Search NASA⌕ Search

SEARCH · Search NASA

Results for “waveform analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Comparison of Signals from Gravitational Wave Detectors with Instantaneous Time-Frequency Maps

Gravitational wave astronomy relies on the use of multiple detectors, so that coincident detections may distinguish real signals from instrumental artifacts, and also so that relative timing of signals can provide the sky position of sources. We show that the comparison of instantaneous time-frequency and time-amplitude maps provided by the Hilbert-Huang Transform (HHT) can be used effectively for relative signal timing of common signals, to discriminate between the case of identical coincident signals and random noise coincidences and to provide a classification of signals based on their time-frequency trajectories. The comparison is done with a X(sup 2) goodness-of~fit method which includes contributions from both the instantaneous amplitude and frequency components of the HHT to match two signals in the time domain. This approach naturally allows the analysis of waveforms with strong frequency modulation.

Stroeer, A.↗

Analysis and Validation of PMT s Waveforms in ICARUS LArTPC Using Monte Carlo Simulations

ICARUS (Imaging Cosmic and Rare Underground Signals) serves as the Far Detector in the Short Baseline Neutrino (SBN) program at Fermilab, playing a central role in investigating the potential existence of sterile neutrinos in the eV squared mass range. The detector consists of two large Liquid Argon Time Projection Chambers (LArTPCs) with a total capacity of 760 tons of liquid Argon. A key component of the system is its array of 360 Photo-Multiplier Tubes (PMTs), which detect the scintillation light produced by charged particles in liquid Argon; the fast scintillation signal enables accurate event timing, triggering, and reconstruction. Together with the TPC and CRT systems, the PMTs ensure precise interaction time measurements, which are crucial for distinguishing neutrino interactions from cosmic-ray backgrounds. ICARUS uses Hamamatsu R5912-MOD PMTs, optimized for cryogenic temperatures, with high quantum efficiency, excellent timing resolution, low dark current (around 10 nA at 1500 V), and broad spectral sensitivity (300–650 nm). These characteristics are crucial for the efficient detection of scintillation light. Analyzing the waveforms of PMT signals allows for a detailed comparison between experimental data and Monte Carlo simulations. This analysis is fundamental for improving the accuracy of neutrino event reconstruction, enhancing detector calibration, and optimizing the detector's performance for current and future operations.

Brio, V. [Catania U.] (ORCID:0009000088807391)↗

Pulsar average waveforms and hollow cone beam models

An analysis of pulsar average waveforms at radio frequencies from 40 MHz to 15 GHz is presented. The analysis is based on the hypothesis that the observer sees one cut of a hollow-cone beam pattern and that stationary properties of the emission vary over the cone. The distributions of apparent cone widths for different observed forms of the average pulse profiles (single, double/unresolved, double/resolved, triple and multiple) are in modest agreement with a model of a circular hollow-cone beam with random observer-spin axis orientation, a random cone axis-spin axis alignment, and a small range of physical hollow-cone parameters for all objects.

Backer, D. C.↗

Irreversible Electroporation of Renal Cell Carcinoma: A First-in-Man Phase I Clinical Study

Purpose: Irreversible electroporation (IRE) is a newly developed nonthermal tissue-ablation technique in which high-voltage electrical pulses of microsecond duration are applied to induce irreversible permeabilisation of the cell membrane, presumably through nanoscale defects in the lipid bilayer, leading to apoptosis. The purpose of this study was to assess the feasibility and safety of ablating renal cell carcinoma (RCC) tissue by IRE. Methods: Six patients scheduled for curative resection of RCC were included. IRE was performed during anaesthesia immediately before the resection with electrographic synchronisation. Central haemodynamics were recorded before and 5 min after electroporation. Five-channel electrocardiography (ECG) was used for detailed analysis of ST waveforms. Blood sampling and 12-lead ECG were performed before, during, and at scheduled intervals after the intervention. Results: Analysis of ST waveforms and axis deviations showed no relevant changes during the entire study period. No changes in central haemodynamics were seen 5 min after IRE. Similarly, haematological, serum biochemical, and ECG variables showed no relevant differences during the investigation period. No changes in cardiac function after IRE therapy were found. One case of supraventricular extrasystole was encountered. Initial histopathologic examination showed no immediate adverse effects of IRE (observation of delayed effects will require a different study design). Conclusion: IRE seems to offer a feasible and safe technique by which to treat patients with kidney tumours and could offer some potential advantages over current thermal ablative techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gravitational-Wave Data Analysis with Spinning Merger-Ringdown Waveforms

The recent availability of high-quality, gravitational merger-ringdown waveforms from spinning black-hole systems has made possible the development of multi-mode GW templates for use in data-analysis studies of current and proposed interferometric GW detectors. We report on recent work at NASA Goddard, analyzing the most significant modes from aligned-spin black-hole-binary mergers. From these, we have developed time-domain merger-ringdown GW templates covering the aligned-spin portion of parameter space. We also discuss how using the full information content of aligned-spin mergers can significantly reduce uncertainties in some parameters, emphasizing the significant gains possible in the last stages of merger, inaccessible to inspiral-only post-Newtonian templates.

Kelly Bernard J.↗

Time-Frequency Analysis of the Dispersion of Lamb Modes

Accurate knowledge of the velocity dispersion of Lamb modes is important for ultrasonic nondestructive evaluation methods used in detecting and locating flaws in thin plates and in determining their elastic stiffness coefficients. Lamb mode dispersion is also important in the acoustic emission technique for accurately triangulating the location of emissions in thin plates. In this research, the ability to characterize Lamb mode dispersion through a time-frequency analysis (the pseudo-Wigner-Ville distribution) was demonstrated. A major advantage of time-frequency methods is the ability to analyze acoustic signals containing multiple propagation modes, which overlap and superimpose in the time domain signal. By combining time-frequency analysis with a broadband acoustic excitation source, the dispersion of multiple Lamb modes over a wide frequency range can be determined from as little as a single measurement. In addition, the technique provides a direct measurement of the group velocity dispersion. The technique was first demonstrated in the analysis of a simulated waveform in an aluminum plate in which the Lamb mode dispersion was well known. Portions of the dispersion curves of the AO, A I , So, and S2 Lamb modes were obtained from this one waveform. The technique was also applied for the analysis of experimental waveforms from a unidirectional graphite/epoxy composite plate. Measurements were made both along and perpendicular to the fiber direction. In this case, the signals contained only the lowest order symmetric and antisymmetric modes. A least squares fit of the results from several source to detector distances was used. Theoretical dispersion curves were calculated and are shown to be in good agreement with experimental results.

Prosser, W. H.↗

Time-Frequency Analysis of the Dispersion of Lamb Modes

Accurate knowledge of the velocity dispersion of Lamb modes is important for ultrasonic nondestructive evaluation methods used in detecting and locating flaws in thin plates and in determining their elastic stiffness coefficients. Lamb mode dispersion is also important in the acoustic emission technique for accurately triangulating the location of emissions in thin plates. In this research, the ability to characterize Lamb mode dispersion through a time-frequency analysis (the pseudo Wigner-Ville distribution) was demonstrated. A major advantage of time-frequency methods is the ability to analyze acoustic signals containing multiple propagation modes, which overlap and superimpose in the time domain signal. By combining time-frequency analysis with a broadband acoustic excitation source, the dispersion of multiple Lamb modes over a wide frequency range can be determined from as little as a single measurement. In addition, the technique provides a direct measurement of the group velocity dispersion. The technique was first demonstrated in the analysis of a simulated waveform in an aluminum plate in which the Lamb mode dispersion was well known. Portions of the dispersion curves of the A(sub 0), A(sub 1), S(sub 0), and S(sub 2)Lamb modes were obtained from this one waveform. The technique was also applied for the analysis of experimental waveforms from a unidirectional graphite/epoxy composite plate. Measurements were made both along, and perpendicular to the fiber direction. In this case, the signals contained only the lowest order symmetric and antisymmetric modes. A least squares fit of the results from several source to detector distances was used. Theoretical dispersion curves were calculated and are shown to be in good agreement with experimental results.

Prosser, W. H.↗

Beat-to-Beat Blood Pressure Monitor

This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood pressure measurement algorithm.

Lee, Yong Jin↗

Beat-to-Beat Blood Pressure Monitor

This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.

Lee, Yong Jin↗

Using Digital Waveforms to Mitigate Solvent Clustering During Mass Filter Analysis of Proteins

With advances in the precision of digital electronics, waveform generation technology has progressed to a state that enables the creation of m/z filters that are purely digitally driven. These advances present new methods of performing mass analyses that provide information from a chemical system that are inherently difficult to achieve by other means. One notable characteristic of digitally driven mass filters is the capacity to transmit ions at m/z ratios that vastly exceed the capabilities of traditional resonant systems. However, the capacity to probe ion m/z ratios that span multiple orders of magnitudes across multiple orders of magnitude presents a new set of issues requiring a solution. In the present work, when probing multiply charged protein species beyond m/z 2000 using a gentle atmospheric pressure interface, the presence of solvent adducts and poorly resolved multimers can severely degrade spectral fidelity. Increasing energy imparted into a target ion population is one approach minimizing these clusters; however, the use of digital waveform technology provides an alternative that maximizes ion transport efficiency and simultaneously minimizes solvent clustering. In addition to the frequency of the applied waveform, digital manipulation also provides control over the duty cycle of the target waveform. This work examines the conditions and approach leading to optimal digital waveform operation to minimize solvent clustering. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seismic waveform viewer, processor and calculator

SWIFT is a computer code that is designed to do research level signal analysis on seismic waveforms, including visualization, filtering and measurement. LLNL is using this code, amplitude and global tomography efforts.

Matzel, E.↗

Solenoid valve performance characteristics studied

Current and voltage waveforms of a solenoid coil are recorded as the valve opens and closes. Analysis of the waveforms with respect to time and the phase of the valve cycle accurately describes valve performance.

Abe, J. T.↗

Initial Implementation Of Machine Learning System for SRF Cavity Fault Classification at CEBAF

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is high power CW electron accelerator. It uses a mixture of two types of SRF modules, older, lower energy C20/C50 modules and newer higher energy C100 modules, arrayed in two anti-parallel linear accelerators. Accurately classifying the type of cavity faults is essential to maintaining and improving accelerator performance. Each C100 cryomodule contains eight 7-cell cavities. When a cavity fault occurs within a cryomodule, all eight cavities generate 17 waveforms each containing 8192 points. This data is exported from EPICS and saved for review. Analysis of these waveforms is time intensive and requires subject matter expertise (SME). SMEs examine the data from each event and label it according to one of several known cavity fault types. Multiple machine learning models have been developed on this labeled dataset with sufficient performance to warrant the creation of a limited machine learning software system for use by accelerator operations staff. This paper discusses the transition from model development to implementation of a prototype system.

Carpenter, A.↗

Detection of suspicious mass on structures by acoustical waves

Analysis of scattered Lamb waves in thin plates and shells, with an added foreign mass on their surface, was performed. Waves were generated in a range of frequencies, up to 80 kHz, by an impact loading. The responses were detected by full-field and point-wise optical methods. Pulse holointerferometry and pulse electronic speckle patterns interferometry techniques were used to visualize the interaction of the Lamb waves with the added foreign mass. Double-channel laser vibrometry was used to record the velocity history within the proximity of the added foreign mass. It was shown that frequency analysis of the recorded waveforms was more convenient than time domain analysis when investigating the response in the thin-walled structures. The proposed method is applicable to search for suspicious masses (e.g. explosive devices) added to the structures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of aluminum-lithium alloy solidification using acoustic emission techniques

Physical phenomena associated with the solidification of an aluminum lithium alloy was characterized using acoustic emission (AE) techniques. It is shown that repeatable patterns of AE activity may be correlated to microstructural changes that occur during solidification. The influence of the experimental system on generated signals was examined in the time and frequency domains. The analysis was used to show how an AE signal from solidifying aluminum is changed by each component in the detection system to produce a complex waveform. Conventional AE analysis has shown that a period of high AE activity occurs in pure aluminum, an Al-Cu alloy, and the Al-Li alloy, as the last fraction of solid forms. A model attributes this to the internal stresses of grain boundary formation. An additional period of activity occurs as the last fraction of solid forms, but only in the two alloys. A model attributes this to the formation of interdendritic porosity which was not present in the pure aluminum. The AE waveforms were dominated by resonant effects of the waveguide and the transducer.

Henkel, Daniel P.↗

Systematic errors in low-latency gravitational wave parameter estimation impact electromagnetic follow-up observations

Among the most eagerly anticipated opportunities made possible by Advanced LIGO/Virgo are multimessenger observations of compact mergers. Optical counterparts may be short-lived so rapid characterization of gravitational wave (GW) events is paramount for discovering electromagnetic signatures. One way to meet the demand for rapid GW parameter estimation is to trade off accuracy for speed, using waveform models with simplified treatment of the compact objects’ spin. We report on the systematic errors in GW parameter estimation suffered when using different spin approximations to recover generic signals. Component mass measurements can be biased by >5σ using simple-precession waveforms and in excess of 20σ when non-spinning templates are employed. This suggests that electromagnetic observing campaigns should not take a strict approach to selecting which LIGO/Virgo candidates warrant follow-up observations based on low-latency mass estimates. For sky localization, we find that searched areas are up to a factor of ∼2 larger for non-spinning analyses, and are systematically larger for any of the simplified waveforms considered in our analysis. Distance biases for the non-precessing waveforms can be in excess of 100% and are largest when the spin angular momenta are in the orbital plane of the binary. We confirm that spin-aligned waveforms should be used for low-latency parameter estimation at the minimum. Including simple precession, though more computationally costly, mitigates biases except for signals with extreme precession effects. Our results shine a spotlight on the critical need for development of computationally inexpensive precessing waveforms and/or massively parallel algorithms for parameter estimation.

79 ASTRONOMY AND ASTROPHYSICS↗