Search NASA⌕ Search

SEARCH · Search NASA

Results for “x-ray lasers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Earth benefits from space life sciences

The applications to medicine of various results from space exploration are examined. Improvements have been made in the management of cardiovascular disease, in particular the use of the ultrasonic scanner to image arteries in three dimensions, the use of excimer lasers to disrupt arterial plaques in coronary blood vessels, and the use of advanced electrodes for cardiac monitoring. A bone stiffness analyzer has helped to diagnose osteoporosis and aid in its treatment. An automated light microscope system is used for chromosome analysis, and an X-ray image intensifier called Lixiscope is used in emergency medical care. An advanced portable defibrillator has been developed for the heart, and an insulin delivery system has been derived from space microminiaturization techniques.

Garshnek, V.↗

Results of the joint utilization of laser integrated experiments flown on payload GAS-449 aboard Columbia mission 61-C

The high peak power neodymium YAG laser and the HeNe laser aboard GAS-449 have demonstrated the survivability of the devices in the micro-gravity, cosmic radiation, thermal, and shock environment of space. Some pharmaceuticals and other materials flown in both the active and passive status have demonstrated reduction in volume and unusual spectroscopic changes. X-ray detectors have shown cosmic particle hits with accompanying destruction at their interaction points. Some scattering in the plates is in evidence. Some results of both active and passive experiments on board the GAS-449 payload are evaluated.

Muckerheide, M. C.↗

Theoretical temperature-dependent branching ratios and laser thresholds of the 3F4 to 3H6 levels of Tm(3+) in ten garnets

The calculated energy levels, the branching ratios, and the estimated thresholds for thulium operating on the 3F4 to 3H6 transitions are reported. Garnet materials with the general formula A3B2C3O12 are evaluated. Calculations are performed for the A side under the assumption of D2 symmetry. X-ray data available in the literature are used to evaluate the crystal-field components, A sub nm. Even-n components are employed to calculate the crystal-field splittings within the manifold. Thermal occupation factors are determined in a straightforward manner using a Boltzmann distribution for the respective manifolds. Odd-n components are applied to calculate the transition probabilities for electric field transitions. It is determined that the magnetic dipole contributions to the transition probability are comparable to the electric dipole contributions in some cases. Thresholds as a function of the density of thulium atoms are calculated.

Filer, Elizabeth D.↗

Laser-plasma spectra of highly ionized fluorine

Lines between 11.3 and 17.2 A of lithium-like, helium-like, and hydrogen-like fluorine have been observed in spectra of laser-produced plasmas. These lines include nine members of the Lyman series of F IX; eight members of the principal series of F VIII; and satellite lines arising from doubly excited configurations of F VII and F VIII. Similar satellite lines of the abundant solar elements have been identified in soft X-ray spectra of solar flares. A wavelength list of fluorine lines is given, and physical conditions in the plasma are discussed.

Feldman, U.↗

Grazing incidence technique to obtain spatially resolved spectra from laser heated plasmas

An experimental method is described in which a grazing incidence spectrograph is used to obtain spatially resolved spectra of laser heated plasmas in the 6-370-A region. In the experiment, small target spheres were irradiated by tightly focused laser beams. A tilted grazing incidence elliptical mirror placed 1.3 m from the target focuses the plasma radiation on the spectrograph slit at a distance of 0.7 m producing a useful degree of spatial resolution in the recorded spectral lines. The spectrum from a copper target is presented together with an X-ray pinhole camera image of the plasma.

Behring, W. E.↗

Ultrasonic nondestructive materials characterization

A brief review of ultrasonic wave propagation in solid materials is presented with consideration of the altered behavior in anisotropic and nonlinear elastic materials in comparison with isotropic and linear elastic materials. Some experimental results are described in which ultrasonic velocity and attenuation measurements give insight into materials microstructure and associated mechanical properties. Recent developments with laser beam non-contact generation and detection of ultrasound are presented. The results of several years of experimental measurements using high-power ultrasound are discussed, which provide substantial evidence of the inability of presently accepted theories to fully explain the interaction of ultrasound with solid materials. Finally, a special synchrotron X-ray topographic system is described which affords the possibility of observing direct interaction of ultrasonic waves with the microstructural features of real crystalline solid materials for the first time.

Green, R. E., Jr.↗

A Fiber Optic Probe for Monitoring Protein Aggregation, Nucleation, and Crystallization

Protein crystals are experimentally grown in hanging drops in microgravity experiments on-board the Space Shuttle orbiter. The technique of dynamic light scattering (DLS) can be used to monitor crystal growth process in hanging droplets (approx. 30 (L)) in microgravity experiments, but elaborate instrumentation and optical alignment problems have made in-situ applications difficult. In this paper we demonstrate that such experiments are now feasible. We apply a newly developed fiber optic probe to various earth and space (micro- gravity) bound protein crystallization system configurations to test its capability. These include conventional batch (cuvette or capillary) systems, hanging drop method in a six-pack hanging drop vapor diffusion apparatus (HDVDA), a modified HDVDA for temperature- induced nucleation and aggregation studies, and a newly envisioned dynamically controlled vapor diffusion system (DCVDS) configuration. Our compact system exploits the principles of DLS and offers a fast (within a few seconds) means of quantitatively and non-invasively monitoring the various growth stages of protein crystallization. In addition to DLS capability, the probe can also be used for performing single-angle static light scattering measurements. It utilizes extremely low levels of laser power (approx. few (W)) without a need of having any optical alignment and vibration isolation. The compact probe is also equipped with a miniaturized microscope for visualization of macroscopic protein crystals. This new optical diagnostic system opens up enormous opportunity for exploring new ways to grow good quality crystals suitable for x-ray crystallographic analysis and may help develop a concrete scientific basis for understanding the process of crystallization.

Ansari, Rafat R.↗

Computational modelling of Er(3+): Garnet laser materials

The Er(3+) ion has attracted a lot of interest for four reasons: (1) Its (4)I(sub 13/2) yields (4)I(sub 15/2) transition lases in the eyesafe region near 1.5 micron; (2) the (4)I(sub 13/2) transition lases near 2.8 micron, an important wavelength for surgical purposes; (3) it displays surprisingly efficient upconversion with lasing observed at 1.7, 1.2, 0.85, 0.56, 0.55, and 0.47 micron following 1.5 micron pumping; and (4) it has absorption bands at 0.96 and 0.81 micron and thus can be diode pumped. However, properties desirable for upconversion reduce the efficiency of 1.5 and 3 micron laser operation and vice versa. Since all of the processes are influenced by the host via the crystal field induced stark splittings in the Er levels, this project undertook modelling of the host influence on the Er lasinng behavior. While growth and measurement of all ten Er(3+) doped garnets is the surest way of identifying hosts which maximize upconversion (or conversly, 1.5 and 3 micron performance), it is also expensive - costing approximately $10,000/material or approximately $100,000 for the materials computationally investigated here. The calculations were performed using a quantum mechanical point charge model developed by Clyde Morrison at Harry Diamond Laboratories. The programs were used to fit the Er:YAG experimental energy levels so that the crystal field parameters, B(sub nm) could be extracted. From these radial factors, rho (sub n) were determined for Er(3+) in garnets. These, in combination with crystal field components, Anm, available from X-ray data, were used to predict energy levels for Er in the other nine garnet hosts. The levels in Er:YAG were fit with an rms error of 12.2/cm over a 22,000/cm range. Predicted levels for two other garnets for which literature values were available had rms errors of less than 17/cm , showing the calculations to be reliable. Based on resonances between pairs of calculated stark levels, the model predicts GSGG as the best host for 1.5 micron laser operation, GSGG or YSAG as the best host for a 2.8 micron operation, and LuGG as the best host for an upconversion material.

Spangler, Lee H.↗

Surface roughness of flat and curved optical surfaces

Surface roughness measurement has several applications. Even a few A roughness will cause scattered light in optical systems. Smooth surfaces are required in a wide variety of instruments. For example, the outputs of the high power lasers are limited by the surface roughness of mirrors and windows. Similarly, the information storage capacity of magnetic media is limited by the roughness of the surface. Roughness reduces the resolving power of optics and distorts images. The performance of certain thin film components in electronic industries is affected by the roughness on the film surface. X-ray astronomical telescopes require smooth curved surfaces. To improve the surface quality, super sensitive detection methods are required. Wide ranging measurement techniques are developed based on interferometry, electron microscopy, C-rays, ellipsometry, light scattering, and using mechanical stylus, etc. Though there are several techniques available for measurement and evaluation of the surfaces, no single technique is fully adequate. Also, the technique used should be nondestructive and highly sensitive. So, an optical heterodyne profilometer was fabricated. Its current sensitivity is much better than 10A rms. It is a noncontact and nondestructive technique. The instrument can be operated even by unskilled personnel for routine measurements.

George, M. C.↗

Design of an unmanned Martian polar exploration system

The design of an unmanned Martian polar exploration system is presented. The system elements include subsystems for transportation of material from earth to Mars, study of the Martian north pole, power generation, and communications. Early next century, three Atlas 2AS launch vehicles will be used to insert three Earth-Mars transfer vehicles, or buses, into a low-energy transfer orbit. Capture at Mars will be accomplished by aerobraking into a circular orbit. Each bus contains four landers and a communications satellite. Six of the twelve total landers will be deployed at 60 deg intervals along 80 deg N, and the remaining six landers at 5 deg intervals along 30 deg E from 65 deg N to 90 deg N by a combination of retrorockets and parachutes. The three communications satellites will be deployed at altitudes of 500 km in circular polar orbits that are 120 deg out of phase. These placements maximize the polar coverage of the science and communications subsystems. Each lander contains scientific equipment, two microrovers, power supplies, communications equipment, and a science computer. The lander scientific equipment includes a microweather station, seismometer, thermal probe, x-ray spectrometer, camera, and sounding rockets. One rover, designed for short-range (less than 2 km) excursions from the lander, includes a mass spectrometer for mineral analysis, an auger/borescope system for depth profiling, a deployable thermal probe, and charge coupled device cameras for terrain visualization/navigation. The second rover, designed for longer-range (2-5 km) excursions from the lander, includes radar sounding/mapping equipment, a seismometer, and laser ranging devices. Power for all subsystems is supplied by a combination of solar cells, Ni-H batteries, and radioisotope thermoelectric generators. Communications are sequenced from rovers, sounding rockets, and remote sensors to the lander, then to the satellites, through the Deep Space Network to and from earth.

Baldwin, Curt↗

Harmonic generation at high field strengths - Frequency shifts and saturation phenomena

Optical harmonic generation and mixing in the gas phase has been proposed as a technique for the generation of coherent radiation in the vacuum ultraviolet and soft X-ray spectral region. At the high field strengths required by these processes the interaction between atoms and the electromagnetic field shows intensity-dependent resonances. In this paper we modify harmonic generation theory to include the effect of these frequency shifts. Closed-form expressions for generated dipole moment, absorption probability, and coherence length are presented. The most important consequences of frequency shifts on resonantly enhanced processes are that the pump laser must be tuned away from the small-field resonance frequency, that the conversion efficiency may saturate, and that the dispersion of the medium may change sign. As an example, the generation of 198-A radiation by a five-photon mixing process in Li(+) is considered.

Stappaerts, E. A.↗

Vapor phase diamond growth technology

Ion beam deposition chambers used for carbon film generation were designed and constructed. Features of the developed equipment include: (1) carbon ion energies down to approx. 50 eV; (2) in suit surface monitoring with HEED; (3) provision for flooding the surface with ultraviolet radiation; (4) infrared laser heating of substrate; (5) residual gas monitoring; (6) provision for several source gases, including diborane for doping studies; and (7) growth from either hydrocarbon source gases or from carbon/argon arc sources. Various analytical techniques for characterization of from carbon/argon arc sources. Various analytical techniques for characterization of the ion deposited carbon films used to establish the nature of the chemical bonding and crystallographic structure of the films are discussed. These include: H2204/HN03 etch; resistance measurements; hardness tests; Fourier transform infrared spectroscopy; scanning auger microscopy; electron spectroscopy for chemical analysis; electron diffraction and energy dispersive X-ray analysis; electron energy loss spectroscopy; density measurements; secondary ion mass spectroscopy; high energy electron diffraction; and electron spin resonance. Results of the tests are summarized.

Angus, J. C.↗

Centroid Detector Assembly for the AXAF-I Alignment Test System

The High Resolution Mirror Assembly (HRMA) of the Advanced X-ray Astrophysics Facility (imaging) (AXAF-I) consists of four nested paraboloids and four nested hyperboloids, all of meter-class size, and all of which are to be assembled and aligned in a special 15 meter tower at Eastman Kodak Company in Rochester, NY. The goals of the alignment are (1) to make the images of the four telescopes coincident; (2) to remove coma from each image individually; and (3) to control and determine the final position of the composite focus. This will be accomplished by the HRMA Aligment Test System (HATS) which is essentially a scanning Hartmann test system. The scanning laser source and the focal plane of the HATS are part of the Centroid Detector Assembly (CDA) which also includes processing electronics and software. In this paper we discuss the design and the measured performance of the CDA.

Glenn, Paul↗

A solar flare X-ray polarimeter for the Space Shuttle

An instrument has recently been built and tested which is designed to measure the polarization of the hard (5-30 keV) X-ray emission from solar flares, and thereby to investigate the energy release mechanism and constrain flare models. In particular, these measurements will help to determine whether hard X-ray bursts are produced by nonthermal or by thermal electrons. The polarimeter makes use of the angular dependence of Thomson scattering from targets of metallic lithium. It has an energy resolution of a few keV, a time resolution of 5 s, and sufficient sensitivity to measure polarization levels (3 sigma) of a few percent in about 10 s for a moderate strength solar flare. The instrumental polarization has been directly measured and found to be within the design goal of approximately 1%. This polarimeter is scheduled to be flown as part of the OSS-1 pallet on an early Space Shuttle mission.

Lemen, J. R.↗

Fiber optic and laser sensors IX; Proceedings of the Meeting, Boston, MA, Sept. 3-5, 1991

The present volume on fiber-optic and laser sensors discusses industrial applications of fiber-optic sensors, fiber-optic temperature sensors, fiber-optic current sensors, fiber-optic pressure/displacement/vibration sensors, and generic fiber-optic systems. Attention is given to a fiber-sensor design for turbine engines, fiber-optic remote Fourier transform IR spectroscopy, near-IR fiber-optic temperature sensors, and an intensity-type fiber-optic electric current sensor. Topics addressed include fiber-optic magnetic field sensors based on the Faraday effect in new materials, diaphragm size and sensitivity for fiber-optic pressure sensors, a microbend pressure sensor for high-temperature environments, and linear position sensing by light exchange between two lossy waveguides. Also discussed are two-mode elliptical-core fiber sensors for measurement of strain and temperature, a fiber-optic interferometric X-ray dosimeter, fiber-optic interferometric sensors using multimode fibers, and optical fiber sensing of corona discharges.

Depaula, Ramon P.↗

Some correlations between measurements by the Apollo gamma-ray spectrometer and other lunar observations

Observations by the Apollo 15 and 16 gamma-ray spectrometers are compared with those of a number of other experiments, both compositional and noncompositional. A general correspondence with topography is seen. The Van de Graaff area is a unique farside region with respect to observations by the laser altimeter, the subsatellite magnetometer, and the gamma-ray spectrometer. X-ray and alpha particle orbital measurements show a broad general agreement with gamma-ray data, although results from additional elements in the gamma-ray spectrum are needed to extend the comparison with X-ray data. A comparison of Th concentrations with those found at various landing sites shows generally good agreement, with the orbital values tending to be somewhat higher.

Trombka, J. I.↗

X-ray emission from high temperature plasmas

The physical processes occurring in plasma focus devices were studied. These devices produce dense high temperature plasmas, which emit X rays of hundreds of KeV energy and one to ten billion neutrons per pulse. The processes in the devices seem related to solar flare phenomena, and would also be of interest for controlled thermonuclear fusion applications. The high intensity, short duration bursts of X rays and neutrons could also possibly be used for pumping nuclear lasers.

Harries, W. L.↗

The correlation of alkalis and aluminum during high-temperature volatilization of albite and nepheline

Our previous study of high-temperature evaporation of mafic targets has shown a systematic enrichment of newly-formed condensates in silicon and alkalis and depletion in refractory elements (Al, Ca, Ti). This effect, which is consistent with the volatility of the elements, was also tested for several experiments with acidic targets. In one case it was the impact evaporation of granite targets using a light-gas gun facility. Analyses of the condensate which was collected during the impact show that it was enriched in Al and Na so that the composition of the condensate became close to nepheline. In the work of Nagahara, an incongruent evaporation of alkali feldspars under stationary conditions has been also proposed. These discoveries required a more detailed study of high-temperaure evaporation of monomineralic Al-silicate targets. In these experiments, we have used samples of oligoclase and of nepheline. Vaporization of samples was performed in a hermetic cell filled with helium at normal temperature and pressure using a powerful Nd-laser focused on the sample. Laser pulses had the following parameters: luminous energy approximately 600 J, duration approximately 10(exp -3) s, density of luminosity was approximately 5 x 10(exp 6) W/sq cm, the temperature of vaporization is about 3000-4000 K. About 4 cm from the sample, a nickel foil was placed on which the condensate was collected. Films of condensate were analyzed using X-Ray Photo-Electron spectrometer ES-2401. The measurement of internal chemical composition and of the charging state of elements through the whole depth of the condensed films was made layer by layer with argon-ion etching of 200 A of the film per step. Results of this study are given. The bottom layers of condensed film correspond to the front parts of the evaporated cloud or to condensation at the beginning of the evaporative process and surface layers to condensation at the end of the process.

Dikov, Yu. P.↗