Search NASA⌕ Search

SEARCH · Search NASA

Results for “x-ray microcalorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Implementation of Complex Signal Processing Algorithms for Position-Sensitive Microcalorimeters

We have recently reported on a theoretical digital signal-processing algorithm for improved energy and position resolution in position-sensitive, transition-edge sensor (POST) X-ray detectors [Smith et al., Nucl, lnstr and Meth. A 556 (2006) 2371. PoST's consists of one or more transition-edge sensors (TES's) on a large continuous or pixellated X-ray absorber and are under development as an alternative to arrays of single pixel TES's. PoST's provide a means to increase the field-of-view for the fewest number of read-out channels. In this contribution we extend the theoretical correlated energy position optimal filter (CEPOF) algorithm (originally developed for 2-TES continuous absorber PoST's) to investigate the practical implementation on multi-pixel single TES PoST's or Hydras. We use numerically simulated data for a nine absorber device, which includes realistic detector noise, to demonstrate an iterative scheme that enables convergence on the correct photon absorption position and energy without any a priori assumptions. The position sensitivity of the CEPOF implemented on simulated data agrees very well with the theoretically predicted resolution. We discuss practical issues such as the impact of random arrival phase of the measured data on the performance of the CEPOF. The CEPOF algorithm demonstrates that full-width-at- half-maximum energy resolution of < 8 eV coupled with position-sensitivity down to a few 100 eV should be achievable for a fully optimized device.

Smith, Stephen J.↗

Measuring H0 and q0 with X-ray lines from galaxy clusters

A new method of measuring angular diameter distances, and hence H0 and q0, by means of X-ray observations of galaxy clusters is proposed. It resembles the method which combines maps of X-ray continuum emission with maps of the Suniaev-Zel'dovich effect, but substitutes measurements of X-ray absorption lines in the spectra of background quasars for the Suniaev-Zel'dovich effect. When the high resolution permitted by the AXAF microcalorimeter becomes available, this method should yield results with significantly smaller uncertainty.

Krolik, Julian H.↗

Optimization of X-ray Absorbers for High-Resolution TES Detectors in NewATHENA X-IFU

NewATHENA’s X-ray Integral Field Unit (X-IFU) uses a large-format array of Transition Edge Sensor (TES) microcalorimeters coupled with absorbers made of gold and bismuth providing 4 eV FWHM resolution up to 7 keV in the 0.2- 12 keV band. X-ray absorbers must be thick enough for photon absorption, maintain low heat capacity for energy resolution, and have good thermalization properties. The X-IFU requires total Quantum Efficiency (QE) of 96%, 87%, and 63% at 1, 7, and 9.5 keV, respectively. Optimal thicknesses are 1.05 µm gold and 5.5 µm bismuth to achieve 0.731 pJ/K at 90 mK and 87% QE at 7 keV. While typical TES absorbers are 3-4 µm thick, producing the required 5.5 µm Bi absorbers via standard electroplating creates enlarged grains and surface roughness. The increased roughness and grain size variability produced with our standard recipe have resulted in instances of 1) low energy spectral tails 2) spectral broadening of the energy resolution and 3) thermal shorts between pixels when a large grain bridges the gap between absorbers. In this study, we have introduced a new fabrication process and altered the morphology of the thick Bi through changes in the electroplating process. The process changes are intended to address all three issues as well as reduce particulate contamination observed on the finished detector arrays.

Absorber↗

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics↗

Position Sensitive Microcalorimeters

A Position Sensitive Transition-Edge Sensor (PoST) is a microcalorimeter device capable of one-dimensional imaging spectroscopy. The device consists of two Transition-Edge Sensors (TESs) connected to the ends of a long X-ray absorbing strip. The energy of a photon hitting the absorber and the position of the absorption event along the strip is measured from the response in the two sensors by analyzing the relative signal sizes, pulse rise times, and the sum of the pulses measured at each sensor, We report on the recent PoST effort at Goddard for applications to large field of view, high-energy- resolution, X-ray astrophysics.

Sadleir, J. E.↗

Measuring X-Ray Emission Line Shapes in Neutral Species for XRISM Calibration

Space X-ray spectrometers such as the Resolve instrument on XRISM require precise calibration in order to interpret the spectra of astrophysical objects. Key components of the calibration are the energy scale and the core line spread function, both of which vary with photon energy. A major issue in the calibration of high-resolution spectrometers is locating good calibrators with well-known and stable intrinsic line shapes. Neutral fluorescence is widely used, but inner-shell transitions in neutral atoms often exhibit complex, poorly documented line shapes that vary with excitation conditions. Here, in this study, we present empirical measurements of K-shell transitions in neutral O and F below 1 keV using an engineering model XRISM calorimeter array, an electron bombardment modulated X-ray source, and an electron beam ion trap (EBIT) to provide a precise energy reference. In addition, we report measurements of the Mo Lα complex with the transition-edge microcalorimeter spectrometer (TEMS), which reveal strong satellite structure and sensitivity of the line shape to the incident exciting spectrum. Together, these results demonstrate the need for empirical line-shape models, highlight the nonstationary nature of neutral fluorescence features, and define a path toward developing transfer standards for XRISM and future precision instruments such as Athena/X-IFU.

Astronomy and AstroPhysics↗

Design and Performance of the Astro-E/XRS Microcalorimeter Array and Anti-Coincidence Detector

The XRS instrument has an array of 32 micro-calorimeters at the focal plane. These calorimeters consist of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices have demonstrated a resolution of 9 eV at 3 keV and 11 eV at 6 keV. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, operating temperature, thermistor size, absorber choice, and means of attaching the absorber to the thermistor bearing element. We will present representative performance data, though a more detailed presentation of the results of the instrument calibration is presented elsewhere in these proceedings. A silicon ionization detector is located behind the calorimeter array and serves to reject events due to cosmic rays. We will briefly describe this anti-coincidence detector and its performance in conjunction with the array.

Stahle, C. K.↗

Electron Impact Excitation Cross Section Measurement for n=3 to n=2 Line Emission in Fe(17+) to Fe(23+)

We have measured the electron impact excitation cross sections for the strong iron L-shell 3 --> 2 lines of Fe XVIII to Fe XXIV at the EBIT-I electron beam ion trap using a crystal spectrometer and NASA-Goddard Space Flight Centers 6 x 6 pixel array microcalorimeter. The cross sections were determined by direct normalization to the well established cross section of radiative electron capture through a sophisticated model analysis which results in the excitation cross section for the strong Fe L-shell lines at multiple electron energies. This measurement is part of a laboratory X-ray astrophysics program utilizing the Livermore electron beam ion traps EBIT-I and EBIT-II.

Chen, H.↗

Intrinsic Line Shape Measurements of the XRS Instrument on Astro-E2

The XRS instrument on the Astro-E2 observatory contains a substantially improved microcalorimeter array over the Astro-E mission. In addition to roughly a factor of 2 improvement in the detector resolution at 6 keV, the detector response is shown to be almost perfectly gaussian. We have made measurements of the detector response of the flight instrument, using a double crystal monochrometer at 4 and 8 keV, a 55-Fe internal conversion source, and x-ray induced fluorescence from a number of targets including Ti, Cu, and GaAs. The detector response has been measured to be entirely gaussian to at least 2 orders of magnitude down from the peak of the line or line complex. This is in sharp contrast to the results from the XRS on Astro-E where many channels exhibited excess counts on the high energy side of the spectral lines. Here we present details of the line shape measurement as well as the detector response as measured during the XRS ground calibration including details of the line fits and line models.

Porter, F. Scott↗

Laboratory Measurements of the X-ray Line Emission from Neon-like Fe XVII

We have conducted a systematic study of the dominant x-ray line emission from Fe XVII. These studies include relative line intensities in the optically thin limit, intensities in the presence of radiation from satellite lines from lower charge states of iron, and the absolute excitation cross sections of some of the strongest lines. These measurements were conducted at the Lawrence Livermore National Laboratory electron beam ion trap facility using crystal spectrometers and a NASA-Goddard Space Flight Center microcalorimeter array.

Brown, G. V.↗

Removing Spectral Diagnostics of Galactic and Stellar X-Ray Emission from Charged Exchange Recombination

Our research uses the electron beam ion trap (EBIT) at the Lawrence Livermore National Laboratory to study X-ray emission from the charge exchange (CX) of highly charged ions with neutral gases. The resulting data help to fill a void in existing experimental and theoretical understanding of this atomic physics process, and are needed to explain all or part of the observed X-ray emission from the soft X-ray background, stellar winds, the Galactic Center and Galactic Ridge, supernova ejecta, and photoionized nebulae. Appreciation of the astrophysical relevance of our work continues to grow with the publication of roughly a dozen papers in the past four years describing Chandra and XMM observations of geocoronal and heliospheric CX emission, the temporal variation of such emission and correlation with X-ray emission enhancements observed by ROSAT, the theoretical spatial distribution of that emission, and CX emission around other stars. A similar number of papers were also published during that time describing CX emission from planets and comets. We expect that the launch of ASTRSE2, with its second-generation XRS microcalo- (with 6-eV resolution), will reveal even more clearly the contributions of CX to astrophysical emission. In our EBIT work we collected CX spectra from such ions as H-like and He-like Ne, Ar, and Fe. Our early measurements were made with a high-purity Ge detector, but during the second year we began operation of the first-generation XRS microcalorimeter (a twin of the XRS on ASTRO-E) and greatly improved the resolution of our measurements from roughly 150 eV (FWHM) with the Ge detectors to 10 eV with the XRS. We found that saturation of the XRS counting apparatus, which we described in our proposal as a potential concern, is not a problem for studying CX. During the course of our research, we expanded the number of injection gases permitted by the LLNL safety team, purchased and eventually operated an atomic H source, and clearly demonstrated the feasibility of our longer-range plan. For example, we successfully injected He into EBIT (not a small feat because of the difficulty of maintaining a good vacuum with He and avoiding electrical breakdown) to collect a H-like oxygen CX spectrum. The highest energy CX spectrum recorded with the XRS to date is that of the Ar K-shell emission. These measurements provided the first observation of the relative intensity ratios of resolved He-like singlet and triplet n=2->1 lines. We also carried out measurements of He-like Ne as a function of collision energy (i.e., ion temperature). Significant differences in the resulting x-ray spectra were noted. In all cases, the intensity of high-n H-like Lyman lines is significantly higher than current theoretical CX models predict.

Wargelin, Brad↗

Detector Assembly and the Ultralow-Temperature Refrigerator for XRS

The X-ray spectrometer (XRS) on the Japanese Astro-E Spacecraft is the first ultra low temperature space borne instrument. The system utilizes a 900g Ferric Ammonium Alum (FAA) Adiabatic Demagnetization Refrigerator (ADR) with a helium-3 gas gap heat switch to cool the detector assembly to 0.060K. The system operates in a "single shot" configuration allowing the system to remain at its operating temperature for about 40 hours in the lab. The on-orbit performance is expected to be about 35 hours with a 97% duty cycle. The detector assembly for XRS consists of a 32 channel microcalorimeter array bias electronics, thermometry, and an anti-coincidence detector that are attached to the cold stage of the ADR. To thermally Isolate the detector system from the superfluid helium reservoir, the detector system is suspended by Kevlar cords and electrical connection in made by L30, 17-micron diameter, tensioned NbTi leads. The detectors are read out in a source-follower arrangement using FET amplifiers operating at 130K mounted in multiply-thermally-isolated assemblies that also use Kevlar and stainless steel wiring. The design and thermal performance of this system will be discussed and compared to the theoretical limits.

Porter, F. S.↗

XRISM high-resolution X-ray spectroscopy of Cygnus X-1: Orbital and short-term variability of iron absorption

We present the first high-resolution spectroscopy of the black hole high-mass X-ray binary Cygnus X-1 with XRISM, including orbital-phase-resolved analyses and tentative evidence of short-term variability in the Fe K band on second timescales. Using data from the Performance Verification phase in 2024 April, we analyzed spectral variability across orbital phases with the Resolve microcalorimeter and the Xtend CCD imager. The unprecedented resolution of Resolve reveals variability in highly ionized Fe absorption lines. The absorption features show orbital-phase-dependent variability in column density, ionization state, and blueshifted velocity, suggesting structural variations in the focused stellar wind along the line of sight. We also find indications of subtle broadening of the neutral Fe emission profile. In addition, intensity-sorted spectroscopy during dip phases suggests possible variability on timescales of a few seconds in the absorption features, consistent with cooler, denser, and lower-ionized gas clumps. Although the statistical significance is limited, these results hint that the stellar wind and the X-rays from the accretion disk around the black hole may interact on timescales as short as a few seconds. These XRISM results constrain wind-fed accretion in Cyg X-1 and highlight Resolve’s capability to probe plasma environments in high-mass X-ray binaries.

Astronomy and AstroPhysics↗

Thermal Transport Model for Heat Sink Design

A document discusses the development of a finite element model for describing thermal transport through microcalorimeter arrays in order to assist in heat-sinking design. A fabricated multi-absorber transition edge sensor (PoST) was designed in order to reduce device wiring density by a factor of four. The finite element model consists of breaking the microcalorimeter array into separate elements, including the transition edge sensor (TES) and the silicon substrate on which the sensor is deposited. Each element is then broken up into subelements, whose surface area subtends 10 10 microns. The heat capacity per unit temperature, thermal conductance, and thermal diffusivity of each subelement are the model inputs, as are the temperatures of each subelement. Numerical integration using the Finite in Time Centered in Space algorithm of the thermal diffusion equation is then performed in order to obtain a temporal evolution of the subelement temperature. Thermal transport across interfaces is modeled using a thermal boundary resistance obtained using the acoustic mismatch model. The document concludes with a discussion of the PoST fabrication. PoSTs are novel because they enable incident x-ray position sensitivity with good energy resolution and low wiring density.

Chervenak, James A.↗

The In-Flight Calibration Program for the XRS on Astro-E2

The X-Ray Spectrometer (XRS) will be launched in February 2005 as part of the Astro-E2 mission. It will provide unprecedented throughput and resolving powers particularly at high energies. In this presentation we will describe the in-flight calibration program. The energy scale of the XRS is a complex, non-linear function of the noise and power conditions on the array. It will be calibrated empirically using the bright point sources, Capella and GX301-2. Ground calibration of the line spread function show it to be almost perfectly Gaussian. The in-flight calibration is designed to verify this using the energy scale targets. The effective area curve of the XRS contains discreet edge structure from the mirrors, the optical blocking filters, and the microcalorimeter HgTe absorbers. The effective area Calibration program will simultaneously measure these absorption edges and the global effective area properties using the relatively featureless sources 3C273 and Mrk421. Additional monitoring of any ice build-up on the filters will be conducted using observations of the supernova remnants N132D and E0102.

Cottam, J.↗

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial↗

Laboratory Astrophysics at the LLNL Electron Beam Ion Traps: EBIT-I and EBIT-II

In order to provide a complete, accurate set of atomic data for interpreting spectra provided by missions such as XMM-Newton, the Chandra X-Ray Observatory, and Astro-E2, we have harnessed the Lawrence Livermore National Laboratory's electron beam ion traps EBIT-I. EBIT-II, and Super-EBIT for laboratory astrophysics. In support of this work we have developed a number of unique techniques, including the ability to experimentally simulate a Maxwellian distribution of electron energies and measuring low-energy charge exchange cross sections using the magnetic trapping mode. We have also built and operated a full suite of spectrometers spanning the 1-7000 Angstrom wavelength band, the most recent being a spectrometer based on a spare Astro-E (6 x 6) microcalorimeter array. Results of our efforts include a complete list of wavelengths of the Fe L-shell transitions, measurements of absolute and relative cross sections for direct impact, dielectronic, and resonance excitation, and measurements of low energy charge transfer reactions. A brief overview of the LLNL ebit facility, its capabilities, and some results will be discussed.

Brown, G. V.↗

Development of Position-sensitive Transition-edge Sensor X-ray Detectors

We report on the development of position-sensitive transition-edge sensors (PoST's) for future x-ray astronomy missions such as the International X-ray Observatory (IXO), currently under study by NASA and ESA. PoST's consist of multiple absorbers each with a different thermal coupling to one or more transition-edge sensor (TES). This differential thermal coupling between absorbers and TES's results in different characteristic pulse shapes and allows position discrimination between the different pixels. The development of PoST's is motivated by a desire to achieve maximum focal-plane area with the least number of readout channels and as such. PoST's are ideally suited to provide a focal-plane extension to the Constellation-X microcalorimeter array. We report the first experimental results of our latest one and two channel PoST's, which utilize fast thermalizing electroplated Au/Bi absorbers coupled to low noise Mo/Au TES's - a technology already successfully implemented in our arrays of single pixel TES's. We demonstrate 6 eV energy resolution coupled with spatial sensitivity in the keV energy range. We also report on the development of signal processing algorithms to optimize energy and position sensitivity of our detectors.

Smith, S. J.↗