Search NASA⌕ Search

SEARCH · Search NASA

Results for “water density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

East River Watershed Stable Water Isotope Data in Precipitation, Snowpack and Snowmelt 2016-2020

Stable water isotopes (d18O, d2H and d-excess) are important tracers in hydrologic research to understand water partitioning between vegetation, groundwater, and runoff but are rarely applied to large watersheds with persistent snowpack and complex topopgraphy. Data were collected for the Lawrence Berkeley National Laboratory Watershed Function Science Focus Area supported by the U.S Department of Energy in the East River, CO Hydrologic Unit Code (140200010) with limited data also collected in adjacent watersheds Ohio Creek and Taylor River. Data are provided in csv and includes isotopic information for precipitation (years 2014-2016), snowmelt (years 2016-2017) and snowpits (years 2016-2020). Snowpit data contain depth resolved information at 10 cm intervals for density, snow water equivalent (SWE) and stable water isotopes. Bulk isotopic data for 86 snowpits contain depth, SWE, density and SWE-weighted isotope values. Sampling locations and elevations are provided within the data files, while kmz files are provided to view sampling locations using Google Earth software.

54 ENVIRONMENTAL SCIENCES↗

Ecological optimality in water-limited natural soil-vegetation systems. II - Tests and applications

The long-term optimal climatic climax soil-vegetation system is defined for several climates according to previous hypotheses in terms of two free parameters, effective porosity and plant water use coefficient. The free parameters are chosen by matching the predicted and observed average annual water yield. The resulting climax soil and vegetation properties are tested by comparison with independent observations of canopy density and average annual surface runoff. The climax properties are shown also to satisfy a previous hypothesis for short-term optimization of canopy density and water use coefficient. Using these hypotheses, a relationship between average evapotranspiration and optimum vegetation canopy density is derived and is compared with additional field observations. An algorithm is suggested by which the climax soil and vegetation properties can be calculated given only the climate parameters and the soil effective porosity. Sensitivity of the climax properties to the effective porosity is explored.

Eagleson, P. S.↗

Commercial off-the-Shelf (COTS) Refractory Material Evaluation

Fondu Fyre (FF) is currently the only refractory material qualified for use in the flame trench at KSC's Shuttle Launch Pads 39A and 39B. However, the material is not used as it was qualified and has undergone increasingly frequent and severe degradation due to the launch blasts. This degradation is costly as well as dangerous for launch infrastructure, crew and vehicle. FF is applied at the pad via the gunnite process, where wetted refractory material is sprayed onto a steel grid mounted on a support structure. The water content in this process can be manually adjusted by operators, causing distinct visual and physical discrepancies among repair areas. Since the application process is unlikely to change for new refractory materials, it is important to understand the effects of water content on commercial off-the-shelf (COTS) refractory materials. The purpose of this study was to evaluate the performance of the FF with respect to various water contents as well as heat treatments, to simulate aging and exposure to the blast. Initial results indicated that different water contents and heat treatments result in distinct differences in crushing strength, apparent porosity and bulk density. However, water content became an insignificant factor in both crush strength and porosity when FF was cured to at least 1500 deg. Additionally, inspection of the material's surface microstructure by scanning electron microscopy indicated distinguishable characteristics for different heat treatment levels. Results from this study will help guide future studies on the development and identification of new refractory materials.

Calle, Luz Marina↗

Search for Interstellar Water in the Translucent Molecular Cloud Toward HD 154368

We report an upper limit of 9 x 10(exp 12)/sq cm on the column density of water in the translucent cloud along the line of sight toward HD 154368. This result is based on a search for the C-X band of water near 1240 A carried out using the Goddard High-Resolution Spectrograph (GHRS) of the Hubble Space Telescope. Our observational limit on the water abundance, together with detailed chemical models of translucent clouds and previous measurements of OH along the line of sight, constrains the branching ratio in the dissociative recombination of H3O(+) to form water. We find at the 3 sigma level that no more than 30% of dissociative recombinations of H3O(+) can lead to H2O. The observed spectrum also yielded high-resolution observations of the Mg II doublet at 1239.9 A and 1240.4 A, allowing the velocity structure of the dominant ionization state of magnesium to be studied along the line of sight. The Mg II spectrum is consistent with GHRS observations at lower spectral resolution that were obtained previously but allow an additional velocity component to be identified.

Spaans, Marco↗

Ionospheric Mapping with the GPS/MET

The GPS/MET experiment, which placed a GPS receiver in a low-Earth orbit tracking the GPS in an occultation geometry, has collected thousands of occultations since its launch in April of 1995. Each occultation can be inverted to give an electron density profile in the ionosphere, temperature and pressure profiles in the lower mesosphere, stratosphere and upper troposphere, and water vapor density profiles in the lower troposphere. This paper gives a summary of the ionospheric effects on the GPS/MET signal and examines some of the retrieved electron density profiles. We examine the bending induced by the ionosphere on the occulting signal and the resulting separation of the two GPS links corresponding to the L1 and L2 phase signals. We also examine the amplitude scintillation caused by sharp layers at the bottom of the ionosphere. We briefly describe the Abel inversion method for obtaining the index of refraction and show several examples of electron density profiles and comparisons derived from the Parameterized Ionospheric Model (PIM) and to incoherent scatter radar measurements.

GPS↗

Evaporation of ice in planetary atmospheres: Ice-covered rivers on Mars

The evaporation rate of water ice on the surface of a planet with an atmosphere involves an equilibrium between solar heating and radiative and evaporative cooling of the ice layer. The thickness of the ice is governed principally by the solar flux which penetrates the ice layer and then is conducted back to the surface. Evaporation from the surface is governed by wind and free convection. In the absence of wind, eddy diffusion is caused by the lower density of water vapor in comparison to the density of the Martian atmosphere. For mean martian insolations, the evaporation rate above the ice is approximately 10 to the minus 8th power gm/sq cm/s. Evaporation rates are calculated for a wide range of frictional velocities, atmospheric pressures, and insolations and it seems clear that at least some subset of observed Martian channels may have formed as ice-chocked rivers. Typical equilibrium thicknesses of such ice covers are approximately 10m to 30 m; typical surface temperatures are 210 to 235 K.

Wallace, D.↗

Insights into Sustainable Nitrogen Fixation by Gas-phase Spectroscopic Measurements and Global Modeling of Reaction Intermediates in Humid Nitrogen Plasma

In this article, there is growing interest in reacting molecular nitrogen and water to sustainably synthesize fixed forms of nitrogen such as ammonia. In particular, low-temperature plasmas can activate these relatively inert feedstocks at or near room temperature without a catalyst. However, because of the enhanced reactivity and nonequilibrium chemistry, a diverse range of products is formed, and the underlying reaction mechanisms are exceedingly complex. In this work, we studied a simplified reactor consisting of a gaseous plasma containing controlled mixtures of nitrogen gas and water vapor. Densities of key chemical species such as N, H, OH, NH, and NO were measured by emission and laser-based spectroscopy as a function of the relative humidity. A global model was constructed and the reaction network was validated by comparing calculated species densities with experiments. We discover that N, a key initial intermediate for ammonia, strongly decreases in the presence of water vapor, and as a result, ammonia formation becomes limited at high relative humidity. This decrease is surprisingly not because N itself reacts, but because one of its main sources, an excited molecular nitrogen state, is reacted away. In addition, oxidation pathways for nitrogen, which lead to NO and related products, are found to be favored over reduction pathways because the corresponding reverse reactions are less significant. Together, this understanding helps explain previously reported observations of selectivity toward nitrogen oxides over ammonia, particularly at higher relative humidities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transition from ring to beam arc distributions of water ions near the Space Shuttle orbiter

The distribution function of water ions produced near the Space Shuttle by charge exchange between ionospheric oxygen ions and outgassed water molecules is studied. The transition from a ring to a beam arc distribution function is described. The number density of water ions is found to increase monotonically with decreasing distance from the Shuttle.

Cairns, Iver H.↗

Bentonite buffer under high temperature: laboratory experiments and coupled process modeling

Abstract. Bentonite buffer in a geological repository will be simultaneously heated from decaying radioactive waste and hydrated from the surrounding host rock, triggering complex and coupled THMC (thermal–hydrological–mechanical–chemical) processes. Understanding the THMC behavior of bentonite-based engineered barrier system (EBS) is key to the evaluation and prediction of its long-term performance. Studies on the THMC process have been focused on conditions under 100 ∘C, as most design concepts impose a thermal limit of 100 ∘C in bentonite. Recently, studies under high-temperature conditions have been conducted to evaluate the possibility of raising the thermal limit and expanding the data/knowledge base to increase the confidence level. In this abstract, we present a series of bench-scale laboratory experiments at high temperatures (up to 200 ∘C) and the corresponding modeling work. Two sets of column tests were conducted, and each set consisted of two test columns: a control column undergoing only hydration (non-heated) and an experiment column experiencing both heating and hydration (heated). During the experiment, frequent X-ray computed tomography (CT) images were collected to provide a 3D visualization of the density distribution and present the spatiotemporal evolution of (1) hydration/dehydration, (2) clay swelling/shrinkage, (3) displacement, and (4) mineral precipitation. The two sets of tests differ with respect to several experimental conditions, such as bentonite type, compacted density and water content, water chemistry, and hydration pressure, but the important difference is that the first set used bentonite powder with a dry density of 1.28 g cm−3, whereas the second set used granulated bentonite (mixture of pellets and powder) with a dry density of 1.45–1.5 g cm−3. In both sets of experiments, a comprehensive post-dismantling characterization of bentonite samples was carried out after the column tests had been running for 1.5 years. Comparing non-heated and heated columns, the temperature gradient led to lower degree of homogenization of bentonite after bentonite became fully saturated; comparing the first and second sets, granulated and powdered bentonite exhibited drastically different hydration behavior. A THM model with a 2D axisymmetric grid system was used to interpret the data from the first set of tests. The model considers the combined impact of saturation, fluid pressure, and porosity change due to swelling/compression on the spatiotemporal distribution of bulk density and movement of the thermocouple modules. Observations from the tests help us understand the early perturbation of bentonite buffer under high temperature, and data from these tests improve the calibration of key constitutive hydrological and mechanical models and, therefore, enhance the modeling capability with respect to calculating the long-term evolution of bentonite buffer.

Zheng, Liange↗

Differential absorption and Raman lidar for water vapor profile measurements - A review

Differential absorption lidar and Raman lidar have been applied to the range-resolved measurements of water vapor density for more than 20 years. Results have been obtained using both lidar techniques that have led to improved understanding of water vapor distributions in the atmosphere. This paper reviews the theory of the measurements, including the sources of systematic and random error; the progress in lidar technology and techniques during that period, including a brief look at some of the lidar systems in development or proposed; and the steps being taken to improve such lidar systems.

Grant, William B.↗

Evaluation of GEOS Total Cloud Fraction with GLOBE Citizen Science Observations and Co-Located Satellite Data

Here we evaluate the total cloud fraction in cycled forecast experiments with the NASA Global Earth Observing System (GEOS) model. Forecasts were run for summer and winter periods of 2017/2018 and compared with ground-based and satellite observations. Citizen science observations from the Global Learning and Observations to Benefit the Environment (GLOBE) Program were matched with MODIS satellite overpasses and geostationary cloud fraction, yielding a dataset of coincident observations for comparison with hourly model output. The observations indicate a model bias toward overcast and clear conditions, with underestimation of intermediate cloud fractions. We investigate underestimation of variance in the sub-grid total water probability density function (PDF) as a possible cause. The PDF determines large-scale cloud fraction as the sub-grid fraction with total water exceeding the saturation specific humidity. We conduct model experiments in which the shape, width, and spatial dependence of the PDF are varied, and consider the impacts on cloud fraction relative to the combined observations.

Starke, Matthew↗

Microphysical modeling of cirrus. 2: Sensitivity studies

The one-dimensional cirrus model described in part 1 of this issue has been used to study the sensitivity of simulated cirrus microphysical and radiative properties to poorly known model parameters, poorly understood physical processes, and environmental conditions. Model parameters and physical processes investigated include nucleation rate, mode of nucleation (e.g., homogeneous freezing of aerosols and liquid droplets or heterogeneous deposition), ice crystal shape, and coagulation. These studies suggest that the leading sources of uncertainty in the model are the phase change (liquid-solid) energy barrier and the ice-water surface energy which dominate the homogeneous freezing nucleation rate and the coagulation sticking efficiency at low temperatures which controls the production of large ice crystals (radii greater than 100 mcirons). Environmental conditions considered in sensitivity tests were CN size distribution, vertical wind speed, and cloud height. We found that (unlike stratus clouds) variations in the total number of condensation nuclei (NC) have little effect on cirrus microphysical and radiative properties, since nucleation occurs only on the largest CN at the tail of the size distribution. The total number of ice crystals which nucleate has little or no relationship to the number of CN present and depends primarily on the temperature and the cooling rate. Stronger updrafts (more rapid cooling) generate higher ice number densities, ice water content, cloud optical depth, and net radiative forcing. Increasing the height of the clouds in the model leads to an increase in ice number density, a decrease in effective radius, and a decrease in ice water content. The most prominent effect of increasing cloud height was a rapid increase in the net cloud radiative forcing which can be attributed to the change in cloud temperature as well as change in cloud ice size distributions. It has long been recognized that changes in cloud height or cloud area have the greatest potential for causing feedbacks on climate change. Our results suggest that variations in vertical velocity or cloud microphysical changes associatd with cloud height changes may also be important.

Jensen, Eric J.↗

Water Uptake by Silica Nanopores: Impacts of Surface Hydrophilicity and Pore Size

Water uptake at 298 K by two mesoporous silicas with different pore sizes was studied using volumetric vapor sorption. Here, through variation of sample pretreatment temperature and time, the number of surface hydroxyl groups was varied, leading to marked changes in the water sorption behavior. With increasing surface hydroxyl density, the adsorption of water to the pore surfaces increases, leading to formation of a thicker and denser water sorption layer. The BET model was used to measure surface hydroxyl density from low pressure parts of water adsorption isotherms. Adsorption of water molecules scales with the number density of surface hydroxyl groups, and monolayer coverage is reached at reduced pressure of ca. 0.3. The onset of adsorption pore condensation of water shifts to lower reduced pressure with increasing surface hydroxyl density, indicating growing thickness of adsorption layers. However, the water pore condensation step of the desorption branch shifts to smaller reduced pressure with increasing surface hydroxylation, reducing the adsorption-desorption hysteresis width. An adsorbed phase model is utilized to calculate the distribution of pore water molecules between adsorbed and pore condensation phases, and characterize the density and thickness of the water sorption phase. In the smaller pores, the adsorbed phase forms a sparse monolayer, while approximately a bilayer is formed in the wider pores. The previously reported silica nanopore underfilling by water is confirmed and rationalized by a significantly reduced water density in the adsorbed phase with respect to bulk, while the pore core is filled with water of approximately bulk density.

36 MATERIALS SCIENCE↗

Gravity receptors in a microcrustacean water flea - Sensitivity of antennal-socket setae in Daphnia magna

Gravity receptors of Dephnia magna were discovered on the basal segment of the swimming antennae and were shown to respond to upward water currents that pass the animal as it sinks between swimming strokes. Sensitivity of the gravity perceiving mechanism was tested by subjecting daphnids to a series of five decreasingly dense aqueous solutions (neutral density to water) in darkness (to avoid visual cues). Three-dimensional, video analysis of body position (pitch, yaw and roll) and swimming path (hop and sink, vertical and horizontal patterns) revealed a gradual threshold that occurred near a density difference between the animal and its environment of less than 0.25%. Because daphnids do not sink but continue to slide after stroking in the increased density solutions, gravity perception appears to occur during a vertical swing of the longitudinal body axis to the vertical plane, about their center of gravity, and, thereby, implies a multidirectional sensitivity for the antennal-socket setae.

Meyers, D. G.↗

Adaptive Sampling for In Situ Cloud Probe (Final Report)

Clouds play a leading role in the Earth's global energy and solar radiation balance and hydrological cycle. Improving cloud models requires detailed information on the cloud microphysical properties, such as droplet size distribution and number density, liquid water content and cloud composition (droplets, ice particles), which can only be provided by aerial in situ measurements. However, for many atmospheric measurement instruments, the lack of flexibility in selecting the operational mode during operation can lead to uncertainties in sampling and measurement characteristics under continuously varying atmospheric conditions. This SBIR project is developing an advanced, compact optical imaging technology for in situ characterization of cloud hydrometeors. The development involves a deep modification of the existing Mesa Photonics’ Cloud Droplet Measurement System (CDMS) in order to implement real-time automatic adaptive sampling based on the acquired in situ data and environmental parameters. The new system, CDMS-2, implements two measurement modes: side-scatter imaging for smaller hydrometeors and direct bright-field-illumination imaging for larger hydrometeors in a significantly larger sample volume. The system measures the droplet size distribution (DSD) and number density with an added capability of discriminating between liquid water and ice hydrometeors (based on polarization-resolved side-scatter imaging). The instrument will implement automatic switching or alternating between the regular side-scatter imaging mode and sparse/large hydrometeor mode (based on the acquired data). Other adaptive sampling capabilities include variable sample volume and dynamic range (based on the measured DSD). The preferred deployment platforms are uncrewed aircraft systems (UAS) and tethered balloon/kite systems (TBS). The Phase I project achieved (or exceeded) the goals listed in the Work Plan. A CDMS-2 laboratory prototype implementing the polarization-resolved side-scatter imaging mode and direct bright-field-illumination imaging mode was designed and built. Additional capabilities included the variable illumination pulse energy and sample volume. The smallest detectable droplet diameter was improved to 3–4 μm (from the nominal 10 μm value specified for the original CDMS). Discrimination between water droplets and ice particles was experimentally demonstrated. The Phase I prototype was extensively tested and calibrated in the laboratory and also tested in the Pi Cloud Chamber at Michigan Technological University (MTU). The two intensive experimental campaigns at MTU provided unique opportunities of testing the CDMS-2 laboratory prototype under realistic warm and mixed-phase cloud conditions (stable for long periods of time), testing different sampling modes and intercomparing the CDMS-2 prototype to other co-located cloud characterization instruments. The Phase I project successfully demonstrated the feasibility of the proposed technology and identified the engineering challenges of designing a field deployable prototype instrument in Phase II. The Phase I study provides a solid basis for development, characterization and field-testing of the proposed advanced cloud probe with adaptive sampling in Phase II followed by commercialization of the technology in Phase III.

47 OTHER INSTRUMENTATION↗

Electrospraying for Precision Delivery of Water and Nutrients for Aeroponics in Microgravity

Developed an enclosure with a custom high voltage nozzle that electrosprays wire "roots" with milliliters (mL) of water in real time by measuring the charge sprayed onto the roots. It uses the spray’s charge to mass from previous measurements with the same nozzle (and the density of water) to convert the display to volume. To deliver water to the nozzle consistently and programmatically, the syringe pump performed the best for experiments because the diaphragm pump created a stuttered flow and the pressurized reservoir’s pressure controller was more complex than the syringe pump’s commercial LabVIEW software that direct controls flow rate.

Joel D Malissa↗

The Role of Nonequilibrium Solvent Effects in Enhancing Direct CO 2 Capture at the Air–Aqueous Amino Acid Interface

Direct air capture (DAC) technologies are limited by the poor understanding of the dynamic role of interfaces in modulating the chemisorption of CO 2 from air into solutions. While the reactivity of aqueous amine-based solvents in the bulk environment is strongly inhibited by nonequilibrium solvent effects, promoting DAC at interfaces posits a possibility to reduce the coupling with the solvent and significantly accelerate DAC. Building on an experimentally proven concept to bring an anionic glycine absorbent to the interface through ion-pairing interactions with a positively charged surfactant, we establish the fundamental time scales for key elementary steps involved in DAC with rate theory and enhanced-sampling ab initio molecular dynamics simulations. Here, we elucidate the mechanism by which water influences the free energy barriers and dynamical crossing-recrossing of those barriers, affecting the reaction rates. We find that water reorganizes to partially dehydrate [-NH 2 ], facilitating S N 2-based CO 2 conversion to a zwitterion, which then releases a proton via overhydration of [-NH 2 ]. The low-density interfacial water favors dehydration over overhydration, leading to a comparatively higher barrier (slower kinetics) for proton release. The barrier-recrossing events neutralize this effect, letting both steps occur at the same time scale (sub-microseconds) and making the overall DAC process faster at the interface than in the bulk water. Such an understanding of environment-sensitive solvent effects on the reaction kinetics will help design tailored interfaces for enhanced CO 2 capture kinetics via control of solvation and ion paring.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen Bonds and H 3 O + Formation at the Water Interface with Formic Acid Covered Anatase TiO 2

Carboxylic acid-modified TiO 2 surfaces in aqueous environment are of widespread interest, yet atomic-scale understanding of their structure is limited. In this work, we investigate formic acid (FA) on anatase TiO 2 (101) (A-101) in contact with water using density functional theory (DFT) and ab-initio molecular dynamics (AIMD). Isolated FA molecules adsorbed in a deprotonated bridging bidentate (BD) form on A-101 are found to remain stable at the interface with water, with the acid proton transferred to a surface oxygen to form a surface bridging hydroxyl (O br H). With increasing FA coverage, adsorbed monolayers of only BD and successively of alternating monodentate (MD) and BD species give rise to a higher concentration of surface O br H’s. Simulations of these adsorbed monolayers in water environment show that some protons are released from the surface O br H’s to water resulting in a negatively charged surface with nearby solvated H 3 O + ions. These results provide insight into the complex acid-base equilibrium between an oxide surface, adsorbates and water and can also help obtain a better understanding of the wetting properties of chemically modified TiO 2 surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗