Search NASA⌕ Search

SEARCH · Search NASA

Results for “value stacking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

COMPLETE INFRARED SPECTRAL ENERGY DISTRIBUTIONS OF MILLIMETER DETECTED QUASARS AT z > 5

We present Herschel far-infrared (FIR) photometry of 11 quasars at redshift z > 5 that have previously been detected at 1.2 mm. We perform full spectral energy distribution (SED) fits over the wavelength range {lambda}{sub rest} {approx} 0.1-400 {mu}m for those objects with good Herschel detections. These fits reveal the need for an additional FIR component besides the emission from a dusty active galactic nucleus (AGN)-powered torus. This additional FIR component has temperatures of T{sub FIR} {approx} 40-60 K with luminosities of L{sub 8-1000{mu}m} {approx} 10{sup 13} L{sub Sun} (accounting for 25%-60% of the bolometric FIR luminosity). If the FIR dust emission is due to star formation it would suggest star formation rates in excess of 1000 solar masses per year. We show that at long wavelengths ({lambda}{sub rest} {approx}> 50 {mu}m) the contribution of the AGN-powered torus emission is negligible. This explains how previous FIR studies of high-redshift quasars that relied on single-component fits to (ground-based) observations at {lambda}{sub obs} {approx}> 350 {mu}m reached T{sub FIR} and L{sub FIR} values similar to our complete SED fits. Stacking the Herschel data of four individually undetected sources reveals a significant average signal in the PACS bands but not in SPIRE. The average SED of sources with individual Herschel detections shows a striking surplus in near- and mid-infrared (MIR) emission when compared to common AGN templates. The comparison between two average SEDs (sources with and without individual Herschel detections) matched in the UV/optical indicates that for these objects the strength of the MIR emission may correlate with the strength of the FIR emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of Gas, Oil and Wood Pellet Fueled Residential Heating System Emissions Characteristics

This study has measured the emissions from a wide range of heating equipment burning different fuels including several liquid fuel options, utility supplied natural gas and wood pellet resources. The major effort was placed on generating a database for the mass emission rate of fine particulates (PM 2.5) for the various fuel types studied. The fine particulates or PM 2.5 (less than 2.5 microns in size) were measured using a dilution tunnel technique following the method described in US EPA CTM-039. The PM 2.5 emission results are expressed in several units for the benefit of scientists, engineers and administrators. The measurements of gaseous emissions of O{sub 2}, CO{sub 2}, CO, NO{sub x} and SO{sub 2} were made using a combustion analyzer based on electrochemical cells These measurements are presented for each of the residential heating systems tested. This analyzer also provides a steady state efficiency based on stack gas and temperature measurements and these values are included in the report. The gaseous results are within the ranges expected from prior emission studies with the enhancement of expanding these measurements to fuels not available to earlier researchers. Based on measured excess air levels and ultimate analysis of the fuel's chemical composition the gaseous emission results are as expected and fall within the range provided for emission factors contained in the US-EPA AP 42, Emission Factors Volume I, Fifth Edition. Since there were no unexpected findings in these gaseous measurements, the bulk of the report is centered on the emissions of fine particulates, or PM 2.5. The fine particulate (PM 2.5) results for the liquid fuel fired heating systems indicate a very strong linear relationship between the fine particulate emissions and the sulfur content of the liquid fuels being studied. This is illustrated by the plot contained in the first figure on the next page which clearly illustrates the linear relationship between the measured mass of fine particulate per unit of energy, expressed as milligrams per Mega-Joule (mg/MJ) versus the different sulfur contents of four different heating fuels. These were tested in a conventional cast iron boiler equipped with a flame retention head burner. The fuels included a typical ASTM No. 2 fuel oil with sulfur below 0.5 percent (1520 average ppm S), an ASTM No. 2 fuel oil with very high sulfur content (5780 ppm S), low sulfur heating oil (322 ppm S) and an ultra low sulfur diesel fuel (11 ppm S). Three additional oil-fired heating system types were also tested with normal heating fuel, low sulfur and ultralow sulfur fuel. They included an oil-fired warm air furnace of conventional design, a high efficiency condensing warm air furnace, a condensing hydronic boiler and the conventional hydronic boiler as discussed above. The linearity in the results was observed with all of the different oil-fired equipment types (as shown in the second figure on the next page). A linear regression of the data resulted in an Rsquared value of 0.99 indicating that a very good linear relationship exits. This means that as sulfur decreases the PM 2.5 emissions are reduced in a linear manner within the sulfur content range tested. At the ultra low sulfur level (15 ppm S) the amount of PM 2.5 had been reduced dramatically to an average of 0.043 mg/MJ. Three different gas-fired heating systems were tested. These included a conventional in-shot induced draft warm air furnace, an atmospheric fired hydronic boiler and a high efficiency hydronic boiler. The particulate (PM 2.5) measured ranged from 0.011 to 0.036 mg/MJ. depending on the raw material source used in their manufacture. All three stoves tested were fueled with premium (low ash) wood pellets obtained in a single batch to provide for uniformity in the test fuel. Unlike the oil and gas fired systems, the wood pellet stoves had measurable amounts of particulates sized above the 2.5-micron size that defines fine particulates (less than 2.5 microns). The fine particulate emissions rates ranged from 22 to 30 mg/ MJ with an average value of 25 mg/MJ for the three stoves tested.

02 PETROLEUM↗

The Rest-frame Optical (900 nm) Galaxy Luminosity Function at z ∼ 4–7: Abundance Matching Points to Limited Evolution in the M{sub STAR}/M{sub HALO} Ratio at z ≥ 4

We present the first determination of the galaxy luminosity function (LF) at z ∼ 4, 5, 6, and 7, in the rest-frame optical at λ{sub rest}∼900 nm (z′ band). The rest-frame optical light traces the content in low-mass evolved stars (∼stellar mass—M {sub *}), minimizing potential measurement biases for M {sub *}. Moreover, it is less affected by nebular line emission contamination and dust attenuation, is independent of stellar population models, and can be probed up to z ∼ 8 through Spitzer/IRAC. Our analysis leverages the unique full-depth Spitzer/IRAC 3.6–8.0 μm data over the CANDELS/GOODS-N, CANDELS/GOODS-S, and COSMOS/UltraVISTA fields. We find that, at absolute magnitudes where M{sub z{sup ′}} is fainter than ≳−23 mag, M{sub z{sup ′}} linearly correlates with M{sub UV,1600}. At brighter M{sub z{sup ′}}, M{sub UV,1600} presents a turnover, suggesting that the stellar mass-to-light ratio M{sub ∗}/L{sub UV,1600} could be characterized by a very broad range of values at high stellar masses. Median-stacking analyses recover an M{sub ∗}/L{sub z{sup ′}} roughly independent on M{sub z{sup ′}} for M{sub z{sup ′}}≳−23 mag, but exponentially increasing at brighter magnitudes. We find that the evolution of the LF marginally prefers a pure luminosity evolution over a pure density evolution, with the characteristic luminosity decreasing by a factor of ∼5× between z ∼ 4 and z ∼ 7. Direct application of the recovered M{sub ∗}/L{sub z{sup ′}} generates stellar mass functions consistent with average measurements from the literature. Measurements of the stellar-to-halo mass ratio at fixed cumulative number density show that it is roughly constant with redshift for M{sub h}≳10{sup 12}M{sub ⊙}. This is also supported by the fact that the evolution of the LF at 4≲z≲7 can be accounted for by a rigid displacement in luminosity, corresponding to the evolution of the halo mass from abundance matching.

79 ASTRONOMY AND ASTROPHYSICS↗

Further measurements and reassessment of the magnetic-monopole candidate

The data on the 1975 Lexan event are reexamined in a framework that does not depend on the details of a particular track model. Instead, visual measurements of two quantities, photographic evidence, and silver-grain densities measured with an automated microscopic-image dissector are cited. It is shown that throughout the detector stack the particle had a roughly constant value of absolute Z/beta of about 109-114 based on energy deposition at radial distance less than about 0.01 micron. Its energy deposition at radial distance greater than about 20 microns was incompatible with that expected from any known cosmic ray nucleus with Z/beta in this range. A monopole is ruled out, and the three candidates compatible with the data are: (1) a slow, supermassive particle with beta about 0.4, charge about 45e, and mass above 1000-10,000 amu; (2) a fast antinucleus with Z/beta about -109 to -114 and absolute Z between 76 and 96; and (3) a very fast nucleus with Z about 110-114 and beta above about 0.99.

Price, P. B.↗

Spectral gain profile of a multi-stack terahertz quantum cascade laser

The spectral gain of a multi-stack terahertz quantum cascade laser, composed of three active regions with emission frequencies centered at 2.3, 2.7, and 3.0 THz, is studied as a function of driving current and temperature using terahertz time-domain spectroscopy. The optical gain associated with the particular quantum cascade stacks clamps at different driving currents and saturates to different values. We attribute these observations to varying pumping efficiencies of the respective upper laser states and to frequency dependent optical losses. The multi-stack active region exhibits a spectral gain full width at half-maximum of 1.1 THz. Bandwidth and spectral position of the measured gain match with the broadband laser emission. As the laser action ceases with increasing operating temperature, the gain at the dominant lasing frequency of 2.65 THz degrades sharply.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stacked filters: learning to filter by structure

We present Stacked Filters, a new probabilistic filter which is fast and robust similar to query-agnostic filters (such as Bloom and Cuckoo filters), and at the same time brings low false positive rates and sizes similar to classifier-based filters (such as Learned Filters). The core idea is that Stacked Filters incorporate workload knowledge about frequently queried non-existing values. Instead of learning, they structurally incorporate that knowledge using hashing and several sequenced filter layers, indexing both data and frequent negatives. Stacked Filters can also gather workload knowledge on-the-fly and adaptively build the filter. We show experimentally that for a given memory budget, Stacked Filters achieve end-to-end query throughput up to 130x better than the best alternative for a workload, either query-agnostic or classifier-based filters, and depending on where data is (SSD or HDD).

Computer Science↗

Flow in a differentially rotated cylindrical drop at moderate Reynolds number

Galerkin finite-element approximations are combined with computer-implemented perturbation methods for tracking families of solutions to calculate the steady axisymmetric flows in a differentially rotated cylindrical drop as a function of Reynolds number Re, drop aspect ratio and the rotation ratio between the two end disks. The flows for Reynolds numbers below 100 are primarily viscous and reasonably described by an asymptotic analysis. When the disks are exactly counter-rotated, multiple steady flows are calculated that bifurcate to higher values of Re from the expected solution with two identical secondary cells stacked symmetrically about the axial midplane. The new flows have two cells of different size and are stable beyond the critical value Re sub c. The slope of the locus of Re sub c for drops with aspect ratio up to 3 disagrees with the result for two disks of infinite radius computed assuming the similarity form of the velocity field. Changing the rotation ratio for exact counter-rotation ruptures the junction of the multiple flow fields into two separated flow families.

Harriott, G. M.↗

Investigating realistic anode off-gas combustion in SOFC/ICE hybrid systems: mini review and experimental evaluation

Solid oxide fuel cells (SOFCs) have been deployed in hybrid decentralized energy systems, in which they are directly coupled to internal combustion engines (ICEs). Prior research indicated that the anode tailgas exiting the SOFC stack should be additionally exploited due to its high energy value, with typical ICE operation favoring hybridization due to matching thermodynamic conditions during operation. Consequently, extensive research has been performed, in which engines are positioned downstream the SOFC subsystem, operating in several modes of combustion, with the most prevalent being homogeneous compression ignition (HCCI) and spark ignition (SI). Experiments were performed in a 3-cylinder ICE operating in the latter modus operandi, where the anode tailgas was assimilated by mixing syngas (H 2 : 33.9%, CO: 15.6%, CO 2 : 50.5%) with three different water vapor flowrates in the engine’s intake. While increased vapor content significantly undermined engine performance, brake thermal efficiency (BTE) surpassed 34% in the best case scenario, which outperformed the majority of engines operating under similar operating conditions, as determined from the conducted literature review. Nevertheless, the best performing application was identified operating under HCCI, in which diesel reformates assimilating SOFC anode tailgas, fueled a heavy duty ICE (17:1), and gross indicated thermal efficiency ([Formula: see text]) of 48.8% was achieved, with the same engine exhibiting identical performance when operating in reactivity-controlled compression ignition (RCCI). Overall, emissions in terms of NO x and CO were minimal, especially in SI engines, while unburned hydrocarbons (UHC) were non-existent due to the absence of hydrocarbons in the assessed reformates.

Engineering↗

RECENT ADVANCES IN HIGH TEMPERATURE ELECTROLYSIS AT IDAHO NATIONAL LABORATORY: STACK TESTS

High temperature steam electrolysis is a promising technology for efficient sustainable large-scale hydrogen production. Solid oxide electrolysis cells (SOECs) are able to utilize high temperature heat and electric power from advanced high-temperature nuclear reactors or renewable sources to generate carbon-free hydrogen at large scale. However, long term durability of SOECs needs to be improved significantly before commercialization of this technology. A degradation rate of 1%/khr or lower is proposed as a threshold value for commercialization of this technology. Solid oxide electrolysis stack tests have been conducted at Idaho National Laboratory to demonstrate recent improvements in long-term durability of SOECs. Electrolytesupported and electrode-supported SOEC stacks were provided by Ceramatec Inc., Materials and Systems Research Inc. (MSRI), and Saint Gobain Advanced Materials (St. Gobain), respectively for these tests. Long-term durability tests were generally operated for a duration of 1000 hours or more. Stack tests based on technology developed at Ceramatec and MSRI have shown significant improvement in durability in the electrolysis mode. Long-term degradation rates of 3.2%/khr and 4.6%/khr were observed for MSRI and Ceramatec stacks, respectively. One recent Ceramatec stack even showed negative degradation (performance improvement) over 1900 hours of operation. A three-cell short stack provided by St. Gobain, however, showed rapid degradation in the electrolysis mode. Improvements on electrode materials, interconnect coatings, and electrolyteelectrode interface microstructures contribute to better durability of SOEC stacks.

08 HYDROGEN↗

Improved Durability of SOEC Stacks for High Temperature Electrolysis

High temperature steam electrolysis is a promising technology for efficient and sustainable large-scale hydrogen production. Solid oxide electrolysis cells (SOECs) are able to utilize high temperature heat and electric power from advanced high-temperature nuclear reactors or renewable sources to generate carbon-free hydrogen at large scale. However, long term durability of SOECs needs to be improved significantly before commercialization of this technology can be realized. A degradation rate of 1%/khr or lower is proposed as a threshold value for commercialization of this technology. Solid oxide electrolysis stack tests have been conducted at Idaho National Laboratory to demonstrate recent improvements in long-term durability of SOECs. Electrolyte-supported and electrode-supported SOEC stacks were provided by Ceramatec Inc. and Materials and Systems Research Inc. (MSRI), respectively, for these tests. Long-term durability tests were generally operated for a duration of 1000 hours or more. Stack tests based on technologies developed at Ceramatec and MSRI have shown significant improvement in durability in the electrolysis mode. Long-term degradation rates of 3.2%/khr and 4.6%/khr were observed for MSRI and Ceramatec stacks, espectively. One recent Ceramatec stack even showed negative degradation (performance improvement) over 1900 hours of operation. Optimization of electrode materials, interconnect coatings, and electrolyte-electrode interface microstructures contribute to better durability of SOEC stacks.

08 HYDROGEN↗

Frequency domain analysis of errors in cross-correlations of ambient seismic noise

We analyse random errors (variances) in cross-correlations of ambient seismic noise in the frequency domain, which differ from previous time domain methods. Extending previous theoretical results on ensemble averaged cross-spectrum, we estimate confidence interval of stacked cross-spectrum of finite amount of data at each frequency using non-overlapping windows with fixed length. The extended theory also connects amplitude and phase variances with the variance of each complex spectrum value. Analysis of synthetic stationary ambient noise is used to estimate the confidence interval of stacked cross-spectrum obtained with different length of noise data corresponding to different number of evenly spaced windows of the same duration. This method allows estimating Signal/Noise Ratio (SNR) of noise cross-correlation in the frequency domain, without specifying filter bandwidth or signal/noise windows that are needed for time domain SNR estimations. Based on synthetic ambient noise data, we also compare the probability distributions, causal part amplitude and SNR of stacked cross-spectrum function using one-bit normalization or pre-whitening with those obtained without these pre-processing steps. Natural continuous noise records contain both ambient noise and small earthquakes that are inseparable from the noise with the existing pre-processing steps. Using probability distributions of random cross-spectrum values based on the theoretical results provides an effective way to exclude such small earthquakes, and additional data segments (outliers) contaminated by signals of different statistics (e.g. rain, cultural noise), from continuous noise waveforms. This technique is applied to constrain values and uncertainties of amplitude and phase velocity of stacked noise cross-spectrum at different frequencies, using data from southern California at both regional scale (~35 km) and dense linear array (~20 m) across the plate-boundary faults. A block bootstrap resampling method is used to account for temporal correlation of noise cross-spectrum at low frequencies (0.05–0.2 Hz) near the ocean microseismic peaks.

58 GEOSCIENCES↗

The Effect of a Mainshock on the Size Distribution of the Aftershocks

A systematic decay of the aftershock rate over time is one of the most fundamental empirical laws in Earth science. However, the equally fundamental effect of a mainshock on the size distribution of subsequent earthquakes has still not been quantified today and is therefore not used in earthquake hazard assessment. We apply a stacking approach to well-recorded earthquake sequences to extract this effect. Immediately after a mainshock, the mean size distribution of events, or b value, increases by 20–30%, considerably decreasing the chance of subsequent larger events. Here, this increase is strongest in the immediate vicinity of the mainshock, decreasing rapidly with distance but only gradually over time. We present a model that explains these observations as a consequence of the stress changes in the surrounding area caused by the mainshocks slip. Our results have substantial implications for how seismic risk during earthquake sequences is assessed.

58 GEOSCIENCES↗

Anomalous Hall effect in ZrTe 5

Research in topological matter has expanded to include the Dirac and Weyl semimetals which feature three-dimensional Dirac states protected by symmetry. Zirconium pentatelluride has been of recent interest as a potential Dirac or Weyl semimetal material. Here, we report the results of experiments performed by in situ three-dimensional double-axis rotation to extract the full 4π solid angular dependence of the transport properties. A clear anomalous Hall effect is detected in every sample studied, with no magnetic ordering observed in the system to the experimental sensitivity of torque magnetometry. Large anomalous Hall signals develop when the magnetic field is rotated in the plane of the stacked quasi-two-dimensional layers, with the values vanishing above about 60 K, where the negative longitudinal magnetoresistance also disappears. Finally, this suggests a close relation in their origins, which we attribute to the Berry curvature generated by the Weyl nodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE HST/ACS+WFC3 SURVEY FOR LYMAN LIMIT SYSTEMS. II. SCIENCE

We present the first science results from our Hubble Space Telescope survey for Lyman limit absorption systems (LLS) using the low dispersion spectroscopic modes of the Advanced Camera for Surveys and the Wide Field Camera 3. Through an analysis of 71 quasars, we determine the incidence frequency of LLS per unit redshift and per unit path length, l(z) and l(X), respectively, over the redshift range 1 < z < 2.6, and find a weighted mean of l(X) =0.29 {+-} 0.05 for 2.0 < z < 2.5 through a joint analysis of our sample and that of Ribaudo et al. Through stacked spectrum analysis, we determine a median (mean) value of the mean free path to ionizing radiation at z = 2.4 of {lambda}{sup 912}{sub mfp} = 243(252) h {sup -1}{sub 72} Mpc, with an error on the mean value of {+-}43 h {sup -1}{sub 72} Mpc. We also re-evaluate the estimates of {lambda}{sup 912}{sub mfp} from Prochaska et al. and place constraints on the evolution of {lambda}{sup 912}{sub mfp} with redshift, including an estimate of the ''breakthrough'' redshift of z = 1.6. Consistent with results at higher z, we find that a significant fraction of the opacity for absorption of ionizing photons comes from systems with N{sub H{sub I}} {<=}10{sup 17.5} cm{sup -2} with a value for the total Lyman opacity of {tau}{sup Lyman}{sub eff} = 0.40 {+-} 0.15. Finally, we determine that at minimum, a 5-parameter (4 power law) model is needed to describe the column density distribution function f(N{sub H{sub I}}, X) at z {approx} 2.4, find that f(N{sub H{sub I}}, X) undergoes no significant change in shape between z {approx} 2.4 and z {approx} 3.7, and provide our best fit model for f(N{sub H{sub I}}, X).

79 ASTRONOMY AND ASTROPHYSICS↗

Negative Capacitance MgZnO-Channel Thin-Film Transistor With Ferroelectric NiMgZnO in the Gate Stack

We demonstrate the negative capacitance thin-film transistor (NC-TFT) on glass substrate using the multifunctional MgZnO (MZO). The Mg 0.03 Zn 0.97 O semiconductor layer acts as the TFT channel for stable operation while the Ni-doped MZO, i.e. Ni 0.02 Mg 0.15 Zn 0.83 O (NMZO) serves as the ferroelectric layer in the NMZO/SiO 2 stacking gate dielectric structure. The subthreshold swing (SS) value is significantly reduced over the reference TFT without ferroelectric layer. The minimum SS value of the NC-TFT reaches 52 mV/dec while the on/off ratio of drain current ID reaches 10 9 .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effects of regenerator geometry on pulse tube refrigerator performance

This paper gives results of the cooling performance of a double-inlet pulse tube refrigerator using various regenerators. The same pulse tube was used for all the experiments and measured 4.76 mm in diameter and 46.2 mm in length. A commercial linear compressor with a swept volume of 4 cm3 was used in these experiments. The operating conditions were held constant at a mean pressure of 2.0 MPa and a frequency of 54 Hz. Using finite difference software called REGEN3.1, developed at NIST, and recent experiment results, we optimized a series of regenerators based on dimensions, materials and screen packing. The values used for calculating the thermal conduction through stacked screens by REGEN3.1 were based on recent experimental results from NIST. The regenerator tubes were designed using 316 stainless steel and titanium materials. The regenerator matrices investigated were 400-mesh and 500-mesh stainless steel screen. The valve settings for both orifices were adjusted to minimize the no-load temperature for all regenerators. A cooling capacity curve from 0 to 3 W was also determined. The performance of the pulse tube refrigerator using the different regenerators is discussed. The experimental results from the various regenerators are evaluated and compared with their corresponding numerically calculated coefficient of performance (COP) and regenerator design as determined by REGEN3.1.

NASA Discipline Life Sciences Technologies↗

Metal stack templates for suppressing secondary grains in sca1n

A metal stack for templating the growth of AlN and ScAlN films is disclosed. The metal stack comprises one, two, or three layers of metal, each of which is compatible with CMOS post-processing. The metal stack provides a template that promotes the growth of highly textured c-axis {002} AlN and ScAlN films. The metal stacks include one or more metal layers with each metal layer having either a hexagonal {002} orientation or a cubic {111} orientation. If the metal stack includes two or more metal layers, the layers can alternate between hexagonal {002} and cubic {111} orientations. The use of ScAlN results in a higher piezoelectric constant compared to that of AlN for ScAlN alloys up to approximately 44% Sc. The disclosed metal stacks resulted in ScAlN films having XRD FWHM values of less than approximately 1.1° while significantly reducing the formation of secondary grains in the ScAlN films.

Esteves, Giovanni↗

SAMZ: Satellite-Derived Management Zones

The term "satellite-derived management zones" (SAMZ) denotes agricultural management zones that are subdivisions of large fields and that are derived from images of the fields acquired by instruments aboard Earth orbiting satellites during approximately the past 15 years. "SAMZ" also denotes the methodology and the software that implements the methodology for creating such zones. The SAMZ approach is one of several products of continuing efforts to realize a concept of precision agriculture, which involves optimal variations in seeding, in application of chemicals, and in irrigation, plus decisions to farm or not to farm certain portions of fields, all in an effort to maximize profitability in view of spatial and temporal variations in the growth and health of crops and in the chemical and physical conditions of soils. As used here, "management zone" signifies, more precisely, a subdivision of a field within which the crop production behavior is regarded as homogeneous. From the perspective of precision agriculture, management zones are the smallest subdivisions between which the seeding, application of chemicals, and other management parameters are to be varied. In the SAMZ approach, the main sources of data are the archives of satellite imagery that have been collected over the years for diverse purposes. One of the main advantages afforded by the SAMZ approach is that the data in these archives can be reused for purposes of precision agriculture at low cost. De facto, these archives contain information on all sources of variability within a field, including weather, crop types, crop management, soil types, and water drainage patterns. The SAMZ methodology involves the establishment of a Web-based interface based on an algorithm that generates management zones automatically and quickly from archival satellite image data in response to requests from farmers. A farmer can make a request by either uploading data describing a field boundary to the Web site or else drawing the boundary on a reference image. Hence, a farmer can start to engage in precision farming shortly after gaining access to the Web site, without need for incurring the high costs of conventional precision-agriculture data-collection practices that include collecting soil samples, mapping electrical conductivity of soil, and compiling multi-year crop-yield data. Given the boundary of a field, a SAMZ server computes the zones within the field in a three-stage process. In the first stage, a vector-valued image of the field is constructed by assembling, from the archives, the equivalent of a stack of the available images of the field (see figure). In the second stage, the vector-valued image is analyzed by use of a wavelet transform that detects spatial variations considered significant for precision farming while suppressing small-scale heterogeneities that are regarded as insignificant. In the third stage, a segmentation algorithm assembles the zones from smaller regions that have been identified in the wavelet analysis.

Source record↗