Search NASA⌕ Search

SEARCH · Search NASA

Results for “transient storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

Isothermal Versus Sensible Cold Storage: A Model-Based Performance Comparison for Pumped Thermal Electricity Storage

Pumped-thermal energy storage (PTES) systems consume and produce electrical energy using thermal storage media as an intermediate stage. PTES lends itself to long-duration energy storage to facilitate high penetration of intermittent electricity generation. This study presents a model-based comparison of two thermal storage types within a PTES system: a conventional, single-phase, stratified water-glycol sensible storage system (SGS), and an ideal isothermal, two-phase heat exchanger that freezes a water reservoir (isothermal heat exchanger (IHEX)). The SGS thermal storage capacity is based on the liquid’s sensible heat change with temperature, whereas the capacity of the IHEX is based on the latent heat of isothermally freezing and melting water. The idealized IHEX modeled here undergoes steady-state melting and freezing (in contrast to transient rates, as observed with ice-on-coil storage). A computational model of a complete PTES system is presented and used to evaluate the PTES system-level performance with each type of cold storage. Compared to SGS-based PTES, under nominal operating conditions, the IHEX-based PTES increased electrical round-trip efficiency from 61% to 82% and increased energy density from 1.13 to 8.09 kWh/m 3 In conclusion, the performance of the PTES configured with IHEX storage was also analyzed under varying operating parameters.

25 ENERGY STORAGE↗

Analytical solutions to the problem of transient heat transfer in living tissue.

An analytical model of transient heat transfer in living biological tissue is considered. The model includes storage, generation, conduction, and convective transport of heat in the tissue. Solutions for rectangular and cylindrical coordinates are presented and discussed. Transient times for reaching the ?locally fully developed' temperature profile were found to be of the order of 5 to 25 min. These transients are dominated by a geometrical parameters and, to a lesser extent, by a parameter representing the ratio of heat supplied by blood flow to heat conducted in the tissue.

Shitzer, A.↗

Control System of Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS) & HIL Platforms for Design

Multi-port autonomous reconfigurable solar power plant (MARS) provides an attractive alternative to connect photovoltaic (PV) and energy storage systems (ESSs) to high-voltage direct current (HVdc) links and high-voltage alternating current (ac) grids. In this paper, a unique hierarchical control system of MARS is proposed and evaluated. To evaluate the control system and associated algorithms in early-stage research of complex architectures like MARS, it is important to develop unique suitable hardware-in-the-loop (HIL) platforms. In this paper, the HIL platforms for MARS to evaluate the performance of the hierarchical control system and the control algorithms implemented are presented. Further, they help with the design process of control systems. The real-time simulation models and algorithms that are utilized for MARS in the HIL platforms are also discussed in the paper. The HIL experiments of the control system of MARS showcase the capability to provide continuity of operation under faults and frequency support to the power grid during loss of generation. They also showcase the stability of the proposed hierarchical control system of MARS.

14 SOLAR ENERGY↗

A review of candidate multilayer insulation systems for potential use on wet-launched LH2 tankage for the Space Exploration Initiative lunar missions

The storage of cryogenic propellants such as liquid hydrogen (LH2) and liquid oxygen (LO2) for the future Space Exploration Initiative (SEI) will require lightweight, high performance thermal protection systems (TPSs). For the near-term lunar missions, the major weight element for most of the TPSs will be multilayer insulation (MLI) and/or the special structures/systems required to accommodate the MLI. Methods of applying MLI to LH2 tankage to avoid condensation or freezing of condensible gases such as nitrogen or oxygen while in the atmosphere are discussed. Because relatively thick layers of MLI will be required for storage times of a month or more, the transient performance from ground-hold to space-hold of the systems will become important in optimizing the TPSs for many of the missions. The ground-hold performance of several candidate systems are given as well as a qualitative assessment of the transient performance effects.

Knoll, Richard H.↗

A review of candidate multilayer insulation systems for potential use on wet-launched LH2 tankage for the space exploration initiative lunar missions

The storage of cryogenic propellants such as liquid hydrogen (LH2) and liquid oxygen (LO2) for the future Space Exploration Initiative (SEI) will require lightweight, high performance thermal protection systems (TPS's). For the near-term lunar missions, the major weight element for most of the TPS's will be multilayer insulation (MLI) and/or the special structures/systems required to accommodate the MLI. Methods of applying MLI to LH2 tankage to avoid condensation or freezing of condensible gases such as nitrogen or oxygen while in the atmosphere are discussed. Because relatively thick layers of MLI will be required for storage times of a month or more, the transient performance from ground-hold to space-hold of the systems will become important in optimizing the TPS's for many of the missions. The ground-hold performance of several candidate systems are given as well as a qualitative assessment of the transient performance effects.

Knoll, Richard H.↗

SSV Launch Monitoring Strategies: HGDS Design and Development Through System Maturity

This poster presentation reviews the design and development of the Hazardous Gas Detection System (HGDS). It includes a overview schematic of the HGDS, pictures of the shuttle on the Mobile Launch platform, the original HGDS, the current HGDS and parts of the original and current system. There are charts showing the dynamics of the orbiter during external tank loading, and transient leaks observed on HGDS during Power Reactant Storage and Distribution (PRSD) load.

Shoemaker, Marc D.↗

PHIL Validation of Ultracapacitor Storage for Black Start Application

A deck of slides that present the modeling, and calibration to conduct PHIL test of ultracapacitor energy storage system. The PHIL test has been done while preparing for the black start field demonstration with Idaho Falls Power. Presentation is invited to the 6th International Workshop on Grid Simulator Testing of Wind Turbine Power Trains and Other Renewable Technologies.

13 HYDRO ENERGY↗

Frequency Control and Disturbance Containment Using Grid-Forming Embedded Storage Networks

The paper presents a distributed approach for operating a network of inverter-based energy storage resources embedded in a bulk power system. Departing from their traditional role of steady-state reserves, the storage assets in the network are utilized as frequency-responsive resources shaping system dynamics. The power electronics converter systems interfacing the storage resources are equipped with local controllers designed to respond under transient disturbances. To this end, a safety-constrained distributed control strategy is explored. The paper compares the performance of converter-interfaced grid-forming and grid-following storage networks for fast frequency control and disturbance containment/localization. Sensitivity studies are performed to study the impact of storage size, steady-state dispatch, and controller design on dynamic performance. The findings are presented through case studies with results from the IEEE test systems.

Chatterjee, Kaustav (ORCID:0000000153273860)↗

Anomalous Transients in Chip Polymer Tantalum Capacitors

Contrary to MnO2 tantalum capacitors, transient processes in polymer tantalum capacitors after voltage application might result in anomalously high, ampere-level currents when a capacitor might appear as a short circuit for a time that is much greater than a transient time in MnO2 capacitors. In this work, conditions that cause anomalous transients in different types of polymer tantalum capacitors have been analyzed. Related phenomena that included increasing of capacitance and dissipation factors with voltage, parametric surge current test failures without damage to capacitors, and increasing leakage currents at low temperatures are described. It has been shown that anomalous transients increased substantially with applied voltage and with reduction of moisture content in capacitors caused by storage or operation at high temperatures and/or in vacuum. Different types of capacitors exhibited different level of transients and modification of conductive polymers or process of their application might decrease transient leakage currents substantially. For space applications, the risk of failures related to anomalous transients can be mitigated by special testing procedures to select parts with an acceptable level of transients and by voltage derating.

Tantalum Capacitors↗

Simulation of Unsteady Combustion in a Ramjet Engine Using a Highly Parallel Computer

Combustion instability in ramjets is a complex phenomenon that involve nonlinear interaction between acoustic waves, vortex motion and unsteady heat release in the combustor. To numerically simulate this 3-D, transient phenomenon, enormous computer resources (time, memory and disk storage) are required. Although current generation vector supercomputers are capable of providing adequate resources for simulations of this nature, their high cost and limited availability, makes such machines less than satisfactory for routine use. The primary focus of this study is to assess the feasibility of using highly parallel computer systems as a cost-effective alternative for conducting such unsteady flow simulations. Towards this end, a large-eddy simulation model for combustion instability was implemented on the Intel iPSC/860 and a careful study was conducted to determine the benefits and the problems associated with the use of such machines for transient simulations. Details of this study along with the results obtained from the unsteady combustion simulations carried out on the iPSC/860 are discussed in this paper.

Menon, Suresh↗

Ultra-High Temperature Thermal Conductivity Measurements of a Reactive Magnesium Manganese Oxide Porous Bed Using a Transient Hot Wire Method

Pelletized magnesium manganese oxide shows promise for high temperature thermochemical energy storage. It can be thermally reduced in the temperature range between 1250 °C and 1500 °C and re-oxidized with air at typical gas-turbine inlet pressures (1–25 bar) in the temperature range between 600 °C and 1500 °C. The combined thermal and chemical volumetric energy density is approximately 2300 MJ/m3. The rate at which a thermochemical storage module can be charged is limited by heat transfer inside the solid packed bed. Hence, the effective thermal conductivity of packed beds of magnesium-manganese oxide pellets is a crucial parameter for engineering Mg-Mn-O redox storage devices. We have measured the effective thermal conductivity of a packed bed of 3.66 ± 0.516 mm sized magnesium manganese oxide (Mn to Mg molar ratio of 1:1) pellets in the temperature range of 300–1400 °C. Since the material is electrically conductive at temperatures above 600 °C, the sheathed transient hot wire method is used for measurements. Raw data is analyzed using the Blackwell solution to extract the bed thermal conductivity. The effective thermal conductivity standard deviation is less than 10% for a minimum of three repeat measurements at each temperature. Experimental results show an increase in the effective thermal conductivity with temperature from 0.50 W/m °C around 300 °C to 1.81 W/m °C close to 1400 °C. We propose a dual porosity model to express the effective thermal conductivity as a function of temperature. This model also considers the effect of radiation within the bed, as this is the dominant heat transfer mode at high temperatures. The proposed model accounts for microscale pellet porosity, macroscale bed porosity, pellet size, solid thermal conductivity (phonon transport), and radiation (photon transport). The coefficient of determination between the proposed model and the experimental results is greater than 0.90.

Engineering↗

Hydride Reprecipitation in Prototypical 17x17 PWR Fuel Rods after Simulated Vacuum Drying Conditions

Light water reactor (LWR) fuel rod cladding picks up hydrogen as it oxidizes in reactor. Once the hydrogen concentration exceeds the solubility limit, zirconium hydride platelets precipitate, generally in the circumferential direction. In preparation for dry storage, elevated temperatures can dissolve some of the circumferential hydrides, which during cooling can then reprecipitate in a direction perpendicular to the hoop stress (radially). From 2019 to 2024, ORNL published a series of reports that included metallographic observations of cladding after a thermal transient to 400°C followed by slow cooling. The simulated dry storage process was performed on three full-length 17x17 PWR fuel rods at their as-discharged rod internal pressure. There were two important observations from the metallographic examinations of these heat-treated rods: (1) the propensity for hydride reorientation is strongly influenced by nearby as-discharged precipitated hydrides, (2) the radial hydrides observed near the cladding inner diameter were often associated with cracks in the pellet. Subsequent modeling using the BISON fuel performance code that considered the effects of pellet cracks and pellet-cladding bonding observed in high-burnup fuel support the conclusion that pellet cracks enhance the local hoop stress in the cladding creating preferential sites for hydride reorientation, and that the influence of the pellet cannot be ignored in accurate fuel rod performance predictions.

Montgomery, Rose [ORNL] (ORCID:0000000286038936)↗

Global kinetic modeling of NH 3 -SCR with two sites of NH 3 storage on Cu-SSZ-13

A comprehensive selective catalytic reduction (SCR) model is developed to detail the global kinetic reactions in the catalyst which is involved in two type of sites for high- and low-temperature NH 3 adsorption/desorption, as well as a low temperature H 2 O storage. The model accounts for the formation of ammonium nitrate in fast SCR and the decomposition formation of ammonium nitrate in the absence of NO, and addresses N 2 O relative to NO and NO 2 reactions with NH 3 . The model has been validated against commercial Cu-SSZ-13 measurements of NH 3 inventory, NH 3 oxidation, NO oxidation, standard SCR, fast SCR and NO 2 SCR at both comprehensive steady-state and transient conditions. In addition, the application of the SCR model for emissions control over a transient drive cycle at cold start was demonstrated based on diesel oxidation catalyst (DOC) and SCR aftertreatment system for a passenger car. In conclusion, the results show that the SCR model can provide the detailed emissions estimations for steady-state and transient conditions, can assist with understanding the impact of the SCR reaction mechanism, and can assist with the design and optimization of SCR catalysts to develop innovative technologies for co-optimization of engine fuel economy and emissions control technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cloud-based implementation of white-box model predictive control for a GEOTABS office building: A field test demonstration

Model predictive control (MPC) has been proven in simulations and pilot case studies to be a superior control strategy for large buildings. MPC can utilize the weather and occupancy schedule forecasts, together with the system model, to predict the future thermal behavior of the building and minimize the overall energy use and maximize thermal comfort. However, these advantages come with the cost of increased modeling effort, computational demands, communication infrastructure, and commissioning efforts. Thus a typical approach is to, often rapidly, simplify the building modeling and MPC optimization problem while paying a price of not reaching the full performance potential. It has been shown that by employing accurate physics-based models, MPC performance can be notably increased closer to its theoretical performance bound. However, implementation of such high-fidelity MPC in real buildings remains a challenge, resulting in a lack of successful field test studies. This work presents the methodology and field test demonstration of a computationally efficient implementation of the white-box MPC in an office building in Belgium. The detailed model of the building is based on first-principle physical equations. The deployment and supervision of MPC operation in a practical setting are supported by an automated cloud-based communication infrastructure. The motivating factor behind the cloud-based architecture is its compatibility with a commercially appealing control as a service concept. The building is equipped with a ground source heat pump (GSHP) and thermally activated building structures (TABS), where the combination of both is also known as GEOTABS. From a control perspective, GEOTABS buildings are particularly challenging systems due to large scale, complex heating, ventilation and air conditioning (HVAC) system, and slow dynamics with time delays. On the other hand, there is an increased potential for energy savings due to the high thermal mass, which acts as thermal storage. The MPC operation is demonstrated during the challenging transient seasons (switching between heating and cooling), and its performance is compared to a traditional rule-based controller (RBC). We provide a proof of concept of real MPC operation for the most difficult seasons with notable GSHP energy use savings equal to 53.5% and thermal comfort improvement by 36.9%. Other MPC applications found in the literature describe tests for only cooling or only heating, and up to now only for a black-box or a grey-box approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The evolution of organic mantles on interstellar grains

By laboratory simulation of the chemical processes on dust grains it was investigated how solid organic materials can be produced in the interstellar medium. The ice mantles that accrete on grains in molecular clouds, consisting primarily of H2O, CO, H2CO, NH3, and O2, are irradiated by the internal UV field, resulting in the storage of radicals upon photodissociation of the original molecules. Transient heating events lead to the production of oxygen-rich organic species by recombination reactions. The experiments indicated that in this way the observed amount of organic material can be produced if a grain passes a few times through a molecular cloud during its life. After the destruction of the cloud the grains enter a more diffuse medium. Here they are subjected to the interstellar UV field as well as to collisions with atomic hydrogen. Experiments show that the intense photoprocessing results in the removal of small species like H2O and NH3 as well as in carbonization of the organic molecules. Contrary to this, the atomic H flux will maintain a certain hydrogen level in the mantle. These processes likely convert the original, oxygen-rich organics into an unsaturated hydrocarbon type material such as that observed towards IRS 7 and in Comet Halley grains.

Schutte, Willem A.↗

Numerical analysis of flow and heat transfer in the VAFB LOX storage Dewar tank

The present report describes numerical simulation of three-dimensional transient distributions of velocity and temperature of liquid oxygen (LOX) in the LOX Dewar tank of Vendenberg Air Force Base (VAFB). The present analyses cover the replenish time period only. Four test cases have been considered. For all four cases, the input boundary conditions are comprised of LOX facility heat loads, drain flow rates, recirculation flow rates and dewar heating. All the quantities are prescribed as functions of time. The first two test cases considered sensitivity of results to the computational grid. In Case 3, system heat load was changed, while in Case 4, a lower LOX level was specified. Cases 1 and 2 showed that the temperatures were not sensitive to the grid refinement. This provided a basic check on the numerical model. Cases 3 and 4 showed that the thermal boundary layer motion near the tank surface becomes more significant at the late time, e.g., 5 1/2 hours from replenish start. Comparison between results of Cases 3 and 4 showed, as expected, that the smaller initial LOX volume given in Case 4, results in higher temperature level. All calculated velocity and temperature distributions were found to be plausible.

Tam, L. T.↗