Search NASA⌕ Search

SEARCH · Search NASA

Results for “visual tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Global Radiological Source Sorting, Tracking, and Monitoring (Gradsstram) Using Emergin RFID and Web 2.0 Technologies to Provide Total Asset and Information Visualization, Paper at 2009 INMM

Background Thousands of shipments of radioisotopes developed in the United States (U.S.) are transported domestically and internationally for medical and industrial applications, including to partner laboratories in European Union (EU) countries. Over the past five years, the Environmental Protection Agency (EPA), the Department of Energy (DOE), and Oak Ridge National Laboratory (ORNL)1 have worked with state first responder personnel, key private sector supply chain stakeholders, the Department of Homeland Security (DHS), the Department of Transportation (DOT), the Department of Defense (DoD) and the Nuclear Regulatory Commission (NRC) on Radio Frequency Identification (RFID) tracking and monitoring of medical, research and industrial radioisotopes in commerce. ORNL was the pioneer of the international radioisotope shipping and production business. Most radioisotopes made and used today were either made or discovered at ORNL. While most of the radioisotopes used in the commercial sector are now produced and sold by the private market, ORNL still leads the world in the production of exotic, high-value and/or sensitive industrial, medical and research isotopes. The ORNL-EPA-DOE Radiological Source Tracking and Monitoring (RadSTraM) project tested, evaluated, and integrated RFID technologies in laboratory settings and at multiple private-sector shipping and distribution facilities (Perkin Elmer and DHL) to track and monitor common radioisotopes used in everyday commerce. The RFID tracking capability was also tested in association with other deployed technologies including radiation detection, chemical/explosives detection, advanced imaging, lasers, and infrared scanning. At the 2007 EU-U.S. Summit, the leaders of the US Department of Commerce (DOC) and EU European Commission (EC) committed to pursue jointly directed Lighthouse Priority Projects. These projects are intended to foster cooperation and reduce regulatory burdens with respect to transatlantic commerce. The Transatlantic Economic Council (TEC) Lighthouse Project on Radio Frequency Identification (RFID) has been directed to develop a joint framework for cooperation on identification and development of best practices for Radio Frequency Identification (RFID) technologies The RFID Lighthouse Priority Project commits both sides to endeavor to align U.S. and EU regulatory and policy approaches on RFID technologies, including pilot projects in the public sector.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Motion Tracking Of A Handheld Scanner With An Infrared Vision System

Handheld scanners are used in a large number of applications to inspect walls, floors, tanks, and other large structures. Measurements are made to characterize physical properties, uncover defects, detect evidence of tampering, quantify surface contamination, and so forth. Handheld scanning suffers from a number of drawbacks. The relationship between the data collected and scanned location is difficult or impossible to track. Humans using handheld scanners can unintentionally scan the same area multiple times or entirely overlook an area of interest. An automated scanner tracking system could improve upon current inspection practices with a handheld scanner in terms of efficiency, accuracy, and quality. The authors have developed a handheld scanner tracking system that will allow users to visualize previously scanned areas, highlight areas where important or unusual data are acquired, and store scanning location with acquired data. The scanned regions are saved in real time and projected back on the scanned area using a projector. The system currently utilizes the Smoothboard software, which has already been designed to interpret the location of a captured infrared source from a Wii Remote controller to create an interactive whiteboard. This software takes advantage of the Wii Remote’s ability to track the location of an infrared source, and when proper calibration of the Wii Remote orientation is complete, any surface can become a virtual whiteboard. In addition to recording and projecting scan pathways, the system developed by the authors can be used to make notes on the scanning process and project acquired data on top of the scanned area. This latter capability can be used to guide sample acquisition or demolition activities. This paper discusses development of the system and potential benefits to wall scanning with handheld scanners.

Wii Remote, Wall scanner, IR tracking, Motion Trac↗

Principles and biophysical applications of single particle super-localization and rotational tracking

While conventional Single Particle Tracking (SPT) techniques acquire 2D or 3D trajectories of particle probes, we have developed Single Particle Orientation and Rotational Tracking (SPORT) techniques to extract orientation and rotational information. Combined with DIC microscopy, the SPORT technique has been applied in biophysical studies, including membrane diffusion and intracellular transport. The rotational dynamics of nanoparticle vectors on live cell membranes was recorded and its influence on the fate of these nanoparticle vectors was elucidated. The rotational motions of gold nanorods with various surface modifiers were tracked continuously at a temporal resolution of 5 ms under a DIC microscope. We found that the rotational behaviors of gold nanorod vectors are strongly related to their surface charge, specific surface functional groups, and the availability of receptors on cell membranes. The study of rotational Brownian motion of nanoparticles on cell membranes will lead to a better understanding of the mechanisms of drug delivery and provide guidance in designing surface modification strategies for drug delivery vectors under various circumstances. To characterize the rotation mode of surface functionalized gold nanorods on cell membranes, the SPORT technique is combined with the correlation analysis of the bright and dark DIC intensities. The unique capabilities of visualizing and understanding rotational motions of functionalized nanoparticles on live cell membranes allow us to correlate rotational and translational dynamics in unprecedented detail and provide new insights for complex membrane processes, including electrostatic interactions, ligand-receptor binding, and lateral (confined and hopping) diffusion of membrane receptors. Surface-functionalized nanoparticles interact with the membrane in fundamentally different ways and exhibit distinct rotational modes. The early events of particle-membrane approach and attachment are directly visualized for the first time. The rotational dynamics of cargos in both active directional transport and pausing stages of axonal transport was also visualized using high-speed SPORT with a temporal resolution of 2 ms. Both long and short pauses are imaged, and the correlations between the pause duration, the rotational behaviour of the cargo at the pause, and the moving direction after the pause are established. Furthermore, the rotational dynamics leading to switching tracks are visualized in detail. These first-time observations of cargo's rotational dynamics provide new insights on how kinesin and dynein motors take the cargo through the alternating stages of active directional transport and pause. To improve the localization precision of the SPT technique with DIC microscopy, a precise three-dimensional (3D) localization method of spherical gold nanoparticle probes using model-based correlation coefficient mapping was introduced. To accomplish this, a stack of sample images at different z-positions are acquired, and a 3D intensity profile of the probe serving as the model is used to map out the positions of nanoparticles in the sample. By using this model-based correlation imaging method, precise localization can be achieved in imaging techniques with complicated point spread functions (PSF) such as differential interference contrast (DIC) microscopy. The 3D superlocalization method was applied to tracking gold nanospheres during live endocytosis events. Finally, a novel dual-modality imaging technique has been developed to super-localize a single gold nanorod while providing its orientation and rotational information. The super-localization of the gold nanorod can be accomplished by curve fitting the modified bright-field images generated by one of the two beams laterally shifted by the first Nomarski prism in a DIC microscope. The orientation and rotational information is derived from the DIC images of gold nanorods. The new imaging setup has been applied to study the steric hindrance induced by relatively large cargos in the microtubule gliding assay and to track nanocargos in the crowded cellular environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-J-196: New Visualization Methods for Longitudinal MRI Registrations and Segmentations

Purpose: To develop visualization techniques to facilitate easy assessment of (a) registration and (b) tracking volumetric changes in structures during radiation therapy from MRI. Method: The frequently used method for visualizing registrations between scans is a multi-color overlay technique or deformation vector fields. However, the overlay technique is unintuitive and does not help to appreciate the quality of registration particularly when the registration mismatches are not very large. Similarly, the deformation fields give an indication of extent of deformation but do not help to assess the differences in registration. We present a mirroring and edge-augmented mirroring technique that places the fixed and moving image next to each other and allows the user to quickly assess the small differences in registration. Next, we present a volumetric intersection based 3D model to visualize the changes in diseased lymph node volumes in head and neck cancer. 3D model-based visualization provides more information about the location-specific changes in volume rather than the simplistic one dimensional information obtained from 2D plot of nodal volume changes. Result: We show results comparing our approach with the standard colorbased overlay method for comparing registrations of intra-patient registrations using T2-MRI. Upon comparing the mirroring technique with the color-overlay, one can more easily appreciate the differences in registration. Adding edge-based mirroring seems to further assist in evaluating the registration. Our approach for viewing registrations seems to be more intuitive and easy to use in order to help assess the quality of registration compared to color-based overlays. Similarly, the change volumetric model together with a 2D plot reveals more information including the locations undergoing changes and responding to treatment. Conclusions: Better approaches are necessary for assessing the quality of registrations and changes in diseased structures over time. Our approach presents some novel visualization solutions for registration and segmentation.

60 APPLIED LIFE SCIENCES↗

A new method for tracking organ motion on diagnostic ultrasound images

Purpose: Respiratory-gated irradiation is effective in reducing the margins of a target in the case of abdominal organs, such as the liver, that change their position as a result of respiratory motion. However, existing technologies are incapable of directly measuring organ motion in real-time during radiation beam delivery. Hence, the authors proposed a novel quantitative organ motion tracking method involving the use of diagnostic ultrasound images; it is noninvasive and does not entail radiation exposure. In the present study, the authors have prospectively evaluated this proposed method. Methods: The method involved real-time processing of clinical ultrasound imaging data rather than organ monitoring; it comprised a three-dimensional ultrasound device, a respiratory sensing system, and two PCs for data storage and analysis. The study was designed to evaluate the effectiveness of the proposed method by tracking the gallbladder in one subject and a liver vein in another subject. To track a moving target organ, the method involved the control of a region of interest (ROI) that delineated the target. A tracking algorithm was used to control the ROI, and a large number of feature points and an error correction algorithm were used to achieve long-term tracking of the target. Tracking accuracy was assessed in terms of how well the ROI matched the center of the target. Results: The effectiveness of using a large number of feature points and the error correction algorithm in the proposed method was verified by comparing it with two simple tracking methods. The ROI could capture the center of the target for about 5 min in a cross-sectional image with changing position. Indeed, using the proposed method, it was possible to accurately track a target with a center deviation of 1.54 ± 0.9 mm. The computing time for one frame image using our proposed method was 8 ms. It is expected that it would be possible to track any soft-tissue organ or tumor with large deformations and changing cross-sectional position using this method. Conclusions: The proposed method achieved real-time processing and continuous tracking of the target organ for about 5 min. It is expected that our method will enable more accurate radiation treatment than is the case using indirect observational methods, such as the respiratory sensor method, because of direct visualization of the tumor. Results show that this tracking system facilitates safe treatment in clinical practice.

60 APPLIED LIFE SCIENCES↗

AMPP-4 Tank Tracking Tools

The Material Recovery & Recycle group (AMPP-4) Tank Tracking Tools are Microsoft Excel-based tools used to visualize the liquid levels in the tanks used by teams within AMPP-4. The tools rely on reports generated by the Tracking Hydrogen Accumulation in Aqueous Operations spreadsheet to provide daily data of the volume occupied by radioactive liquid waste (RLW). This set-up allows for rapid-response in viewing historical (from October 2024) and current data in thermometer-type charts.

97 MATHEMATICS AND COMPUTING↗

Computerized analysis of coronary artery disease: Performance evaluation of segmentation and tracking of coronary arteries in CT angiograms

Purpose: The authors are developing a computer-aided detection system to assist radiologists in analysis of coronary artery disease in coronary CT angiograms (cCTA). This study evaluated the accuracy of the authors’ coronary artery segmentation and tracking method which are the essential steps to define the search space for the detection of atherosclerotic plaques. Methods: The heart region in cCTA is segmented and the vascular structures are enhanced using the authors’ multiscale coronary artery response (MSCAR) method that performed 3D multiscale filtering and analysis of the eigenvalues of Hessian matrices. Starting from seed points at the origins of the left and right coronary arteries, a 3D rolling balloon region growing (RBG) method that adapts to the local vessel size segmented and tracked each of the coronary arteries and identifies the branches along the tracked vessels. The branches are queued and subsequently tracked until the queue is exhausted. With Institutional Review Board approval, 62 cCTA were collected retrospectively from the authors’ patient files. Three experienced cardiothoracic radiologists manually tracked and marked center points of the coronary arteries as reference standard following the 17-segment model that includes clinically significant coronary arteries. Two radiologists visually examined the computer-segmented vessels and marked the mistakenly tracked veins and noisy structures as false positives (FPs). For the 62 cases, the radiologists marked a total of 10191 center points on 865 visible coronary artery segments. Results: The computer-segmented vessels overlapped with 83.6% (8520/10191) of the center points. Relative to the 865 radiologist-marked segments, the sensitivity reached 91.9% (795/865) if a true positive is defined as a computer-segmented vessel that overlapped with at least 10% of the reference center points marked on the segment. When the overlap threshold is increased to 50% and 100%, the sensitivities were 86.2% and 53.4%, respectively. For the 62 test cases, a total of 55 FPs were identified by radiologist in 23 of the cases. Conclusions: The authors’ MSCAR-RBG method achieved high sensitivity for coronary artery segmentation and tracking. Studies are underway to further improve the accuracy for the arterial segments affected by motion artifacts, severe calcified and noncalcified soft plaques, and to reduce the false tracking of the veins and other noisy structures. Methods are also being developed to detect coronary artery disease along the tracked vessels.

60 APPLIED LIFE SCIENCES↗

Quench-Spot Detection for Superconducting Accelerator Cavities Via Flow Visualization in Superfluid Helium-4

Superconducting radio-frequency (SRF) cavities, cooled by superfluid helium-4 (He II), are key components in modern particle accelerators. Quenches in SRF cavities caused by Joule heating from local surface defects can severely limit the maximum achievable accelerating field. Existing methods for quench-spot detection include temperature mapping and second-sound triangulation. These methods are useful but also have known limitations. Here we describe an alternative method for surface quench-spot detection by visualizing the heat transfer in He II via tracking He2 molecular tracer lines. A proof-of-concept experiment is conducted, in which a miniature heater mounted on a plate is pulsed on to simulate a surface quench spot. A He2 tracer line created nearby the heater deforms due to the counterflow heat transfer in He II. By analyzing the tracer-line deformation, we well reproduce the heater location within a few hundred microns, which clearly demonstrates the feasibility of this alternative technology. Our analysis also reveals that the heat content transported in He II is only a small fraction of the total input heat energy. We show that the remaining energy is essentially consumed in the formation of a cavitation zone near the heater. By estimating the size of this cavitation zone, we discuss how the existence of the cavitation zone may explain a decades-long puzzle observed in many past second-sound triangulation experiments.

43 PARTICLE ACCELERATORS↗

Design of a Combined Proportional Integral Derivative Controller to Regulate the Temperature Inside a High-Temperature Tubular Solar Reactor

Solar fuels are proven to be promising candidates for thermochemical energy storage. However, the transient nature of solar radiation is an obstacle to maintaining a stable operational temperature inside a solar reactor. To overcome this challenge, the temperature of a solar reactor can be regulated by controlling the incoming solar radiation or the feedstock flowrate inside the reactor. In this work, a combined proportional integral derivative (PID) controller is implemented to regulate the temperature inside a high-temperature tubular solar reactor with counter-current flowing gas/particles. The control model incorporates two control systems to regulate incoming solar radiation and gas flow simultaneously. The design of the controller is based on a reduced-order numerical model of a high-temperature tubular solar reactor that is vertically oriented with an upward gas flow and downward particle flow. The reactor receives heat circumferentially through its wall over a finite segment of its length. Formulation of the heat transfer model is presented by applying the energy balance for the reactor tube and considering heat and mass transfer inside. A set of governing differential equations are solved numerically by using the finite volume method to obtain reactor wall, particles, and gas temperatures along the reactor length with various boundary conditions. Simulation results are used to tune the PID controller parameters by utilizing the Ziegler–Nichols tuning method. Both the simulation results and the controller performance are visualized on the LABVIEW platform. The controller is challenged to track different temperature setpoints with different scenarios of transient solar radiation. Here, the performance of the PID controller was compared to experimental results obtained from an industrial PID controller embedded in a 7 kW electric furnace. Results show that the combined PID controller is successful in maintaining a stable temperature inside the reactor by regulating the incoming solar radiation and the flowrate via small steady-state error and reasonable settling time and overshoot.

14 SOLAR ENERGY↗

Advanced Imaging of the Left Atrium with Cardiac Magnetic Resonance: A Review of Current and Emerging Methods and Clinical Applications

Purpose of Review: The thin wall of the left atrium (LA) is difficult to visualize. The high spatial and temporal resolution of cardiac magnetic resonance (CMR) allows for the most accurate assessment of left atrial structure, function, and tissue characterization. This review will describe emerging methods used to image the LA with CMR, and will discuss associated clinical applications. Recent Findings: LA function can now be described in a dynamic fashion with feature-tracking algorithms. Novel methods have been created to augment visualization of late gadolinium enhancement (LGE) in the LA, and left atrial fibrosis can be further quantified with T1 mapping algorithms. The advancement in how we image the LA with CMR has implications in atrial fibrillation (AF) and cardiomyopathic processes. Summary: A nuanced understanding of left atrial pathology is emerging with the rapid advancement of CMR technology, which has implications in the risk stratification and treatment of several cardiovascular disease states.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-214: MR Protocol Development to Visualize Sirius MRI Markers in Prostate Brachytherapy Patients for MR-Based Post-Implant Dosimetry

Purpose: The current CT-based post-implant dosimetry allows precise seed localization but limited anatomical delineation. Switching to MR-based post-implant dosimetry is confounded by imprecise seed localization. One approach is to place positive-contrast markers (Sirius) adjacent to the negative-contrast seeds. This patient study aims to assess the utility of a 3D fast spoiled gradient-recalled echo (FSPGR) sequence to visualize Sirius markers for post-implant dosimetry. Methods: MRI images were acquired in prostate implant patients (n=10) on Day 0 (day-of-implant) and Day 30. The post-implant MR protocol consisted of 3D T2-weighted fast-spin-echo (FSE), T2-weighted 2D-FSE (axial) and T1-weighted 2D-FSE (axial/sagittal/coronal). We incorporated a 3D-FSPGR sequence into the post-implant MR protocol to visualize the Sirius markers. Patients were scanned with different number-of-excitations (6, 8, 10), field-of-view (10cm, 14cm, 18cm), slice thickness (1mm, 0.8mm), flip angle (14 degrees, 20 degrees), bandwidth (122.070 Hz/pixel, 325.508 Hz/pixel, 390.625 Hz/pixel), phase encoding steps (160, 192, 224, 256), frequency-encoding direction (right/left, anterior/posterior), echo-time type (minimum-full, out-of-phase), field strength (1.5T, 3T), contrast (with, without), scanner vendor (Siemens, GE), coil (endorectal-coil only, endorectal-and-torso-coil, torsocoil only), endorectal-coil filling (30cc, 50cc) and endorectal-coil filling type (air, perfluorocarbon [PFC]). For post-implant dosimetric evaluation with greater anatomical detail, 3D-FSE images were fused with 3D-FSPGR images. For comparison with CT-based post-implant dosimetry, CT images were fused with 3D-FSPGR images. Results: The 3D-FSPGR sequence facilitated visualization of markers in patients. Marker visualization helped distinguish signal voids as seeds versus needle tracks for more definitive MR-based post-implant dosimetry. On the CT-MR fused images, the distance between the seed on CT to MR images was 3.2±1.6mm in patients with no endorectal coil, 2.3±0.8mm in patients with 30cc-PFC-filled endorectal-coil and 5.0±1.8mm in patients with 50cc-PFC-filled endorectal-coil. Conclusion: An MR protocol to visualize positive-contrast Sirius markers to assist in the identification of negative-contrast seeds was demonstrated. S Frank is a co-founder of C4 Imaging LLC, the manufacturer of the MRI markers.

60 APPLIED LIFE SCIENCES↗

3D model generation using an airborne swarm

Using an artificial kinematic field to provide co-ordination between multiple inspection UAVs, the authors herein demonstrate full 3D modelling capability based on a photogrammetric system. The operation of the system is demonstrated by generating a full 3D surface model of an intermediate level nuclear waste storage drum. Such drums require periodic inspection to ensure that drum distortion or corrosion is carefully monitored. Performing this inspection with multiple airborne platforms enables rapid inspection of structures that are inaccessible to on-surface remote vehicles and are in human-hazardous environments. A three-dimensional surface-meshed model of the target can then be constructed in post-processing through photogrammetry analysis of the visual inspection data. The inspection environment uses a tracking system to precisely monitor the position of each aerial vehicle within the enclosure. The vehicles used are commercially available Parrot AR. Drone quadcopters, controlled through a computer interface connected over an IEEE 802.11n (WiFi) network, implementing a distributed controller for each vehicle. This enables the autonomous and distributed elements of the control scheme to be retained, while alleviating the vehicles of the control algorithm’s computational load. The control scheme relies on a kinematic field defined with the target at its centre. This field defines the trajectory for all the drones in the volume relative to the central target, enabling the drones to circle the target at a set radius while avoiding drone collisions. This function enables complete coverage along the height of the object, which is assured by transitioning to another inspection band only after completing circumferential coverage. Using a swarm of vehicles, the time until complete coverage can be significantly reduced.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A New Tool for Effective and Efficient Project Management

Organizations routinely handle thousands of projects per year, and it is difficult to manage all these projects concurrently. Too often, projects do not get the attention they need when they need it. Management inattention can lead to late projects or projects with less than desirable content and/or deliverables. This paper discusses the application of Visual Project Management (VPM) as a method to track and manage projects. The VPM approach proved to be a powerful management tool without the overhead and restrictions of traditional management methods.

99 GENERAL AND MISCELLANEOUS↗

An Integrated Approach to Parameter Learning in Infinite-Dimensional Space

The availability of sophisticated modern physics codes has greatly extended the ability of domain scientists to understand the processes underlying their observations of complicated processes, but it has also introduced the curse of dimensionality via the many user-set parameters available to tune. Many of these parameters are naturally expressed as functional data, such as initial temperature distributions, equations of state, and controls. Thus, when attempting to find parameters that match observed data, being able to navigate parameter-space becomes highly non-trivial, especially considering that accurate simulations can be expensive both in terms of time and money. Existing solutions include batch-parallel simulations, high-dimensional, derivative-free optimization, and expert guessing, all of which make some contribution to solving the problem but do not completely resolve the issue. In this work, we explore the possibility of coupling together all three of the techniques just described by designing user-guided, batch-parallel optimization schemes. Our motivating example is a neutron diffusion partial differential equation where the time-varying multiplication factor serves as the unknown control parameter to be learned. We find that a simple, batch-parallelizable, random-walk scheme is able to make some progress on the problem but does not by itself produce satisfactory results. After reducing the dimensionality of the problem using functional principal component analysis (fPCA), we are able to track the progress of the solver in a visually simple way as well as viewing the associated principle components. This allows a human to make reasonable guesses about which points in the state space the random walker should try next. Thus, by combining the random walker's ability to find descent directions with the human's understanding of the underlying physics, it is possible to use expensive simulations more efficiently and more quickly arrive at the desired parameter set.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Framework and algorithms for illustrative visualizations of time-varying flows on unstructured meshes

Photo- and physically realistic techniques are often insufficient for visualization of fluid flow simulations, especially for 3D and time-varying studies. Substantial research effort has been dedicated to the development of non-photorealistic and illustration-inspired visualization techniques for compact and intuitive presentation of such complex datasets. However, a great deal of work has been reproduced in this field, as many research groups have developed specialized visualization software. Additionally, interoperability between illustrative visualization software is limited due to diverse processing and rendering architectures employed in different studies. In this investigation, a framework for illustrative visualization is proposed, and implemented in MarmotViz, a ParaView plug-in, enabling its use on a variety of computing platforms with various data file formats and mesh geometries. Region-of-interest identification and feature-tracking algorithms incorporated into this tool are described. Implementations of multiple illustrative effect algorithms are also presented to demonstrate the use and flexibility of this framework. Here, by providing an integrated framework for illustrative visualization of CFD data, MarmotViz can serve as a valuable asset for the interpretation of simulations of ever-growing scale.

42 ENGINEERING↗

An MCNP6 Version of the Visual Editor - Paper 2

The Visual Editor is a graphical user interface for working with the MCNP computer code developed at Los Alamos National Laboratory. It consists of a graphical user interface written in C++ that is linked directory to the MCNP Fortran code. Work on the original Visual Editor started in 1992 and was first published in 1993. The original version of the Visual Editor was created on Unix/Linux operating systems and was linked to the MCNP computer code. The Visual Editor was adapted to the Windows operating system in 1999. In 2008 the Visual Editor was adapted to work with the MCNPX computer code. This paper discusses the latest upgrade of the Visual Editor to be compatible with the MCNP6 computer code. Two graphical user interfaces have been created, the Visual MCNP6 Plotter and the Visual MCNP6 Editor. The Visual MCNP6 Plotter includes all of the standard plotting features available in the default MCNP6 plotting package including geometry plotting, tally plotting, cross section plotting, mesh tally plotting and weight window mesh plotting. The Visual MNCP6 Editor has additional capabilities to allow for the creation of MCNP input files with graphical tools. The Visual MCNP6 Editor allows user to create and modify the input file within the Editor. Modifications are not allowed in the Visual MCNP6 Plotter. Both graphical user interfaces allow for advanced plotting features including 3D geometry plots and particle track plotting. Complete details on these tools along with their current status can be found at the Visual Editor website (www.mcnpvised.com). (author)

61 RADIATION PROTECTION AND DOSIMETRY↗

The CommonGround Visual Paradigm for Biosurveillance

Biosurveillance is a critical area in the intelligence community for real-time detection of disease outbreaks. Identifying epidemics enables analysts to detect and monitor disease outbreaks that might be spread from natural causes or from possible biological warfare attacks. Containing these events and disseminating alerts requires the ability to rapidly find, classify and track harmful biological signatures. In this paper, we describe a novel visual paradigm to conduct biosurveillance using an Infectious Disease Weather Map. Our system provides a visual common ground in which users can view, explore and discover emerging concepts and correlations such as symptoms, syndromes, pathogens, and geographic locations.

Livnat, Yarden↗

Computing and visualizing time-varying merge trees for high-dimensional data

We introduce a new method that identifies and tracks features in arbitrary dimensions using the merge tree -- a structure for identifying topological features based on thresholding in scalar fields. This method analyzes the evolution of features of the function by tracking changes in the merge tree and relates features by matching subtrees between consecutive time steps. Using the time-varying merge tree, we present a structural visualization of the changing function that illustrates both features and their temporal evolution. We demonstrate the utility of our approach by applying it to temporal cluster analysis of high-dimensional point clouds.

97 MATHEMATICS AND COMPUTING↗