Search NASA⌕ Search

SEARCH · Search NASA

Results for “transient behavior”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Nonlinear analysis of a family of LC tuned inverters

Four widely used self-oscillating dc-to-square-wave parallel inverters which employ an inductor-capacitor tuned network to determine the oscillation frequency are reduced to a common equivalent RLC network, The techniques of singular-point analysis and state-plane interpretations are employed to describe the steady-state and transient behavior of these circuits and to elucidate the three possible modes of operation: quasi-harmonic, relaxation, and discontinuous. Design guidelines are provided through a study of the influence of circuit parameter variations on the characteristics of oscillation and on frequency stability. Several examples are provided to illustrate the usefulness of this analysis when studying such problems as transistor emitter-to-base junction breakdown during oscillations and the design of starting circuits to insure self-excited oscillations in these inverters.

Lee, F. C. Y.↗

Behaviour of nitric oxide trails deposited in the mesosphere and stratosphere

The transient behavior of a nitric oxide trail deposited at approximately 60 km altitude is studied by the solution of the appropriate multidimensional diffusion equation which includes terms representing the effects of wind shear. Similar analysis is then carried out for the situation in the stratosphere. Trail behavior is found to be relatively independent of altitude and background ozone, but strongly dependent on the magnitude of eddy diffusity and the initial nitric oxide concentration. The nitric oxide trail reacts with ambient ozone to form nitrogen dioxide. For a trail 100 m initial radius, an ozone hole will form to a maximum size in 4 to 6 hours and then decay. The overall recovery time of the atmosphere following the creation of the trail is less than 12 hours.

Eberstein, I. J.↗

A model for the X-ray nova A0620-00

The model involves a white dwarf accreting mass from a late-type subgiant companion. The transient behavior of the X-ray source is explained by the instability to mass loss of the companion (as in Algol-type binaries). The brightening, spectrum, and decay timescale of the optical counterpart are explained in terms of re-emission of X-radiation intercepted by the subgiant. It was concluded that A0620-00 can provide an excellent test case for numerical models of stellar atmospheres irradiated by an external X-ray flux.

Endal, A. S.↗

Experimental study of transient dynamics of a flexible rotor

The results of an experimental program to investigate the transient response of a flexible rotor are presented. The program consisted of a series of tests conducted on a rig with a rotor designed to operate above its first bending critical speed. The purpose of the tests was to obtain experimental data on the transient behavior of a flexible rotor under conditions simulating those which might occur in a jet aircraft engine. The scope of the program included tests to measure the response of both balanced and unbalanced rotors during steady-state operation, acceleration, deceleration, and simulated blade loss.

Hibner, D. H.↗

Application of axial grooves to cryogenic variable conductance heat pipe technology

Tests results obtained with an ATS axial groove aluminum extrusion adapted for use as a cryogenic thermal diode and/or a variable conductance heat pipe are presented. Ethane at a nominal operating temperature of 185 C was used as working fluid. In addition to both active and passive gas control, diode designs utilizing gas blockage or liquid trap were investigated. Specific requirements and performance parameters such as transient behavior, reservoir sizes, shutdown energy, etc., were evaluated. Results are also presented for tests where the liquid trap was used as a secondary heat pipe to demonstrate thermal switching with simultaneous heat pipe operation and diode shutdown.

Brennan, P. J.↗

A generalized correlation of experimental flat-plate collector performance

A generalized correlation of flat-plate collector performance obtained by outdoor and indoor test methods is presented. This correlation shows that the indoor (simulator) test approach is a special case of the general situation of variable solar conditions. The important feature of the generalized correlation is that it permits a separation of the solar variables (flux, incident angle, etc.) which affect collector performance from the collector parameters (absorptance, transmittance, heat loss, etc.) which also affect collector performance and which are uniquely part of a given collector design. The correlation permits an evaluation of the relative merits of using instantaneous, hourly and daily collector efficiencies in obtaining a good collector correlation. The question of the transient behavior outdoors of a collector is an important part of determining whether to use instantaneous, hourly or daily efficiency values in a correlation approach. Correlation of the experimental performance of collectors allows the following: (1) comparisons of different collector designs, (2) collector performance prediction under conditions that differ from the conditions of the test program, and (3) monitoring performance degradation effects.

Simon, F. F.↗

The dynamic transfer function for a cavitating inducer

Knowledge of the dynamic performance of pumps is essential for the prediction of transient behavior and instabilities in hydraulic systems; the necessary information is in the form of a transfer function which relates the instantaneous or fluctuating pressure and mass flow rate at inlet to the same quantities in the discharge from the pump. The presence of cavitation within the pump can have a major effect on this transfer function since dynamical changes in the volume of cavitation contribute to the difference in the instantaneous inlet and discharge mass flow rates. The present paper utilizes results from free streamline cascade theory to evaluate the elements in the transfer function for a cavitating inducer and shows that the numerical results are consistent with the characteristics observed in some dynamic tests on rocket engine turbopumps.

Brennen, C.↗

The transient periodic X-ray source in Taurus, A0535+26

Eighteen X-ray light curves of the 104-sec periodicity in the Taurus X-ray nova A 0535+26 are analyzed which were obtained by SAS-3 in six energy intervals between 1 and 35 keV during the period from May 30 to June 2, 1975. It is shown that the pulse structure is relatively simple at energies above 19 keV, but develops a complex series of five irregularly spaced maxima at lower energies. The energy spectrum averaged over the 104-sec period is found to be extremely hard, with a best-fit temperature of about 30 keV for the exponential spectrum, an excess at about 15 keV, and a steepening above 20 keV. It is suggested that A 0535+26 may be a compact object in a binary system containing the peculiar Be star HDE 245770. The transient behavior could arise due to episodic mass loss by the primary or because the compact object is in a highly eccentric orbit about the companion, with appreciable mass transfer occurring only at periastron.

Bradt, H.↗

A model for the X-ray nova A0620-00

A model is proposed for the transient X-ray source A0620-00 involving a white dwarf accreting mass from a late-type subgiant companion. The transient behavior of the X-ray source is explained by the instability to mass loss of the companion (as in Algol-type binaries). The brightening, spectrum, and decay timescale of the optical counterpart are explained in terms of re-emission of X-radiation intercepted by the subgiant. A0620-00 should provide an excellent test case for numerical models of stellar atmospheres irradiated by an external X-ray flux.

Endal, A. S.↗

A 15,000-hour cyclic endurance test of an 8-centimeter-diameter electron bombardment mercury ion thruster

A laboratory model 8 cm thruster with improvements to minimize ion chamber erosion and peeling of sputtered metal was subjected to a cyclic endurance test for 15,040 hours and 460 restarts. A charted history of several thruster operating variables and off-normal events are shown in 600-hour segments at three points in the test. The transient behavior of these variables during a typical start-stop cycle is presented. Finding of the post-test inspection confirmed most of the expected results. Charge exchange ions caused normal accelerator grid erosion. The workability of the various design features was substantiated, and attainable improvements in propellant utilization efficiency should significantly reduce accelerator erosion.

Nakanishi, S.↗

A 15,000-hour cyclic endurance test of an 8-centimeter-diameter electron bombardment mercury ion thruster

A laboratory model 8-cm thruster with improvements to minimize ion chamber erosion and peeling of sputtered metal was subjected to a cyclic endurance test for 15,040 hours and 460 restarts. A charted history of several thruster operating variables and off-normal events are shown in 600-hour segments at three points in the test. The transient behavior of these variables during a typical start-stop cycle is presented. Performance and operating characteristics were nearly constant throughout the test except for a change in the accelerator back-streaming limit. Findings of the post-test inspection confirmed most of the expected results. Charge-exchange ions caused normal accelerator grid erosion. The workability of the various design features have been substantiated, and attainable improvements in propellant utilization efficiency should significantly reduce accelerator erosion.

Nakanishi, S.↗

Tests and evaluation of multihundred watt thermoelectric generators at JPL

The multihundred watt (MHW) thermoelectric generator, based on silicon-germanium thermoelectric technology, delivers a nominal power output of 150 watts with an efficiency of about 6%. The two Voyager space probes each use three such generators assembled in tandem on a boom. A total of seven MHW type thermoelectric generators were tested at JPL in support of the Voyager project. The tests consisted of: (1) parametric evaluation of the electrical characteristics of the devices over a wide range of output voltage for different values of input power, different operating ambients (air, vacuum), and different internal environments (argon, helium, xenon, mixture of these gases, and vacuum) at different pressures to allow evaluation of the influences of both gas and pressure on the performance of the generator; (2) tests to determine the transient behavior of the generators; and (3) operation of the generator in conjunction with the Voyager spacecraft.

Rouklove, P.↗

Extended Development of Variable Conductance Heat Pipes

A high-capacity vapor-modulated heat pipe was designed and tested. In 1977, a program was undertaken to use the aforementioned heat pipe to study protection from freezing-point failure, increase control sensitivity, and transient behavior under a wide range of operating conditions in order to determine the full performance potential of the heat pipe. A new concept, based on the vapor-induced-dry-out principle, was developed for passive feedback temperature control as a heat pipe diode. This report documents this work and describes: (1) the experimental and theoretical investigation of the performance of the vapor-modulated heat pipe; and (2) the design, fabrication and test of the heat pipe diode.

Antoniuk, D.↗

Discrete time domain modelling and analysis of dc-dc converters with continuous and discontinuous inductor current

Using discrete time state variable representation, a generalized computer-aided modeling and analysis of dc-dc converters is presented. The methodology provides exact modeling and is applicable to all types of power stages and duty-cycle control, including continuous and discontinuous inductor current operation. Converter stability, transient behavior and audio susceptibility can be analytically evaluated and predicted. The generalized theory of the proposed approach to converter modeling and analysis is presented first, followed by a demonstrative example applying the theory to a constant frequency buck converter operating in continuous and discontinuous inductor current mode. Excellent agreement with laboratory test data has been observed.

Iwens, R. P.↗

Concentrating solar collector-performance tests

Report summarizes test results from evaluation of concentrating solar collector thermal performance, from transient behavior, and incident-of-angle behavior. Tests were conducted using National Bureau of Standards recommedations and specifications.

Source record↗

Observations of the transient X-ray source 4U0115+63

Results of HEAO-2 pointed observations and Ariel 5 All Sky Monitor observations of the X-ray transient 4U0115+63 are presented. The transient source pulses with a period of 3.6136 s + or - .0004 s, has a hard spectrum typical of an X-ray binary pulsar, and has a broad iron line emission feature. A discussion of the transient behavior is given and inferences are made concerning the nature of the X-ray source based on the pointed data.

Rose, L. A.↗

Observations of the transient X-ray source 4U 0115+63

Results are presented for HEAO A-2 pointed observations and Ariel 5 A11-Sky Monitor observations of the X-ray transient 4U 0115 + 63. The transient source pulses with a period of 3.6136 s + or - 0.0004 s, has a hard spectrum typical of an X-ray binary pulsar, and has a broad iron line emission feature. A discussion of the transient behavior is given, and inferences are made concerning the nature of the X-ray source based on the pointed data.

Rose, L. A.↗

CADAT field-effect-transistor simulator

CADAT field-effect transistor simulator (FETSIM) analyzes dc and transient behavior of metal-oxide-semiconductor (MOS) circuits. Both N-MOS and P-MOS transistor configurations in either bulk of silicon-on-sapphire (SOS) technology and almost any combination of R/C elements are analyzed.

Source record↗