Search NASA⌕ Search

SEARCH · Search NASA

Results for “transition edge detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Development of the microcalorimeter and anticoincidence detector for the Line Emission Mapper x-ray probe

The Line Emission Mapper (LEM) is an x-ray probe mission concept that is designed to provide unprecedented insight into the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. LEM incorporates a light-weight x-ray optic with a large-format microcalorimeter array. The LEM detector utilizes a 14k pixel array of transition-edge sensors (TESs) that will provide <2.5 eV spectral resolution over the energy range 0.2 to 2 keV, along with a field-of-view of 30 arcmin. The microcalorimeter array and readout builds upon the technology developed for the European Space Agency’s (ESA’s) Athena/x-ray Integral Field Unit. Here, we present a detailed overview of the base- line microcalorimeter design, its performance characteristics, including a detailed energy resolution budget and the expected count-rate capability. In addition, we outline the current status and plan for continued technology maturation. Behind the LEM array sits a high-efficiency TES-based anticoincidence (antico) detector that will reject cosmic-ray background events. We will briefly describe the design of the antico and plan for continued development.

47 OTHER INSTRUMENTATION↗

Feedhorn-Coupled Transition-Edge Superconducting Bolometer Arrays for Cosmic Microwave Background Polarimetry

NIST produces large-format, dual-polarization-sensitive detector arrays for a broad range of frequencies (30-1400 GHz). Such arrays enable a host of astrophysical measurements. Detectors optimized for cosmic microwave background observations are monolithic, polarization-sensitive arrays based on feedhorn and planar Nb antenna-coupled transition-edge superconducting (TES) bolometers. Recent designs achieve multiband, polarimetric sensing within each spatial pixel. In this proceeding, we describe our multichroic, feedhorn-coupled design; demonstrate performance at 70-380 GHz; and comment on current developments for implementation of these detector arrays in the advanced Atacama Cosmology Telescope receiver

multichroic↗

A Hot-electron Direct Detector for Radioastronomy

A hot-electron transition-edge superconducting bolometer with adjustable thermal relaxation speed is proposed. The bolometer contacts are made from a superconductor with high critical temperature which blocks the thermal diffusion of hot carriers into the contacts. Thus electron-phonon interaction is the only mechanism for heat removal. The speed of thermal relaxation for hot electrons in a nanometer-size superconducting bolometer with T(sub c) = 100-300 mK is controlled by the elastic electron mean free path l. The relaxation rate behaves as T(sup 4)l at subkelvin temperatures and can be reduced by a factor of 10-100 by decreasing 1. Then an antenna- or wave guide-coupled bolometer with a time constant approx. = 10(exp -3) to 10(exp -4) s will exhibit photon-noise limited performance at millimeter and submillimeter wavelengths. The bolometer will have a figure-of-merit NEPtau = 10(exp -22) - 10(exp -21) W/Hz at 100 mK which is 10(exp 3) to 10(exp 4) times better (ie: smaller) than that of a state-of-the-art bolometer. A tremendous increase in speed and sensitivity will have a significant impact for observational mapping applications.

Karasik, Boris S.↗

Mechanical Design and Development of TES Bolometer Detector Arrays for the Advanced ACTPol Experiment

The next generation Advanced ACTPol (AdvACT) experiment is currently underway and will consist of four Transition Edge Sensor (TES) bolometer arrays, with three operating together, totaling 5800 detectors on the sky. Building on experience gained with the ACTPol detector arrays, AdvACT will utilize various new technologies, including 150 mm detector wafers equipped with multichroic pixels, allowing for a more densely packed focal plane. Each set of detectors includes a feedhorn array of stacked silicon wafers which form a spline pro le leading to each pixel. This is then followed by a waveguide interface plate, detector wafer, back short cavity plate, and backshort cap. Each array is housed in a custom designed structure manufactured from high purity copper and then gold plated. In addition to the detector array assembly, the array package also encloses cryogenic readout electronics. We present the full mechanical design of the AdvACT high frequency (HF) detector array package along with a detailed look at the detector array stack assemblies. This experiment will also make use of extensive hardware and software previously developed for ACT, which will be modi ed to incorporate the new AdvACT instruments. Therefore, we discuss the integration of all AdvACT arrays with pre-existing ACTPol infrastructure.

Advanced ACTPol (AdvACT)↗

Characterization of Si-Membrane TES Bolometer Arrays for the HIRMES Instrument

The High Resolution Mid-Infrared Spectrometer (HIRMES) instrument will fly onboard NASA's airborne Stratospheric Observatory for Infrared Astronomy (SOFIA) in 2019. HIRMES will provide astronomers with a unique observing window (25 122 µm) for exploring the evolution of protoplanetary disks into young solar systems, and the composition of our Solar System. There are two focal plane detector arrays for the instrument: a high-resolution (/ = 100,000) 8x16 detector array with a target noise-equivalent power, NEP 3x10-18 W/Hz; and a low-resolution (/ = 2,000 19,000) 16x64 detector array with a target NEP 2x10-17 W/Hz. The detectors for both of these arrays are superconducting Mo/Au bilayer transition edge sensor (TES) bolometers on thin suspended single-crystal silicon membranes. Here we present our characterization results for the detectors in both arrays, including measurements of thermal conductance with comparison to phonon transport models, saturation power, noise, and array uniformity.

Instrumentation and Photography↗

Design and Fabrication of a Two-Dimensional Superconducting Pop-up Bolometer Array

We have been developing an architecture for producing large format, two dimensional arrays of close-packed bolometers, which will enable submillimeter cameras and spectrometers to obtain images and spectra orders of magnitude faster than present instruments. The low backgrounds achieved in these instruments require very sensitive detectors with NEPs of order 5 x 10(exp -18) W/square root of Hz. Superconducting transition edge sensor bolometers can be close-packed using the Pop-up Detector (PUD) format, and SQUID multiplexers operating at the detector base temperature can be intimately coupled to them. The array unit cell is 8 x 32 pixels, using 32- element detector and multiplexer components. We have fabricated an engineering model array with this technology which features a very compact, modular approach for large format arrays. We report on the production of the 32-element components for the arrays. Planned instruments using this array architecture include the Submillimeter and Far-InfraRed Experiment (SAFIRE) on the SOFIA airborne observatory, the South Pole Imaging Fabry-Perot Interferometer (SPIFI) for the AST/RO observatory, the Millimeter Bolometer Camera for the Atacama Cosmology Telescope (MBC/ACT), and the Redshift (Z) Early Universe Spectrometer (ZEUS j.

Benford, Dominic J.↗

Parameter Comparison for Low-Noise MoAu TES Bolometers

We describe a comparative investigation of the parameters of MoAu-bilayer Transition Edge Sensor (TES) bolometers designed for infrared detectors. A set of devices with variations in geometry were fabricated at the NASA/GSFC detector development facility. These detectors have different bilayer aspect ratios (providing differing normal state resistances and current densities), and have varieties of normal metal regions to study the effects of geometry on noise. These normal metal regions are oriented either parallel to or transverse to the direction of current flow, or both. The lowest noise detectors are found to have normal metal regions oriented transversely. For about a dozen different devices, we have measured a large set of parameters by means of a suite of tests. These include complex impedance measurements to derive time constants; IV curves to determine resistance and power; thermal conductance measurements; noise measurements as a function of device resistance; and &rect resistance vs. temperature measurements .

Benford, D. J.↗

Fabrication of Feedhorn-Coupled Transition Edge Sensor Arrays for Measurement of the Cosmic Microwave Background Polarization

Characterization of the minute cosmic microwave background (CMB) polarization signature requires multi-frequency high-throughput precision instrument systems. We have previously described the detector fabrication of a 40 gigahertz focal plane and now describe the fabrication of a 37-element dual-polarization detector module for measurement of the CMB at 90 gigahertz. The 72-TES (Transition Edge Sensor)-based bolometers in each module are coupled to a niobium-based planar orthomode transducer with integrated band defining filters implemented in microstrip transmission line. A single crystal silicon dielectric substrate serves as microstrip dielectric and as a thermal link between the membrane isolated MoAu TES operating at 150 millikelvins and the heat bath. A short silicon leg between the heat bath and the TES bolometer is designed for ballistic phonon transport and provides improved process control and uniformity of thermal conductance in the presence of phonon scattering on roughened surfaces. Micro-machined structures are used to realize the orthomode transducer backshort, provide out of band signal rejection, and a silicon photonic choke for feedhorn coupling are described. The backshort, choke wafer, and detector wafer are indium bump-bonded to create a single 37-element dual-polarization detector module. Fourteen such hexagonally shaped modules each 80 millimeters in size comprise two focal planes. These, along with the recently delivered 40 gigahertz focal plane, will survey a large fraction of the sky as part of the Johns Hopkins University-led ground-based CLASS (Cosmology Large Angular Scale Surveyor) telescope.

Detectors↗

Extracting the electronic structure of light elements in bulk materials through a Compton scattering method in the readily accessible hard x-ray regime

Here, our Compton profile measurements of Ti and TiH 2 using readily available hard X-ray radiation at 27.5 keV, detected by both a Hitachi Vortex silicon-drift detector and a high-resolution superconducting transition-edge sensor array, are found to be in excellent accord with state-of-the-art density functional theory based calculations. The spherically averaged difference between the Compton profiles of TiH 2 and Ti is well described by an inverted parabola, supporting an itinerant behavior of the electron gas screening the protons in the Ti matrix. Our experimental approach, validated by two different detectors, extends the applicability of Compton scattering technique to the readily accessible hard x-ray regime (below 30 keV). Our study suggests possibilities for experiments at low-flux bending magnet synchrotron beamlines and paves the way for the development of tabletop Compton experiments with x-ray tubes.

36 MATERIALS SCIENCE↗

Multiplexed Readout of Thermal Bolometers with Superconducting Transition Edge Thermometers

History shows that in astronomy, more is better. In the near future, direct detector arrays for the far-infrared and submillimeter will contain hundreds to thousands of elements. A multiplexed readout is necessary for practical implementation of such arrays, and has been developed using SQUIDs. The technology permits a 32 x 32 array of bolometers to be read out using approximately 100 wires rather than the >2000 needed with direct wiring. These bolometer arrays are made by micromachining techniques, using superconducting transition edge sensors as the thermistors. We describe the development of this multiplexed superconducting bolometer array architecture as a step toward bringing about the first astronomically useful arrays of this design. This technology will be used in the Submillimeter and Far Infrared Experiment (SAFIRE) instrument on Stratospheric Observatory for Infrared Astronomy (SOFIA), and is a candidate for a wide variety of other spectroscopic and photometric instruments.

Benford, Dominic J.↗

Design and pre-flight performance of SPIDER 280 GHz receivers

In this work we describe upgrades to the Spider balloon-borne telescope in preparation for its second flight, currently planned for December 2021. The Spider instrument is optimized to search for a primordial B-mode polarization signature in the cosmic microwave background at degree angular scales. During its first flight in 2015, Spider mapped ~10% of the sky at 95 and 150 GHz. The payload for the second Antarctic flight will incorporate three new 280 GHz receivers alongside three refurbished 95- and 150 GHz receivers from Spider's first flight. In this work we discuss the design and characterization of these new receivers, which employ over 1500 feedhorn-coupled transition-edge sensors. We describe pre-flight laboratory measurements of detector properties, and the optical performance of completed receivers. These receivers will map a wide area of the sky at 280 GHz, providing new information on polarized Galactic dust emission that will help to separate it from the cosmological signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A model for excess Johnson noise in superconducting transition-edge sensors

Transition-edge sensors (TESs) are two-dimensional superconducting films utilized as highly sensitive detectors of energy or power. These detectors are voltage biased in the superconducting-normal transition where the film resistance is both finite and a strong function of temperature. Unfortunately, the amount of electrical noise observed in TESs exceeds the predictions of existing noise theories. We describe a possible mechanism for the unexplained excess noise, which we term “mixed-down noise.” The source is Johnson noise, which is mixed down to low frequencies by Josephson oscillations in devices with a nonlinear current–voltage relationship. We derive an expression for the power spectral density of this noise and show that its predictions agree with measured data.

Wessels, Abigail (ORCID:0000000173918339)↗

Progress Towards Improved Analysis of TES X-ray Data Using Principal Component Analysis

The traditional method of applying a digital optimal filter to measure X-ray pulses from transition-edge sensor (TES) devices does not achieve the best energy resolution when the signals have a highly non-linear response to energy, or the noise is non-stationary during the pulse. We present an implementation of a method to analyze X-ray data from TESs, which is based upon principal component analysis (PCA). Our method separates the X-ray signal pulse into orthogonal components that have the largest variance. We typically recover pulse height, arrival time, differences in pulse shape, and the variation of pulse height with detector temperature. These components can then be combined to form a representation of pulse energy. An added value of this method is that by reporting information on more descriptive parameters (as opposed to a single number representing energy), we generate a much more complete picture of the pulse received. Here we report on progress in developing this technique for future implementation on X-ray telescopes. We used an 55Fe source to characterize Mo/Au TESs. On the same dataset, the PCA method recovers a spectral resolution that is better by a factor of two than achievable with digital optimal filters.

Low-temperature detectors A[center dot] Transition↗

Low energy backgrounds and excess noise in a two-channel low-threshold calorimeter

Here, we describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a transition edge sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: “shared” multichannel events with a pulse shape consistent with substrate athermal phonon events and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These “singles” are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.

47 OTHER INSTRUMENTATION↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Scalable Background-Limited Polarization-Sensitive Detectors for mm-wave Applications

We report on the status and development of polarization-sensitive detectors for millimeter-wave applications. The detectors are fabricated on single-crystal silicon, which functions as a low-loss dielectric substrate for the microwave circuitry as well as the supporting membrane for the Transition-Edge Sensor (TES) bolometers. The orthomode transducer (OMT) is realized as a symmetric structure and on-chip filters are employed to define the detection bandwidth. A hybridized integrated enclosure reduces the high-frequency THz mode set that can couple to the TES bolometers. An implementation of the detector architecture at Q-band achieves 90% efficiency in each polarization. The design is scalable in both frequency coverage, 30-300 GHz, and in number of detectors with uniform characteristics. Hence, the detectors are desirable for ground-based or space-borne instruments that require large arrays of efficient background-limited cryogenic detectors.

Millimeter-Wave Detectors↗