At least 109 records · Page 6

Water system microbial check valve development

A residual iodine microbial check valve (RIMCV) assembly was developed and tested. The assembly is designed to be used in the space shuttle potable water system. The RIMCV is based on an anion exchange resin that is supersaturated with an iodine solution. This system causes a residual to be present in the effluent water which provides continuing bactericidal action. A flight prototype design was finalized and five units were manufactured and delivered.

Colombo, G. V.↗

A hot-water system tested onsite--Togus, Maine

Performance close to design specifications was verified over one year study in solar hot-water system. Study looked at long-term operation of system installed in residential building in Togus, Maine.

Source record↗

History, Current Operations and Management of Water Systems on the International Space Station

In November 2000, the Expedition 1 crew to the International Space Station (ISS) arrived onboard, thus beginning a 19+ year need to provide potable water to the crew, as well as water to key life support systems. For the first 8 years of ISS operations, the water systems' operations were relatively simple. It consisted of manifesting water via cargo ships or generated via the Space Shuttle fuel cells and stored on ISS to supplement the water processing systems on the Russian segment of the ISS. In 2008, the Water Processor Assembly (WPA), Urine Processor Assembly (UPA), along with a U.S. provided toilet arrived onboard, supplementing the Oxygen Generator Assembly (OGA). This new equipment, known as Regen ECLSS (Regenerative Environmental Control and Life Support Systems), provided a significant capability in recycling fluid within the ISS and minimized manifestation needs. Early in the operations of the Regen ECLSS system, it became clear that the tank capacities were under sized. This led to excessive use of costly crew time to perform water operations. In 2012, a group of ISS flight controllers and engineers proposed and developed a new system that would provide integrated water tanks that could be fully operated from Mission Control on the ground to move water around within the systems. This system has very recently been installed on the ISS and commissioning operations have occurred. This paper will provide a general history of water operations on the ISS, as new systems arrived, and new operations were required. Challenges with water balance, to both avoid overfilling the system as well as avoid running out of water, will be discussed, along with touching on the convoluted steps the Flight Control team had to perform daily to predict future water needs. Finally, the new water storage system will be discussed and the benefits it brings to ISS water operations.

Christopher A Brown↗

Design of a surface-based factory for the production of life support and technology support products. Phase 2: Integrated water system for a space colony

Phase 2 of a conceptual design of an integrated water treatment system to support a space colony is presented. This includes a breathable air manufacturing system, a means of drilling for underground water, and storage of water for future use. The system is to supply quality water for biological consumption, farming, residential and industrial use and the water source is assumed to be artesian or subsurface and on Mars. Design criteria and major assumptions are itemized. A general block diagram of the expected treatment system is provided. The design capacity of the system is discussed, including a summary of potential users and the level of treatment required; and, finally, various treatment technologies are described.

Source record↗

Largo hot water system long range thermal performance test report, addendum

The test procedure used and the test results obtained during the long range thermal performance tests of the LARGO Solar Hot Water System under natural environmental conditions are presented. Objectives of these tests were to determine the amount of energy collected, the amount of power required for system operation, system efficiency, temperature distribution, and system performance degradation.

Source record↗

Study to Optimize Gellant Polymer-Water Systems for the Control of Hypergolic Spills and Fires

A system of buffered gelled water was developed to prevent and control fires from small spills of nitrogen tetroxide-(N2O4)-Aerozine 50-hypergolic fuel. Laboratory studies on various alkalis, buffers, and seavengers for the fuel components are described. Chilling and sodium acetate-acetic acid buffer was found to be the best additives to the gelled water. Field tests and a delivery system (airborne) for the extinguishant are described.

Jennings, R. R.↗

G-189A analytical simulation of the integrated waste management-water system using radioisotopes for thermal energy

An analytical simulation of the RITE-Integrated Waste Management and Water Recovery System using radioisotopes for thermal energy was prepared for the NASA-Manned Space Flight Center (MSFC). The RITE system is the most advanced concept water-waste management system currently under development and has undergone extended duration testing. It has the capability of disposing of nearly all spacecraft wastes including feces and trash and of recovering water from usual waste water sources: urine, condensate, wash water, etc. All of the process heat normally used in the system is produced from low penalty radioisotope heat sources. The analytical simulation was developed with the G189A computer program. The objective of the simulation was to obtain an analytical simulation which can be used to (1) evaluate the current RITE system steady state and transient performance during normal operating conditions, and also during off normal operating conditions including failure modes; and (2) evaluate the effects of variations in component design parameters and vehicle interface parameters on system performance.

Coggi, J. V.↗

Air and Water System (AWS) Design and Technology Selection for the Vision for Space Exploration

This paper considers technology selection for the crew air and water recycling systems to be used in long duration human space exploration. The specific objectives are to identify the most probable air and water technologies for the vision for space exploration and to identify the alternate technologies that might be developed. The approach is to conduct a preliminary first cut systems engineering analysis, beginning with the Air and Water System (AWS) requirements and the system mass balance, and then define the functional architecture, review the International Space Station (ISS) technologies, and discuss alternate technologies. The life support requirements for air and water are well known. The results of the mass flow and mass balance analysis help define the system architectural concept. The AWS includes five subsystems: Oxygen Supply, Condensate Purification, Urine Purification, Hygiene Water Purification, and Clothes Wash Purification. AWS technologies have been evaluated in the life support design for ISS node 3, and in earlier space station design studies, in proposals for the upgrade or evolution of the space station, and in studies of potential lunar or Mars missions. The leading candidate technologies for the vision for space exploration are those planned for Node 3 of the ISS. The ISS life support was designed to utilize Space Station Freedom (SSF) hardware to the maximum extent possible. The SSF final technology selection process, criteria, and results are discussed. Would it be cost-effective for the vision for space exploration to develop alternate technology? This paper will examine this and other questions associated with AWS design and technology selection.

Jones, Harry↗

Residential solar hot water system--Tempe, Arizona

Domestic hot water for single story home is heated by two 4 by 8 foot solar collectors. Solar energy saved 5.54 million Btu in six month period; savings with increased water consumption would be significantly higher.

Source record↗

Updated Analysis of the Trash Compaction and Processing System: Water Collected from Trash, Evaluation of the Source Contaminant Control System, and Zotek® F30 Foam Processing

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). At NASA Ames Research Center (ARC), there are two test systems: the Heat Melt Compactor (HMC), which compacts the trash into a tile with temperature and pressure, and the Source Contaminant Control System (SCCS), which is the gas management subsystem aimed to reduce contaminants by converting them into carbon dioxide (CO 2 ) and water (H 2 O) vapor. Both the HMC and SCCS serve as test systems that support TCPS development by conducting risk reduction activities associated with an ISS technology demonstration. In this paper, the risk reduction activities discussed are the testing of different trash models for operational scenarios in the HMC, investigating the water extracted from those trash models, and managing the gaseous effluents from the trash via contaminant conversion through the SCCS. The HMC has undergone several tests of different trash models and cases in which a containment bag is used or not. For the first topic, this paper will analyze the water collected and recovered from these tests and analyze the effect of specific trash containment bags. For the second topic, this paper will individually evaluate the carbon bed and catalytic oxidizer (CatOx) to understand what components the carbon bed removes and what contaminants are converted in the CatOx. For the third and final topic, this paper will discuss Zotek® F30 foam processing in the HMC unit and testing verification in correlation to defined TCPS requirements. A foam model was added to reduce the volume of foam that take up space in the ISS. Overall, this paper is a compilation and an updated analysis of tests conducted in the lab-scale TCPS at ARC within the past year.

TCPS↗

An Active Subglacial Water System in West Antarctica Mapped from Space

Satellite laser altimeter elevation profiles from 2003 to 2006 collected over the lower parts of Whillans and Mercer ice streams, West Antarctica, reveal 14 regions of temporally varying elevation, which we interpret as the surface expression of subglacial water movement. Vertical motion and spatial extent of two of the largest regions are confirmed by satellite image differencing. A major, previously unknown subglacial lake near the grounding line of Whillans Ice Stream is obse~edto drain 2.0 cubic kilometers of water into the ocean over approx.3 years, while elsewhere a similar volume of water is being stored subglacially. These observations reveal a widespread, dynamic subglacial water system that may exert an important control on ice flow and mass balance.

Fricker, Helen Amanda↗

Solar heating and domestic hot water system installed at North Dallas High School

The solar energy system located at the North Dallas High School, Dallas, Texas is discussed. The system is designed as a retrofit in a three story with basement, concrete frame high school building. Extracts from the site files, specification references for solar modification to existing building heating and domestic hot water systems, drawings, installation, operation and maintenance instructions are included.

Source record↗

Water system virus detection

A monitoring system developed to test the capability of a water recovery system to reject the passage of viruses into the recovered water is described. A nonpathogenic marker virus, bacteriophage F2, is fed into the process stream before the recovery unit and the reclaimed water is assayed for its presence. Detection of the marker virus consists of two major components, concentration and isolation of the marker virus, and detection of the marker virus. The concentration system involves adsorption of virus to cellulose acetate filters in the presence of trivalent cations and low pH with subsequent desorption of the virus using volumes of high pH buffer. The detection of the virus is performed by a passive immune agglutination test utilizing specially prepared polystyrene particles. An engineering preliminary design was performed as a parallel effort to the laboratory development of the marker virus test system. Engineering schematics and drawings of a fully functional laboratory prototype capable of zero-G operation are presented. The instrument consists of reagent pump/metering system, reagent storage containers, a filter concentrator, an incubation/detector system, and an electronic readout and control system.

Fraser, A. S.↗

The magnesium sulfate-water system at pressures to 4 kilobars

Hydrated magnesium sulfate constitutes up to 1/6 of the mass of carbonaceous chondrites, and probably is important in many icy asteroids and satellites. It occurs naturally in meteorites mostly as epsomite. MgSO4, considered anhydrously, comprises nearly 3/4 of the highly soluble fraction of C1 chondrites. Thus, MgSO4 is probably an important solute in cryovolcanic brines erupted on certain icy objects in the outer solar system. While the physiochemical properties of the water-magnesium sulfate system are well known at low pressures, planetological applications of these data are hindered by a dearth of useful published data at elevated pressures. Accordingly, solid-liquid phase equilibria was recently explored in this chemical system at pressures extending to about 4 kilobars. The water magnesium sulfate system in the region of the eutectic exhibits qualitatively constant behavior between pressures of 1 atm and 2 kbar. The eutectic melting curve closely follows that for water ice, with a freezing point depression of about 4 K at 1 atm decreasing to around 3.3 K at 2 kbars. The eutectic shifts from 17 pct. MgSO4 at 1 atm to about 15.3 pct at 2 kbars. Above 2 kbars, the eutectic melting curve again tends to follow ice.

Hogenboom, D. L.↗

Motel solar-hot-water system with nonpressurized storage--Jacksonville, Florida

Modular roof-mounted copper-plated arrays collect solar energy; heated water drains from them into 1,000 gallon nonpressurized storage tank which supplies energy to existing pressurized motel hot water lines. System provides 65 percent of hot water demand. Report described systems parts and operation, maintenance, and performance and provides warranty information.

Source record↗