Miniaturization in x ray and gamma ray spectroscopy

The paper presents advances in two new sensor technologies and a miniaturized associated electronics technology which, when combined, can allow for very significant miniaturization and for the reduction of weight and power consumption in x-ray and gamma-ray spectroscopy systems: (1) Mercuric iodide (HgI2) x-ray technology, which allows for the first time the construction of truly portable, high-energy resolution, non-cryogenic x-ray fluorescence (XRF) elemental analyzer systems, with parameters approaching those of laboratory quality cryogenic instruments; (2) the silicon avalanche photodiode (APD), which is a solid-state light sensitive device with internal amplification, capable of uniquely replacing the vacuum photomultiplier tube in scintillation gamma-ray spectrometer applications, and offering substantial improvements in size, ruggedness, low power operation and energy resolution; and (3) miniaturized (hybridized) low noise, low power amplification and processing electronics, which take full advantage of the favorable properties of these new sensors and allow for the design and fabrication of advanced, highly miniaturized x-ray and gamma-ray spectroscopy systems. The paper also presents experimental results and examples of spectrometric systems currently under construction. The directions for future developments are discussed.

Iwanczyk, Jan S.↗

Helium window for shock-tube monochromators

Technique for coupling vacuum ultraviolet monochromator to shock tube to avoid loss of high energy ultraviolet light during quantitative measurements is described. System consists of helium gas window pumping through small aperture in entrance pupil of monochromator. Diagram of equipment and principles of operation are presented.

Thomas, G. M.↗

Particle analyzing method and apparatus

The rapid chemical analysis of particles in aerosols can be accomplished using an apparatus which produces a controlled stream of individual particles from an environment, and another apparatus which vaporizes and ionizes the particles moving in free flight, for analysis by a mass spectrometer. The device for producing the stream of particles includes a capillary tube through which the air with suspended particles moves, a skimmer with a small opening spaced from an end of the capillary tube to receive particles passing through the tube, and a vacuum pump which removes air from between the tube and skimmer and creates an inflow of air and particles through the tube. The particles passing through the skimmer opening can be simultaneously vaporized and ionized while in free flight, by a laser beam of sufficient intensity that is directed across the path of the free flying particles.

Sinha, M. P.↗

Thermal neutron image intensifier tube provides brightly visible radiographic pattern

Vacuum-type neutron image intensifier tube improves image detection in thermal neutron radiographic inspection. This system converts images to an electron image, and with electron acceleration and demagnification between the input target and output screen, produces a bright image viewed through a closed circuit television system.

Berger, H.↗

Temperature variable long path cell for absorption measurements

The design and construction of a long path cell for absorption measurements at temperatures ranging from 215-470 K and at pressures from vacuum to 10 atm are described. The cell consists of three concentric stainless-steel tubes; the innermost tube is 6.5-in. in internal diameter, has a volume of about 47 l, and contains White-type optics, six thermocouples, and a gas input tube; and the outermost tube provides a vacuum Dewar around the inner assembly. The optical design and temperature control system for the long path temperature variable cell are examined. The long path cell is applicable for analyzing temperature and pressure dependence of spectra and reaction rates of gases, and the cell has flow and photolysis capabilities for studying transient species and photochemically initiated reactions. A diagram of the cell is provided.

Shetter, R. E.↗

From Apollo to Artemis: Opening and Processing Lunar Core 73002 for the ANGSA Program

The Apollo mission returned 382 kg of lunar material comprising rock, soil and core samples. Some of these samples were intentionally set aside after their return from the Moon for future study, including samples sealed on the lunar surface, frozen samples and samples stored under Helium. The Apollo Next Generation Sample Analysis (ANGSA) program was established to study thesesamples, in part to help bridge the gap between Apollo and the next generation of lunar science and exploration.Apollo 17 double drive tube core sample 73001/73002 was collected about 50 meters east of Lara Crater from a landslide deposit originating from South Massif. After separating the two halves, the lower drive tube 73001 was immediately sealed in a special vacuum container. Both drive tubes were then placed in an Apollo Lunar Sample Return Container (ALSRC) and returned to Earth under vacuum. Total sample weight and length of 73001/73002 is 1263.0 g and up to 60 cm, with the upper drive 73002 containing 429.7 g and 23 cm of material ( which was then compressed to 18.5 cm during extrusion in the lab). We will present the meticulous methods involved in preparing for, opening and processing lunar core 73002, the upper half of the double drive tube. This includes searching and locating procedures and tools, practicing assembly and extrusion in a mock-up, and finally opening and dissecting the core sample 73002. Challenges (both expected and unexpected) encountered along the way and lessons learned during this project will help pave the way towards improving future lunar sample return missions and advancing insight into the Moon’s history

C. H. Krysher↗

Condensate-removal device for heat exchangers

Device comprises array of perforated tubes manifolded together and connected to a vacuum suction device. Vacuum applied to these tubes pulls mixture of condensate and effluent gas through perforations and along length of tubes to discharge device. Discharge device may be a separator which separates water vapor from effluent air and allows recirculation of both of them.

Trusch, R. B.↗

Apparatus for producing diamond-like carbon flakes

A vacuum arc from a spot at the face of a graphite cathode to a graphite anode produces a beam of carbon ions and atoms. A carbon coating from this beam is deposited on an ion beam sputtered target to produce diamond-like carbon flakes. A graphite tube encloses the cathode, and electrical isolation is provided by an insulating sleeve. The tube forces the vacuum arc spot to be confined to the surface on the outermost end of the cathode. Without the tube the arc spot will wander to the side of the cathode. This spot movement results in low rates of carbon deposition, and the properties of the deposited flakes are more graphite-like than diamond-like.

Banks, Bruce A.↗

Measurement of damping of graphite epoxy materials

Work on a damping measurement test apparatus is discussed. The device is designed to excite tube specimens in a vacuum chamber. Also some experiments were conducted on a tube specimen to confirm previously reported results. A table of data showing the results of forced vibration tests using a half ring and a free-free boundary is given. The main purpose was to study the effect of the frequency resolution on the damping ratio measurements.

Crocker, M. J.↗

Analysis of Volatile Organic Compounds in the Apollo Next Generation Sample Analysis (ANGSA) 73002 Core Sample

Understanding the organic content of lunar regolith was an early priority upon the return of Apollo samples, with amino acids being of special interest because of their importance to life on Earth and their astrobiological relevance. Many initial studies focused on the detection of amino acids in these samples and attempts to determine the origin of those compounds. Although no consensus on the origin of the amino acids was reached in those early studies, more recent work determined that the detected amino acids originated from both terrestrial contamination and meteoritic or cometary in fall to the lunar surface. A majority of the amino acids in the Apollo samples studied originated from precursor molecules, either indigenous to the lunar samples or contaminants, that reacted during the water extraction and acid hydrolysis process for analysis in the laboratory, but the identities of the amino acid precursors still remain poorly understood. Such precursors could include hydrogen cyanide (HCN) and other volatile organic compounds such as amines, carboxylic acids, or aldehydes and ketones. The identities of these compounds, as well as the effects of years of curation on their abundances in lunar regolith samples stored at ambient temperature under nitrogen gas purge, are not clear. The specially curated samples available through the Apollo Next Generation Sample Analysis (ANGSA) program provide a unique opportunity to use state-of- the-art analytical techniques to examine previously unstudied lunar materials. The ANGSA samples include three types of samples: 1) samples stored frozen since <1 month after Earth arrival; 2) samples stored under helium; and 3) a double drive tube collected by Apollo 17 astronauts, with the bottom portion of the drive tube sealed under vacuum on the Moon and never opened. In contrast to the typically curated Apollo samples that have been kept for decades at room temperature under flowing nitrogen purge that may have significantly reduced the abundance of volatiles, the vacuum-sealed and frozen samples may have enhanced preservation of these volatiles. Our initial investigation examines amino acids and their potential volatile precursors, including hydrogen cyanide (HCN), aldehydes, ketones, amines, and mono-carboxylic acids, in a sample from the top portion of the Apollo 17 double drive tube. These results will aid in understanding the lunar abundances of these molecules and will also be compared to future analyses of other drive tube and frozen ANGSA samples.

Elsila, J. E.↗

Experimentation in the low-density plume of a simulated electrothermal thruster for computer code validation

Pressures and flow angles are measured in the plume of a 20 deg half-angle, conical nozzle in vacuum with Pitot tubes and conical probes. The area of measurement in the plume ranges from the nozzle exit plane to 480 mm axially downstream and from the plume centerline to 60 mm radially. The nozzle has an exit-to-throat area ratio of 100:1 and a throat diameter of 3.2 mm. The nozzle flow exhausts to a vacuum of order 10(exp -2) Pa to simulate a resistojet (an electrothermal rocket of less than 1 N of thrust) operating in space. Experimental data are given for flows of nitrogen at 55 and 68 mg/s, stagnation temperatures between 695 and 921 K, and stagnation pressures ranging from 5600 to 7100 Pa. Data are also given for argon at a rate of 68 mg/s, a stagnation temperature of 648 K, and stagnation pressures of 4500, 4750, and 4770 Pa. Measurements in the nitrogen plume are compared with computational results from a direct-simulation Monte Carlo method.

Meissner, Dana L.↗

Thermal Stability of RP-2 for Hydrocarbon Boost Regenerative Cooling

A series of tests were performed in the NASA Glenn Research Centers Heated Tube Facility to study the heat transfer and thermal stability behavior of RP-2 under conditions similar to those found in rocket engine cooling channels. It has long been known that hydrocarbon fuels, such as RP-2, can decompose at high temperature to form deposits (coke) which can adversely impact rocket engine cooling channel performance. The heated tube facility provides a simple means to study these effects. Using resistively heated copper tubes in a vacuum chamber, flowing RP-2 was heated to explore thermal effects at a range of test conditions. Wall temperature (850-1050F) and bulk fluid temperature (300-500F) were varied to define thermal decomposition and stability at each condition. Flow velocity and pressure were fixed at 75 fts and 1000 psia, respectively. Additionally, five different batches of RP-2 were tested at identical conditions to examine any thermal stability differences resulting from batch to batch compositional variation. Among these tests was one with a potential coke reducing additive known as 1,2,3,4-Tetrahydroquinoline (THQ). While copper tubes were used for the majority of tests, two exploratory tests were performed with a copper alloy known as GRCop-42. Each tube was instrumented with 15 thermocouples to examine the temperature profile, and carbon deposition at each thermocouple location was determined post-test in an oxidation furnace. In many tests, intermittent local temperature increases were observed visually and in the thermocouple data. These hot spots did not appear to correspond with a higher carbon deposition.

Kleinhenz, Julie E.↗

Conceptual Feasibility Study of the Hyperloop Vehicle for Next-Generation Transport

The Hyperloop concept is proposed as a faster, cheaper alternative to high-speed rail and traditional short-haul aircraft. It consists of a passenger pod traveling through a tube under light vacuum while being propelled and levitated by a combination of permanent and electro-magnets. The concept addresses NASA's research thrusts for growth in demand, sustainability, and technology convergence for high-speed transport. Hyperloop is a radical departure from other advanced aviation concepts, however it remains an aeronautics concept that tackles the same strategic goals of low-carbon propulsion and ultra-effcient vehicles. System feasibility was investigated by building a multidisciplinary vehicle sizing model that takes into account aerodynamic, thermodynamic, structures, electromagnetic, weight, and mission analyses. The sizing process emphasized the strong coupling between the two largest systems: the tube and the passenger pod. The model was then exercised to examine Hyperloop from a technical and cost perspective. The structural sizing analysis of the travel tube demonstrates potential for signi cant capital cost reductions by considering an underwater route. Examination of varying passenger capacity indicates that the system can be operated with a wide range of passenger loads without significant change in operating expenses. Lastly, a high-level sizing study simulated variations in tube area, pressure, pod speed, and passenger capacity showing that there is a tube pressure that minimizes operating energy usage. The value of this optimal tube pressure is highly sensitive to numerous design details. These combined estimates of energy consumption, passenger throughput, and mission analyses all support Hyperloop as a faster and cheaper alternative to short-haul flights. The tools and expertise used to quantify these results also demonstrate how traditional aerospace design methods can be leveraged to handle the complex and coupled design process. Much of the technology development required for the Hyperloop is shared with next-generation aircraft. Furthermore, the substantial public interest and active commercial development make it an ideal candidate as an aircraft technology driver and test bed.

Hyperloop Vehicle↗

Seal-off assembly permits rapid evacuation of air from containers

Seal-off assembly which permits rapid container evacuation using large diameter tubing has a vacuum valve that permits sealing plate transfer from the vacuum valve stem to the container after evacuation. The sealing plate can be reused repeatedly. This device can repump in case of a small leak without exposing the container to the atmosphere.

Demers, R. R.↗

Traveling-Wave Tubes

The traveling-wave tube (TWT) is a vacuum device invented in the early 1940's used for amplification at microwave frequencies. Amplification is attained by surrendering kinetic energy from an electron beam to a radio frequency (RF) electromagnetic wave. The demand for vacuum devices has been decreased largely by the advent of solid-state devices. However, although solid state devices have replaced vacuum devices in many areas, there are still many applications such as radar, electronic countermeasures and satellite communications, that require operating characteristics such as high power (Watts to Megawatts), high frequency (below 1 GHz to over 100 GHz) and large bandwidth that only vacuum devices can provide. Vacuum devices are also deemed irreplaceable in the music industry where musicians treasure their tube-based amplifiers claiming that the solid-state and digital counterparts could never provide the same "warmth" (3). The term traveling-wave tube includes both fast-wave and slow-wave devices. This article will concentrate on slow-wave devices as the vast majority of TWTs in operation fall into this category.

Kory, Carol L.↗

Tubular sublimatory evaporator heat sink

An evaporative refrigerator or cooler comprising a bundle of spaced, porous walled tubes closed at one of their ends and vented to a vacuum at the other end is disclosed. The tube bundle is surrounded by a water jacket having a hot water inlet distribution manifold and a cooled water outlet through a plenum chamber. Hot water is pumped into the jacket to circulate around the tubes, and when this water meets the vacuum existing inside the tubes, it evaporates thereby cooling the water in the jacket. If cooling proceeds to the point where water penetrating or surrounding all or part of the tubes freezes, operation continues with local sublimation of the ice on the tubes while the circulating water attempts to melt the ice. Both sublimation and evaporation may take place simultaneously in different regions of the device.