Search NASA⌕ Search

SEARCH · Search NASA

Results for “trace element detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Evolution of LIBS technology to mobile instrumentation for expediting firearm-related investigations at the laboratory and the crime scene

Gunshot residue (GSR) is one of the few forensic disciplines that lack accurate screening techniques. This study proposes using a mobile LIBS instrument to detect inorganic GSR and compares performance to a previously validated laboratory instrument. The mobile LIBS is designed with advanced configurations specifically for on-site GSR analysis, including a CMOS detector and a sampling chamber that holds up to six typical GSR collection devices with separate gas flow ports to prevent cross-contamination. A significant novelty of the portable instrument is its image magnification, which allows quick searching and visualization of GSR particle morphology. The single-particle imaging and elemental composition capability is one of a kind and offers superior confirmatory features for GSR. The mobile LIBS performance was evaluated for residues collected from the hands of shooters (100 samples) and non-shooters (200 background samples), analyzed sequentially by the mobile instrument and then the laboratory instrument. Accuracies better than 98.8% were obtained by both instruments, demonstrating their suitability for trace IGSR detection from skin specimens. Implementation of this methodology is anticipated to drastically speed up response times (i.e., from several hours per sample by standard SEM-EDS practice to a few minutes by LIBS). The screening methods can be easily incorporated into workflows to improve decision-making processes at the crime scene and laboratory settings, reduce backlogs, and improve case management.

47 OTHER INSTRUMENTATION↗

THE GLOBULAR CLUSTER SYSTEM IN M87: A WIDE-FIELD STUDY WITH CFHT/MEGACAM

Canada-France-Hawaii Telescope Megacam data in (g', r', i') are used to obtain deep, wide-field photometry of the globular cluster system (GCS) around M87. A total of 6200 GCs brighter than i' = 23.0 (roughly equivalent to M{sub I} = -8.5) are included in the study, essentially containing almost the entire bright half of the total GC population in the galaxy. The classic bimodal metal-poor and metal-rich sequences of GCs show up clearly. While the spatial distribution of the GCs can be traced detectably outward to R {sub gc} {approx_equal} 100 kpc and perhaps further, the blue, metal-poor subpopulation is very much more spatially extended than the red subpopulation. Both the red and blue GC subsystems have radial metallicity gradients, where mean heavy-element abundance scales with a projected galactocentric distance as Z {approx} R {sup -0.12} (blue) and R {sup -0.17} (red). The blue sequence exhibits a strongly significant mass/metallicity relation (MMR) in which the mean metallicity gradually increases with cluster luminosity as Z {approx} L {sup 0.25+}-{sup 0.05} for the luminosity range M{sub I} {approx}< -10 and the assumption of a constant M/L. However, this relation is also clearly nonlinear: fainter than this level, the sequence is more nearly vertical. This mass/metallicity trend can be understood as the result of self-enrichment within the most massive metal-poor GCs during their formation. The red sequence formally exhibits a negatively sloped MMR, but the numerical solutions and tests show that this red-GC slope is not very significant. In giant elliptical galaxies, the red GCs are likely to represent a broad composite population formed during several major starbursts. If so, the red sequence might display a population-based MMR that could in principle be either positive or negative.

79 ASTRONOMY AND ASTROPHYSICS↗

Data Measured on Water Collected from Fall River Springs, California

In October 1997 field collection of water emerging from large volume springs located at the headwater of Fall River in northeastern California resulted in the measurement of stable isotope, radiocarbon, tritium, and dissolved noble gases. This work was follow-on to previous studies on similar spring systems in Hat Creek Valley and surrounding Mt. Shasta in northern California (Rose and Davisson, 1996; Rose et al., 1996; Davisson and Rose, 1997). The data for Fall River springs was never formally published and is therefore tabulated in Table 1 in order to be recorded in public record. These studies, along with many parallel and subsequent ones using isotopes and elemental concentrations, are all related to the general research area of tracing sources and quantifying transport times of natural and man-made materials in the environment. This type of research has direct relevance in characterizing environmental contamination, understanding resource development and protection, designing early detection in WMD related terrorism, and application in forensics analysis.

07 ISOTOPE AND RADIATION SOURCES↗

Data measured on water collected from eastern Mojave Desert, California

In March of 2000 field collection of water from the Eastern Mojave Desert resulted in the measurement of stable isotope, radiocarbon, tritium, and limited dissolved noble gases. This work was follow-on to previous studies on similar systems in southern Nevada associated with the Nevada Test Site (Davisson et al., 1999; Rose and Davisson, 2003). The data for groundwater from wells and springs was never formally published and is therefore tabulated in Table 1 in order to be recorded in public record. In addition 4 years of remote precipitation data was collected for stable isotopes and is included in Table 2. These studies, along with many parallel and subsequent ones using isotopes and elemental concentrations, are all related to the general research area of tracing sources and quantifying transport times of natural and man-made materials in the environment. This type of research has direct relevance in characterizing environmental contamination, understanding resource development and protection, designing early detection in WMD related terrorism, and application in forensics analysis.

07 ISOTOPE AND RADIATION SOURCES↗

A diamond anvil cell for x-ray fluorescence measurements of trace elements in fluids at high pressure and high temperature

We present a new diamond anvil cell (DAC), hereafter called the fluoX DAC, dedicated for x-ray fluorescence (XRF) analysis of trace elements in fluids under high pressure and high temperature to 10 GPa and 1273 K at least. This new setup has allowed measurement of Rb, Sr, Y, Zr, with concentrations of 50 ppm to 5.6 GPa and 1273 K. The characteristics of the fluoX DAC consist in an optimized shielding and collection geometry in order to reduce the background level in XRF spectrum. Consequently, minimum detection limits of 0.3 ppm were calculated for the abovementioned elements in this new setup. This new DAC setup coupled to the hard x-rays focusing beamline ID22 (ESRF, France) offers the possibility to analyze in situ at high pressure and high temperature, ppm level concentrations of heavy elements, rare earth elements, and first transition metals, which are of prime importance in geochemical processes. The fluoX DAC is also suitable to x-ray diffraction over the same high pressure-temperature range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The impact of CO2 on shallow groundwater chemistry: observations at a natural analog site and implications for carbon sequestration

In a natural analog study of risks associated with carbon sequestration, impacts of CO{sub 2} on shallow groundwater quality have been measured in a sandstone aquifer in New Mexico, USA. Despite relatively high levels of dissolved CO{sub 2}, originating from depth and producing geysering at one well, pH depression and consequent trace element mobility are relatively minor effects due to the buffering capacity of the aquifer. However, local contamination due to influx of saline waters in a subset of wells is significant. Geochemical modeling of major ion concentrations suggests that high alkalinity and carbonate mineral dissolution buffers pH changes due to CO{sub 2} influx. Analysis oftrends in dissolved trace elements, chloride, and CO2 reveal no evidence of in-situ trace element mobilization. There is clear evidence, however, that As, U, and Pb are locally co-transported into the aquifer with CO{sub 2}-rich saline water. This study illustrates the role that local geochemical conditions will play in determining the effectiveness of monitoring strategies for CO{sub 2} leakage. For example, if buffering is significant, pH monitoring may not effectively detect CO2 leakage. This study also highlights potential complications that CO{sub 2}carrier fluids, such as saline waters, pose in monitoring impacts ofgeologic sequestration.

58 GEOSCIENCES↗

Hitomi observations of the LMC SNR N 132 D: Highly redshifted X-ray emission from iron ejecta

Here, we present Hitomi observations of N 132 D, a young, X-ray bright, O-rich core-collapse supernova remnant in the Large Magellanic Cloud (LMC). Despite a very short observation of only 3.7 ks, the Soft X-ray Spectrometer (SXS) easily detects the line complexes of highly ionized S K and Fe K with 16–17 counts in each. The Fe feature is measured for the first time at high spectral resolution. Based on the plausible assumption that the Fe K emission is dominated by He-like ions, we find that the material responsible for this Fe emission is highly redshifted at ~800 km s –1 compared to the local LMC interstellar medium (ISM), with a 90% credible interval of 50–1500 km s –1 if a weakly informative prior is placed on possible line broadening. This indicates that the Fe emission arises from the supernova ejecta, and that these ejecta are highly asymmetric, since no blueshifted component is found. The S K velocity is consistent with the local LMC ISM, and is likely from swept-up ISM material. These results are consistent with spatial mapping that shows the He-like Fe concentrated in the interior of the remnant and the S tracing the outer shell. The results also show that even with a very small number of counts, direct velocity measurements from Doppler-shifted lines detected in extended objects like supernova remnants are now possible. Thanks to the very low SXS background of ~1 event per spectral resolution element per 100 ks, such results are obtainable during short pointed or slew observations with similar instruments. This highlights the power of high-spectral-resolution imaging observations, and demonstrates the new window that has been opened with Hitomi and will be greatly widened with future missions such as the X-ray Astronomy Recovery Mission (XARM) and Athena.

79 ASTRONOMY AND ASTROPHYSICS↗

A PIXE Study of Trace Elements in Sediments of Toledo River, Parana, Brazil

In this work we characterize sediment samples from several points in the River Toledo--PR, using the PIXE (Particle Induced X-Ray Emission) spectroscopy technique, in order to quantify trace elements in these samples aiming to provide information about pollution levels for trace elements. The samples were collected in six points of river, during a period of twelve months (12/2001 to 11/2002). The collected material was air-dried at room temperature and then pressed in pellets. The samples were irradiated under vacuum using a H beam of 2,39 MeV in the LAMFI (Laboratorio de Analises de Materials por Feixe Ionico). Produced x-rays were detected using a Si(Li) detector and a standard electronics. Using the Axil program to analyze PIXE spectra it was possible to identify and quantify some elements present in the samples. A multi-elemental referenced material (Buffalo River sediment--RM 8704) was used to validate the PIXE analysis with thick targets. Twelve months of monitoring of six river points were analyzed and these allowed us to identify 18 elements such as Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Zr e Pb. The following elements were monitored: V, Cr, Mn, Co, Ni, Cu, Zn e Pb.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lithological controls on soil geochemistry and clay mineralogy across Spodosols in the coastal temperate rainforest of southeast Alaska

The interaction of similar soil forming factors with different parent materials determines soil chemical weathering, influencing soil processes and properties. In the coastal temperate rainforests of southeast Alaska, Spodosols is the dominant soil order in well-drained parent materials regardless of the lithology. Yet, the role of lithology on chemical weathering, base cation depletion, and mineral transformation during pedogenesis remains elusive. Here, we established a lithosequence comprised of soils derived from tonalite, phyllite, slate, and metavolcanic rocks to test the hypothesis that despite the soils in southeast Alaska presenting similar taxonomy and morphology, the influence of lithology in chemical weathering intensity and mineralogy can be detected. We evaluated physicochemical properties, clay mineralogy, Fe-Al oxides, chemical weathering, and elemental mass balance on eleven Spodosols sampled along the lithosequence. We also propose a new weathering index, the Weathering Index for Spodosols (WISP), suitable to evaluate the weathering degree of soils with Al mobility and base-rich parent materials. This index fills a gap in traditional weathering indices that uses Al as an immobile element and/or does not evaluate the leaching of main base cations. We found the pedons across the lithosequence expressed similar physicochemical properties, with predominantly thick profiles, presenting andic properties, relatively thick spodic horizons, and thin E horizons. Podzolization imposed similar mineral transformation trends, mainly dissolution of chlorite, mica alteration to interstratified mica-vermiculite, and formation of smectite in E horizons. Kaolinite was detected in the soils from all lithologies, but only in trace amounts in phyllite soils. Fe oxides depth distribution was similar but with a higher concentration in the slate (44.5 ± 4.2 g/kg), followed by metavolcanic (31.6 ± 4.0 g/kg), phyllite (27.9 ± 3.8 g/kg), and tonalite soils (19.9 ± 5.7 g/kg) and predominantly as organometallic complexes (extracted by Na-pyrophosphate). The stronger weathering of chlorite and mica in the E horizons was reflected in larger losses of Mg and K, while Ca and Na were more depleted in the spodic horizons, suggesting plagioclase weathering. Slate soils were the most depleted in base cations, followed by phyllite, tonalite, and metavolcanic soils. The more depleted status of slate soils was supported by the higher WISP values (WISP = 62), followed by phyllite (WISP = 55), tonalite (WISP = 53), and metavolcanic soils (WISP = 45). Our results demonstrated that lithology controlled elemental depletion intensities, Fe oxide concentrations, and partially the clay fraction mineralogy in addition to podzolization acting as a dominant pedogenic process across all sites. These findings advance our understanding of the role of lithology on soil mineralogy/geochemistry that impacts critical soil functions, such as the soil carbon cycle, elemental fluxes, organo-mineral interactions, and solid-solution reactions.

54 ENVIRONMENTAL SCIENCES↗

Field Evaluation of Novel Approach for Obtaining Metal Emission Data (Subtask 4.24)

Over the past two decades, emissions of mercury, nonmercury metals, and acid gases from energy generation and chemical production have increasingly become an environmental concern. On February 16, 2012, the U.S. Environmental Protection Agency (EPA) promulgated the Mercury and Air Toxics Standards (MATS) to reduce mercury, nonmercury metals, and HCl emissions from coal-fired power plants. The current reference methods for trace metals and halogens are wet-chemistry methods, EPA Method (M) 29 and M26A, respectively. As a possible alternative to EPA M29 and M26A, the Energy & Environmental Research Center (EERC) has developed a novel multielement sorbent trap (ME-ST) method to be used to sample for trace elements and/or halogens. Testing was conducted at three different power plants, and the results show that for halogens, the ME-ST halogen (ME-ST-H) method did not show any significant bias compared to EPA M26A and appears to be a potential candidate to serve as an alternative to the reference method. For metals, the ME-ST metals (ME-ST-M) method offers a lower detection limit compared to EPA M29 and generally produced comparable data for Sb, As, Be, Cd, Co, Hg, and Se. Both the ME-ST-M and M29 had problems associated with high blanks for Ni, Pb, Cr, and Mn. Although this problem has been greatly reduced through improved trap design and material selection, additional research is still needed to explore possible longer sampling durations and/or selection of lower background materials before the ME-ST-M can be considered as a potential alternative method for all the trace metals listed in MATS.

20 FOSSIL-FUELED POWER PLANTS↗

Integrated approaches for reducing sample size for measurements of trace elemental impurities in plutonium by ICP-OES and ICP-MS

This study has demonstrated that bulk plutonium chemical analysis can be performed at small scales (\50 mg material) through three case studies. Analytical methods were developed for ICP-OES and ICP-MS instruments to measure trace impurities and gallium content in plutonium metals with comparable or improved detection limits, measurement accuracy and precision. In two case studies, the sample size has been reduced by 109, and in the third case study, by as much as 50009, so that the plutonium chemical analysis can be performed in a facility rated for lower-hazard and lower-security operations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

HELIUM ATMOSPHERES ON WARM NEPTUNE- AND SUB-NEPTUNE-SIZED EXOPLANETS AND APPLICATIONS TO GJ 436b

Warm Neptune- and sub-Neptune-sized exoplanets in orbits smaller than Mercury’s are thought to have experienced extensive atmospheric evolution. Here we propose that a potential outcome of this atmospheric evolution is the formation of helium-dominated atmospheres. The hydrodynamic escape rates of Neptune- and sub-Neptune-sized exoplanets are comparable to the diffusion-limited escape rate of hydrogen, and therefore the escape is heavily affected by diffusive separation between hydrogen and helium. A helium atmosphere can thus be formed—from a primordial hydrogen–helium atmosphere—via atmospheric hydrodynamic escape from the planet. The helium atmosphere has very different abundances of major carbon and oxygen species from those of a hydrogen atmosphere, leading to distinctive transmission and thermal emission spectral features. In particular, the hypothesis of a helium-dominated atmosphere can explain the thermal emission spectrum of GJ 436b, a warm Neptune-sized exoplanet, while also being consistent with the transmission spectrum. This model atmosphere contains trace amounts of hydrogen, carbon, and oxygen, with the predominance of CO over CH{sub 4} as the main form of carbon. With our atmospheric evolution model, we find that if the mass of the initial atmosphere envelope is 10{sup −3} planetary mass, hydrodynamic escape can reduce the hydrogen abundance in the atmosphere by several orders of magnitude in ∼10 billion years. Observations of exoplanet transits may thus detect signatures of helium atmospheres and probe the evolutionary history of small exoplanets.

79 ASTRONOMY AND ASTROPHYSICS↗

Synchrotron-based X-ray fluorescence microscopy mapping the ionome of a toxic freshwater cyanobacterium

Harmful algal blooms (HABs) pose a major environmental concern across the globe. In abundance, cyanobacteria, or so-called green-blue algae can produce extremely dangerous cyanotoxins that harm humans and animals. This study focused on the mapping and distribution of intracellular macro-and micronutrients of the widespread freshwater cyanobacteria Microcystis aeruginosa (M. aeruginosa). Towards a better understanding of trace metal uptake and homeostasis throughout the cell cycle, we quantitatively mapped the spatial distribution of the elements P, K, Fe, Ca, Zn, Mn, and Cu across the ultrastructure of frozen-hydrated single cells using state-of-theart X-ray nanofluorescence imaging at the Advanced Photon Source (APS) at Argonne National Laboratory. Further, bulk cellular nutrient and trace metal content correlated well with the total intracellular elemental content in individual cells obtained by quantitative synchrotron X-ray fluorescence measurements. Multi-dimensional mappings showed P and K atoms colocalized as discrete semicircular hotspots that were analyzed with respect to their stoichiometry. Elevated Cu and Ca concentrations were detected along division plane of cells. P and K were found to have similar spatial elemental distribution with about 65% and 69% of the total cellular P and K, respectively, located at the hotspots. The P and K colocalization were refined further using nanotomography, showing a K envelope surrounding the P core. Inorganic P and organic P compounds were specified using solution-state 31 P nuclear magnetic resonance (NMR) spectroscopy from M. aeruginosa. Of the total extracted P determined by 31 P NMR spectroscopy, 47% were found to be nucleotides while only 11% were polyphosphates. Multimodal X-ray imaging provides a better understanding of intracellular biochemical processes in cyanobacteria, helping us monitor and combat an emerging environmental threat.

31P NMR spectroscopy↗

X-ray Fluorescence Nanotomography of Single Bacteria with a Sub-15 nm Beam

Abstract X-ray Fluorescence (XRF) microscopy is a growing approach for imaging the trace element concentration, distribution, and speciation in biological cells at the nanoscale. Moreover, three-dimensional nanotomography provides the added advantage of imaging subcellular structure and chemical identity in three dimensions without the need for staining or sectioning of cells. To date, technical challenges in X-ray optics, sample preparation, and detection sensitivity have limited the use of XRF nanotomography in this area. Here, XRF nanotomography was used to image the elemental distribution in individual E . coli bacterial cells using a sub-15 nm beam at the Hard X-ray Nanoprobe beamline (HXN, 3-ID) at NSLS-II. These measurements were simultaneously combined with ptychography to image structural components of the cells. The cells were embedded in small (3–20 µm) sodium chloride crystals, which provided a non-aqueous matrix to retain the three-dimensional structure of the E . coli while collecting data at room temperature. Results showed a generally uniform distribution of calcium in the cells, but an inhomogeneous zinc distribution, most notably with concentrated regions of zinc at the polar ends of the cells. This work demonstrates that simultaneous two-dimensional ptychography and XRF nanotomography can be performed with a sub-15 nm beam size on unfrozen biological cells to co-localize elemental distribution and nanostructure simultaneously.

59 BASIC BIOLOGICAL SCIENCES↗

Elemental analysis of air-sensitive frozen molten salt samples using an inert transfer chamber for LIBS/LA-ICP-TOF-MS analysis

A novel inert sample transfer system was developed and employed to enable, for the first time, the analysis of air-sensitive salt samples in a two-volume ablation cell using simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation (LA)-inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) analysis. Molten salts are of growing interest as a medium for advanced nuclear reactors and nuclear fuel reprocessing technologies continue to be developed around their use. However, compositional analysis of molten salt samples can be challenging because of their air-sensitive nature and varying solubilities leading to inaccurate measurements when digested. LA-based analysis provides an alternate method to digestion and can provide rapid elemental information with little sample preparation. In this study, LIBS and LA-ICP-TOF-MS were used to analyze the Ce content in frozen salt samples taken from a series of electrochemical experiments. Calibrations were built for each technique, and the resulting limits of detection for Ce were estimated to be 107 and 58 µg g −1 for LIBS and LA-ICP-TOF-MS, respectively. Test samples from the electrochemical experiments were analyzed using these calibrations. The results matched bulk digestion-based ICP-optical emission spectroscopy values, and daily trends in Ce concentration changes were identified. Additionally, the LIBS and LA-ICP-TOF-MS analysis was demonstrated for identifying microgram per gram levels of components and detecting trace contaminants. The impurities detected by LIBS included Al, Mg, Ca, and Na. The impurities detected by LA-ICP-TOF-MS included W, Ag, Al, Fe, Ni, Mo, Nd, Sm, Th, and U.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Analysis of liquid petroleum using a laser-induced breakdown spectroscopy instrument

Here, a prototype analyzer for the direct LIBS analysis of nebulized liquid samples was developed and tested, particularly for the analysis of petroleum, organic solvents and aqueous solutions. The LIBS analyzer requires about 750 µl of liquid sample, 1 liter of N 2 gas, and 10 s of the analysis time to record 100 spectra. The limits of detection in oil and solvent are as low as 0.01–0.04 ppm for Li, Mg, and Cu. They increase for the difficult elements, such as Pb and Hg (7-10 ppm), Cl (250 ppm), and S (~0.7%). The relative standard deviation of measuring 100 ppm vanadium in oil and solvent was 1.5%. The LIBS detection limits and repeatability are better than required by the standard method ASTM D5185 for the analysis of lubricating oils in ICP-OES. Several petroleum samples were analyzed by LIBS and the quantitative results for V, Ni, and Fe compared to the ICP-OES data. Light crude oils can be nebulized and analyzed directly. Medium crude oils require minimal dilution at least 1:1, otherwise errors of determination become large. Presumably, utilization of the internal standard and chemometrics can be useful to correct for the matrix effects. In addition to the trace element analysis, the LIBS prototype demonstrated ability to measure the hydrogen-to-carbon ratio in organic liquid samples. Several unidentified features were observed in the carbon spectrum. Their possible origin is discussed.

02 PETROLEUM↗

DETECTIONS OF C{sub 2}H, CYCLIC-C{sub 3}H{sub 2}, AND H{sup 13}CN IN NGC 1068

We used the Nobeyama 45 m telescope to conduct a spectral line survey in the 3 mm band (85.1-98.4 GHz) toward one of the nearest galaxies with an active galactic nucleus (AGN), NGC 1068, and the prototypical starburst galaxy NGC 253. The beam size of this telescope is {approx} 18'', which was sufficient to spatially separate the nuclear molecular emission from the emission of the circumnuclear starburst region in NGC 1068. We detected rotational transitions of C{sub 2}H, cyclic-C{sub 3}H{sub 2}, and H{sup 13}CN in NGC 1068. These are detections of carbon-chain and carbon-ring molecules in NGC 1068. In addition, the C{sub 2}H N = 1-0 lines were detected in NGC 253. The column densities of C{sub 2}H were determined to be 3.4 x 10{sup 15} cm{sup -2} in NGC 1068 and 1.8 x 10{sup 15} cm{sup -2} in NGC 253. The column densities of cyclic-C{sub 3}H{sub 2} were determined to be 1.7 x 10{sup 13} cm{sup -2} in NGC 1068 and 4.4 x 10{sup 13} cm{sup -2} in NGC 253. We calculated the abundances of these molecules relative to CS for both NGC 1068 and NGC 253, and found that there were no significant differences in the abundances between the two galaxies. This result suggests that the basic carbon-containing molecules are either insusceptible to AGN or are tracing cold (T{sub rot} {approx} 10 K) molecular gas rather than X-ray irradiated hot gas.

79 ASTRONOMY AND ASTROPHYSICS↗

Higher-Order Optical Modes and Nanostructures for Detection and Imaging Applications

Raman spectroscopy offers a label-free, chemically specific, method of detecting molecules; however, the low cross-section attendant to this scattering process has hampered trace detection. The realization that scattering is enhanced at a metallic surface has enabled new techniques for spectroscopic and imaging analysis.

77 NANOSCIENCE AND NANOTECHNOLOGY↗