Validation of Radiometric Standards for the Laboratory Calibration of Reflected-Solar Earth Observing Satellite Instruments

Historically, the traceability of the laboratory calibration of Earth-observing satellite instruments to a primary radiometric reference scale (SI units) is the responsibility of each instrument builder. For the NASA Earth Observing System (EOS), a program has been developed using laboratory transfer radiometers, each with its own traceability to the primary radiance scale of a national metrology laboratory, to independently validate the radiances assigned to the laboratory sources of the instrument builders. The EOS Project Science Office also developed a validation program for the measurement of onboard diffuse reflecting plaques, which are also used as radiometric standards for Earth-observing satellite instruments. Summarized results of these validation campaigns, with an emphasis on the current state-of-the-art uncertainties in laboratory radiometric standards, will be presented. Future mission uncertainty requirements, and possible enhancements to the EOS validation program to ensure that those uncertainties can be met, will be presented.

Butler, James J.↗

Measurement of Plutonium Ratios for CRM 137A Recertification

This report documents the analytical methodologies used by the Chemical and Isotopics Mass Spectrometry (CIMS) Group at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) for plutonium isotopic ratio characterizations on purified ~1 mg units prepared by Lawrence Livermore National Laboratory (LLNL) from a mother solution created from an existing 250 mg unit of certified reference material (CRM) 137. The analytical processes described are designed to maintain traceability of the final certified attributes and to eliminate sources of systematic bias for the measurements described. The measurands for certification are the plutonium isotope ratios: 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu. The preparation and analytical process included the following activities: Preparation of reference materials to be used as calibrants to establish traceability to the SI unit of mass for the isotopic analyses and quality controls. For the plutonium isotopic analyses, CRM 128 (a CRM comprising equal atoms of 239 Pu and 242 Pu) was used as the primary calibrant; Each CRM 137A unit was reconstituted using dilute high-purity HNO3. From each, seven replicates were distributed for the isotopic characterizations by thermal ionization mass spectrometry (TIMS) using the total evaporation (TE) method for isotope ratio measurements and MC-ICP-MS using a dynamic peak hooping method for secondary isotope ratio measurements; Due to time delay in the analyses from the last purification of the original CRM 137 mother solution by LLNL, an aliquot of the three provided plutonium units was purified using Eichrom TEVA separation methods to remove americium in-growth and uranium impurities; Minimally corrected data were reported from each analysis using reporting templates provided by the New Brunswick Laboratory Program Office (NBL PO) for the specific methods used for isotopic measurements. In addition, a copy of the instrument exports, Excel templates for isotopic data corrections, and the uncertainty budgets completed with the GUM Workbench software package were submitted to NBL PO.

07 ISOTOPE AND RADIATION SOURCES↗

ARCSTONE: Calibration of Lunar Spectral Reflectance from Space

Detecting and improving the scientific understanding of global trends in complex Earth systems, such as climate, increasingly depends on assimilating datasets from multiple instruments and platforms over decadal timescales. Calibration accuracy, stability, and inter-consistency among different instruments are key to developing reliable composite data records from sensors in low Earth and geostationary orbits, but achieving sufficiently low uncertainties for these performance metrics poses a significant challenge. Space-borne instruments commonly carry on-board references for calibration at various wavelengths, but these increase mass and mission complexity, and are subject to degradation in the space environment. The Moon can be considered a natural solar diffuser which can be observed as a calibration target by most spaceborne Earth-observing instruments. Since the lunar surface reflectance is effectively time-invariant, establishing the Moon as a high-accuracy calibration reference enables broad inter-calibration opportunities even between temporally non-overlapping instruments and provides an exo-atmospheric absolute radiometric standard. The ARCSTONE mission goal is to establish the Moon as a reliable reference for high-accuracy on-orbit calibration in the visible and near-infrared spectral region. The ARCSTONE instrument is a compact spectrometer, which will be packaged on a CubeSat intended for low Earth orbit. It will measure the lunar spectral reflectance with accuracy < 0.5% (k=1), sufficient to establish an SI-traceable absolute lunar calibration standard when referenced to the spectral solar irradiance across the 350 to 2300 nm spectral range. This lunar reference will help to enable high-accuracy absolute calibration and inter-calibration of past, current, and future Earth-observing sensors, meteorological imagers, and long-term climate monitoring satellite systems. The ARCSTONE team will present the development status of a full-spectral-range (FSR) instrument, the intended approach to calibration and characterization, and the planned path toward mission implementation.

calibration↗

ARCSTONE: Calibration of Lunar Spectral Reflectance from Space

Detecting and improving the scientific understanding of global trends in complex Earth systems, such as climate, increasingly depends on assimilating datasets from multiple instruments and platforms over decadal timescales. Calibration accuracy, stability, and inter-consistency among different instruments are key to developing reliable composite data records from sensors in low Earth and geostationary orbits, but achieving sufficiently low uncertainties for these performance metrics poses a significant challenge. Space-borne instruments commonly carry on-board references for calibration at various wavelengths, but these increase mass and mission complexity, and are subject to degradation in the space environment. The Moon can be considered a natural solar diffuser which can be observed as a calibration target by most spaceborne Earth-observing instruments. Since the lunar surface reflectance is effectively time-invariant, establishing the Moon as a high-accuracy calibration reference enables broad inter-calibration opportunities even between temporally non-overlapping instruments and provides an exo-atmospheric absolute radiometric standard. The ARCSTONE mission goal is to establish the Moon as a reliable reference for high-accuracy on-orbit calibration in the visible and near-infrared spectral region. The ARCSTONE instrument is a compact spectrometer, which will be packaged on a CubeSat intended for low Earth orbit. It will measure the lunar spectral reflectance with accuracy < 0.5% (k=1), sufficient to establish an SI-traceable absolute lunar calibration standard when referenced to the spectral solar irradiance across the 350 to 2300 nm spectral range. This lunar reference will help to enable high-accuracy absolute calibration and inter-calibration of past, current, and future Earth-observing sensors, meteorological imagers, and long-term climate monitoring satellite systems. The ARCSTONE team will present the development status of a full-spectral-range (FSR) instrument, the intended approach to calibration and characterization, and the planned path toward mission implementation.

Moon↗

EUNIS Underflight Calibrations of CDS, EIT, TRACE, EIS, and EUVI

The Extreme-Ultraviolet Normal-Incidence Spectrograph (EUNIS) is a sounding rocket instrument that obtains imaged high-resolution solar spectra. It has now had two successful flights, on 2006 April 12 and 2007 November 16, providing data to support underflight calibrations for a number of orbiting solar experiments on both occasions. A regular part of each campaign is the end-to-end radiometric calibration of the rocket payload carried out at RAL in the UK, using the same facility that provided pre-flight CDS and EIS calibrations. The measurements, traceable to primary radiometric standards, can establish the absolute EUNIS response within a total uncertainty of 10% over its full longwave bandpass of 300-370A. During each EUNIS flight, coordinated observations are made of overlapping solar locations by all participating space experiments, and identified by subsequent image co-registrations, allowing the EUNIS calibrations to be applied to these other instruments as well. The calibration transfer is straightforward for wavelengths within the EUNIS LW bandpass, and is extended to other wavelengths by means of a series of temperature- and density-insensitive line-ratios, with one line of each pair in the calibrated band and the other in the transfer band. In this way, the EUNIS-06 flight is able to update the radiometric calibrations of CDS NISl (and 2nd-order NIS2 near 2x304A), all four channels of EIT, and the three EUV channels of TRACE. The EUNIS-07 flight will further update those missions, as well as both channels of Hinode/EIS and all four channels of STEREO/SECCHI/EUVI. Future EUNIS flights have been proposed that will continue this underflight calibration service. EUNIS is supported by the NASA Heliophysics Division through its Low Cost Access to Space Program in Solar and Heliospheric Physics.

Thomas, Roger J.↗

EUNIS Underflight Calibrations of CDS, EIT, TRACE, EIS, and EUVI

The Extreme-Ultraviolet Normal-Incidence Spectrograph (EUNIS) is a sounding rocket instrument that obtains imaged high-resolution solar spectra. It has now had two successful flights, on 2006 April 12 and 2007 November 16, providing data to support underflight calibrations for a number of orbiting solar experiments on both occasions. A regular part of each campaign is the end-to-end radiometric calibration of the rocket payload carried out at RAL in the UK, using the same facility that provided pre-flight CDS and EIS calibrations. The measurements, traceable to primary radiometric standards, can establish the absolute EUNIS response within a relative uncertainty of 10% over its full longwave bandpass of 300-370A. During each EUNIS flight, coordinated observations are made of overlapping solar locations by all participating space experiments, and identified by subsequent image co-registrations, allowing the EUNIS calibrations to be applied to these other instruments as well. The calibration transfer is straightforward for wavelengths within the EUNIS LW bandpass, and is extended to other wavelengths by means of a series of 'insensitive' line-ratios, with one line of each pair in the calibrated band and the other in the transfer band. In this way, the EUNIS-06 flight is able to update the radiometric calibrations of CDS NISl (plus 2nd order NIS2 near 2x304A), all four channels of EIT, and the three EUV channels of TRACE. The EUNIS-07 flight will further update those missions, as well as both channels of Hinode/EIT and all four channels of STEREO/SECCHI/EUVI. Future EUNIS flights have been proposed that will continue this underflight calibration service. EUNIS is supported by the NASA Heliophysics Division through its Low Cost Access to Space Program in Solar and Heliospheric Physics.

Thomas, Roger J.↗

Guidelines by the AAPM and GEC-ESTRO on the use of innovative brachytherapy devices and applications: Report of Task Group 167

Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used in the evaluation of innovative devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining the equivalence of the innovative treatment modality to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of innovative radiotherapy devices or applications is a critical part in which physicists should be actively involved. The physicist’s role, along with physician colleagues, in this process is highlighted for innovative brachytherapy devices and applications and includes evaluation of (1) dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, (2) risks and benefits from a regulatory and safety perspective, and (3) resource assessment and preparedness. Further, it is suggested that any developed calibration methods be traceable to a primary standards dosimetry laboratory (PSDL) such as the National Institute of Standards and Technology in the U.S. or to other PSDLs located elsewhere such as in Europe. Clinical users should follow standards as approved by their country’s regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the Accredited Dosimetry Calibration Laboratories in the U.S. is encouraged before a source is introduced into widespread routine clinical use. The American Association of Physicists in Medicine and the Groupe Européen de Curiethérapie-European Society for Radiotherapy and Oncology (GEC-ESTRO) have developed guidelines for the safe and consistent application of brachytherapy using innovative devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of requirements of the U.S. Nuclear Regulatory Commission, U.S. Department of Transportation, International Electrotechnical Commission Medical Electrical Equipment Standard 60601, U.S. Food and Drug Administration, European Commission for CE Marking (Conformité Européenne), and institutional review boards and radiation safety committees.

60 APPLIED LIFE SCIENCES↗

NREL Pyrheliometer Comparisons: September 23-October 4, 2019 (NPC-2019)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for developing and deploying solar energy conversion systems, improving our understanding of the Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations that are traceable to an international standard is the first step in producing research-quality solar irradiance measurements. In 1977, the World Meteorological Organization (WMO) established the World Radiometric Reference (WRR) as the international standard for the measurement of direct normal solar irradiance (Frohlich 1991). The WRR is an internationally recognized, detector-based measurement standard determined by the collective performance of six electrically self-calibrated absolute cavity radiometers comprising the World Standard Group (WSG). Various countries, including the United States, have contributed these specialized radiometers to the Physikalisch-Meteorologisches Observatorium Davos - World Radiation Center (PMOD/WRC) to establish the WSG.

14 SOLAR ENERGY↗

Accurate spring constant calibration for very stiff atomic force microscopy cantilevers

There are many atomic force microscopy (AFM) applications that rely on quantifying the force between the AFM cantilever tip and the sample. The AFM does not explicitly measure force, however, so in such cases knowledge of the cantilever stiffness is required. In most cases, the forces of interest are very small, thus compliant cantilevers are used. A number of methods have been developed that are well suited to measuring low stiffness values. However, in some cases a cantilever with much greater stiffness is required. Thus, a direct, traceable method for calibrating very stiff (approximately 200 N/m) cantilevers is presented here. The method uses an instrumented and calibrated nanoindenter to determine the stiffness of a reference cantilever. This reference cantilever is then used to measure the stiffness of a number of AFM test cantilevers. This method is shown to have much smaller uncertainty than previously proposed methods. An example application to fracture testing of nanoscale silicon beam specimens is included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Spectral Radiance Calibration Techniques Used for Backscatter Ultraviolet Satellite Instruments

Methods for determining the absolute radiometric calibration sensitivities of backscatter ultraviolet (BUV) satellite instruments are compared as part of an effort to minimize pre-launch calibration errors. An internally illuminated integrating sphere source has been used for the Shuttle Solar BUV (SSBUV), Total Ozone Mapping Spectrometer (TOMS), Ozone Mapping Instrument (OMI), and Global Ozone Monitoring Experiment 2 (GOME-2) using standardized procedures traceable to national standards. These sphere-based sensitivities agree to within three percent [k equals 2] relative to calibrations performed using an external diffuser illuminated by standard irradiance sources, the customary radiance calibration method for BUV instruments. The uncertainty for these calibration techniques as implemented at the NASA Goddard Space Flight Centers Radiometric Calibration and Development Laboratory is shown to be 4 percent at 250nm [k equals 2] when using a single traceable calibration standard. Significant reduction in the uncertainty of nearly 1 percent is demonstrated when multiple calibration standards are used.

residual errors↗

Results of Second Outdoor Comparison Between Absolute Cavity Pyrgeometer (ACP) and Infrared Integrating Sphere (IRIS) Radiometer at PMOD (Presentation)

The Absolute Cavity Pyrgeometer (ACP) and InfraRed Integrating Sphere radiometer (IRIS) are developed to establish a world reference for calibrating pyrgeometers with traceability to SI units. The two radiometers are un-windowed with negligible spectral dependence, and traceable to SI units through the temperature scale (ITS-90). The second outdoor comparison between the two designs was held from September 30 to October 11, 2013 at the Physikalisch-Metorologisches Observatorium Davos (PMOD). The difference between the irradiance measured by ACP and that of the IRIS was within 1 W/m2 (3 IRISs: PMOD + Australia + Germany). From the first and second comparisons, a difference of 4-6 W/m2 was observed between the irradiance measured by ACP&IRIS and that of the interim World Infrared Standard Group (WISG). This presentation includes results from the first and second comparison in an effort to establish the world reference for pyrgeometer calibrations, a key deliverable for the World Meteorological Organization (WMO), and the DOE-ASR.

47 OTHER INSTRUMENTATION↗

Results of First Outdoor Comparison Between Absolute Cavity Pyrgeometer (ACP) and Infrared Integrating Sphere (IRIS) Radiometer at PMOD (Presentation)

The ACP and IRIS are developed to establish a world reference for calibrating pyrgeometers with traceability to SI units. The two radiometers are unwindowed with negligible spectral dependence, and traceable to SI units through the temperature scale (ITS-90). The first outdoor comparison between the two designs was held from January 28 to February 8, 2013 at the Physikalisch-Metorologisches Observatorium Davos (PMOD). The difference between the irradiance measured by ACP and that of IRIS was within 1 W/m2. A difference of 5 W/m2 was observed between the irradiance measured by ACP&IRIS and that of the interim World Infrared Standard Group (WISG).

14 SOLAR ENERGY↗

SU-E-T-408: Determination of KQ,Q0-Factors From Water and Graphite Calorimetry in a 60 MeV Proton Beam

Purpose: To reduce the uncertainty of the beam quality correction factor k Q,Q0 , for scattered proton beams (SPB). This factor is used in dosimetry protocols, to determine absorbed dose-to-water with ionization chambers. For the Roos plane parallel chambers (RPPICs), the IAEA TRS-398 protocol estimates k Q,Q0 -factor to be 1.004(for a beam quality Rres=2 g.cm{sup 2}), with an uncertainty of 2.1%. Methods: A graphite calorimeter (GCal), a water calorimeter (WCal) and RPPICs were exposed, in a single experiment, to a 60 MeV non-modulated SPB. RPPICs were calibrated in terms of absorbed dose-to-water in a 20 MeV electron beam. The calibration coefficient is traceable to NPL's absorbed dose standards. Chamber measurements were corrected for environmental conditions, recombination and polarity. The WCal corrections include heat loss, heat defect and vessel perturbation. The GCal corrections include heat loss and absorbed dose conversion. Except for heat loss correction and its uncertainty in the WCal system, all major corrections were included in the analysis. Other minor corrections, such as beam profile non-uniformity, are still to be evaluated. Experimental k Q,Q0 -factors were derived by comparing the results obtained with both calorimeters and ionometry. Results: The absorbed dose-to-water from both calorimeters was found to be within 1.3% with an uncertainty of 1.2%. k Q,Q0 -factor for a RPPIC was found to be 0.998 and 1.011, with a standard uncertainty of 1.4% and 0.9% when the dose is based on the GCal and the WCal, respectively. Conclusion: Results suggest the possibility to determine k Q,Q0 -values for PPICs in SPB with a lower uncertainty than specified in the TRS-398 thereby helping to reduce uncertainty on absorbed dose-to-water. The agreement between calorimeters confirms the possibility to use GCal or WCal as primary standard in SPB. Because of the dose conversion, the use of GCal may lead to slightly higher uncertainty, but is, at present, considerably easier to operate.

07 ISOTOPE AND RADIATION SOURCES↗

SU-C-BRD-07: The Radiological Physics Center (RPC): 45 Years of Improving Radiotherapy Dosimetry

Purpose: The RPC, established in 1968 has contributed to the development, conduct, and QA of NCI funded multi-institutional cooperative group clinical trials and institutions, primarily in the USA/Canada and 242 other countries, participating in trials. Methods: The RPC QA program components were designed to audit the radiation dose calculation chain from the NIST traceable reference beam calibration, to inclusion of dosimetry parameters used to calculate tumor doses, to the delivery of the radiation dose. The QA program included: 1) remote TLD/OSLD audit of machine output, 2) on-site dosimetry review visits, 3) credentialing for advanced technologies, and 4) review of patient treatment records. The RPC presented and published their findings to the radiation oncology community. Results: The number of institutions monitored by the RPC increased from around 1200 in the late 90s, to ∼2000 in 2013. There were over 4000 megavoltage therapy machines and ∼28,000 therapy beams in the 1991 institutions monitored by the RPC by the end of 2013. Within the 14,000 photon, electron and proton beam outputs remotely monitored with TLD/OSLD annually, between 10-20% of the institutions have one or more beams outside the RPC 5% criterion. Dosimetry site visits to photon and proton centers continue to result in 2-4 recommendations affecting key dosimetry parameters that impact patient treatment times. One in four patient treatment records reviewed by the RPC have their dose data corrected by >5% before trial groups use them for outcomes analysis. Twelve of fourteen clinically active proton centers are approved to participate in NCI funded clinical trials. The RPC published 222 peer reviewed articles since 1972. Conclusion: Findings from the RPC suggest that human errors continue to play a role in radiotherapy discrepancies and without the RPC independent QA program, the number of undetected errors and time elapsed before their discovery would have been greater. Work supported by MGH C06 CA059267 and grants CA10953, CA081647 awarded by NCI, DHHS.

60 APPLIED LIFE SCIENCES↗

TU-G-BRD-06: The Imaging and Radiation Oncology Core Houston (IROC Houston) QA Center International Activities Outside North America

Purpose: To describe the extent of IROC Houston’s (formerly the RPC) QA activities and audit results for radiotherapy institutions outside of North America (NA). Methods: The IROC Houston’s QA program components were designed to audit the radiation dose calculation chain from the NIST traceable reference beam calibration, to inclusion of dosimetry parameters used to calculate tumor doses, to the delivery of the radiation dose. The QA program provided to international institutions includes: 1) remote TLD/OSLD audit of machine output, 2) credentialing for advanced technologies, and 3) review of patient treatment records. IROC Houston uses the same standards and acceptance criteria for all of its audits whether for North American or international sites. Results: IROC Houston’s QA program has reached out to radiotherapy sites in 43 different countries since 2013 through their participation in clinical trials. In the past two years, 2,778 international megavoltage beam outputs were audited with OSLD/TLD. While the average IROC/Inst ratio is near unity for all sites monitored, there are international regions whose results are significantly different from the NA region. In the past 2 years, 477 and 87 IMRT H&N phantoms were irradiated at NA and international sites, respectively. Regardless of the OSLD beam audit results, the overall pass rate (87 percent) for all international sites (no region separation) is equal to the NA sites. Of the 182 international patient charts reviewed, 10.7 percent of the dose calculation points did not meet our acceptance criterion as compared to 13.6 percent for NA sites. The lower pass rate for NA sites results from a much larger brachytherapy component which has been shown to be more error prone. Conclusion: IROC Houston has expanded its QA services worldwide and continues a long history of improving radiotherapy dose delivery in many countries. Funding received for QA audit services from the Korean GOG, DAHANCA, EORTC, ICON and CMIC Group.

60 APPLIED LIFE SCIENCES↗

A Procedure to Correct the Historical Atmospheric Longwave Irradiance Data When the World Reference Is Established with Respect to the International System of Units

Historical atmospheric longwave irradiance data sets with traceability to the International System of Units (SI) are essential for renewable energy and atmospheric science research and applications. To date, all pyrgeometers used to measure the irradiance are traceable to the interim World Infrared Standard Group (WISG), not to SI units. In 2013, the Absolute Cavity Pyrgeometer (ACP) (Reda et al. 2012) was developed at the National Renewable Energy Laboratory (NREL) to measure the atmospheric longwave irradiance. The ACP has been compared against the InfraRed Integrating Sphere (IRIS), developed by the Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC) (Grobner 2012). The ACP and the IRIS are absolute instruments traceable to SI units through the International Temperature Scale of 1990. Results of six comparisons between the ACP and the IRIS at different locations have shown that the irradiance measured by WISG pyrgeometers underestimates clear-sky atmospheric longwave irradiance by 2 W/m 2 to 6 W/m 2 (Grobner et al. 2014); therefore, once the world reference is established with traceability to SI units, the WISG would be corrected, then used to calibrate field pyrgeometers with traceability to SI units. The following described method is used to correct the historical atmospheric longwave irradiance data sets in anticipation of the WISG scale change.

47 OTHER INSTRUMENTATION↗

NREL Pyrheliometer Comparisons: September 26-October 7, 2016 (NPC-2016)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for developing and deploying solar energy conversion systems, improving our understanding of the Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations that are traceable to an international standard is the first step in producing research-quality solar irradiance measurements. National Renewable Energy Laboratory (NREL) pyrheliometer comparisons (NPCs) are held annually at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado. Open to all pyrheliometer owners and operators, each NPC provides an opportunity to determine the unique World Radiometric Reference transfer factor (WRR-TF) for each participating pyrheliometer. By adjusting all subsequent pyrheliometer measurements by the appropriate WRR-TF, the solar irradiance data are traceable to the WRR. NPC-2016 was September 26 through October 7, 2016. Participants operated 45 absolute cavity radiometers and 27 conventional thermopile-based pyrheliometers to simultaneously measure clear-sky, direct normal solar irradiance during this period.

14 SOLAR ENERGY↗

A Procedure to Correct the Historical Atmospheric Longwave Irradiance Data When the World Reference Is Established with Respect to the International System of Units

Historical and traceable atmospheric longwave irradiance data sets with traceability to the International System of units (SI) are essential for renewable energy and atmospheric science research and applications. To date, all pyrgeometers used to measure the irradiance are traceable to the interim World InfraRed Standard Group (WISG) not to SI units. In 2013 the Absolute Cavity Pyrgeometer (ACP), [Reda et al., 2012] was developed at the National Renewable Energy Laboratory (NREL) to measure the atmospheric longwave irradiance. The ACP has been compared against the InfraRed Integrating Sphere (IRIS) developed by the Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC) [J. Grobner, 2012]. ACP and IRIS are absolute instruments traceable to SI units through the International Temperature Scale ITS-90. Results of six comparisons between ACP and IRIS at different location have shown that the irradiance measured by WISG pyrgeometers is underestimating clear-sky atmospheric longwave irradiance by 2 to 6 W/m 2 [Grobner et al., 2014]. Therefore, once the world reference is established with traceability to SI units the WISG would be corrected then used to calibrate field pyrgeometers with traceability to SI units. The described method below is used to correct the historical atmospheric longwave irradiance data sets in anticipation of the WISG scale change.

54 ENVIRONMENTAL SCIENCES↗