. On the other hand, existing tools based on the RANS and URANS do not calculate this high total temperature and low total pressure on the pressure side of the stator. The calculated loss through the stator from LES seems to match the measured data and the GE data interpretation. Detailed examination of the unsteady flow field from LES indicates that the accumulation of high loss near the pressure side of the stator is due to the interaction of the rotor wake with the stator blade. The strong rotor wake interacts quite differently with the pressure side of the stator than with the suction side of the stator blade. The concave curvature on the pressure side of the stator blade increases the mixing of the rotor wake with the pressure side boundary layer significantly. On the other hand, the convex curvature on the suction side of the stator blade decreases the mixing and the suction side blade boundary layer remains thin. The jet velocity in the rotor wake in the stator frame seems to magnify the curvature effect in addition to inviscid redistribution of wake fluid toward the pressure side of the blade.

LES↗

Operating envelope charts for the Langley 0.3-meter transonic cryogenic wind tunnel

To take full advantage of the unique Reynolds number capabilities of the 0.3-meter Transonic Cryogenic Tunnel (0.3-m TCT) at the NASA Langley Research Center, it was designed to accommodate test sections other than the original, octagonal, three-dimensional test section. A 20- by 60-cm two-dimensional test section was installed in 1976 and was extensively used, primarily for airfoil testing, through the fall of 1984. The tunnel was inactive during 1985 so that a new test section and improved high speed diffuser could be installed in the tunnel circuit. The new test section has solid adaptive top and bottom walls to reduce or eliminate wall interference for two-dimensional testing. The test section is 33- by 33-cm in cross section at the entrance and is 142 cm long. In the planning and running of past airfoil tests in the 0.3-m TCT, the use of operating envelope charts have proven very useful. These charts give the variation of total temperature and pressure with Mach number and Reynolds number. The operating total temperature range of the 0.3-m TCT is from about 78 K to 327 K with total pressures ranging from about 17.5 psia to 88 psia. This report presents the operating envelope charts for the 0.3-m TCT with the adaptive wall tes t section installed. They were all generated based on a 1-foot chord model. The Mach numbers vary from 0.1 to 0.95.

Rallo, R. A.↗

High-Spatial-Resolution OH PLIF Visualization in a Cavity-Stabilized Ethylene-Air Turbulent Flame

High-spatial-resolution OH planar laser-induced fluorescence was measured for a premixed ethylene-air turbulent flame in an electrically-heated Mach 2 continuous-flow facility (University of Virginia Supersonic Combustion Facility, Configuration E.) The facility comprised a Mach 2 nozzle, an isolator with flush-wall fuel injectors, a combustor with optical access, and an extender. The flame was anchored at a cavity flameholder with a backward-facing step of height 9 mm. The temperature-insensitive Q1(8) transition of OH was excited using laser light of wavelength 283.55 nm. A spatial filter was used to create a laser sheet approximately 25 microns thick based on full-width at half maximum (FWHM). Extension tubes increased the magnification of an intensified camera system, achieving in-plane resolution of 40 microns based on a 50% modulation transfer function (MTF). The facility was tested with total temperature 1200 K, total pressure 300 kPa, local fuel/air equivalence ratios of approximately 0.4, and local Mach number of approximately 0.73 in the combustor. A test case with reduced total temperature and another with reduced equivalence ratio were also tested. PLIF images were acquired along a streamwise plane bisecting the cavity flameholder, from the backward facing step to 120 mm downstream of the step. The smallest observed features in the flow had width of approximately 110 microns. Flame surface density was calculated for OH PLIF images.

Geipel, Clayton M.↗

Combined pressure and temperature distortion effects on internal flow of a turbofan engine

The flow characteristics obtained experimentally for the compression of a 2-spool TF30-P-3 turbofan engine operating with 180 grad combined pressure and temperature distortion in the inlet flow are presented. The analytical model (Mazzawy and Banks, 1976), 'tuned' during Lewis testing, was used for pretest predictions of the effects that these distortions would have on the engine flow characteristics and the limiting distortion values. The effect of inlet flow distortion on the performance of the engine is discussed, including: (1) the flow between a screen mounted in the inlet duct and the inlet guide vanes; (2) the flow through the compression system; and (3) the effects of the combined distortion and its orientation on the compressor stability limits. It is concluded that the model used in this program was capable of predicting the effects of total pressure, total temperature and combined total pressure-total temperature distortions in terms of flow profiles, inlet flow angles and attenuation of the distortions through the compressor system. It was also capable of predicting the trends of the limiting values experienced with various orientations of the combined distortions.

Braithwaite, W. M.↗

Observational and theoretical temperatures for a total lunar eclipse

Temperature profiles from seven regions of the moon were recorded during a total eclipse using an infrared radiometer and telescope. The eclipse was visible from beginning to end. Target areas chosen range from mare areas to mountainous highlands. Theoretical temperature curves were calculated using a thermophysical model in which the lunar material properties are variable. These curves are compared with the experimental data. A description of the instrumentation, observations, calibration, signal reduction, and the theoretical model is given. The results show excellent agreement between the observational and theoretical temperatures during the eclipse. The apparent differences between the observed and calculated temperatures during pre- and post-eclipse are minimal after directional radiation is taken into account.

Fountain, W. F.↗

Free-flight Performance of 16-inch-diameter Supersonic Ram-jet Units II : Five Units Designed for Combustion-chamber-inlet Mach Number of 0.16 at Free-stream Mach Number of 1.60 (units B-1, B-2, B-3, B-4, and B-5) /c Wesley E. Messing and Scott H. S

Free-flight performance of five 16-inch-diameter ram-jet units was determined over range of free-stream Mach numbers of 0.50 to 1.86 and gas total-temperature ratios between 1.0 and 6.1 Time histories of performance data are presented for each unit. Correlations illustrate effect of free-stream Mach number and gas total-temperature ratio on diffuser total-pressure recovery, net-thrust coefficient, and external drag coefficient. One unit had smooth steady burning throughout the entire flight and encountered a maximum free-stream Mach number of 1.86 with a net acceleration of approximately 4.2 g's.

COMBUSTION - RAM-JET ENGINES↗

Computer program determines gas flow rates in piping systems

Computer program calculates the steady state flow characteristics of an ideal compressible gas in a complex piping system. The program calculates the stagnation and total temperature, static and total pressure, loss factor, and forces on each element in the piping system.

Franke, R.↗

Loading and heating of a large flat plate at Mach 7 in the Langley 8-foot high-temperature structures tunnel

Surface pressure and cold-wall heating rate distributions (wall-temperature to total-temperature ratio approximately 0.2) were obtained on a large, flat calibration panel at a nominal Mach number of 7 in an 8-foot high-temperature structures tunnel. Panel dimensions were 42.5 by 60.0 in. Test objectives were: (1) to map available flat-plate loading and heating provided by the facility and (2) to determine effectiveness of leading-edge bluntness, boundary-layer trips, and aerodynamic fences in generating a uniform, streamwise turbulent flow field over the test surface of a flat-sided panel holder.

Deveikis, W. D.↗