Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

TU-C-201-00: Clinical Implementation of HDR Brachytherapy

Recent use of HDR has increased while planning has become more complex often necessitating 3D image-based planning. While many guidelines for the use of HDR exist, they have not kept pace with the increased complexity of 3D image-based planning. Furthermore, no comprehensive document exists to describe the wide variety of current HDR clinical indications. This educational session aims to summarize existing national and international guidelines for the safe implementation of an HDR program. A summary of HDR afterloaders available on the market and their existing applicators will be provided, with guidance on how to select the best fit for each institution’s needs. Finally, the use of checklists will be discussed as a means to implement a safe and efficient HDR program and as a method by which to verify the quality of an existing HDR program. This session will provide the perspective of expert HDR physicists as well as the perspective of a new HDR user. Learning Objectives: Summarize national and international safety and staffing guidelines for HDR implementation Discuss the process of afterloader and applicator selection for gynecologic, prostate, breast, interstitial, surface treatments Learn about the use of an audit checklist tool to measure of quality control of a new or existing HDR program Describe the evolving use of checklists within an HDR program.

60 APPLIED LIFE SCIENCES↗

TU-C-201-01: Clinical Implementation of HDR: A New User’s Perspective

Recent use of HDR has increased while planning has become more complex often necessitating 3D image-based planning. While many guidelines for the use of HDR exist, they have not kept pace with the increased complexity of 3D image-based planning. Furthermore, no comprehensive document exists to describe the wide variety of current HDR clinical indications. This educational session aims to summarize existing national and international guidelines for the safe implementation of an HDR program. A summary of HDR afterloaders available on the market and their existing applicators will be provided, with guidance on how to select the best fit for each institution’s needs. Finally, the use of checklists will be discussed as a means to implement a safe and efficient HDR program and as a method by which to verify the quality of an existing HDR program. This session will provide the perspective of expert HDR physicists as well as the perspective of a new HDR user. Learning Objectives: Summarize national and international safety and staffing guidelines for HDR implementation Discuss the process of afterloader and applicator selection for gynecologic, prostate, breast, interstitial, surface treatments Learn about the use of an audit checklist tool to measure of quality control of a new or existing HDR program Describe the evolving use of checklists within an HDR program.

60 APPLIED LIFE SCIENCES↗

TU-C-201-02: Clinical Implementation of HDR: Afterloader and Applicator Selection

Recent use of HDR has increased while planning has become more complex often necessitating 3D image-based planning. While many guidelines for the use of HDR exist, they have not kept pace with the increased complexity of 3D image-based planning. Furthermore, no comprehensive document exists to describe the wide variety of current HDR clinical indications. This educational session aims to summarize existing national and international guidelines for the safe implementation of an HDR program. A summary of HDR afterloaders available on the market and their existing applicators will be provided, with guidance on how to select the best fit for each institution’s needs. Finally, the use of checklists will be discussed as a means to implement a safe and efficient HDR program and as a method by which to verify the quality of an existing HDR program. This session will provide the perspective of expert HDR physicists as well as the perspective of a new HDR user. Learning Objectives: Summarize national and international safety and staffing guidelines for HDR implementation Discuss the process of afterloader and applicator selection for gynecologic, prostate, breast, interstitial, surface treatments Learn about the use of an audit checklist tool to measure of quality control of a new or existing HDR program Describe the evolving use of checklists within an HDR program.

60 APPLIED LIFE SCIENCES↗

TU-C-201-03: The Use of Checklists and Audit Tools for Safety and QA

Recent use of HDR has increased while planning has become more complex often necessitating 3D image-based planning. While many guidelines for the use of HDR exist, they have not kept pace with the increased complexity of 3D image-based planning. Furthermore, no comprehensive document exists to describe the wide variety of current HDR clinical indications. This educational session aims to summarize existing national and international guidelines for the safe implementation of an HDR program. A summary of HDR afterloaders available on the market and their existing applicators will be provided, with guidance on how to select the best fit for each institution’s needs. Finally, the use of checklists will be discussed as a means to implement a safe and efficient HDR program and as a method by which to verify the quality of an existing HDR program. This session will provide the perspective of expert HDR physicists as well as the perspective of a new HDR user. Learning Objectives: Summarize national and international safety and staffing guidelines for HDR implementation Discuss the process of afterloader and applicator selection for gynecologic, prostate, breast, interstitial, surface treatments Learn about the use of an audit checklist tool to measure of quality control of a new or existing HDR program Describe the evolving use of checklists within an HDR program.

60 APPLIED LIFE SCIENCES↗

3D Morphological Analysis and Synthesis of Industrial Materials Surfaces

We present the original results pertaining to understanding topographical features on real industrial alloy surfaces. Quite often, such materials are subjected to different thermomechanical treatments with the goal of improving their yield strength, ductility, corrosion resistance, and other properties. Operations of casting, rolling, extruding, and stretching metal invariably leave their distinct “signatures” on the processed materials’ surfaces. It is highly desirable to be able to perform their characterization not in terms of the numerous surface roughness and/or waviness parameters, but rather in terms of the distinctive contributions of such operations. Indeed, if such a quantitative characterization were possible, it would be much easier to introduce corrective actions into the appropriate chain of production operations. We provide such possibility with the “morphological analysis and synthesis” techniques described in the paper. The results can be quantified either using surface topography measurements or studying light scattering from such surfaces. This last capability also gives a quick check of the “morphological similarity” of the “real” and modeled surfaces (images), which is important, e.g., in phase-field simulations. All calculations were performed using the MorphoHawk© software developed by the author and colleagues.

36 MATERIALS SCIENCE↗

SU-C-18A-04: 3D Markerless Registration of Lung Based On Coherent Point Drift: Application in Image Guided Radiotherapy

Purpose: This study evaluated a new probabilistic non-rigid registration method called coherent point drift for real time 3D markerless registration of the lung motion during radiotherapy. Method: 4DCT image datasets Dir-lab (www.dir-lab.com) have been used for creating 3D boundary element model of the lungs. For the first step, the 3D surface of the lungs in respiration phases T0 and T50 were segmented and divided into a finite number of linear triangular elements. Each triangle is a two dimensional object which has three vertices (each vertex has three degree of freedom). One of the main features of the lungs motion is velocity coherence so the vertices that creating the mesh of the lungs should also have features and degree of freedom of lung structure. This means that the vertices close to each other tend to move coherently. In the next step, we implemented a probabilistic non-rigid registration method called coherent point drift to calculate nonlinear displacement of vertices between different expiratory phases. Results: The method has been applied to images of 10-patients in Dir-lab dataset. The normal distribution of vertices to the origin for each expiratory stage were calculated. The results shows that the maximum error of registration between different expiratory phases is less than 0.4 mm (0.38 SI, 0.33 mm AP, 0.29 mm RL direction). This method is a reliable method for calculating the vector of displacement, and the degrees of freedom (DOFs) of lung structure in radiotherapy. Conclusions: We evaluated a new 3D registration method for distribution set of vertices inside lungs mesh. In this technique, lungs motion considering velocity coherence are inserted as a penalty in regularization function. The results indicate that high registration accuracy is achievable with CPD. This method is helpful for calculating of displacement vector and analyzing possible physiological and anatomical changes during treatment.

60 APPLIED LIFE SCIENCES↗

OBSERVATION OF MAGNETIC RECONNECTION AT A 3D NULL POINT ASSOCIATED WITH A SOLAR ERUPTION

Magnetic null has long been recognized as a special structure serving as a preferential site for magnetic reconnection (MR). However, the direct observational study of MR at null-points is largely lacking. Here, we show the observations of MR around a magnetic null associated with an eruption that resulted in an M1.7 flare and a coronal mass ejection. The Geostationary Operational Environmental Satellites X-ray profile of the flare exhibited two peaks at ∼02:23 UT and ∼02:40 UT on 2012 November 8, respectively. Based on the imaging observations, we find that the first and also primary X-ray peak was originated from MR in the current sheet (CS) underneath the erupting magnetic flux rope (MFR). On the other hand, the second and also weaker X-ray peak was caused by MR around a null point located above the pre-eruption MFR. The interaction of the null point and the erupting MFR can be described as a two-step process. During the first step, the erupting and fast expanding MFR passed through the null point, resulting in a significant displacement of the magnetic field surrounding the null. During the second step, the displaced magnetic field started to move back, resulting in a converging inflow and subsequently the MR around the null. The null-point reconnection is a different process from the current sheet reconnection in this flare; the latter is the cause of the main peak of the flare, while the former is the cause of the secondary peak of the flare and the conspicuous high-lying cusp structure.

79 ASTRONOMY AND ASTROPHYSICS↗

Slipping magnetic reconnection during an X-class solar flare observed by SDO/AIA

We present SDO/AIA observations of an eruptive X-class flare of 2012 July 12, and compare its evolution with the predictions of a three-dimensional (3D) numerical simulation. We focus on the dynamics of flare loops that are seen to undergo slipping reconnection during the flare. In the Atmospheric Imaging Assembly (AIA) 131 Å observations, lower parts of 10 MK flare loops exhibit an apparent motion with velocities of several tens of km s{sup –1} along the developing flare ribbons. In the early stages of the flare, flare ribbons consist of compact, localized bright transition-region emission from the footpoints of the flare loops. A differential emission measure analysis shows that the flare loops have temperatures up to the formation of Fe XXIV. A series of very long, S-shaped loops erupt, leading to a coronal mass ejection observed by STEREO. The observed dynamics are compared with the evolution of magnetic structures in the 'standard solar flare model in 3D.' This model matches the observations well, reproducing the apparently slipping flare loops, S-shaped erupting loops, and the evolution of flare ribbons. All of these processes are explained via 3D reconnection mechanisms resulting from the expansion of a torus-unstable flux rope. The AIA observations and the numerical model are complemented by radio observations showing a noise storm in the metric range. Dm-drifting pulsation structures occurring during the eruption indicate plasmoid ejection and enhancement of the reconnection rate. The bursty nature of radio emission shows that the slipping reconnection is still intermittent, although it is observed to persist for more than an hour.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of Proximity of Features on the Damage Threshold During Submicron Additive Manufacturing Via Two-Photon Polymerization

Two-photon polymerization (TPP) is a laser writing process that enables fabrication of millimeter scale three-dimensional (3D) structures with submicron features. In TPP, writing is achieved via nonlinear two-photon absorption that occurs at high laser intensities. Thus, it is essential to carefully select the incident power to prevent laser damage during polymerization. Currently, the feasible range of laser power is identified by writing small test patterns at varying power levels. Here in this paper, we demonstrate that the results of these tests cannot be generalized, because the damage threshold power depends on the proximity of features and reduces by as much as 47% for overlapping features. We have identified that this reduction occurs primarily due to an increase in the single-photon absorptivity of the resin after curing. We have captured the damage from proximity effects via X-ray 3D computed tomography (CT) images of a non-homogenous part that has varying feature density. Part damage manifests as internal spherical voids that arise due to boiling of the resist. We have empirically quantified this proximity effect by identifying the damage threshold power at different writing speeds and feature overlap spacings. In addition, we present a first-order analytical model that captures the scaling of this proximity effect. Based on this model and the experiments, we have identified that the proximity effect is more significant at high writing speeds; therefore, it adversely affects the scalability of manufacturing. The scaling laws and the empirical data generated here can be used to select the appropriate TPP writing parameters.

36 MATERIALS SCIENCE↗

Accelerated fast iterative shrinkage thresholding algorithms for sparsity-regularized cone-beam CT image reconstruction

Purpose: The development of iterative image reconstruction algorithms for cone-beam computed tomography (CBCT) remains an active and important research area. Even with hardware acceleration, the overwhelming majority of the available 3D iterative algorithms that implement nonsmooth regularizers remain computationally burdensome and have not been translated for routine use in time-sensitive applications such as image-guided radiation therapy (IGRT). In this work, two variants of the fast iterative shrinkage thresholding algorithm (FISTA) are proposed and investigated for accelerated iterative image reconstruction in CBCT. Methods: Algorithm acceleration was achieved by replacing the original gradient-descent step in the FISTAs by a subproblem that is solved by use of the ordered subset simultaneous algebraic reconstruction technique (OS-SART). Due to the preconditioning matrix adopted in the OS-SART method, two new weighted proximal problems were introduced and corresponding fast gradient projection-type algorithms were developed for solving them. We also provided efficient numerical implementations of the proposed algorithms that exploit the massive data parallelism of multiple graphics processing units. Results: The improved rates of convergence of the proposed algorithms were quantified in computer-simulation studies and by use of clinical projection data corresponding to an IGRT study. The accelerated FISTAs were shown to possess dramatically improved convergence properties as compared to the standard FISTAs. For example, the number of iterations to achieve a specified reconstruction error could be reduced by an order of magnitude. Volumetric images reconstructed from clinical data were produced in under 4 min. Conclusions: The FISTA achieves a quadratic convergence rate and can therefore potentially reduce the number of iterations required to produce an image of a specified image quality as compared to first-order methods. We have proposed and investigated accelerated FISTAs for use with two nonsmooth penalty functions that will lead to further reductions in image reconstruction times while preserving image quality. Moreover, with the help of a mixed sparsity-regularization, better preservation of soft-tissue structures can be potentially obtained. The algorithms were systematically evaluated by use of computer-simulated and clinical data sets.

60 APPLIED LIFE SCIENCES↗

Cluster Analysis of IRIS Spectroscopic Line Profiles and SDO/AIA EUV Emission in Observations and RMHD Simulations of the Solar Atmosphere

Spatially-resolved observations from the IRIS and SDO/AIA satellites, especially when coupled with realistic 3D RMHD simulations, are a powerful tool for analysis of processes in the solar chromosphere, transition region, and corona. However, the complexity of the data makes understanding the observations and modeling results difficult. In this work, we apply unsupervised clustering algorithms for analysis of observational and synthetic chromospheric Mg II h&k 2796Å&2803Å and transition region C II 1334Å&1335Å line profiles observed by IRIS, and extreme ultraviolet (EUV) emission observed by SDO/AIA, for various types of problems. The synthetic line profiles are computed for simulations of the quiescent solar atmosphere (using the StellarBox and RH1.5 codes). The K-Means clustering algorithm is applied, and the selection of an optimal number of clusters is supported by the average silhouette width technique. We discuss applications of the line profile clustering method to 1) visualization of computational and observational spectroscopic imaging data; 2) understanding of evolutionary trends and behavior patterns of quiet Sun emission and during solar flares; and 3) recognition of heating events and shock waves.

Sadykov, Viacheslav↗

Comparison of radiograph-based texture analysis and bone mineral density with three-dimensional microarchitecture of trabecular bone

Purpose: Hip fracture is a serious health problem and textural methods are being developed to assess bone quality. The authors aimed to perform textural analysis at femur on high-resolution digital radiographs compared to three-dimensional (3D) microarchitecture comparatively to bone mineral density. Methods: Sixteen cadaveric femurs were imaged with an x-ray device using a C-MOS sensor. One 17 mm square region of interest (ROI) was selected in the femoral head (FH) and one in the great trochanter (GT). Two-dimensional (2D) textural features from the co-occurrence matrices were extracted. Site-matched measurements of bone mineral density were performed. Inside each ROI, a 16 mm diameter core was extracted. Apparent density (D{sub app}) and bone volume proportion (BV/TV{sub Arch}) were measured from a defatted bone core using Archimedes' principle. Microcomputed tomography images of the entire length of the core were obtained (Skyscan 1072) at 19.8 {mu}m of resolution and usual 3D morphometric parameters were computed on the binary volume after calibration from BV/TV{sub Arch}. Then, bone surface/bone volume, trabecular thickness, trabecular separation, and trabecular number were obtained by direct methods without model assumption and the structure model index was calculated. Results: In univariate analysis, the correlation coefficients between 2D textural features and 3D morphological parameters reached 0.83 at the FH and 0.79 at the GT. In multivariate canonical correlation analysis, coefficients of the first component reached 0.95 at the FH and 0.88 at the GT. Conclusions: Digital radiographs, widely available and economically viable, are an alternative method for evaluating bone microarchitectural structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-DE-202-00: Image-Guided Interventions: Advances in Intraoperative Imaging, Guidance, and An Emerging Role for Medical Physics in Surgery

At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guided neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41CA192504 Disclosure and CoI: IGI Technologies, small-business partner on the grants.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of TRMM-LIS Lightning and Related Microphysics Using a Cell-Scale Database

Previous studies of tropical lightning activity using Tropical Rainfall Measurement Mission (TRMM) Lightning Imaging Sensor (LIS) data performed analyses of lightning behavior over mesoscale "feature" scales or over uniform grids. In order to study lightning and the governing ice microphysics intrinsic to thunderstorms at a more process-specific scale (i.e., the scale over which electrification processes and lightning occur in a "unit" thunderstorm), a new convective cell-scale database was developed by analyzing and refining the University of Utah's Precipitation Features database and retaining precipitation data parameters computed from the TRMM precipitation radar (PR), microwave imager (TMI) and LIS instruments. The resulting data base was to conduct a limited four-year study of tropical continental convection occurring over the Amazon Basin, Congo, Maritime Continent and the western Pacific Ocean. The analysis reveals expected strong correlations between lightning flash counts per cell and ice proxies, such as ice water path, minimum and average 85GHz brightness temperatures, and 18dBz echo top heights above the freezing level in all regimes, as well as regime-specific relationships between lighting flash counts and PR-derived surface rainfall rates. Additionally, radar CFADs were used to partition the 3D structure of cells in each regime at different flash counts. The resulting cell-scale analyses are compared to previous mesoscale feature and gridded studies wherever possible.

Leroy, Anita↗

Enabling Highly Efficient Capsule Networks Processing Through A PIM-Based Architecture Design

In recent years, the CNNs have achieved great successes in the image processing tasks, e.g., image recognition and object detection. Unfortunately, traditional CNN's classication is found to be easily misled by increasingly complex image features due to the usage of pooling operations, hence unable to preserve accurate position and pose information of the objects. To address this challenge, a novel neural network structure called Capsule Network has been proposed, which introduces equivariance through capsules to signicantly enhance the learning ability for image segmentation and object detection. Due to its requirement of performing a high volume of matrix operations, CapsNets have been generally accelerated on modern GPU platforms that provide highly optimized software library for common deep learning tasks. However, based on our performance characterization on modern GPUs, CapsNets exhibit low effciency due to the special program and execution features of their routing procedure, including massive unshareable intermediate variables and intensive syn- chronizations, which are very dicult to optimize at software level. To address these challenges, we propose a hybrid computing architecture design named PIM-CapsNet. It preserves GPU's on-chip computing capability for accelerating CNN types of layers in CapsNet, while pipelining with an off-chip in-memory acceleration solution that effectively tackles routing procedure's ineffciency by leveraging the processing-in-memory capability of today's 3D stacked memory. Using routing procedure's inherent parallellization feature, our design enables hierarchical improvements on CapsNet inference effciency through minimizing data movement and maximizing parallel processing in memory. Evaluation results demonstrate that our proposed design can achieve substantial improvement on both performance and energy savings for CapsNet inference, with almost zero accuracy loss. The results also suggest good performance scalability in optimizing the routing procedure with increasing network size.

Zhang, Xingyao↗

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts

X-ray Computed Tomography (XCT) has been utilized to image and characterize compacts from the combined third and fourth irradiation of the Advanced Gas Reactor (AGR) Program, AGR-3/4, fuel. The experiment contained tristructural isotropic (TRISO)-coated fuel particles as well as designed-to-fail (DTF) fuel particles. Two irradiated compacts, representing the lower and higher range of AGR-3/4 burnup (4.85% and 14.92% fissions per initial heavy metal atom FIMA) were examined. These represent the first known highly irradiated TRISO fuel compacts to be examined via X-ray CT. Additionally, two unirradiated compacts from the same production batch as the examined irradiation compacts were also imaged for a baseline comparison. As XCT of irradiated TRISO compacts is not a commonly implemented characterization technique, a significant portion of the report focuses on developed methodology and imaging conditions. A specialized sample shielding device was developed and fabricated specifically to limit received dose to staff during sample preparation for XCT and to minimize excess gamma radiation dose to sensitive electronic components with the utilized X-ray system. Significant penetration through the uranium oxycarbide fuel kernels by significantly hardening the X-ray beam with specialized proprietary filters acquired from Carl Zeiss NTS Ltd. The filter utilized resulted in an average X ray photon energy of ~110 keV which approaches uranium’s K-edge (~115 keV), maximizing penetration for a microfocus X-ray source. The gamma-radiation emitted from the irradiated AGR-3/4 TRISO compacts, has the same properties and mechanisms for interaction with matter as X-rays, thus the detection of gamma-radiation by the utilized X-ray detectors was initially a concern. However, although ?-rays did produce an observable signal on the X-ray detector, its contribution to the overall imaging results appeared negligible upon 3D reconstruction. The neglibile impact on the resulting 3D reconstructed volumes were likely the result of: (1) a significantly lower detection efficiency for ?-rays relative to X-rays; (2) An X-ray flux at the detector several orders of magnitude higher than that of the impinging ?-rays from the irradiated compacts. These results suggest that irradiated compacts with significantly higher radiation fields can be examined in the future if an acceptable route for sample handling and preparation can be determined. Additionally, the 3D imaging results of XCT can provide a valuable means of assessing compacts. While in many ways complimentary to traditional post irradiation examination techniques such as optical ceramography, XCT can provide additional insight into compact features traditionally difficult to discern directly from cross-sectional imaging alone. Preliminary analyses on kernel size, morphology (aspect ratio and sphericity), and kernel orientation were presented. Sphericity, a simple morphological shape descriptor, was utilized to screen for kernel extrusions within the high burnup compact. The number of kernel extrusions identified via XCT represented an approximate two-fold increase from the quantity of extruded particles observed (via optical ceramography) in adjacent compacts from the same irradiation capsule. While numerical analysis of the compact datasets was highly preliminary, initial results show promise for providing complimentary metrics to current AGR-3/4 PIE and potentially additional insight into the processes driving TRISO fuel degradation during reactor operation. Additional analyses to be performed at a later date include a more detailed examination of kernel size, kernel sphericity (and observed kernel extrusions), and sphericity. Given all particles can be observed in a single data volume possible correlation of spatial position with observed kernel features will also be made at a later date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Vehicle Localization in 3D World Coordinates Using Single Camera at Traffic Intersection

Optimizing traffic control systems at traffic intersections can reduce the network-wide fuel consumption, as well as emissions of conventional fuel-powered vehicles. While traffic signals have been controlled based on predetermined schedules, various adaptive signal control systems have recently been developed using advanced sensors such as cameras, radars, and LiDARs. Among these sensors, cameras can provide a cost-effective way to determine the number, location, type, and speed of the vehicles for better-informed decision-making at traffic intersections. In this research, a new approach for accurately determining vehicle locations near traffic intersections using a single camera is presented. For that purpose, a well-known object detection algorithm called YOLO is used to determine vehicle locations in video images captured by a traffic camera. YOLO draws a bounding box around each detected vehicle, and the vehicle location in the image coordinates is converted to the world coordinates using camera calibration data. During this process, a significant error between the center of a vehicle’s bounding box and the real center of the vehicle in the world coordinates is generated due to the angled view of the vehicles by a camera installed on a traffic light pole. As a means of mitigating this vehicle localization error, two different types of regression models are trained and applied to the centers of the bounding boxes of the camera-detected vehicles. The accuracy of the proposed approach is validated using both static camera images and live-streamed traffic video. Based on the improved vehicle localization, it is expected that more accurate traffic signal control can be made to improve the overall network-wide energy efficiency and traffic flow at traffic intersections.

47 OTHER INSTRUMENTATION↗

Optimization of a parallel hole collimator/CdZnTe gamma-camera architecture for scintimammography

Purpose: Small field-of-view CdZnTe (CZT) gamma cameras are increasingly studied for breast lesion detection to complement mammography or ultrasonographic findings. However, in classical collimation configurations, they remain limited by the trade-off between spatial resolution and sensitivity. The HiSens architecture was proposed to overcome these limitations. Using an accurate 3D localization of the interactions inside the detector, this architecture leads to a gain in sensitivity without loss in spatial resolution. In this article, the relevance of the HiSens architecture for planar scintimammography is studied. Methods: A detective quantum efficiency (DQE) computation method is developed and used to optimize the dimensioning of a parallel hole collimator dedicated to scintimammography. Based on the DQE curves, the impact of the collimator-to-detector distance is studied. Two algorithms are proposed to combine data acquired with different collimator-to-detector distances. Results: It is shown that CZT detector virtual pixelization increases system sensitivity by 3.3 while preserving a standard LEHR spatial resolution. The introduction of a gap between the CZT detector and the collimator is useful to modulate the DQE curve shape. The combination of data acquired using different gaps in the image formation process leads to enhanced restoration of the frequency content of the images, resulting in image contrast and spatial resolution improvements. Conclusions: Acquisition duration or injected activity could be markedly reduced if the HiSens architecture with an appropriate collimator-detector gap were used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗