Search NASA⌕ Search

SEARCH · Search NASA

Results for “wave energy converter testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

TEAMER - AquaHarmonics High Fidelity WEC Sim PTO and Control Model Validation, Test Logs and Results

Collaborative effort between AquaHarmonics, Sandia National Laboratories (SNL), and the National Renewable Energy Laboratory (NREL) to revise and validate Aquaharmonics' full wave to wire model, allowing for reduced uncertainty and increased understanding of design requirements of a utility scale wave energy converter (WEC). SNL and NREL in collaboration with AquaHarmonics, will set up and run WEC Simulator (WEC-Sim) models of the AquaHarmonics WEC, building off past model developments for inclusion of custom PTO (power take-off) dynamics. The intent is to review, update, and verify or validate a new WEC-Sim model against wave tank experimental data. Furthermore, the WEC-Sim model will be coupled to an energy storage system model to better understand the wave-to-wire functionality. This data set is described in the "Test Log" excel file. Please refer to that document for details on each specific test date/time, constraint parameters and model hardware setup details. Sim model can be found in the associated MHKDR link below.

16 TIDAL AND WAVE POWER↗

Tidal Turbine Test, Downeast Turbines, July 12, 2021

Downeast Turbines tested a tidal turbine prototype with novel rotor/channel system and lateral effluent discharge apparatus (LEDA), during five days of testing in the flume at Alden Lab. Three days of testing (July 12-14, 2021) focused on turbine power metrics of torque and rpm, which were low, and then two days of follow-up testing (July 27-28, 2021) focused on LEDA performance metrics of pressure differential and rates of volumetric flow, with encouraging results. Next step is to to characterize, and even optimize, configurations of the LEDA, using 3D-CFD as a helpful tool, to refine its shape and explore its limits of performance as a means of effluent discharge that augments performance of an instream turbine. An improved configuration of the LEDA will be re-combined with the rotor/channel system of the turbine prototype, and ultimately, the rotor will be re-sized (enlarged), to better match the LEDA's performance capabilities in drawing through a rate of volumetric flow. This submission is Downeast Turbines' Post Access Report for the test event. It includes the files described here (next below), and several reference links. "Downeast TEAMER-Post-Access-Report...docx" is a document file containing the report. "Appendices A, B, and C" are included in this file, and so are "Figures #1-7." "Appendix D - Test Data Workbooks.zip" is an archive file containing all post access data (raw data tables, calculating tables, and graphs), presented in fourteen Excel workbooks as described in the report. "Appendix E - Post Access Figures.zip" is an archive file containing "Figures #8-52," of the report.

16 TIDAL AND WAVE POWER↗

Design of High-Deflection Foils MHK Applications - FEA models

The Ocean Renewable Power Company's (ORPC's) goal is to design, develop, and test hydrofoils with large deflections. The effects of the deflections on cross-flow turbine performance would be evaluated in order to inform design considerations for full-scale water turbines and other marine hydrokinetic devices. Finite element models - NASTRAN files Model scale turbines tested in UNH tow tank Model loads from CFD models

16 TIDAL AND WAVE POWER↗

Prototyping of a Rotary Triboelectric Nanogenerator for Power at Sea

Increasing at-sea power generation by Triboelectric Nanogenerator (TENG) energy harvesters towards the order of 1-Watt will create significant opportunities to power ocean observation buoys and distributed sensor nodes by extending mission time and increasing sensor payload. Of the many possible configurations of harvesting wave energy with TENGs, we document the rationale for choosing and developing a rotary TENG that operates by the freestanding mode. The rotary TENG prototype consists of two plates, a rotor and a stator, to take advantage of the various mechanisms of converting wave action into rotational motion. We have constructed a testing apparatus that allows us to vary several key parameters of the device: distance between rotor and stator, triboelectric material, rotational speed, number of electrodes and output load impedance. Preliminary results show that when driven at a constant 500 rpm, we can achieve a power density of 0.7 W/m3. A variable speed motor drives the rotor, which can be driven using a velocity profile informed by the equivalent to the output from a wave energy converter (WEC). The optimized rotational TENG can be stacked and driven by a single shaft, increasing the energy density of the device. The output of such a TENG could be used to power devices in the ocean at a low cost and high durability.

electrostatic generator↗

Linking international technical specifications for acoustic characterization of marine energy converter sounds with environmental compliance criteria

As new ocean energy technologies emerge and are deployed for testing and operations, sound emissions are a potential concern for environmental effects to marine life. Consistent acoustic measurement and data analysis methods can help promote comparisons of technologies and transferability between project sites. In 2022, acoustic emissions from a prototype scale wave energy converter (WEC) were characterized for a range of environmental conditions and power generation states in the coastal waters off southern California using a set of international technical specifications. Results from the international technical specification analyses were applied to United States regulatory threshold criteria for acoustic impacts to marine mammals and examined in the context of European underwater noise monitoring guidelines. Weighted 24 hour cumulative sound exposure levels SEL24h calculated from the highest power generation state WEC sound pressure levels were often more than 20 dB below threshold criteria for temporary threshold shifts in five relevant marine mammal hearing groups. Following European Union recommendations for analyses and reporting, WEC sound characterization in third octave bands centered at 63 Hz and 125 Hz show clear spatial decay of WEC-generated noise, with more pronounced attenuation at 63 Hz, and a less marked but still detectable gradient at 125 Hz, collectively suggesting a relatively confined acoustic footprint under the observed conditions. The value of the international technical specification approach is highlighted by the isolation of WEC sounds from the surrounding soundscape. This allows for a robust characterization of acoustic emissions through a range of device power generation and sea states. Furthermore, in threshold-based regulatory contexts like the U.S., this facilitates direct evaluation of source contributions, while in broader monitoring frameworks used in the E.U. it provides a reproducible foundation for assessing the contribution of emerging ocean energy technologies to the underwater acoustic environment.

Haxel, Joseph H. (ORCID:0000000273864761)↗

UMass 2-Body WEC Techno-Economic Assessment

The University of Massachusetts (UMass) is developing a 2-body wave energy converter (WEC) device that is converting mechanical power into electricity using a mechanical motion rectifier that allows the system to couple to a flywheel. UMass has completed numerical modeling, wave tank testing, and PTO sub-system testing and needed assistance in developing a techno-economic model to enable optimization of their topology, comparison to a generic heaving point absorber topology, and guide the next steps in their development efforts. The core objective was to develop a techno-economic approach and modeling tool that allows benchmarking of the two topologies across a wide range of scales to evaluate their respective competitiveness in different application spaces. This data includes the final report as well as a supporting spreadsheet containing the data produced for this report.

16 TIDAL AND WAVE POWER↗

TEAMER: DAISY Flow-noise Testing (Abstract)

Evaluating impacts of marine energy devices is generally difficult given the dynamic environment where these devices need to be placed. The University of Washington’s (UW) DAISY (The Drifting Acoustic Instrumentation SYstem) is designed to measure radiated noise around marine energy converters operating in energetic waves and currents. In currents, a primary limitation for measurement fidelity at low frequencies (< 100 Hz) is the potential for non-propagating “flow-noise” to mask propagating sound and inflate estimates of the radiated noise from marine energy converters at frequencies that overlap with hearing sensitivities of fish and some marine mammals. While free-drifting measurements help to minimize the relative velocity that produces flow-noise, significant levels were still observed during initial DAISY tests. This motivated the development of a fabric “flow shield” around the hydrophone that disrupts both flow-noise generation mechanisms proposed by the initial tests. First, the flow shield is a source of substantial drag which keeps the hydrophone package moving with the approximate velocity of the surrounding water, compensating for differential wind or current forcing on the surface expression. By minimizing relative velocity around the hydrophone, turbulence shed by the hydrophone is also minimized. Second, the flow shield creates a largely quiescent pocket around the hydrophone, minimizing advection of free stream turbulence over the hydrophone element. Field data collected in these experiments will test effectiveness of these flow shields and provide quantitative data use and deployment.

16 TIDAL AND WAVE POWER↗

Experimental Validation of a Modular All-Electric Power Take-Off Topology for Wave Energy Converter Enabling Marine Renewable Energy Interconnection

Power electronic converters are an enabling technology for the emerging marine energy applications, such as using ocean waves to produce electricity. This paper outlines the power take-off system and its key components used in a wave energy converter offering modularity and scalability to generate power efficiently. The proposed power take-off system was implemented based on a modular multilevel converter and could be deployed to convert any alternating current electrical energy to a different alternating current for interconnection to grid or non-grid applications. Examples of widespread deployment are supplying electricity to coastal communities or producing clean drinking water. The analysis using both the simulation tests and laboratory experiments verified the design objectives and basic functionality of the developed power take-off system. An acceptable response using a field programmable gate array-based controlled laboratory testbench was achieved, complying with guidelines specified in the prevalent industry standards. Seamless operation during steady-state and transients for the studied wave energy converter was achieved as supported by the obtained results. The key findings of this work were experimentally examined under different load conditions, direct current bus voltage fluctuations, and generator speed–torque regulation. The ability of the power take-off system to generate high-power quality of the waveforms, e.g., against adhering to the IEEE 519-2022 standard for total harmonic distortion limits, is also confirmed.

Engineering↗

Initial testing of wave energy powered UV-C LED anti-biofouling system (CRADA 523)

3newable is requesting technical assistance for laboratory testing at the Marine and Coastal Research (MCRL) Laboratory of a UV-C LED anti-biofouling system. Ocean observing sensors provide critical data sources from deployed buoys and other platforms at sea. However, in addition to the availability of reliable power sources, biofouling of sensors and instruments is a limiting factor for operation and maintenance of deployed instruments. In collaboration with the Woods Hole Oceanographic Institute Ocean Observatories Initiative, 3newable has developed a novel solution to overcome these challenges and extend the deployment period of buoy-mounted sensors. The 3newable system co-locates wave energy converters to supply UV-C LED anti-biofouling units on powered buoy arrays. MCRL staff will implement an experiment to evaluate the efficacy of 3newable’s device under test for inhibiting growth of organisms on test coupons in a flow through seawater tank.

42 ENGINEERING↗

Use of a 360-Degree Underwater Camera to Characterize Artificial Reef and Fish Aggregating Effects around Marine Energy Devices

Marine energy devices must be attached to the seafloor by their foundations, pilings, or anchors, and will have other parts in the water column like the devices themselves, mooring lines, and power export cables running along the seafloor. The installation and presence of these artificial structures will create physical changes that can disrupt or create new habitats, and potentially alter the behavior of mobile organisms such as fish around a device by attracting them to these new artificial reefs and fish aggregating devices. In this study, we tested a new approach for monitoring fish activity around a marine energy device anchor: a 360-degree underwater camera to keep the target (a wave energy converter’s anchor) in the field of view of the camera. The camera was deployed in three configurations (hand-held, tripod, video lander) at sites with different hydrodynamics and underwater visibilities. The video lander was the best configuration: very stable, versatile, and easy to handle. The 360-degree field of view enabled observing and counting fishes, which were more abundant at dusk than dawn or noon, around the anchor. Despite remaining challenges, 360-degree cameras are useful tools for monitoring animal interactions with marine energy devices.

360-degree camera↗

HERO WEC 2024 Hydraulic Configuration Deployment Data

The following submission includes raw and processed data from the in water deployment of NREL's Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC), in the form of parquet files, TDMS files, CSV files, bag files and MATLAB workspaces. This dataset was collected in March 2024 at the Jennette's pier test site in North Carolina. This submission includes the following: - Data description document (HERO WEC FY24 Hydraulic Deployment Data Descriptions.doc) - This document includes detailed descriptions of the type of data and how it was processed and/or calculated. - Processed MATLAB workspace - The processed data is provided in the form of a single MATLAB workspace containing data from the full deployment. This workspace contains data from all sensors down sampled to 10 Hz along with all array Value Added Products (VAPs). - MATLAB visualization scripts - The MATLAB workspaces can be visualized using the file "HERO_WEC_2024_Hydraulic_Config_Data_Viewer.m/mlx". The user simply needs to download the processed MATLAB workspaces, specify the desired start and end times and run this file. Both the .m and .mlx file format has been provided depending on the user's preference. - Summary Data - The fully processed data was used to create a summary data set with averages and important calculations performed on 30-minute intervals to align with the intervals of wave resource data reported from nearby CDIP ocean observing buoys located 20km East of Jennette's pier and 40km Northeast of Jennette's pier. The wave resource data provided in this data set is to be used for reference only due the difference in water depth and proximity to shore between the Jennette's pier test site and the locations of the ocean observing buoys. This data is provided in the Summary Data zip folder, which includes this data set in the form of a MATLAB workspace, parquet file, and excel spreadsheet. - Processed Parquet File - The processed data is provided in the form of a single parquet file containing data from all HERO WEC sensors collected during the full deployment. Data in these files has been down sampled to 10 Hz and all array VAPs are included. - Interim Filtered Data - Raw data from each sensor group partitioned into 30-minute parquet files. These files are outputs from an intermediate stage of data processing and contain the raw data with no Quality Control (QC) or calculations performed in a format that is easier to use than the raw data. - Raw Data - Raw, unprocessed data from this deployment can be found in the Raw Data zip folder. This data is provided in the form of TDMS, CSV, and bag files in the original format output by the MODAQ system. - Python Data Processing Script - This links to an NREL public github repository containing the python script used to go from raw data to fully processed parquet files. Additional documentation on how to use this script is included in the github repository. This data set has been developed by the National Renewable Energy Laboratory, operated by Alliance for Sustainable Energy, LLC, for the U.S. Department of Energy (DOE) under Contract No. DE-AC36-08GO28308. Funding provided by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office.

16 TIDAL AND WAVE POWER↗

Wave-powered water pump for upwelling in aquaculture: Numerical model and ocean test

Wave-powered upwelling can increase the productivity and survivability of several aquaculture species. This enhancement is due to transporting cold, nutrient-rich ocean water, typically found lower in the water column, to the surface. Macroalgaes, like kelp, exhibit increased growth from these altered conditions. The University of New Hampshire’s (UNH) wave-powered water pump (wave pump) is a point absorber wave energy converter (WEC) that uses ocean waves to create relative motion between a spar buoy and a concentric float which drives an internal pump. A numerical model of the wave pump was developed using WEC-Sim to predict device performance in the ocean. Wave pump performance was evaluated during a five day ocean test near Appledore Island in Maine in March 2023, where volumetric flow rate, relative distance between spar and float, and wave conditions were measured. These data were then used for numerical model validation. The ocean deployment recorded the device’s performance in a variety of sea states, with average significant wave heights up to 0.7 m. The ocean test data were compared to the WEC-Sim numerical model of the device with favorable results. Average values of device stroke period, stroke height, and flow rate agreed between the ocean test and model data to within approximately 16 to 22%. Furthermore, the validated numerical model provides a valuable tool for improving the design and developing a commercial-scale, wave-powered water pump for use in aquaculture.

16 TIDAL AND WAVE POWER↗

HERO WEC 2024 - Electrical Configuration Deployment Data

The following submission includes raw and processed electrical configuration deployment data from the in water deployment of NREL's Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC), in the form of parquet files, TDMS files, CSV files, bag files, and MATLAB workspaces. This dataset was collected in April 2024 at the Jennette's pier test site in North Carolina. Raw data as TDMS, CSV, and bag files are provided here alongside processed data in the form of MATLAB workspaces and Parquet files. This dataset includes the Python code used to process the data and MATLAB scripts to visualize the processed data. All data types, calculations, and processing is described in the included "Data Descriptions" document. All files in this dataset are described in detail in the included README. This data set has been developed by the National Renewable Energy Laboratory, operated by Alliance for Sustainable Energy, LLC, for the U.S. Department of Energy (DOE) under Contract No. DE-AC36-08GO28308. Funding provided by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office.

16 TIDAL AND WAVE POWER↗

Optimal Control of an Oscillating Surge Wave Energy Converter

During this project, we experimentally investigated the hydrodynamics and performance of a laboratory-scale oscillating surge wave energy converter (OSWEC).We looked at how flap buoyancy and driveline losses (primarily in the form of stiction) affected the dynamics and performance of the device. In addition, we assessed the influence of flap profile (rounded vs. square edges) on OSWEC hydrodynamics. Through this, we were able to develop a deeper understanding of OSWEC performance and provide guidance on strategies to counteract artifacts that may be present in laboratory models, but are absent in field-scale devices. To do this, we tested a laboratory-scale OSWEC in the Sea Wave Environmental Lab (SWEL) wave tank at the National Renewable Energy Laboratory (NREL). We ran several types of experiments to investigate the hydrodynamics and performance of the device. Overall, we achieved the overall goal of experimentally investigating the hydrodynamics and performance of this device. We discovered important and unexpected trends in performance, and collected time-resolved data to help us further investigate the underlying hydrodynamics responsible for these trends. In addition, we are currently using the time-resolved data from these experiments to build data-driven models of the dynamics, which can in turn be used to inform data-driven model predictive control of this device and address this objective in the future.

16 TIDAL AND WAVE POWER↗

RITE Gen5 KHPS Performance - Period B

Includes Kinetic Hydropower System (KHPS) Turbine performance data from the RITE Gen5 KHPS turbine at the 5 meter size. This data was collected over 16 days in May 2021 during Period B operation. Along with performance data, the data includes setup data, project metadata, and characteristic data for RITE Gen5 KHPS (5m) turbine.

16 TIDAL AND WAVE POWER↗

TEAMER: Results of Investigating Structural Design Concepts and Alternative Materials for a Wave Power System

Included here are materials from a study on the design of a three-body Wave Energy Converter (WEC) utilizing a heave plate, dual Power Take Offs (PTOs), and single point mooring. A material trade study has been conducted to evaluate the effects of introducing various metallic and fiber-reinforced polymer (FRP) elements to the design. The baseline design is C-Power's patented k2 Wave Power System (WPS). This Testing Expertise and Access for Marine Energy Research (TEAMER) Request for Technical Support (RFTS) 9 effort resulted in alternative designs of the WPS center member, the nacelle. The analysis resulting from this study will inform the design of a lightweight structure with lower manufacturing and operating costs that increases energy conversion and power-to-weight ratio of the device. The dataset contains several components: finite element analysis (FEA) data, hand calculations, and CAD models. FEA files includes those used for and generated by finite element simulations. Calculations include hand calculations performed using Microsoft Excel, which assess core laminate properties, buckling, and other structural aspects in accordance with risk management DNV-RP-C201 standards. CAD materials include Solidworks files for parts, assemblies, and drawings of the evaluated models.

16 TIDAL AND WAVE POWER↗

Dynamic characterization and performance evaluation of a 10-kW power take-off with mechanical motion rectifier for wave energy conversion

The power take-off (PTO) is a key component for wave energy converters. In this paper, a compact PTO with mechanical motion rectification rated at 10 kW is designed and prototyped, and characterized. A piecewise nonlinear dynamic model is established to describe its unique dynamic property. A linear hydraulic actuator is adopted in lab testing to drive the prototype and the unknown parameters of the dynamic model are identified. Further verification shows that the model can predict the dynamic performance of the PTO well. The test results show that the mechanical motion rectifier-based PTO can achieve overall energy transfer efficiency as high as 65% in regular waves even when the generator is working below the rated electric load and speed. In the irregular wave test, the PTO achieved the overall energy transfer efficiency of 54%, and the peak-to-average ratio acquired during the test is 12.5.

16 TIDAL AND WAVE POWER↗

Biofouling and Corrosion Study for a Novel Linear Guided Wave Energy Converter (Post Access Report)

The overall objective of this project was to examine the reliability and performance of antibiofouling coatings used for a wave energy converter (WEC) developed by E-Wave Technologies. The particular coatings were selected for their low toxicity and potential compatibility with aquaculture. The aim of this work was to 1) test coating solutions to prevent biofouling growth and saltwater corrosion on the static (paddle and attachment frame surface) components of the WEC that are submerged, 2) determine adhesion of the coatings to system components, and 3) assess the ease and effectiveness of biofouling cleaning to insure long term performance of the system. An analysis of commercial coatings was performed using methods to examine the prevention of biofouling and coating adhesion properties on two key materials of the WEC, which were 316L low carbon marine grade stainless steel (SS) and Ultra High Molecular Weight Polyethylene (PE). Three marine antifouling paints were selected based on their unique properties to test how different paint styles perform on different materials. The selected paints were ePaint Ecominder self-polishing paint with Zinc Omadine for slime control, Pettit ECO HRT Copper-Free ablative antifouling with Econea biocide, and Intersleek 1100SR foul release. Pacific Northwest National Laboratory (PNNL) prepared PE and SS substrates coated with the three paints and compared the performance against uncoated substrates when submerged in raw seawater for 3-, 6-, and 9-month (m) time periods. Results in adhesion testing indicated that Pettit and ePaint materials clearly bonded strongly to SS, but did not bond comparably well to PE. It was noted during adhesion testing that the Intersleek surfaces were especially difficult to test as the paint highly resists bonding to the epoxy adhesives used with the adherence testing platform. The wear rate of the coatings was not measured under this study; however, based on adhesion testing, coatings in the sliding regions of the Ewave device are expected to wear rapidly. Sandia National Laboratories (SNL) evaluated the adhesion of three different paints to PE and SS substrates which were exposed to a marine environment for time intervals of 0, 3, 6, and 9 months. From qualitative visual analysis of the 3 in2 coupons when pulled from the tank, the 3 in2 coupons generally only appeared to have biofouling consisting of filamentous algae or diatoms, which all have relatively low mass and can be easily wiped from the surface of coupons. Qualitative visual analysis indicated that ECO HRT and Unpainted were consistently worse than Intersleek and Ecominder at all time points. Results provide insight to aid with down-selection of commercial coatings under static conditions to support reliability of the WEC and potential maintenance schedules. This investigation was conducted using small coupon samples suspended in seawater and the development of testing rigs for dynamic component level testing is needed for future work. In addition, the potential toxicity of these commercial coatings on aquaculture has not been determined by this study. One recommendation is to conduct toxicity investigations at the Environmental Toxicity Laboratory at Oak Ridge National Laboratory.

16 TIDAL AND WAVE POWER↗