Search NASA⌕ Search

SEARCH · Search NASA

Results for “two-photon processes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Atom Interferometry for Detection of Gravitational Waves: NASA Institute for Advanced Concepts (NIAC) - Phase 1 Final Report

This report presents the results of the 2012-2013 NASA Institute for Advanced Concepts (NIAC) Phase 1 "Atom Interferometry for Detection of Gravitational Waves" project. The origin of this GW (Gravitational Wave) detection concept using atoms can be traced to theoretical work that first appeared in 2008 and also to a satellite mission-focused followup study that was done in 2011. The goal of the current project was to explore both theoretical and technical issues surrounding the implementation of this idea, as well as to begin performing proof-of-concept experiments to validate critical aspects of the proposal.The top level trade space for the detector design is driven by the strategy employed to mitigate laser frequency noise, which, if uncontrolled, can mask GW signatures. One of the advantages of the atom interferometric approach is the possibility of single baseline detection (Fig. 1.1), even in the presence of laser noise. This is enabled by the differential measurement between the two ensembles of atoms, which can result in substantial laser noise suppression. The details of this suppression depend on the atomic physics techniques used to implement the atom interferometry. Specifically, we considered the effect on noise suppression that results from using traditional two-photon Raman transitions (with alkali atoms) and also single-photon transitions (with alkaline earth-like atoms).The interferometers shown in Fig 1.1(b) take advantage of single-photon transitions (as opposed to traditional Raman transitions) because using light pulses from one direction at a time allows for near perfect common-mode cancellation of laser phase noise, even for long baselines. This calls for the use of atomic transitions with an (ideally large) optical energy level difference with a long (greater than 1 second) lifetime, such as high-transitions routinely used for optical atomic clocks in species like Sr, Ca and Yb. Notably, large momentum transfer (LMT) atom optics - and the sensitivity enhancement they confer – can still be realized by simply adding additional pairs of alternating pulses to each beam splitter process. Section 3 reports on the theoretical work we performed to justify this GW detection protocol using single-photon transitions. This approach represents a new method for GW detection using atoms that is distinct from the original proposal from 2008. At the system level, we evaluated three architectures, each of which implements a different solution to the laser frequency noise issue. The first two designs are based on two-photon Raman transitions with Rb atoms. One of these is a three-satellite, multiple baseline design while the other is a two-satellite, single baseline design. The third proposal is a two-satellite, single baseline design that uses single-photon transitions with Sr atoms. These three architectures are described in more detail in Section 2. There are a number of known technical issues that we have started to address using ground-based experiments. These issues include atom technology development needs such as, for example, lower ensemble temperature requirements and large momentum transfer (LMT) atom optics. To this end, we have built a 10-meter scale atom drop tower, where we can perform proof-of-principle demonstrations of the proposed AGIS detector in an environment that permits more than 2.5 seconds of free-fall time. This facility allows for demonstration of atom interferometry with long interrogation time (seconds) and large atom wavepacket

Saif, Babak N.↗

Imaging the magnetic nanowire cross section and magnetic ordering within a suspended 3D artificial spin-ice

Artificial spin-ice systems are patterned arrays of magnetic nanoislands arranged into frustrated geometries and provide insight into the physics of ordering and emergence. The majority of these systems have been realized in two-dimensions, mainly due to the ease of fabrication, but with recent developments in advanced nanolithography, three-dimensional artificial spin ice (ASI) structures have become possible, providing a new paradigm in their study. Such artificially engineered 3D systems provide new opportunities in realizing tunable ground states, new domain wall topologies, monopole propagation, and advanced device concepts, such as magnetic racetrack memory. Direct imaging of 3DASI structures with magnetic force microscopy has thus far been key to probing the physics of these systems but is limited in both the depth of measurement and resolution, ultimately restricting measurement to the uppermost layers of the system. In this work, a method is developed to fabricate 3DASI lattices over an aperture using two-photon lithography, thermal evaporation, and oxygen plasma exposure, allowing the probe of element-specific structural and magnetic information using soft x-ray microscopy with x-ray magnetic circular dichroism (XMCD) as magnetic contrast. The suspended polymer–permalloy lattices are found to be stable under repeated soft x-ray exposure. Analysis of the x-ray absorption signal allows the complex cross section of the magnetic nanowires to be reconstructed and demonstrates a crescent-shaped geometry. Measurement of the XMCD images after the application of an in-plane field suggests a decrease in magnetic moment on the lattice surface due to oxidation, while a measurable signal is retained on sub-lattices below the surface.

36 MATERIALS SCIENCE↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗

Ligand design in lanthanide complexes for luminescence, therapy, and sensing

In this chapter, we explore the research done by the de Bettencourt-Dias group in luminescent lanthanide complexes. The group has isolated ligands that sensitize the luminescence of lanthanide ions, and that bear additional functional groups that impart unique properties to the resulting complexes, such as the ability to generate cytotoxic singlet oxygen, or report on, through changes in emission intensity, viscosity or temperature at the nanoscale. The energy transfer processes are accessed through one-photon excitation or two-photon excitation through the ligand, as well as upconversion. Moreover, the group explored unique coordination chemistry of lanthanides, taking advantage of secondary interactions to isolate outer-sphere complexes of these ions.

Barber, Patrick S.↗

Entangled Photon Spectroscopy

Conspectus The enhanced interest in quantum-related phenomena has provided new opportunities for chemists to push the limits of detection and analysis of chemical processes. As some have called this the second quantum revolution, a time has come to apply the rules learned from previous research in quantum phenomena toward new methods and technologies important to chemists. While there has been great interest recently in quantum information science (QIS), the quest to understand how nonclassical states of light interact with matter has been ongoing for more than two decades. Our entry into this field started around this time with the use of materials to produce nonclassical states of light. Here, the process of multiphoton absorption led to photon-number squeezed states of light, where the photon statistics are sub-Poissonian. In addition to the great interest in generating squeezed states of light, there was also interest in the formation of entangled states of light. While much of the effort is still in foundational physics, there are numerous new avenues as to how quantum entanglement can be applied to spectroscopy, imaging, and sensing. These opportunities could have a large impact on the chemical community for a broad spectrum of applications. Here, we discuss the use of entangled (or quantum) light for spectroscopy as well as applications in microscopy and interferometry. The potential benefits of the use of quantum light are discussed in detail. From the first experiments in porphyrin dendrimer systems by Dr. Dong-Ik Lee in our group to the measurements of the entangled two photon absorption cross sections of biological systems such as flavoproteins, the usefulness of entangled light for spectroscopy has been illustrated. These early measurements led the way to more advanced measurements of the unique characteristics of both entangled light and the entangled photon absorption cross-section, which provides new control knobs for manipulating excited states in molecules. The first reports of fluorescence-induced entangled processes were in organic chromophores where the entangled photon cross-section was measured. These results would later have widespread impact in applications such as entangled two-photon microscopy. From our design, construction and implementation of a quantum entangled photon excited microscope, important imaging capabilities were achieved at an unprecedented low excitation intensity of 10 7 photons/s, which is 6 orders of magnitude lower than the excitation level for the classical two-photon image. New reports have also illustrated an advantage of nonclassical light in Raman imaging as well. From a standpoint of more precise measurements, the use of entangled photons in quantum interferometry may offer new opportunities for chemistry research. Experiments that combine molecular spectroscopy and quantum interferometry, by utilizing the correlations of entangled photons in a Hong–Ou–Mandel (HOM) interferometer, have been carried out. The initial experiment showed that the HOM signal is sensitive to the presence of a resonant organic sample placed in one arm of the interferometer. In addition, parameters such as the dephasing time have been obtained with the opportunity for even more advanced phenomenology in the future.

36 MATERIALS SCIENCE↗

Quantum optical classifier with superexponential speedup

Abstract Classification is a central task in deep learning algorithms. Usually, images are first captured and then processed by a sequence of operations, of which the artificial neuron represents one of the fundamental units. This paradigm requires significant resources that scale (at least) linearly in the image resolution, both in terms of photons and computational operations. Here, we present a quantum optical pattern recognition method for binary classification tasks. It classifies objects without reconstructing their images, using the rate of two-photon coincidences at the output of a Hong-Ou-Mandel interferometer, where both the input and the classifier parameters are encoded into single-photon states. Our method exhibits the behaviour of a classical neuron of unit depth. Once trained, it shows a constant $${{\mathcal{O}}}(1)$$ O ( 1 ) complexity in the number of computational operations and photons required by a single classification. This is a superexponential advantage over a classical artificial neuron.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tracking structural solvent reorganization and recombination dynamics following e – photoabstraction from aqueous I – with femtosecond x-ray spectroscopy and scattering

Here we present a sub-picosecond resolved investigation of the structural solvent reorganization and geminate recombination dynamics following 400 nm two-photon excitation and photodetachment of a valence p electron from the aqueous atomic solute, I–(aq). The measurements utilized time-resolved X-ray Absorption Near Edge Structure (TR-XANES) spectroscopy and X-ray Solution Scattering (TR-XSS) at the Linac Coherent Light Source x-ray free electron laser in a laser pump/x-ray probe experiment. The XANES measurements around the L 1 -edge of the generated nascent iodine atoms (I 0 ) yield an average electron ejection distance from the iodine parent of 7.4 ± 1.5 Å with an excitation yield of about 1/3 of the 0.1M NaI aqueous solution. The kinetic traces of the XANES measurement are in agreement with a purely diffusion-driven geminate iodine–electron recombination model without the need for a long-lived (I 0 :e–) contact pair. Nonequilibrium classical molecular dynamics simulations indicate a delayed response of the caging H 2 O solvent shell and this is supported by the structural analysis of the XSS data: We identify a two-step process exhibiting a 0.1 ps delayed solvent shell reorganization time within the tight H-bond network and a 0.3 ps time constant for the mean iodine–oxygen distance changes. The results indicate that most of the reorganization can be explained classically by a transition from a hydrophilic cavity with a well-ordered first solvation shell (hydrogens pointing toward I–) to an expanded cavity around I 0 with a more random orientation of the H 2 O molecules in a broadened first solvation shell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurements of atoms and metastable species in N 2 and H 2 –N 2 nanosecond pulse plasmas

We report time-resolved, absolute number densities of metastable N 2 (A 3 Σ u + , v = 0, 1) molecules, ground state N 2 and H atoms, and rotational–translational temperature have been measured by tunable diode laser absorption spectroscopy and two-photon absorption laser-induced fluorescence in diffuse N 2 and N 2 –H 2 plasmas during and after a nanosecond pulse discharge burst. Comparison of the measurement results with the kinetic modeling predictions, specifically the significant reduction of the N 2 (A 3 Σ u + ) populations and the rate of N atom generation during the burst, suggests that these two trends are related. The slow N atom decay in the afterglow, on a time scale longer than the discharge burst, demonstrates that the latter trend is not affected by N atom recombination, diffusion to the walls, or convection with the flow. This leads to the conclusion that the energy pooling in collisions of N 2 (A 3 Σ u + ) molecules is a major channel of N 2 dissociation in electric discharges where a significant fraction of the input energy goes to electronic excitation of N 2 . Additional measurements in a 1% H 2 –N 2 mixture demonstrate a further significant reduction of N 2 (A 3 Σ u + , v = 0, 1) populations, due to the rapid quenching by H atoms accumulating in the plasma. Comparison with the modeling predictions suggests that the N 2 (A 3 Σ u + ) molecules may be initially formed in the highly vibrationally excited states. The reduction of the N 2 (A 3 Σ u + ) number density also diminishes the contribution of the energy pooling process into N2 dissociation, thus reducing the N atom number density. The rate of N atom generation during the burst also decreases, due to its strong coupling to N 2 (A 3 Σ u + , v) populations. On the other hand, the rate of H atom generation, produced predominantly by the dissociative quenching of the excited electronic states of N 2 by H 2 , remains about the same during the burst, resulting in a nearly linear rise in the H atom number density. Comparison of the kinetic model predictions with the experimental results suggests that the yield of H atoms during the quenching of the excited electronic state of N 2 by molecular H 2 is significantly less than 100%. The present results quantify the yield of N and H atoms in high-pressure H 2 –N 2 plasmas, which have significant potential for ammonia generation using plasma-assisted catalysis

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multipolariton control in attosecond transient absorption of autoionizing states

Tunable attosecond transient absorption spectroscopy is an ideal tool for studying and manipulating autoionization dynamics in the continuum. We investigate near-resonant two-photon couplings between the bright 3s –1 4p and dark 3s –1 4f autoionizing states of argon that lead to Autler-Townes-like interactions, forming entangled light-matter states or polaritons. We observe that one-photon couplings with intermediate dark states play an important role in this interaction, leading to the formation of multiple polaritonic branches whose energies exhibit avoided crossings as a function of the dressing-laser frequency. Our experimental measurements and theoretical essential-state simulations show good agreement and reveal how the delay, frequency, and intensity of the dressing pulse govern the properties of autoionizing polariton multiplets. Furthermore, these results demonstrate new pathways for quantum control of autoionizing states with optical fields.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quantum beats in two-color photoionization to the spin-orbit split continuum of Ar

We report a study of the quantum beats in two-color photoionization of argon. An attosecond extreme ultraviolet pulse train prepares an electronic wave packet of definite odd parity, with total angular momentum J = 1, targeting the states between 14.0 and 14.5 eV from the ground state. Two-photon ionization of this wave packet with a tunable infrared probe pulse makes the constituent states interfere in both continuum channels, corresponding to the core angular momenta j c = 1/2 and 3/2, respectively. We analyze photoelectron spectrograms as a function of the time delay of the probe pulse and identify oscillations due to several pairs of states through Fourier decomposition. We observe phase differences between the corresponding beat signals in the two spin-orbit split continua. Comparison of theoretical simulations with the experimental measurements allows us to interpret the amplitudes and phases of ionization signals. Furthermore, we express the observed phase differences in terms of the off-diagonal elements of the short-range scattering matrix and the dipole matrix elements to the continuum eigenchannels.

74 ATOMIC AND MOLECULAR PHYSICS↗

Universal control in bosonic systems with weak Kerr nonlinearities

Resonators with weak single-photon self-Kerr nonlinearities can theoretically be used to prepare Fock states in the presence of a loss much larger than their nonlinearities. Two necessary ingredients are large displacements and a two-photon (parametric) drive. Here, in this study, we find that these systems can be controlled to achieve any desired gate operation in a finite-dimensional subspace (whose dimensionality can be chosen at will). Moreover, we show that the two-photon driving requirement can be relaxed and that full controllability is achievable with only one-photon (linear) drives. We make use of both Trotter-Suzuki decompositions and gradient-based optimization to find control pulses for a desired gate, which reduces the computational overhead by using a small blockaded subspace. We also discuss the infidelity arising from input power limitations in realistic settings, as well as from corrections to the rotating-wave approximation. Our universal control protocol opens the possibility for quantum information processing using a wide range of lossy systems with weak nonlinearities.

Yuan, Ming [Univ. of Chicago, IL (United States)] ↗

Astrometry in two-photon interferometry using an Earth rotation fringe scan

Optical interferometers may not require a phase-stable optical link between the stations if instead sources of quantum-mechanically entangled pairs could be provided to them, enabling long baselines. We developed a new variation of this idea, proposing that photons from two different astronomical sources could be interfered at two decoupled stations. Interference products can then be calculated in post-processing or requiring only a slow, classical connection between stations. In this work, we investigated practical feasibility of this approach. We developed a Bayesian analysis method for the earth rotation fringe scanning technique and showed that in the limit of high signal-to-noise ratio it reproduced the results from a simple Fisher matrix analysis. Here we identify candidate stair pairs in the northern hemisphere, where this technique could be applied. With two telescopes with an effective collecting area of ~ 2 m 2 , we could detect fringing and measure the astrometric separation of the sources at ~100 μas precision in a few hours of observations, in agreement with previous estimates.

47 OTHER INSTRUMENTATION↗

Three Photon Excited Image Scanning Microscopy for in-Depth Super-Resolution Studies of Biological Samples

Multiphoton laser scanning microscopy is a powerful tool for deep imaging of thick biological samples. Image scanning microscopy (ISM) has demonstrated significant improvements in the signal-to-noise ratio in confocal laser scanning microscopy, while at the same time improving upon the effectively attainable resolution. Two-photon excitation (2PE), combined with ISM, has been shown to allow for deep tissue imaging with enhanced resolution compared to 2PE microscopy. Three-photon excitation (3PE) has enabled record imaging depth and contrast for multiphoton imaging, due to the superior suppression of out-of-focus signal generation. In this paper, we demonstrate super-resolution 3PE ISM. This is achieved using a single-photon avalanche detector array, and 1040-nm pulses for 3PE of blue fluorescence. This method enables subdiffraction limited resolution imaging of biological samples stained with blue fluorescent markers, such as mouse myocardial and spinal cord tissues stained with 4 ′ , 6 -diamidino-2-phenylindole. Deconvolution improves the resolving power further and allows for imaging with better than λ / 8 resolution with respect to the 3PE wavelength λ . With the ISM pixel reassignment procedure, we demonstrate a resolution enhancement of ∼ 1.6 laterally, compared to the resolution attained using a photomultiplier tube in a non-descanned detection arrangement, and a factor of ∼ 1.8 enhancement in axial resolution. The experimentally measured three-dimensional point spread function volume is shrunk ∼ 4.4 -fold, which is close to the theoretically expected enhancement. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Biphoton spectral quantum interference for information processing and delay metrology

Broadband time-energy entangled photons feature strong temporal correlations with potential for precision delay metrology, but previous work has leveraged only time-of-flight information ultimately limited by the detection jitter and resolution of the time-tagging electronics. Firstly, our work pushes the entanglement-based nonlocal delay metrology from the conventional time-of-flight measurement to a new direction—two-photon interferometry with subpicosecond sensitivity independent of detection resolution. Next, we show the selective sensitivity of frequency-bin encoded Bell states to the sum and difference of biphoton-delays by using a novel reconfigurable setup capable of switching between the Bell states by successively employing single and dual spectral-line pumps.

Seshadri, Suparna↗

Quantum Imaging with X-rays

Quantum imaging encompasses a broad range of methods that exploit the quantum properties of light to capture information about an object. One such approach involves using a two-photon quantum state, where only one photon interacts with the object being imaged while its entangled partner carries spatial or temporal information. To implement this technique, it is necessary to generate specific quantum states of light and detect photons at the single-photon level. While this method has been successfully demonstrated in the visible electromagnetic spectrum, extending it to X-rays has faced significant challenges due to the difficulties in producing a sufficient rate of X-ray photon pairs and detecting them with adequate resolution. Here, we demonstrate record high rates of correlated X-ray photon pairs produced via a spontaneous parametric down-conversion process and we employ these photons to perform quantum correlation imaging of several objects, including a biological sample (E. cardamomum seedpod). Notably, we report an unprecedented detection rate of about 6,300 pairs per hour and the observation of energy anti-correlation for the X-ray photon pairs. We also present a detailed analysis of the properties of the down-converted X-ray photons, as well as a comprehensive study of the correlation imaging formation, including a study of distortions and corrections. These results mark a substantial advancement in X-ray quantum imaging, expanding the possibilities of X-ray quantum optical technologies, and illustrating the pathway towards enhancing biological imaging with reduced radiation doses.

Gofron, Kaz [ORNL] (ORCID:0000000314415736)↗

Equilibria in Strongly Magnetized Pair Plasmas

Positron-electron pair densities for a thermal plasma in the steady-state equilibrium where pair production balances pair annihilation are found as a function of temperature kT / mc(2) approx. 1, source size R and magnetic field strength B. When the plasma is strongly magnetized, B 10(12) G, the important processes are synchrotron radiation, one-photon (magnetic) pair production and two-photon pair annihilation. An analytic solution for the equilibrium pair density, found under certain simplifying assumptions, shows that optically thin equilibria exist only for sufficiently small source sizes.

Harding, A. K.↗

Pair production rates in mildly relativistic, magnetized plasmas

Electron-positron pairs may be produced by either one or two photons in the presence of a strong magnetic field. In magnetized plasmas with temperatures kT approximately sq mc, both of these processes may be important and could be competitive. The rates of one-photon and two-photon pair production by photons with Maxwellian, thermal bremsstrahlung, thermal synchrotron and power law spectra are calculated as a function of temperature or power law index and field strength. This allows a comparison of the two rates and a determination of the conditions under which each process may be a significant source of pairs in astrophysical plasmas. It is found that for photon densities n(gamma) or = 10 to the 25th power/cu cm and magnetic field strengths B or = 10 to the 12th power G, one-photon pair production dominates at kT approximately sq mc for a Maxwellian, at kT approximately 2 sq mc for a thermal bremsstrahlung spectrum, at all temperatures for a thermal synchrotron spectrum, and for power law spectra with indices s approximately 4.

Burns, M. L.↗

Pair production rates in mildly relativistic magnetized plasmas

Electron-positron pairs may be produced by either one or two photons in the presence of a strong magnetic field. In magnetized plasmas with temperatures kT approximately sq mc, both of these processes may be important and could be competitive. The rates of one-photon and two-photon pair production by photons with Maxwellian, thermal bremsstrahlung, thermal synchrotron and power law spectra are calculated as a function of temperature or power law index and field strength. This allows a comparison of the two rates and a determination of the conditions under which each process may be a significant source of pairs in astrophysical plasmas. It is found that for photon densities n(gamma) or = 10 to the 25th power/cu cm and magnetic field strengths B or = 10 to the 12th power G, one-photon pair production dominates at kT approximately sq mc for a Maxwellian, at kT approximately 2 sq mc for a thermal bremsstrahlung spectrum, at all temperatures for a thermal synchrotron spectrum, and for power law spectra with indices s approximately 4.

Burns, M. L.↗