At least 109 records · Page 6

Space power development impact on technology requirements

The paper is concerned with the selection of a specific spacecraft power technology and the identification of technology development to meet system requirements. Requirements which influence the selection of a given technology include the power level required, whether the load is constant or transient in nature, and in the case of transient loads, the time required to recover the power, and overall system safety. Various power technologies, such as solar voltaic power, solar dynamic power, nuclear power systems, and electrochemical energy storage, are briefly described.

Cassidy, J. F.↗

Two-Phase Convection Heat Transfer Correlations for Liquid Hydrogen Pipe Chilldown

Recently, heat transfer correlations based on liquid nitrogen (LN2) and liquid hydrogen (LH2) pipe quenching data were developed to improve the predictive accuracy of lumped node codes like SINDA/FLUINT and the Generalized Fluid System Simulation Program (GFSSP). After implementing these correlations into both programs, updated model runs showed strong improvement in LN2 pipe chilldown modeling but only modest improvement in LH2 modeling. Due to large differences in thermal and fluid properties between the two fluids, results indicated a need to develop a separate set of LH2-only correlations to improve the accuracy of the simulations. This paper presents a new set of two-phase convection heat transfer correlations based on LH2 pipe quenching data. A correlation to predict the bulk vapor temperature was developed after analysis showed that high amounts of thermal nonequilibrium of the liquid and vapor phases occurred during film boiling of LH2. Implemented in a numerical model, the new correlations achieve a mean absolute error of 19.5 K in the predicted wall temperature when compared to recent LH2 pipe chilldown data, an improvement of 40% over recent GFSSP predictions. This correlation set can be implemented in simulations of the transient LH2 chilldown process. Such simulations are useful for predicting the chilldown time and boil-off mass of LH2 for applications such as the transfer of LH2 from a ground storage tank to the rocket vehicle propellant tank, or through a rocket engine feedline during engine startup.

critical heat flux↗

Evaluation of Electrical System Requirements for Implementing Turbine Electrified Energy Management

Turbine Electrified Energy Management (TEEM) is a concept concerned with the management of energy in an electrified propulsion system. The management of energy in the hybrid-electric architecture has potential to benefit the turbomachinery and the aircraft it powers. The concept is particularly useful for improving operability during transient operation and could be leveraged to design a better performing engine. The concept utilizes electric machines coupled to the engine shafts and an electric power distribution system that includes energy storage. A controller is used to decide when and how energy is moved around the electrified propulsion system, particularly when considering energy conversion between mechanical and electrical forms. Prior work has shown that the electric machines can be used to supply/or extract supplemental power to/from the engine shafts to improve their operability and achieve or enable propulsion efficiency and performance benefits. However, the previous studies did not consider the practical constraints of the electrical machines and energy storage devices that are required for implementing the TEEM system architecture concept. This paper presents an integrated engine and electrical system model that is used to evaluate the electrical system requirements. The model captures the physics of the conceptual, Advanced Geared Turbofan 30,000lbf (AGTF30) engine, which features advanced technologies such as a compact gas turbine and a variable area fan nozzle. For this work, the engine is augmented with electrical system components that allow for the implementation of the TEEM concept. The evaluation presented suggests the potential of the TEEM concept to provide performance benefits for a turbofan engine.

electrified↗

Evaluation of Electrical System Requirements for Implementing Turbine Electrified Energy Management

Turbine Electrified Energy Management (TEEM) is a concept concerned with the management of energy in an electrified propulsion system. The management of energy in the hybrid-electric architecture has potential to benefit the turbomachinery and the aircraft it powers. The concept is particularly useful for improving operability during transient operation and could be leveraged to design a better performing engine. The concept utilizes electric machines coupled to the engine shafts and an electric power distribution system that includes energy storage. A controller is used to decide when and how energy is moved around the electrified propulsion system, particularly when considering energy conversion between mechanical and electrical forms. Prior work has shown that the electric machines can be used to supply/or extract supplemental power to/from the engine shafts to improve their operability and achieve or enable propulsion efficiency and performance benefits. However, the previous studies did not consider the practical constraints of the electrical machines and energy storage devices that are required for implementing the TEEM system architecture concept. This paper presents an integrated engine and electrical system model that is used to evaluate the electrical system requirements. The model captures the physics of the conceptual, Advanced Geared Turbofan 30,000lbf (AGTF30) engine, which features advanced technologies such as a compact gas turbine and a variable area fan nozzle. For this work, the engine is augmented with electrical system components that allow for the implementation of the TEEM concept. The evaluation presented suggests the potential of the TEEM concept to provide performance benefits for a turbofan engine.

hybrid electric propulsion↗

Phase 1 of the First Solar Small Power System Experiment (experimental System No. 1). Volume 3: Appendix E - N

The design of a solar electric power plant for a small community is reported. Topics covered include: (1) control configurations and interface requirements for the baseline power system; (2) annual small power system output; (3) energy requirements for operation of the collectors and control building; (4) life cycle costs and reliability predictions; (5) thermal conductivities and costs of receiver insulation materials; (6) transient thermal modelling for the baseline receiver/thermal transport system under normal and inclement operating conditions; (7) high temperature use of sodium; (8) shading in a field of parabolic collectors; and (9) buffer storage materials.

Clark, T. B.↗

Compressive Sensing Based Space Flight Instrument Constellation for Measuring Gravitational Microlensing Parallax

In this work, we provide a compressive sensing architecture for implementing on a space based observatory for detecting transient photometric parallax caused by gravitational microlensing events. Compressive sensing (CS) is a simultaneous data acquisition and compression technique, which can greatly reduce on-board resources required for space flight data storage and ground transmission. We simulate microlensing parallax observations using a space observatory constellation, based on CS detectors. Our results show that average CS error is less than 0.5% using 25% Nyquist rate samples. The error at peak magnification time is significantly lower than the error for distinguishing any two microlensing parallax curves at their peak magnification. Thus, CS is an enabling technology for detecting microlensing parallax, without causing any loss in detection accuracy.

compressive sensing↗

Finite Difference Time Marching in the Frequency Domain: A Parabolic Formulation for Aircraft Acoustic Nacelle Design

An explicit finite difference iteration scheme is developed to study harmonic sound propagation in aircraft engine nacelles. To reduce storage requirements for large 3D problems, the time dependent potential form of the acoustic wave equation is used. To insure that the finite difference scheme is both explicit and stable, time is introduced into the Fourier transformed (steady-state) acoustic potential field as a parameter. Under a suitable transformation, the time dependent governing equation in frequency space is simplified to yield a parabolic partial differential equation, which is then marched through time to attain the steady-state solution. The input to the system is the amplitude of an incident harmonic sound source entering a quiescent duct at the input boundary, with standard impedance boundary conditions on the duct walls and duct exit. The introduction of the time parameter eliminates the large matrix storage requirements normally associated with frequency domain solutions, and time marching attains the steady-state quickly enough to make the method favorable when compared to frequency domain methods. For validation, this transient-frequency domain method is applied to sound propagation in a 2D hard wall duct with plug flow.

Baumeister, Kenneth J.↗

Time-Dependent Parabolic Finite Difference Formulation for Harmonic Sound Propagation in a Two-Dimensional Duct with Flow

An explicit finite difference real time iteration scheme is developed to study harmonic sound propagation in aircraft engine nacelles. To reduce storage requirements for future large 3D problems, the time dependent potential form of the acoustic wave equation is used. To insure that the finite difference scheme is both explicit and stable for a harmonic monochromatic sound field, a parabolic (in time) approximation is introduced to reduce the order of the governing equation. The analysis begins with a harmonic sound source radiating into a quiescent duct. This fully explicit iteration method then calculates stepwise in time to obtain the 'steady state' harmonic solutions of the acoustic field. For stability, applications of conventional impedance boundary conditions requires coupling to explicit hyperbolic difference equations at the boundary. The introduction of the time parameter eliminates the large matrix storage requirements normally associated with frequency domain solutions, and time marching attains the steady-state quickly enough to make the method favorable when compared to frequency domain methods. For validation, this transient-frequency domain method is applied to sound propagation in a 2D hard wall duct with plug flow.

Kreider, Kevin L.↗

Finite Difference Time Marching in the Frequency Domain: A Parabolic Formulation for the Convective Wave Equation

An explicit finite difference iteration scheme is developed to study harmonic sound propagation in ducts. To reduce storage requirements for large 3D problems, the time dependent potential form of the acoustic wave equation is used. To insure that the finite difference scheme is both explicit and stable, time is introduced into the Fourier transformed (steady-state) acoustic potential field as a parameter. Under a suitable transformation, the time dependent governing equation in frequency space is simplified to yield a parabolic partial differential equation, which is then marched through time to attain the steady-state solution. The input to the system is the amplitude of an incident harmonic sound source entering a quiescent duct at the input boundary, with standard impedance boundary conditions on the duct walls and duct exit. The introduction of the time parameter eliminates the large matrix storage requirements normally associated with frequency domain solutions, and time marching attains the steady-state quickly enough to make the method favorable when compared to frequency domain methods. For validation, this transient-frequency domain method is applied to sound propagation in a 2D hard wall duct with plug flow.

Baumeister, K. J.↗

Reversion to the mean of the Solar Wind Input to the Magnetosphere

Earth’s magnetosphere responds to solar wind input over time scales ranging from minutes to days. On minute times scales, researchers seek to identify discontinuities in the solar wind that may trigger transient magnetospheric phenomena such as flux transfer events or substorm onsets. On hour time scales, researchers seek to determine the solar wind phenomena that drive the growth phase of geomagnetic substorms and the storage of magnetic flux within the magnetotail. On longer time scales, researchers seek to determine the solar wind features than propel geomagnetic storms through their initial, main, and recovery phases. Researchers must, perforce, rely upon spacecraft located near the L1 libration point for observations of the solar wind input into the magnetosphere over periods ranging from hours to days. Some of the hazards of doing this are well known. Features seen far upstream at locations away from the Sun-Earth line may never arrive at Earth due to structure in the solar wind transverse to the Sun-Earth line. Alternatively, they may arrive at unexpected times due to errors in calculating their orientation and velocity. Other hazards when predicting the magnetospheric response to varying solar wind conditions are less well understood. When observations of large solar wind drivers at spacecraft far upstream and off the Sun-Earth line are used to select events for study, the ‘reversion to the mean’ effect associated with spatial structure and errors in arrival timing for solar wind features at Earth demands that the magnetosphere will actually be subjected to and respond to solar wind drivers with much lower strengths. Consequently, the magnetospheric response must saturate for the highest solar wind drivers.

David Sibeck↗

Transient Convection Due to Imposed Heat Flux: Application to Liquid-Acquisition Devices

A model problem is considered that addresses the effect of heat load from an ambient laboratory environment on the temperature rise of liquid nitrogen inside an enclosure. This model has applications to liquid acquisition devices inside the cryogenic storage tanks used to transport vapor-free propellant to the main engine. We show that heat loads from Q = 0.001 to 10 W, with corresponding Rayleigh numbers from Ra = 109 to 1013, yield a range of unsteady convective states and temperature rise in the liquid. The results show that Q = 1 to 10 W (Ra = 1012 to 1013) yield temperature distributions along the enclosure height that are similar in trend to experimental measurements. Unsteady convection, which shows selfsimilarity in its planforms, is predicted for the range of heat-load conditions. The onset of convection occurs from a free-convection-dominated base flow that becomes unstable against convective instability generated at the bottom of the enclosure while the top of the enclosure is convectively stable. A number of modes are generated with small-scale thermals at the bottom of the enclosure in which the flow selforganizes into two symmetric modes prior to the onset of the propagation of the instability. These symmetric vertical modes transition to asymmetric modes that propagate as a traveling-wave-type motion of convective modes and are representative of the asymptotic convective state of the flow field. Intense vorticity production is created in the core of the flow field due to the fact that there is shear instability between the vertical and horizontal modes. For the higher Rayleigh numbers, 1012 to 1013, there is a transition from a stationary to a nonstationary response time signal of the flow and temperature fields with a mean value that increases with time over various time bands and regions of the enclosure.

Duval, Walter M. B.↗

Analysis and Design of Crew Sleep Station for ISS

This paper details the analysis and design of the Temporary Sleep Station (TeSS) environmental control system for International Space Station (ISS). The TeSS will provide crewmembers with a private and personal space, to accommodate sleeping, donning and doffing of clothing, personal communication and performance of recreational activities. The need for privacy to accommodate these activities requires adequate ventilation inside the TeSS. This study considers whether temperature, carbon dioxide, and humidity within the TeSS remain within crew comfort and safety levels for various expected operating scenarios. Evaluation of these scenarios required the use and integration of various simulation codes. An approach was adapted for this study, whereby results from a particular code were integrated with other codes when necessary. Computational Fluid Dynamics (CFD) methods were used to evaluate the flow field inside the TeSS, from which local gradients for temperature, velocity, and species concentration such as CO (sub 2) could be determined. A model of the TeSS, containing a human, as well as equipment such as a laptop computer, was developed in FLUENT, a finite-volume code. Other factors, such as detailed analysis of the heat transfer through the structure, radiation, and air circulation from the TeSS to the US Laboratory Aisle, where the TeSS is housed, were considered in the model. A complementary model was developed in G189A, a code which has been used by NASA/JSC for environmental control systems analyses since the Apollo program. Boundary conditions were exchanged between the FLUENT and G189A TeSS models. G189A provides human respiration rates to the FLUENT model, while the FLUENT model provides local convective heat transfer coefficients to G189A model. An additional benefit from using an approach with both a systems simulation and CFD model, is the capability to verify the results of each model by comparison to the results of the other model. The G189A and FLUENT models were used to evaluate various ventilation designs for the TeSS over a range of operating conditions with varying crew metabolic load, equipment operating modes, ventilation flow rates, and with the TeSS doors open and closed. Results from the study were instrumental in the optimization of a design for the TeSS ventilation hardware. A special case was considered where failure of the TeSS ventilation system occurred. In this case, a study was conducted in order to determine the time required for the CO (sub 2) concentration inside the TeSS to increase to ISS limit values under transient conditions. A lumped-capacitance code, SINDA-FLUINT was used in this case to provide accurate predictions of the human reaction to the TeSS cabin conditions including core and skin temperatures and body heat storage. A simple two-dimensional CFD model of a crewmember inside the TeSS was developed in FLUENT in order to determine the volume envelope of the respired air from the human, which maintained a minimum velocity profile. This volume was then used in the SINDA-FLUINT model to facilitate the calculations of CO (sub 2) concentrations, dry bulb temperatures and humidity levels inside the TeSS.

Keener, John F.↗

X-ray spectrometer experiment aboard the ISEE-C /Heliocentric/ spacecraft

This experiment is designed to provide continuous coverage of solar flare X-ray bursts and transient cosmic gamma-ray bursts. A proportional counter and a scintillation detector together cover the energy range from 5 to 228 keV with good sensitivity, large dynamic range, and high temporal resolution. This experiment provides data storage capability and good absolute timing so that in conjunction with similar experiments on other spacecraft, accurate source locations can be obtained for cosmic gamma-ray bursts.

Anderson, K. A.↗

Time dependent difference theory for sound propagation in axisymmetric ducts with plug flow

The time dependent governing acoustic-difference equations and boundary conditions are developed and solved for sound propagation in an axisymmetric (cylindrical) hard wall duct with a plug mean flow and spinning acoustic modes. The analysis begins with a harmonic sound source radiating into a quiescent duct. This explicit iteration method then calculates stepwise in real time to obtain the transient as well as the 'steady' state solutions of the acoustic field. The time dependent finite difference analysis has two advantages over the steady state finite difference and finite element techniques: (1)the elimination of large matrix storage requirements, and (2)shorter solution times under most conditions.

Baumeister, K. J.↗

Time dependent difference theory for sound propagation in axisymmetric ducts with plug flow

The time dependent governing/acoustic-difference equations and boundary conditions are developed and solved for sound propagation in an axisymmetric (cylindrical) hard wall duct with a plug mean flow and spinning acoustic modes. The analysis begins with a harmonic sound source radiating into a quiescent duct. This explicit iteration method then calculates stepwise in real time to obtain the transient as well as the 'steady' state solutions of the acoustic field. The time dependent finite difference analysis has two advantages over the steady state finite difference and finite element techniques: (1) the elimination of large matrix storage requirements, and (2) shorter solution times under most conditions.

Baumeister, K. J.↗

Digital phase-locked-loop speed sensor for accuracy improvement in analog speed controls

A digital speed control that can be combined with a proportional analog controller is described. The stability and transient response of the analog controller were retained and combined with the long-term accuracy of a crystal-controlled integral controller. A relatively simple circuit was developed by using phase-locked-loop techniques and total error storage. The integral digital controller will maintain speed control accuracy equal to that of the crystal reference oscillator.

Birchenough, A. G.↗

Study of a fail-safe abort system for an actively cooled hypersonic aircraft: Computer program documentation

The Fail-Safe Abort System TEMPerature Analysis Program, (FASTEMP), user's manual is presented. This program was used to analyze fail-safe abort systems for an actively cooled hypersonic aircraft. FASTEMP analyzes the steady state or transient temperature response of a thermal model defined in rectangular, cylindrical, conical and/or spherical coordinate system. FASTEMP provides the user with a large selection of subroutines for heat transfer calculations. The various modes of heat transfer available from these subroutines are: heat storage, conduction, radiation, heat addition or generation, convection, and fluid flow.

Haas, L. A., Sr.↗