Search NASA⌕ Search

SEARCH · Search NASA

Results for “treaties”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Comparison of source-location algorithms for atmospheric samplers

Numerous algorithms have been developed to determine the source characteristics for an atmospheric release, e.g., (Bieringer et al., 2017). This study compares three models that have been applied to the data collected by the International Monitoring System operated by the Comprehensive Nuclear-Test-Ban Treaty Preparatory Commission to estimate source event parameters. Each model uses a different approach to estimate the parameters. A deterministic model uses a possible source region (PSR) approach (Ringbom et al., 2014) that is based on the correlation between predicted and measured sample values. An unnamed model developed at Pacific Northwest National Laboratory (herein called BAYEST) uses a Bayesian formulation (Eslinger et al., 2019; Eslinger et al., 2020; Eslinger and Schrom, 2016). The FREAR model uses a different Bayesian formulation (De Meutter and Hoffman, 2020; De Meutter et al., 2021; Pieter De Meutter, 2021). The performance of the three source-location models is evaluated with 100 synthetic release cases for the single xenon isotope, 133 Xe. The release cases resulted in detections in a fictitious network with 120 noble gas samplers. All three source-location models use the same sampling data. The two Bayesian models yield more accurate location estimates than the deterministic PSR model, with FREAR having slightly better location performance than BAYEST. Samplers with collection periods of 3, 6, 8, 12, and 24-h were used. Results from BAYEST show that location accuracy improves with each reduction in sample collection length. The BAYEST model is slightly better for estimating the start time of the release. The PSR model has about the same spread in start times as the FREAR model, but the PSR results have a better average start time. The Bayesian source-location algorithms give more accurate results than the PSR approach, and provide release magnitude estimates, while the base PSR model does not estimate the release magnitude. This investigation demonstrates that a reasonably dense sampling grid will sometimes yield poor location and time estimates regardless of the model. The poor estimates generally coincide with cases where there is a much larger distance between the release point and the first detecting sampler than the average sampler spacing.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A secure measurement unit for an inspection system used in nuclear arms-control verification

Verification of arms control treaties may require information barriers to protect sensitive data acquired during the verification process. These information barriers are commonly implemented in software, but must store and operate on data that are vulnerable to attack and tampering. Here, we present a new Secure Measurement Unit based on a modified pipeline SAR ADC architecture. The idea is to move the information barrier back into the digitization process so that prohibited data is never created. A prototype 65nm CMOS Secure Measurement Unit (SMU) was tested using U-235, U-238, Co-60, Cs-137 and Am-241 sources. Here, the prototype accurately digitized allowable signals while being immune to side-channel attacks on signals within preset forbidden regions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity of the active neutron coincidence collar response during simulated and experimental fresh fuel assay

Verification of the fissile (and fertile) content in fresh nuclear fuel assemblies is conducted by the IAEA to enforce the Nuclear Non-Proliferation Treaty using the UNCL (Uranium Neutron Collar — Light Water Reactor Fuel). The UNCL uses an uncorrelated AmLi neutron source to interrogate the fuel, producing a signal of coincident fission neutrons (Doubles rate) used to assay 235 U content of the fuel. The cost of producing calibration assemblies and limited availability of diverse commercial assemblies at any one time historically restricted the ability to explore the full parameter space experimentally. Monte Carlo simulations can overcome this, but introduce additional sources of uncertainty. In this work, the sensitivity of simulations and measurements to various parameters is assessed for a reference 1616 PWR assembly of uniform 3.2% enrichment. Uncertainty contributions in this evaluation include: simulated AmLi neutron source spectrum, AmLi neutron emission rate, AmLi anisotropicity, high density polyethylene (HDPE) density, the precise position of the fuel assembly within the detector, and experimentally the statistical uncertainty. The overall total systematic uncertainty estimate for the simulation of the absolute/relative Doubles rates responses are estimated to be approximately 2.0%/1.5%, and for experimental measurements systematic uncertainty reduces to 1.1%. This analysis supports further work using the relative Doubles rates in place of measurements for updating and extending the UNCL analysis methodology as systematic uncertainty is reasonably small.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of 17 N as a time-tagged neutron source for calibration of large antineutrino detectors

Large antineutrino detectors hold the potential for remote nuclear reactor monitoring and discovery, which is of great interest for nonproliferation and treaty verification applications. Correlated-particle calibration sources are especially useful for large-volume designs based on detection of inverse beta-decay events, as the timing information of the coincident particles improves background rejection and event reconstruction. 17 N is a promising calibration source since it emits beta-correlated delayed neutrons and can be produced relatively easily using high-energy neutrons. In this work, we examine the feasibility of 17 N as a time-tagged calibration source for large antineutrino detectors. 17 N was produced using a DT neutron generator from a water sample enriched in 17 O, and the observed production rates were found to be consistent with previous measurements of the 17 O(n,p) 17 N reaction cross-section. As a result, time-tagging of 17 N delayed neutrons is demonstrated via beta-neutron coincidence measurements conducted using a specialized beta detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of neutron dosimetry capabilities with the MC-15 portable multiplicity counter

This work proposes a preliminary neutron dose rate estimation method for a neutron multiplicity detector through measurement- and simulation-based analyses. Uncharacterized neutron-emitting sources may be encountered in situations such as nuclear emergency response, safeguards, and treaty verification. These circumstances may present irradiation risk to personnel conducting field assay, search, and characterization measurements. It is therefore of interest to provide a field neutron dosimetry capability with the existing neutron multiplicity counting (NMC) capabilities. To date, no commercially-available neutron detection systems are capable of both accurate NMC and real-time neutron dosimetry. This work will focus on estimating dose rate using input from a single fielded NMC called the MC-15. The energy-dependent neutron detection efficiency response of the MC-15 was quantified in monoenergetic neutron simulations and evaluated in response to two neutron-emitting sources and to a polyethylene-moderated source. The results were compared to existing neutron dosimeters and established the proof of concept for further investigation of the MC-15 for dose estimation. Measurement results were also replicated in simulations; additional simulations were then conducted to expand upon the limited empirical data. The initial empirical results provided a conversion factor appropriate for use when measuring 252 Cf neutrons that is independent of polyethylene shielding presence and thickness. The simulated data sets were then used to evaluate a fit equation allowing estimation of the neutron dose rate for less restricted geometric configurations and dependent only on the distance between the source and the detector. Additionally, the energy dependence of the efficiency response indicates that further empirical evaluations could provide energy-dependent conversion factors for broader neutron dosimetry capabilities with a wider range of neutron-emitting sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and validation of a software for simulating γ-γ coincidence emission and detection probabilities

Gamma-gamma coincidence spectrometers have the potential to significantly enhance detection sensitivity for ultra-trace radionuclide measurements. The implementation of these spectrometers, however, is limited by the complexity of acquisition hardware, data processing and quantification. This work reports development of a novel radionuclide quantification software for γ-γ coincidence measurements. For any radionuclide, the software parses the Evaluated Nuclear Structure Data File (ENSDF) database, recursively simulating all possible γ-γ coincidence signatures and their respective emission and detection probabilities. Implemented using Python programming language, the software employs several strategies to boost overall computational performance. Since coincidence-based spectrometers are of notable interest in monitoring compliance for the Comprehensive Nuclear-Test-Ban Treaty (CTBT), the software’s execution was tested for 84 CTBT-relevant radionuclides. To date, the software has been experimentally validated for 15 radionuclides using the Advanced Radionuclide Gamma spectrOmeter (ARGO) at Pacific Northwest National Laboratory, USA (PNNL). Notably, the software can be operated in convergence mode, whereby coincidence detection efficiency’s convergence behavior can help avoid unreliable radionuclide activity estimates. With growing number of coincidence spectrometers worldwide, this paper aims to assist the radiation metrology community in developing similar software for their system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Global Nuclear Explosion Discrimination Using a Convolutional Neural Network

Using P-wave seismograms, we trained a seismic source classifier using a Convolutional Neural Network. We trained for three classes: earthquake P-wave, underground nuclear explosion (UNE) P-wave, and noise. With the current absence of nuclear testing by countries that have signed the Comprehensive Test Ban Treaty, high quality seismic data from UNEs is limited. Even with limited training data, our model can accurately characterize most events recorded at regional and teleseismic distances, finding over 95% signals in the validation set. We applied the model on holdout datasets of the North Korean test explosions to evaluate the performance on unique region and station-source pairs, with promising results. Additionally, we tested on the Source Physics Experiment events to investigate the potential for chemical explosions to act as a surrogate for nuclear explosions. We anticipate that machine-learning models like our classifier system can have broad application for other seismic signals including volcanic and non-volcanic tremor, anomalous earthquakes, ice-quakes or landslide-quakes.

58 GEOSCIENCES↗

Remote inspection of adversary-controlled environments

Remotely monitoring the location and enduring presence of valuable items in adversary-controlled environments presents significant challenges. In this article, we demonstrate a monitoring approach that leverages the gigahertz radio-wave scattering and absorption of a room and its contents, including a set of mirrors with random orientations placed inside, to remotely verify the absence of any disturbance over time. Our technique extends to large physical systems the application of physical unclonable functions for integrity protection. Its main applications are scenarios where parties are mutually distrustful and have privacy and security constraints. Examples range from the verification of nuclear arms-control treaties to the securing of currency, artwork, or data centers.

47 OTHER INSTRUMENTATION↗

Quantitative imaging and automated fuel pin identification for passive gamma emission tomography

Compliance of member States to the Treaty on the Non-Proliferation of Nuclear Weapons is monitored through nuclear safeguards. The Passive Gamma Emission Tomography (PGET) system is a novel instrument developed within the framework of the International Atomic Energy Agency (IAEA) project JNT 1510, which included the European Commission, Finland, Hungary and Sweden. The PGET is used for the verification of spent nuclear fuel stored in water pools. Advanced image reconstruction techniques are crucial for obtaining high-quality cross-sectional images of the spent-fuel bundle to allow inspectors of the IAEA to monitor nuclear material and promptly identify its diversion. In this work, we have developed a software suite to accurately reconstruct the spent-fuel cross sectional image, automatically identify present fuel rods, and estimate their activity. Unique image reconstruction challenges are posed by the measurement of spent fuel, due to its high activity and the self-attenuation. While the former is mitigated by detector physical collimation, we implemented a linear forward model to model the detector responses to the fuel rods inside the PGET, to account for the latter. The image reconstruction is performed by solving a regularized linear inverse problem using the fast-iterative shrinkage-thresholding algorithm. We have also implemented the traditional filtered back projection (FBP) method based on the inverse Radon transform for comparison and applied both methods to reconstruct images of simulated mockup fuel assemblies. Higher image resolution and fewer reconstruction artifacts were obtained with the inverse-problem approach, with the mean-square-error reduced by 50%, and the structural-similarity improved by 200%. We then used a convolutional neural network (CNN) to automatically identify the bundle type and extract the pin locations from the images; the estimated activity levels finally being compared with the ground truth. The proposed computational methods accurately estimated the activity levels of the present pins, with an associated uncertainty of approximately 5%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron spectroscopy of plutonium using a handheld detection system

The ability to distinguish multiple forms of plutonium from one another, such as oxide and metal, is paramount in areas of nuclear nonproliferation and international safeguards. In its metal form, plutonium can be readily used in a nuclear weapon, while oxide forms are associated with nuclear reactor fuel. Oxide-based plutonium forms emit neutrons with an energy spectrum that is significantly different from the fission neutrons that are emitted from plutonium metal. Organic scintillation detectors output pulses that are proportional to the neutron energy deposited, and therefore present a means of distinguishing these plutonium forms based on their energy spectra. In this work, metal and oxide forms of plutonium were measured using a handheld detection system based on an organic glass scintillator. Monte Carlo modeling of these experiments was performed to provide insight into the origin of the features in the observed light output spectra. Through analysis of multiple regions of these spectra, in a matter of minutes we were able to unambiguously discriminate oxide and metal plutonium forms from one another and from a plutonium-beryllium neutron source, which was considered for comparison because these sources are commonly used in industrial applications. The ability to discriminate weapons-usable material from nuclear reactor fuel has applications in nuclear treaty verification and safeguards.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Feasibility study of a compact neutron resonance transmission analysis instrument

Neutron Resonance Transmission Analysis (NRTA) uses resonant absorption of neutrons to infer the absolute isotopic composition of a target object, enabling applications in a broad range of fields such as archaeology, enrichment analysis of nuclear fuel, and arms control treaty verification. In the past, NRTA involved large user facilities and complex detector systems. However, recent advances in the intensity of compact neutron sources have made compact neutron imaging designs increasingly feasible. This work describes the Monte Carlo (MC) based design of a compact epithermal NRTA radiographic instrument which uses a moderated, compact deuterium-tritium (DT) neutron source and an epithermal neutron detector. Such an instrument would have a wide range of applications, and would be especially impactful for such scenarios as nuclear inspection and arms control verification exercises, where system complexity and mobility may be of critical importance. The MC simulations presented in this work demonstrate accurate time-of-flight (TOF) reconstructions for transmitted neutron energies, capable of differentiating isotopic compositions of nuclear material with high levels of accuracy. A new generation of miniaturized and increasingly more intense neutron sources will allow this technique to achieve measurements with greater precision and speed, with significant impact on a variety of engineering and societal problems.

47 OTHER INSTRUMENTATION↗

Effects of Desiccation and Freezing on Microbial Ionizing Radiation Survivability: Considerations for Mars Sample Return

Increasingly, national space agencies are expanding their goals to include Mars exploration with sample return. To better protect Earth and its biosphere from potential extraterrestrial sources of contamination, as set forth in the Outer Space Treaty of 1967, international efforts to develop planetary protection measures strive to understand the danger of cross-contamination processes in Mars sample return missions. We aim to better understand the impact of the martian surface on microbial dormancy and survivability. Radiation resistance of microbes is a key parameter in considering survivability of microbes over geologic times on the frigid, arid surface of Mars that is bombarded by solar and galactic cosmic radiation. We tested the influence of desiccation and freezing on the ionizing radiation survival of six model microorganisms: vegetative cells of two bacteria (Deinococcus radiodurans, Escherichia coli) and a strain of budding yeast (Saccharomyces cerevisiae); and vegetative cells and endospores of three Bacillus bacteria (B. subtilis, B. megaterium, B. thuringiensis). Desiccation and freezing greatly increased radiation survival of vegetative polyploid microorganisms when applied separately, and when combined, desiccation and freezing increased radiation survival even more so. Thus, the radiation survival threshold of polyploid D. radiodurans cells can be extended from the already high value of 25 kGy in liquid culture to an astonishing 140 kGy when the cells are both desiccated and frozen. However, such synergistic radioprotective effects of desiccation and freezing were not observed in monogenomic or digenomic Bacillus cells and endospores, which are generally sterilized by 12 kGy. This difference is associated with a critical requirement for survivability under radiation, that is, repair of genome damage caused by radiation. Deinococcus radiodurans and S. cerevisiae accumulate similarly high levels of the Mn antioxidants that are required for extreme radiation resistance, as do endospores, though they greatly exceed spores in radioresistance because they contain multiple identical genome copies, which in D. radiodurans are joined by persistent Holliday junctions. We estimate ionizing radiation survival limits of polyploid DNA-based life-forms to be hundreds of millions of years of background radiation while buried in the martian subsurface. Our findings imply that forward contamination of Mars will essentially be permanent, and backward contamination is a possibility if life ever existed on Mars.

59 BASIC BIOLOGICAL SCIENCES↗

Illuminating the North Korean nuclear explosion test in 2017 using remote infrasound observations

North Korea conducted its sixth underground nuclear explosion test (mb 6.3) on 2017 September 3. The underground explosion produced substantial low-frequency atmospheric waves, which were detected by infrasound arrays located up to a distance of 566 km. These infrasound waves are formed by the conversion of seismic energy to acoustic energy across the lithosphere–atmosphere interface. While infrasound records at regional distances produce estimates of ground motion amplitude over spatially extended regions covering about 26 500 km 2 , 3-D full seismo-acoustic simulations within the lithosphere and atmosphere provide quantitative information about seismo-acoustic energy partitioning. Our results demonstrate the capability of remote infrasound observations combined with 3-D propagation modelling to further develop discrimination methods for underground sources. These results contribute to enhance the confidence of source identification and characterization in nuclear test monitoring research, which is essential for the enforcement of the Comprehensive Nuclear-Test-Ban Treaty.

58 GEOSCIENCES↗

Measurements of radioxenon activities during periods of gaseous release from an advanced gas-cooled reactor

Activities of radioxenon isotopes are reported from an Advanced Gas-cooled Reactor (AGR) during periods of gaseous release. Xenon isotopes are relevant to the monitoring regime of the Comprehensive Nuclear-Test-Ban Treaty (CTBT). These releases may affect detections from the International Monitoring System (IMS) by influencing the radioxenon background. Time series activity plots have been produced from both in-core monitoring and direct measurement at the point of release using a stack monitor system. Ratio plots using both data sets have been produced with results compared with a commonly chosen nuclear explosion “discrimination line.” The reported results improve the understanding of radionuclide emissions from civil nuclear power plants. This work is being performed as part of the Xenon Environmental Nuclide Analysis at Hartlepool (XENAH) collaboration between the Atomic Weapons Establishment (AWE, UK), EDF Energy (UK), Pacific Northwest National Laboratory (PNNL, USA), and the Swedish Defence Research Agency (FOI).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verifying Deep Reductions in the Nuclear Arsenals: Development and Demonstration of a Motion-detection Subsystem for a “Buddy Tag” Using Non-export Controlled Accelerometers

Future nuclear arms-control agreements may place numerical limits on items that are difficult to monitor with national technical means, even when complemented with onsite inspections. Such items could include small objects and mobile assets, such as non-deployed nuclear warheads and mobile missile launchers. Typically, this verification task can be addressed with unique identifiers, but standard tagging techniques may be unacceptable in this case due to host concerns about safety and intrusiveness. First proposed in the late 1980s and partially developed by Sandia National Laboratories in the early 1990s, the “Proximity Tag” or “Buddy Tag” concept seeks to overcome these concerns by separating the tag from the treaty accountable item itself. A buddy tag has two key elements: a tamper-indicating enclosure and a motion-detection system designed to detect illicit movements in a stand-down period. As part of this project, we have built a buddy-tag prototype for demonstration and evaluation purposes. This paper reviews the design choices and functionalities of the tag’s motion-detection subsystem.We pursue a modular approach for the tag’s hardware, built around an Arduino-class microcontroller and a non-export-controlled low-noise accelerometer, and use open-source algorithms for the motion-detection software. Finally, we discuss the results of an extensive experimental campaign involving both indoor and outdoor measurements assessing the performance of the tag under real-world environmental conditions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Ecological information and approaches needed for risk communication dialogs for acute or chronic environmental crises

Scientists, social scientists, risk communicators, and many others are often thrust into a crisis situation where they need to interact with a range of stakeholders, including governmental personnel (tribal, U.S. federal, state, local), local residents, and other publics, as well as other scientists and other risk communicators in situations where information is incomplete and evolving. This paper provides: (1) an overall framework for thinking about communication during crises, from acute to chronic, and local to widespread, (2) a template for the types of ecological information needed to address public and environmental concerns, and (3) examples to illustrate how this information will aid risk communicators. The main goal is providing an approach to the knowledge needed by communicators to address the challenges of protecting ecological resources during an environmental crisis, or for an on-going, chronic environmental issue. To understand the risk to these ecological resources, it is important to identify the type of event, whether it is acute or chronic (or some combination of these), what receptors are at risk, and what stressors are involved (natural, biological, chemical, radiological). For ecological resources, the key information a communicator needs for a crisis is whether any of the following are present: threatened or endangered species, species of special concern, species groups of concern (e.g., neotropical bird migrants, breeding frogs in vernal ponds, rare plant assemblages), unique or rare habitats, species of commercial and recreational interest, and species/habitats of especial interest for medicinal, cultural, or religious activities. Communication among stakeholders is complicated with respect to risk to ecological receptors because of differences in trust, credibility, empathy, perceptions, world view valuation of the resources, and in many cases, a history of misinformation, disinformation, or no information. Exposure of salmon spawning in the Columbia River to hexavalent chromium from the Hanford Site is used as an example of communication challenges with different stakeholders, including Native Americans with Tribal Treaty rights to the land.

54 ENVIRONMENTAL SCIENCES↗