SU-E-J-124: FDG PET Metrics Analysis in the Context of An Adaptive PET Protocol for Node Positive Gynecologic Cancer Patients

Purpose: To compare PET extracted metrics and investigate the role of a gradient-based PET segmentation tool, PET Edge (MIM Software Inc., Cleveland, OH), in the context of an adaptive PET protocol for node positive gynecologic cancer patients. Methods: An IRB approved protocol enrolled women with gynecological, PET visible malignancies. A PET-CT was obtained for treatment planning prescribed to 45–50.4Gy with a 55– 70Gy boost to the PET positive nodes. An intra-treatment PET-CT was obtained between 30–36Gy, and all volumes re-contoured. Standard uptake values (SUVmax, SUVmean, SUVmedian) and GTV volumes were extracted from the clinician contoured GTVs on the pre- and intra-treament PET-CT for primaries and nodes and compared with a two tailed Wilcoxon signed-rank test. The differences between primary and node GTV volumes contoured in the treatment planning system and those volumes generated using PET Edge were also investigated. Bland-Altman plots were used to describe significant differences between the two contouring methods. Results: Thirteen women were enrolled in this study. The median baseline/intra-treatment primary (SUVmax, mean, median) were (30.5, 9.09, 7.83)/( 16.6, 4.35, 3.74), and nodes were (20.1, 4.64, 3.93)/( 6.78, 3.13, 3.26). The p values were all < 0.001. The clinical contours were all larger than the PET Edge generated ones, with mean difference of +20.6 ml for primary, and +23.5 ml for nodes. The Bland-Altman revealed changes between clinician/PET Edge contours to be mostly within the margins of the coefficient of variability. However, there was a proportional trend, i.e. the larger the GTV, the larger the clinical contours as compared to PET Edge contours. Conclusion: Primary and node SUV values taken from the intratreament PET-CT can be used to assess the disease response and to design an adaptive plan. The PET Edge tool can streamline the contouring process and lead to smaller, less user-dependent contours.

60 APPLIED LIFE SCIENCES↗

SU-E-J-252: Reproducibility of Radiogenomic Image Features: Comparison of Two Semi-Automated Segmentation Methods

Purpose: Objective and reliable quantification of imaging phenotype is an essential part of radiogenomic studies. We compared the reproducibility of two semi-automatic segmentation methods for quantitative image phenotyping in magnetic resonance imaging (MRI) of glioblastoma multiforme (GBM). Methods: MRI examinations with T1 post-gadolinium and FLAIR sequences of 10 GBM patients were downloaded from the Cancer Image Archive site. Two semi-automatic segmentation tools with different algorithms (deformable model and grow cut method) were used to segment contrast enhancement, necrosis and edema regions by two independent observers. A total of 21 imaging features consisting of area and edge groups were extracted automatically from the segmented tumor. The inter-observer variability and coefficient of variation (COV) were calculated to evaluate the reproducibility. Results: Inter-observer correlations and coefficient of variation of imaging features with the deformable model ranged from 0.953 to 0.999 and 2.1% to 9.2%, respectively, and the grow cut method ranged from 0.799 to 0.976 and 3.5% to 26.6%, respectively. Coefficient of variation for especially important features which were previously reported as predictive of patient survival were: 3.4% with deformable model and 7.4% with grow cut method for the proportion of contrast enhanced tumor region; 5.5% with deformable model and 25.7% with grow cut method for the proportion of necrosis; and 2.1% with deformable model and 4.4% with grow cut method for edge sharpness of tumor on CE-T1W1. Conclusion: Comparison of two semi-automated tumor segmentation techniques shows reliable image feature extraction for radiogenomic analysis of GBM patients with multiparametric Brain MRI.

60 APPLIED LIFE SCIENCES↗

Development of a two-line OH-laser-induced fluorescence thermometry diagnostics strategy for gas-phase temperature measurements in engines

This study aims at optimizing two-line OH thermometry strategies for in-cylinder measurement in internal combustion engines. Various aspects are investigated experimentally, such as the selection of suitable OH lines and the possibility of using a single calibration coefficient for variable mixture composition, temperature, and pressure conditions. Two kinds of experimental systems have been investigated. First, a laminar methane-air burner flame at atmospheric pressure, whose stability allowed the determination of OH-laser-induced fluorescence (LIF) intensity ratios from nonsimultaneous imaging. The temperature distribution in the flame is presented for OH-transition pairs with various temperature sensitivities. The burner flame was studied for equivalence ratios from {phi}=0.93 to 1.30 in order to check for the stability of calibration over various flame conditions. Additionally, OH LIF images were acquired in an optical engine for the chosen OH transitions yielding data about the effect of pressure on OH LIF signals under realistic experimental conditions.

42 ENGINEERING↗

4D spatiotemporal evolution of liquid spray using kilohertz-rate x-ray computed tomography

Four-dimensional (x, y, z, t) x-ray computed tomography was shown in an optically complex spray using an imaging system consisting of three x-ray sources and three high-speed detectors. The x-ray sources consisted of high-flux rotating anode x-ray tube sources that illuminated the spray from three lines of sight. The absorption along each absorption path was collected using a CsI phosphor plate and imaged by a high-speed intensified CMOS camera at 20 kHz. The radiographs were converted to a quantitative equivalent path length (EPL) of liquid using a variable attenuation coefficient to account for beam hardening. Moreover, the EPL data were then reconstructed using the algebraic reconstruction technique into high-speed time sequences of the threedimensional liquid mass distribution.

47 OTHER INSTRUMENTATION↗

Image Quality Characteristics of Handheld Display Devices for Medical Imaging

Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2x10 -5 mm 2 at 1 mm -1 , while handheld displays have values lower than 3.7x10 -6 mm 2 . Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices.

47 OTHER INSTRUMENTATION↗

STATISTICAL DECOUPLING OF A LAGRANGIAN FLUID PARCEL IN NEWTONIAN COSMOLOGY

The Lagrangian dynamics of a single fluid element within a self-gravitational matter field is intrinsically non-local due to the presence of the tidal force. This complicates the theoretical investigation of the nonlinear evolution of various cosmic objects, e.g., dark matter halos, in the context of Lagrangian fluid dynamics, since fluid parcels with given initial density and shape may evolve differently depending on their environments. In this paper, we provide a statistical solution that could decouple this environmental dependence. After deriving the evolution equation for the probability distribution of the matter field, our method produces a set of closed ordinary differential equations whose solution is uniquely determined by the initial condition of the fluid element. Mathematically, it corresponds to the projected characteristic curve of the transport equation of the density-weighted probability density function (ρPDF). Consequently it is guaranteed that the one-point ρPDF would be preserved by evolving these local, yet nonlinear, curves with the same set of initial data as the real system. Physically, these trajectories describe the mean evolution averaged over all environments by substituting the tidal tensor with its conditional average. For Gaussian distributed dynamical variables, this mean tidal tensor is simply proportional to the velocity shear tensor, and the dynamical system would recover the prediction of the Zel’dovich approximation (ZA) with the further assumption of the linearized continuity equation. For a weakly non-Gaussian field, the averaged tidal tensor could be expanded perturbatively as a function of all relevant dynamical variables whose coefficients are determined by the statistics of the field.

79 ASTRONOMY AND ASTROPHYSICS↗

A New Collaborative Tool for Visually Understanding National Health Indicators

The authors propose a new online collaborative tool for visually understanding national health indicators, which facilitates the full spectrum of investigation of indicators, from an overview of all the correlation coefficients between variables, to investigation of subsets of selected variables, and to individual data element analysis. this tool is publicly accessible at http://cda.ornl.gov/heat/heatmap.html. In this paper, they discuss the key issues regarding the interface design and implementation. They also illustrate how to use their interface for analyzing the health indicator dataset by showing some key system views. In the end, they introduce and discuss some ongoing research efforts extending this work.

59 BASIC BIOLOGICAL SCIENCES↗

EFFECT OF TEMPERATURE AND HUMIDITY ON FORMALDEHYDE EMISSIONS IN TEMPORARY HOUSING UNITS

The effect of temperature and humidity on formaldehyde emissions from samples collected from temporary housing units (THUs) was studied. The THUs were supplied by the U.S Federal Emergency Management Administration (FEMA) to families that lost their homes in Louisiana and Mississippi during the Hurricane Katrina and Rita disasters. Based on a previous study 1, 2, four of the composite wood surface materials that dominated contributions to indoor formaldehyde were selected to analyze the effects of temperature and humidity on the emission factors. Humidity equilibration experiments were carried out on two of the samples to determine how long the samples take to equilibrate with the surrounding environmental conditions. Small chamber experiments were then conducted to measure emission factors for the four surface materials at various temperature and humidity conditions. The samples were analyzed for formaldehyde via high performance liquid chromatography. The experiments showed that increases in temperature or humidity contributed to an increase in emission factors. A linear regression model was built using natural log of percentage relative humidity (RH) and inverse of temperature (in K) as predictor variables, and natural log of emission factors as the target variable. The coefficients of both inverse temperature and log relative humidity with log emission factor were found to be statistically significant for all the samples at the 95percent confidence level. This study should assist to retrospectively estimate indoor formaldehyde exposures of occupants of temporary housing units (THUs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

3-D Transient Hydraulic Tomography in Unconfined Aquifers with Fast Drainage Response

We investigate, through numerical experiments, the viability of three-dimensional transient hydraulic tomography (3DTHT) for identifying the spatial distribution of groundwater flow parameters (primarily, hydraulic conductivity K) in permeable, unconfined aquifers. To invert the large amount of transient data collected from 3DTHT surveys, we utilize an iterative geostatistical inversion strategy in which outer iterations progressively increase the number of data points fitted and inner iterations solve the quasilinear geostatistical formulas of Kitanidis. In order to base our numerical experiments around realistic scenarios, we utilize pumping rates, geometries, and test lengths similar to those attainable during 3DTHT field campaigns performed at the Boise Hydrogeophysical Research Site (BHRS). We also utilize hydrologic parameters that are similar to those observed at the BHRS and in other unconsolidated, unconfined fluvial aquifers. In addition to estimating K, we test the ability of 3DTHT to estimate both average storage values (specific storage Ss and specific yield Sy) as well as spatial variability in storage coefficients. The effects of model conceptualization errors during unconfined 3DTHT are investigated including: (1) assuming constant storage coefficients during inversion and (2) assuming stationary geostatistical parameter variability. Overall, our findings indicate that estimation of K is slightly degraded if storage parameters must be jointly estimated, but that this effect is quite small compared with the degradation of estimates due to violation of ‘‘structural’’ geostatistical assumptions. Practically, we find for our scenarios that assuming constant storage values during inversion does not appear to have a significant effect on K estimates or uncertainty bounds.

Environmental Molecular Sciences Laboratory↗

Optimality Conditions for Semilinear Hyperbolic Equations with Controls in Coefficients

An optimal control problem for semilinear hyperbolic partial differential equations is considered. The control variable appears in coefficients. Necessary conditions for optimal controls are established by method of two-scale convergence and homogenized spike variation. Results for problems with state constraints are also stated.

97 MATHEMATICS AND COMPUTING↗

WE-D-BRE-02: BEST IN PHYSICS (THERAPY) - Radiogenomic Modeling of Normal Tissue Toxicities in Prostate Cancer Patients Receiving Hypofractionated Radiotherapy

Purpose: It has been realized that inter-patient radiation sensitivity variability is a multifactorial process involving dosimetric, clinical, and genetic factors. Therefore, we explore a new framework to integrate physical, clinical, and biological data denoted as radiogenomic modeling. In demonstrating the feasibility of this work, we investigate the association of genetic variants (copy number variations [CNVs] and single nucleotide polymorphisms [SNPs]) with radiation induced rectal bleeding (RB) and erectile dysfunction (ED) while taking into account dosimetric and clinical variables in prostate cancer patients treated with curative irradiation. Methods: A cohort of 62 prostate cancer patients who underwent hypofractionated radiotherapy (66 Gy in 22 fractions) was retrospectively genotyped for CNV and SNP rs25489 in the xrcc1 DNA repair gene. Dosevolume metrics were extracted from treatment plans of 54 patients who had complete dosimetric profiles. Treatment outcomes were considered to be a Result of functional mapping of radiogenomic input variables according to a logit transformation. Model orders were estimated using resampling by leave-one out cross-validation (LOO-CV). Radiogenomic model performance was evaluated using area under the ROC curve (AUC) and LOO-CV. For continuous univariate dosimetric and clinical variables, Spearmans rank coefficients were calculated and p-values reported accordingly. In the case of binary variables, Chi-squared statistics and contingency table calculations were used. Results: Ten patients were found to have three copies of xrcc1 CNV (RB: χ2=14.6 [p<0.001] and ED: χ2=4.88[p=0.0272]) and twelve had heterozygous rs25489 SNP (RB: χ2=0.278[p=0.599] and ED: χ2=0.112[p=0.732]). LOO-CV identified penile bulb D60 as the only significant QUANTEC predictor (rs=0.312 [p=0.0145]) for ED. Radiogenomic modeling yielded statistically significant, cross-validated NTCP models for RB (rs=0.243[p=0.0443], AUC=0.665) and ED (rs=0.276[p=0.0217], AUC=0.754). Conclusion: The radiogenomic modeling approach presented herein has been shown to identify NTCP models which have increased predictive power. Furthermore, CNVs appears to be useful genetic variants when added to dosimetric NTCP models. This work was partially supported by CIHR grant MOP-114910.

60 APPLIED LIFE SCIENCES↗

A New Linearization Method of Unbalanced Electrical Distribution Networks

Abstract--- With increasing penetration of distributed generation in the distribution networks (DN), the secure and optimal operation of DN has become an important concern. As DN control and operation strategies are mostly based on the linearized sensitivity coefficients between controlled variables (e.g., node voltages, line currents, power loss) and control variables (e.g., power injections, transformer tap positions), efficient and precise calculation of these sensitivity coefficients, i.e. linearization of DN, is of fundamental importance. In this paper, the derivation of the node voltages and power loss as functions of the nodal power injections and transformers' tap-changers positions is presented, and then solved by a Gauss-Seidel method. Compared to other approaches presented in the literature, the proposed method takes into account different load characteristics (e.g., constant PQ, constant impedance, constant current and any combination of above) of a generic multi-phase unbalanced DN and improves the accuracy of linearization. Numerical simulations on both IEEE 13 and 34 nodes test feeders show the efficiency and accuracy of the proposed method.

linearization↗

Scattering of radiofrequency waves by randomly modulated density interfaces in the edge of fusion plasmas

In the scrape-off layer and the edge region of a tokamak, the plasma is strongly turbulent and scatters the radiofrequency (RF) electromagnetic waves that propagate through this region. It is important to know the spectral properties of these scattered RF waves, whether used for diagnostics or for heating and current drive. The spectral changes influence the interpretation of the obtained diagnostic data, and the current and heating profiles. A full-wave, three-dimensional (3-D) electromagnetic code ScaRF has been developed for studying the RF wave propagation through turbulent plasma. ScaRF is a finite-difference frequency-domain (FDFD) method used for solving Maxwell's equations. The magnetized plasma is defined through the cold plasma by the anisotropic permittivity tensor. As a result, ScaRF can be used to study the scattering of any cold plasma RF wave. It can also be used for the study of the scattering of electron cyclotron waves in ITER-type and medium-sized tokamaks such as TCV, ASDEX-U and DIII-D. For the case of medium-sized tokamaks, there is experimental evidence that drift waves and rippling modes are present in the edge region. Hence, we have studied the scattering of RF waves by periodic density interfaces (plasma gratings) in the form of a superposition of spatial modes with varying periodicity and random amplitudes. The power reflection coefficient (a random variable) is calculated for different realizations of the density interface. In this work, the uncertainty of the power reflection coefficient is rigorously quantified by use of the Polynomial Chaos Expansion method in conjunction with the Smolyak sparse-grid integration, which is known as the PCE-SG method. The PCE-SG method is proven to be accurate and more efficient compared with alternative methods such as the Monte Carlo (MC) approach.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EOSPAC User’s Manual (V.6.4)

The EOSPAC utility package is a collection of interface routines, which can be used to access the SESAME data library and perform various data adjustments and interpolations on the SESAME data. The SESAME data library contains both thermodynamic (e.g., equation of state) and transport coefficients (e.g., opacity and conductivity). Note, for simplicity, the term EOS (equation of state) used herein includes both thermodynamic variables and transport coefficients. The EOSPAC utility package is designed to be used by physics codes (henceforth ”host codes”) written in multiple languages and on multiple platforms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EOSPAC User’s Manual: V.6.5

The EOSPAC utility package is a collection of interface routines, which can be used to access the SESAME data library and perform various data adjustments and interpolations on the SESAME data. The SESAME data library contains both thermodynamic (e.g., equation of state) and transport coefficients (e.g., opacity and conductivity). Note, for simplicity, the term EOS (equation of state) used herein includes both thermodynamic variables and transport coefficients. The EOSPAC utility package is designed to be used by physics codes (henceforth "host codes") written in multiple languages and on multiple platforms. The remainder of this manual is organized into several sections.

97 MATHEMATICS AND COMPUTING↗

EOSPAC User's Manual: Version 6.5 Second Edition (Rev. 3)

The EOSPAC utility package is a collection of interface routines, which can be used to access the SESAME data library and perform various data adjustments and interpolations on the SESAME data. The SESAME data library contains both thermodynamic (e.g., equation of state) and transport coefficients (e.g., opacity and conductivity). Note, for simplicity, the term EOS (equation of state) used herein includes both thermodynamic variables and transport coefficients. The EOSPAC utility package is designed to be used by physics codes (henceforth ”host codes”) written in multiple languages and on multiple platforms. The remainder of this manual is organized into several sections. Chapter 2 discusses conventions such as data organization and routine names. Chapter 3 provides a general overview of basic theory and models implemented within EOSPAC. Chapter 4 provides a general overview of how to use the EOSPAC interface library. Chapters 5 to 7 describe the public interfaces of EOSPAC in detail. Chapter 8 provides a brief introduction to some related tools, which may be of use to the user. Chapter 9 provides details related to some selected numerical features of EOSPAC. Chapter 10 gives examples for using the interface routines described in chapters 5 to 7. Chapter 11 provides technical support contact information. Chapter 12 contains a brief set of acknowledgments. Chapter 13 contains a list of referenced documents. Finally, chapter 14 lists the “table types: mnemonic conventions”, “table types: grouped by category, sorted by name”, “table types: eospac version 5 cross reference”, “options: setup phase”, “data information parameters”, “meta-data information parameters”, “options: interpolation phase”, and the “error codes”.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scattering of radio frequency waves by randomly modulated density interfaces in the edge of fusion plasmas

In the scrape-off layer and the edge region of a tokamak, the plasma is strongly turbulent and scatters the radio frequency (RF) electromagnetic waves that propagate through this region. It is important to know, whether used for diagnostics or for heating and current drive, the spectral properties of these scattered RF waves. The spectral changes influences the interpretation of the diagnostic-data obtained and the current and heating profiles. A full-wave, 3D electromagnetic code ScaRF (see Papadopoulos et al. 2019) has been developed for studying the RF wave propagation through turbulent plasma. ScaRF is a finite-difference frequency-domain (FDFD) method for solving Maxwell's equations. The magnetized plasma is defined through the cold plasma, anisotropic permittivity tensor. As a result, ScaRF can be used to study the scattering of any cold plasma RF wave. It can be for the study of scattering of electron cyclotron waves in ITER-type and medium-sized tokamaks such as TCV, ASDEX-U, DIII-D. For the case of medium-sized tokamaks, there's experimental evidence that drift waves and rippling modes are present in the edge region (see Ritz et al. 1984). Hence, we study the scattering of RF waves by periodic density interfaces (plasma gratings) in the form of a superposition of spatial modes with varying periodicity and random amplitudes (see Papadopoulos et al. 2019). The power reflection coefficient (a random variable) is calculated for different realizations of the density interface. In this work, the uncertainty of the power reflection coefficient is rigorously quantified by use of the Polynomial Chaos Expansion (see Xiu & Karniadakis 2002) method in conjunction with the Smolyak sparse grid integration (see Papadopoulos et al. 2018) (PCE-SG). The PCE-SG method is proven accurate and much more efficient (roughly 2-orders of magnitude shorter execution time) compared to alternative methods such as the Monte Carlo (MC) approach.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Equilibration and analysis of first-principles molecular dynamics simulations of water

First-principles molecular dynamics (FPMD) simulations based on density functional theory are becoming increasingly popular for the description of liquids. In view of the high computational cost of these simulations, the choice of an appropriate equilibration protocol is critical. In this study, we assess two methods of estimation of equilibration times using a large dataset of first-principles molecular dynamics simulations of water. The Gelman-Rubin potential scale reduction factor [A. Gelman and D. B. Rubin, Stat. Sci. 7, 457 (1992)] and the marginal standard error rule heuristic proposed by White [Simulation 69, 323 (1997)] are evaluated on a set of 32 independent 64-molecule simulations of 58 ps each, amounting to a combined cumulative time of 1.85 ns. The availability of multiple independent simulations also allows for an estimation of the variance of averaged quantities, both within MD runs and between runs. We analyze atomic trajectories, focusing on correlations of the Kohn-Sham energy, pair correlation functions, number of hydrogen bonds, and diffusion coefficient. The observed variability across samples provides a measure of the uncertainty associated with these quantities, thus facilitating meaningful comparisons of different approximations used in the simulations. We find that the computed diffusion coefficient and average number of hydrogen bonds are affected by a significant uncertainty in spite of the large size of the dataset used. Lastly, a comparison with classical simulations using the TIP4P/2005 model confirms that the variability of the diffusivity is also observed after long equilibration times. Complete atomic trajectories and simulation output files are available online for further analysis.