Search NASA⌕ Search

SEARCH · Search NASA

Results for “transfer line”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Numerical Modeling of No Vent Filling of a Cryogenic Tank

This paper presents a multi-node finite volume model of the chilling and filling of a cryogenic tank using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. Vented Chill and No Vent Fill (VCNVF) tests were conducted at Marshall Space Flight Center where a flight-like tank was filled with liquid nitrogen from a supply tank. In the VCNVF tests, the tank was partially chilled while the vent valve was open. After the partial chilling, the vent valve was closed and the tank was filled without any venting. An integrated numerical model of the test set up was developed. The model included the transfer line from the supply tank, the target tank with the spray nozzle and solid walls, and the discharge line with the vent valve. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor in the tank when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall and ullage temperature in the tank were compared with the test data.

Alok Majumdar↗

Numerical Modeling of No Vent Filling of a Cryogenic Tank

This paper presents a multi-node finite volume model of the chilling and filling of a cryogenic tank using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. Vented Chill and No Vent Fill (VCNVF) tests were conducted at Marshall Space Flight Center where a flight-like tank was filled with liquid nitrogen from a supply tank. In the VCNVF tests, the tank was partially chilled while the vent valve was open. After the partial chilling, the vent valve was closed and the tank was filled without any venting. An integrated numerical model of the test set up was developed. The model included the transfer line from the supply tank, the target tank with the spray nozzle and solid walls, and the discharge line with the vent valve. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor in the tank when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall and ullage temperature in the tank were compared with the test data.

Alok Majumdar↗

Cryogenic Propellant Feed System Analytical Tool Development

The Propulsion Systems Branch at NASA s Lyndon B. Johnson Space Center (JSC) has developed a parametric analytical tool to address the need to rapidly predict heat leak into propellant distribution lines based on insulation type, installation technique, line supports, penetrations, and instrumentation. The Propellant Feed System Analytical Tool (PFSAT) will also determine the optimum orifice diameter for an optional thermodynamic vent system (TVS) to counteract heat leak into the feed line and ensure temperature constraints at the end of the feed line are met. PFSAT was developed primarily using Fortran 90 code because of its number crunching power and the capability to directly access real fluid property subroutines in the Reference Fluid Thermodynamic and Transport Properties (REFPROP) Database developed by NIST. A Microsoft Excel front end user interface was implemented to provide convenient portability of PFSAT among a wide variety of potential users and its ability to utilize a user-friendly graphical user interface (GUI) developed in Visual Basic for Applications (VBA). The focus of PFSAT is on-orbit reaction control systems and orbital maneuvering systems, but it may be used to predict heat leak into ground-based transfer lines as well. PFSAT is expected to be used for rapid initial design of cryogenic propellant distribution lines and thermodynamic vent systems. Once validated, PFSAT will support concept trades for a variety of cryogenic fluid transfer systems on spacecraft, including planetary landers, transfer vehicles, and propellant depots, as well as surface-based transfer systems. The details of the development of PFSAT, its user interface, and the program structure will be presented.

Lusby, Brian S.↗

Fluctuations at the blue edge of saturated wind lines in IUE spectra of O-type stars

We examine basic issues involved in synthesizing resonance-line profiles from 1-D, dynamical models of highly structured hot-star winds. Although these models exhibit extensive variations in density as well as velocity, the density scale length is still typically much greater than the Sobolev length. The line transfer is thus treated using a Sobolev approach, as generalized by Rybicki & Hummer (1978) to take proper account of the multiple Sobolev resonances arising from the nonmonotonic velocity field. The resulting reduced-Lambda-matrix equation describing nonlocal coupling of the source function is solved by iteration, and line profiles and then derived from formal solution integration using this source function. The more appropriate methods that instead use either a stationary or a structured, local source function yield qualitatively similar line-profiles, but are found to violate photon conservation by 10 percent or more. The full results suggest that such models may indeed be able to reproduce naturally some of the qualitative properties long noted in observed UV line profiles, such as discrete absorption components in unsaturated lines, or the blue-edge variability in saturated lines. However, these particular models do not yet produce the black absorption troughs commonly observed in saturated lines, and it seems that this and other important discrepancies (e.g., in acceleration time scale of absorption components) may require development of more complete models that include rotation and other 2-D and/or 3-D effects.

Owocki, Stanley P.↗

On the synthesis of resonance lines in dynamical models of structured hot-star winds

We examine basic issues involved in synthesizing resonance-line profiles from 1-D, dynamical models of highly structured hot-star winds. Although these models exhibit extensive variations in density as well as velocity, the density scale length is still typically much greater than the Sobolev length. The line transfer is thus treated using a Sobolev approach, as generalized by Rybicki & Hummer (1978) to take proper account of the multiple Sobolev resonances arising from the nonmonotonic velocity field. The resulting reduced-lambda-matrix equation describing nonlocal coupling of the source function is solved by iteration, and line profiles are then derived from formal solution integration using this source function. Two more approximate methods that instead use either a stationary or a structured, local source function yield qualitatively similar line-profiles, but are found to violate photon conservation by 10% or more. The full results suggest that such models may indeed be able to reproduce naturally some of the qualitative properties long noted in observed UV line profiles, such as discrete absorption components in unsaturated lines, or the blue-edge variability in saturated lines. However, these particular models do not yet produce the black absorption troughs commonly observed in saturated lines, and it seems that this and other important discrepancies (e.g., in acceleration time scale of absorption components) may require development of more complete models that include rotation and other 2-D and/or 3-D effects.

Puls, J.↗

Experimental verification of a tank to tank He II transfer model with trade study results

A computer program has been developed to study the thermodynamics of tank to tank superfluid helium transfer. The model includes a supply and a receiver tank connected by a transfer line. The convey of He II from one tank to the other is controlled by a fountain effect pump (FEP). Phase separators are present in both the supply and receiver tank to regulate the bath temperature. Description of this model has been published elsewhere. In the present paper, data from a transfer experiment are used to verify the accuracy of this model. The experiment consisted of an FEP made of a 2-micron sintered stainless steel porous plug. Superfluid has been transferred from a liquid helium bath into a glass beaker. Bath temperatures, flowrate and heater power records are available. These results are compared to the predictions of the computer program and good agreement is found between the two. This model is very useful for the study and design of superfluid transfer systems, e.g., the Superfluid Helium Tanker (SFHT) and the Particle Astrophysics Magnet Facility (ASTROMAG).

Yuan, S. W. K.↗

Monitoring Trace Contaminants in Air Via Ion Trap Mass Spectrometry

Recent passage of the Clean Air Act with its stricter regulation of toxic gas emissions, and the ever-growing number of applications which require faster turnaround times between sampling and analysis are two major factors which are helping to drive the development of new instrument technologies for in-situ, on-line, real-time monitoring. The ion trap, with its small size, excellent sensitivity, and tandem mass spectrometry capability is a rapidly evolving technology which is well-suited for these applications. In this paper, we describe the use of a commercial ion trap instrument for monitoring trace levels of chlorofluorocarbons (CFCs) and volatile organic compounds (VOCs) in air. A number of sample introduction devices including a direct transfer line interface, short column GC, and a cryotrapping interface are employed to achieve increasing levels of sensitivity. MS, MS/MS, and MS/MS/MS methods are compared to illustrate trade-offs between sensitivity and selectivity. Filtered Noise Field (FNF) technology is found to be an excellent means for achieving lower detection limits through selective storage of the ion(s) of interest during ionization. Figures of merit including typical sample sizes, detection limits, and response times are provided. The results indicate the potential of these techniques for atmospheric assessments, the High Speed Research Program, and advanced life support monitoring applications for NASA.

Palmer, Peter T.↗

Measurement of the Shear Lift Force on a Bubble in a Channel Flow

Two-phase flow systems play vital roles in the design of some current and anticipated space applications of two-phase systems which include: thermal management systems, transfer line flow in cryogenic storage, space nuclear power facilities, design and operation of thermal bus, life support systems, propulsion systems, In Situ Resource Utilization (ISRU), and space processes for pharmaceutical applications. The design of two-phase flow systems for space applications requires a clear knowledge of the behaviors of the dispersed phase (bubble), its interaction with the continuous phase (liquid) and its effect on heat and mass transfer processes, The need to understand the bubble generation process arises from the fact that for all space applications, the size and distribution of bubbles are extremely crucial for heat and mass transfer control. One important force in two-phase flow systems is the lift force on a bubble or particle in a liquid shear flow. The shear lift is usually overwhelmed by buoyancy in normal gravity, but it becomes an important force in reduced gravity. Since the liquid flow is usually sheared because of the confining wall, the trajectories of bubbles and particles injected into the liquid flow are affected by the shear lift in reduced gravity. A series of experiments are performed to investigate the lift force on a bubble in a liquid shear flow and its effect on the detachment of a bubble from a wall under low gravity conditions. Experiments are executed in a Poiseuille flow in a channel. An air-water system is used in these experiments that are performed in the 2.2 second drop tower. A bubble is injected into the shear flow from a small injector and the shear lift is measured while the bubble is held stationary relative to the fluid. The trajectory of the bubble prior, during and after its detachment from the injector is investigated. The measured shear lift force is calculated from the trajectory of the bubble at the detachment point. These values for the shear lift are then compared with the theoretical predictions from various published works on shear lift in the open literature, which include asymptotic solutions at low bubble Reynolds number, potential flow predictions and numerical studies that deal with intermediate bubble Reynolds numbers.

Nahra, Henry K.↗

Development Testing of the Gateway Integrated Bipropellant Refueling Subsystem

The Lunar Gateway is a deep space orbiting outpost being developed by the National Aeronautics and Space Administration (NASA) in partnership with the European Space Agency (ESA) and other domestic and international partners. Because Gateway is a vital component of NASA’s Artemis program supporting long-term human exploration of the moon, it is designed for on-orbit refueling to allow for a longer life performance. The reaction control system (RCS) bipropellant refueling system onboard the station will have the capability to transfer propellants, monomethyl hydrazine (MMH) and mixed oxides of nitrogen-3 (MON-3), under controlled conditions and will span across three modules: the European System Providing Refueling Infrastructure and Telecommunication Refueling Module (ESPRIT-RM or ERM), the Habitation and Logistics Outpost (HALO), and the Propulsion and Power Element (PPE). These propellant transfers are complex operations with known hazards, and one of the risk areas is exceeding the flight system’s maximum design pressure (MDP) in priming and refueling pause/stop operations. In priming, liquid propellant is transferred from a pressurized source tank to evacuated transfer lines, which could result in excessive transient surge pressures and potentially damage hardware. In refueling pause/stop operations, fast-acting isolation valves (IV) are closed, which could lead to damaging water hammer. To mitigate these risks and develop the system, a collaborative NASA/ESA/Thales Alenia Space – United Kingdom (TAS-UK) test program was completed at TAS-UK on a simplified refueling breadboard representing ERM, HALO, and PPE bipropellant transfer systems. The objectives of the integrated breadboard testing were to (1) gather performance data to characterize and demonstrate critical refueling operations, (2) help inform flight designs, and (3) to validate numerical models that can be extended to predicting flight system performance. Integrated breadboard test data has shown the architected system performance is closing initial design assumptions. Further testing with propellant on a higher fidelity fluid simulator and analysis are planned.

Adela D Han↗

Development Testing of the Gateway Integrated Bipropellant Refueling Subsystem

The Lunar Gateway is a deep space orbiting outpost being developed by the National Aeronautics and Space Administration (NASA) in partnership with the European Space Agency (ESA) and other domestic and international partners. Because Gateway is a vital component of NASA’s Artemis program supporting long-term human exploration of the moon, it is designed for on-orbit refueling to allow for a longer life performance. The reaction control system (RCS) bipropellant refueling system onboard the station will have the capability to transfer propellants, monomethyl hydrazine (MMH) and mixed oxides of nitrogen-3 (MON-3), under controlled conditions and will span across three modules: the European System Providing Refueling Infrastructure and Telecommunication Refueling Module (ESPRIT-RM or ERM), the Habitation and Logistics Outpost (HALO), and the Propulsion and Power Element (PPE). These propellant transfers are complex operations with known hazards, and one of the risk areas is exceeding the flight system’s maximum design pressure (MDP) in priming and refueling pause/stop operations. In priming, liquid propellant is transferred from a pressurized source tank to evacuated transfer lines, which could result in excessive transient surge pressures and potentially damage hardware. In refueling pause/stop operations, fast-acting isolation valves (IV) are closed, which could lead to damaging water hammer. To mitigate these risks and develop the system, a collaborative NASA/ESA/Thales Alenia Space – United Kingdom (TAS-UK) test program was completed at TAS-UK on a simplified refueling breadboard representing ERM, HALO, and PPE bipropellant transfer systems. The objectives of the integrated breadboard testing were to (1) gather performance data to characterize and demonstrate critical refueling operations, (2) help inform flight designs, and (3) to validate numerical models that can be extended to predicting flight system performance. Integrated breadboard test data has shown the architected system performance is closing initial design assumptions. Further testing with propellant on a higher fidelity fluid simulator and analysis are planned.

Adela D Han↗

Thermal and Chemical Characterization of Non-metallic Materials Using Coupled Thermogravimetric Analysis and Infrared Spectroscopy

Thermogravimetric analysis (TGA) is widely employed in the thermal characterization of non-metallic materials, yielding valuable information on decomposition characteristics of a sample over a wide temperature range. However, a potential wealth of chemical information is lost during the process, with the evolving gases generated during thermal decomposition escaping through the exhaust line. Fourier Transform-Infrared spectroscopy (FT-IR) is a powerful analytical technique for determining many chemical constituents while in any material state, in this application, the gas phase. By linking these two techniques, evolving gases generated during the TGA process are directed into an appropriately equipped infrared spectrometer for chemical speciation. Consequently, both thermal decomposition and chemical characterization of a material may be obtained in a single sample run. In practice, a heated transfer line is employed to connect the two instruments while a purge gas stream directs the evolving gases into the FT-IR, The purge gas can be either high purity air or an inert gas such as nitrogen to allow oxidative and pyrolytic processes to be examined, respectively. The FT-IR data is collected real-time, allowing continuous monitoring of chemical compositional changes over the course of thermal decomposition. Using this coupled technique, an array of diverse materials has been examined, including composites, plastics, rubber, fiberglass epoxy resins, polycarbonates, silicones, lubricants and fluorocarbon materials. The benefit of combining these two methodologies is of particular importance in the aerospace community, where newly developing materials have little available data with which to refer. By providing both thermal and chemical data simultaneously, a more definitive and comprehensive characterization of the material is possible. Additionally, this procedure has been found to be a viable screening technique for certain materials, with the generated data useful in the selection of other appropriate analytical procedures for further material characterization.

Huff, Timothy L.↗

Thermal and Chemical Characterization of Non-Metallic Materials Using Coupled Thermogravimetric Analysis and Infrared Spectroscopy

Thermogravimetric analysis (TGA) is widely employed in the thermal characterization of non-metallic materials, yielding valuable information on decomposition characteristics of a sample over a wide temperature range. However, a potential wealth of chemical information is lost during the process, with the evolving gases generated during thermal decomposition escaping through the exhaust line. Fourier Transform-Infrared spectroscopy (FT-IR) is a powerful analytical technique for determining many chemical constituents while in any material state, in this application, the gas phase. By linking these two techniques, evolving gases generated during the TGA process are directed into an appropriately equipped infrared spectrometer for chemical speciation. Consequently, both thermal decomposition and chemical characterization of a material may be obtained in a single sample run. In practice, a heated transfer line is employed to connect the two instruments while a purge gas stream directs the evolving gases into the FT-IR. The purge gas can be either high purity air or an inert gas such as nitrogen to allow oxidative and pyrolytic processes to be examined, respectively. The FT-IR data is collected realtime, allowing continuous monitoring of chemical compositional changes over the course of thermal decomposition. Using this coupled technique, an array of diverse materials has been examined, including composites, plastics, rubber, fiberglass epoxy resins, polycarbonates, silicones, lubricants and fluorocarbon materials. The benefit of combining these two methodologies is of particular importance in the aerospace community, where newly developing materials have little available data with which to refer. By providing both thermal and chemical data simultaneously, a more definitive and comprehensive characterization of the material is possible. Additionally, this procedure has been found to be a viable screening technique for certain materials, with the generated data useful in the selection of other appropriate analytical procedures for further material characterization.

Huff, Timothy L.↗

Numerical Modeling of Fluid Transient in Cryogenic Fluid Network of Rocket Propulsion System

Fluid transients, also known as water hammer, can have a significant impact on the design and operation of both spacecraft and launch vehicles propulsion systems. These transients often occur at system activation and shut down. For ground safety reasons, many spacecrafts are launched with the propellant lines dry. These lines are often evacuated by the time the spacecraft reaches orbit. When the propellant isolation valve opens during propulsion system activation, propellant rushes into lines creating a pressure surge. During propellant system shutdown, a pressure surge is created due to sudden closure of a valve. During both activation and shutdown, pressure surges must be predicted accurately to ensure structural integrity of the propulsion system fluid network. The method of characteristics is the most widely used method of calculating fluid transients in pipeline [ 1,2]. The method of characteristics, however, has limited applications in calculating flow distribution in complex flow circuits with phase change, heat transfer and rotational effects. A robust cryogenic propulsion system analyzer must have the capability to handle phase change, heat transfer, chemical reaction, rotational effects and fluid transients in conjunction with subsystem flow model for pumps, valves and various pipe fittings. In recent years, such a task has been undertaken at Marshall Space Flight Center with the development of the Generalized Fluid System Simulation Program (GFSSP), which is based on finite volume method in fluid network [3]. GFSSP has been extensively verified and validated by comparing its predictions with test data and other numerical methods for various applications such as internal flow of turbo-pump [4], propellant tank pressurization [5,6], chilldown of cryogenic transfer line [7] and squeeze film damper rotordynamics [8]. The purpose of the present paper is to investigate the applicability of the finite volume method to predict fluid transient in cryogenic flow circuits.

Majumdar, Alok↗

Cryogenic On-Orbit Liquid Depot Storage, Acquisition, and Transfer Satellite (COLD-SAT)

The Cryogenic On-Orbit Liquid Depot Storage, Acquisition, and Transfer Satellite (COLD-SAT) will perform subcritical liquid hydrogen handling experiments under low gravity conditions to provide engineering data for future space transportation missions. Comprising the four Class 1 enabling experiments are tank press control, tank chilldown, tank no-vent fill, and liquid acquisition device fill/refill. The nine Class 2 enhancing experiments are tanker thermal performance, pressurization, low-gravity setting and outflow, liquid acquisition device performance, transfer line chilldown, outflow subcooling, low-gravity vented fill, fluid dumping, and advanced instrumentation. Consisting of an experiment module mated to a spacecraft bus, COLD-SAT will be placed in an initial 1300 km circular orbit by an Atlas commercial launch vehicle, and will perform experiments in a semi-autonomous mode for a period of up to six months. The three-axis controlled spacecraft bus provides electric power, control and data management, communications, and attitude control along with propulsive acceleration levels ranging from 10(exp -6) to 10(exp -4) g. It is desired to understand the effects that low acceleration levels might have on the heat and mass transfer processes involved in some of the experiments. The experiment module contains the three liquid hydrogen tanks, valves, pressurization and pumping equipment, and instrumentation. Within the highly insulated tanks are specialized fluid management equipment that might be used in future space transportation systems. At launch all the liquid hydrogen for the experiments is contained in the largest tank, which has helium-purged insulation to prevent cryo-pumping of air on the launch pad. The tank is loaded by the hydrogen tanking system used for the Centaur upper stage of the Atlas. After reaching orbit the two smaller tanks become receivers for fluid transfers, and when tanked, become the vessels for performing many of the experiments.

Schuster, John R.↗

Flow Boiling and Condensation Experiment: Flow Boiling in a Rectangular Channel with Subcooled Inlet Conditions in Microgravity

Two-phase thermal management subsystems that take advantage of both the sensible and latent heat of a working fluid can potentially yield significant enhancements in overall performance by adopting heat transfer processes that are based on phase transition like boiling and condensation. Performance of terrestrial two-phase flow systems may be predictable because the hydrodynamic and body forces are understood, however, in microgravity, which is predominant during planetary space travel, forces that are masked by the strong body force on Earth (gravitational or buoyancy force) reappear with different magnitude and influence. The need arose for a facility that provides for two-phase flow with phase transition testing in microgravity. The Flow Boiling and Condensation Experiment (FBCE) is a facility that was launched to the International Space Station in August of 2021 and is in operation since February of 2022. This facility enables investigators to perform two-phase flow and phase transition research in flow boiling and condensation. Along with the test module that is experiment specific, the FBCE system consists of the fluid, avionics, and software subsystems. Currently two test modules, namely, the Flow Boiling Module (FBM) and the Condensation Module for Heat Transfer (CM-HT) are available. A third module, the Transfer Line test Module (TL) is being developed. The fluid subsystem conditions and delivers the fluid at the desired thermodynamic state to the test module. It consists of two fluid modules and a heater module that are connected by flex hoses for fluid circulation and by data and electrical cables for control and data acquisition. Two avionics modules acquire pressure and temperature data from various sensors in the flow loop. For FBM, a high-speed camera is available to acquire images of the boiling process. Experiments are operated autonomously by software and are based on an Experiment Parameters Master Table (EPMT) that is uploaded to ISS and is executed by the FBCE flight software. This presentation briefly introduces the objectives of FBCE and provides a system description of the experiment onboard of the ISS/Fluid Integrated Rack (FIR). Results of the test campaign carried out using the FBM are presented. Specifically, microgravity flow boiling of n-perfluorohexane (test fluid) is discussed with subcooled inlet conditions in a single-side-heated rectangular channel of dimensions 114.6-mm heated length, 2.5-mm heated width, and 5.0-mm height. Key operating parameters investigated are mass velocity (199.90 – 3200.13 kg/m2s), inlet subcooling (0.10 – 45.76°C), and inlet pressure (113.30 – 164.29 kPa). Image sequences acquired via high-speed-video are shown to elucidate the interfacial flow physics. The effects of various parameters on flow boiling heat transfer in microgravity, from the onset of boiling to the critical heat flux are discussed. Heat transfer results are presented in terms of flow boiling curves, streamwise profiles of wall temperature and heat transfer coefficient, and parametric trends of local and averaged heat transfer coefficient, and the critical heat flux.

Two-phase flow and phase transition↗

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Hydrogen

Developing accurate models of two-phase cryogenic flow will reduce risk and reduce margins for future NASA vehicles such as the Nuclear Thermal Propulsion (NTP) system. Currently there is a need for more accurate, direct cryogenic data-anchored models for various boiling and two-phase phenomena. The focus of the current work is on modeling steady state cryogenic flow boiling in the transfer line that connects a propellant storage tank to an engine or customer receiver tank. This paper presents Thermal Desktop model validation results against several historical liquid hydrogen (LH2) heated tube experiments that cover a wide range of inlet conditions, mass flux, and heat flux. New universal cryogenic flow boiling correlations were recently developed and anchored to the largest cryogenic flow boiling database assembled in the world to-date. The new universal correlations are patched together and implemented into Thermal Desktop to compare model performance against the built-in flow boiling correlations. Axial wall temperature predictions as a function of preponderant parameters like heat flux, mass flux, inlet pressure, inlet quality, tube diameter, etc. using the two sets of flow boiling correlations are compared against the experimental data. Overall, the Thermal Desktop model with the new universal cryogenic flow boiling correlations demonstrates an improvement in predictive performance over the Thermal Desktop model using built-in correlations for both wall temperature and location of critical heat flux compared to the data for LH2 flow boiling in heated tubes.

Cryogenic Propellant Transfer↗

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Hydrogen

Developing accurate models of two-phase cryogenic flow will reduce risk and reduce margins for future NASA vehicles such as the Nuclear Thermal Propulsion (NTP) system. Currently there is a need for more accurate, direct cryogenic data-anchored models for various boiling and two-phase phenomena. The focus of the current work is on modeling steady state cryogenic flow boiling in the transfer line that connects a propellant storage tank to an engine or customer receiver tank. This paper presents Thermal Desktop model validation results against several historical liquid hydrogen (LH2) heated tube experiments that cover a wide range of inlet conditions, mass flux, and heat flux. New universal cryogenic flow boiling correlations were recently developed and anchored to the largest cryogenic flow boiling database assembled in the world to-date. The new universal correlations are patched together and implemented into Thermal Desktop to compare model performance against the built-in flow boiling correlations. Axial wall temperature predictions as a function of preponderant parameters like heat flux, mass flux, inlet pressure, inlet quality, tube diameter, etc. using the two sets of flow boiling correlations are compared against the experimental data. Overall, the Thermal Desktop model with the new universal cryogenic flow boiling correlations demonstrates an improvement in predictive performance over the Thermal Desktop model using built-in correlations for both wall temperature and location of critical heat flux compared to the data for LH2 flow boiling in heated tubes.

cryogenic propellant transfer↗