Probes for multidimensional nanospectroscopic imaging and methods of fabrication thereof

This disclosure provides systems, methods, and apparatus related to probes for multidimensional nanospectroscopic imaging. In one aspect, a method includes providing a transparent tip comprising a dielectric material. A four-sided pyramidal-shaped structure is formed at an apex of the transparent tip using a focused ion beam. Metal layers are deposited over two opposing sides of the four-sided pyramidal-shaped structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BEAM DYNAMICS STUDIES OF A HIGH-REPETITION RATE LINAC-DRIVER FOR A 4TH GENERATION LIGHT SOURCE

We present recent progress toward the design of a super-conducting linac driver for a high-repetition rate FEL-based soft x-ray light source. The machine is designed to accept beams generated by the APEX photo-cathode gun operating with MHz-range repetition rate and deliver them to an array of SASE and seeded FEL beamlines. We review the current baseline design and report results of beam dynamics studies.

43 PARTICLE ACCELERATORS↗

Method for using a hydrocyclone for cryogenic gas vapor separation

A method for separating a vapor from a carrier gas is disclosed. A hydrocyclone is provided with one or more nozzles on the wall of the hydrocyclone. A cryogenic liquid is provided to the tangential feed inlet at a velocity that induces a tangential flow and a cyclone vortex in the hydrocyclone. The carrier gas is injected into the hydrocyclone through the one or more nozzles. The vapor dissolves, condenses, desublimates, or a combination thereof, forming a vapor-depleted carrier gas and a vapor-enriched cryogenic liquid. The vapor-depleted gas is drawn through the vortex finder while the vapor-enriched cryogenic liquid is drawn through the apex nozzle outlet. In this manner, the vapor is removed from the carrier gas.

42 ENGINEERING↗

Method for using an air-sparged hydrocyclone for cryogenic gas vapor separation

A method for separating a vapor from a carrier gas is disclosed. An air-sparged hydrocyclone is provided with a porous sparger covered by an outer gas plenum. A cryogenic liquid is provided to the tangential feed inlet at a velocity that induces a tangential flow and a cyclone vortex in the cyclone. The carrier gas is injected into the air-sparged hydrocyclone through the porous sparger. The vapor dissolves, condenses, desublimates, or a combination thereof, forming a vapor-depleted carrier gas and a vapor-enriched cryogenic liquid. The vapor-depleted gas is drawn through a vortex finder while the vapor-enriched cryogenic liquid is drawn through an apex nozzle outlet. In this manner, the vapor is removed from the carrier gas.

Baxter, Larry↗

Hydrocyclone for cryogenic gas-vapor separation

A hydrocyclone for separating a vapor from a carrier gas is disclosed. The hydrocyclone comprises one or more nozzles. A cryogenic liquid is injected to a tangential feed inlet at a velocity that induces a tangential flow and a cyclone vortex in the hydrocyclone. The carrier gas is injected into the cryogenic liquid, causing the vapor to dissolve, condense, desublimate, or a combination thereof, forming a vapor-depleted carrier gas and a vapor-enriched cryogenic liquid. The vapor-depleted carrier gas is drawn through a vortex finder and the vapor-enriched cryogenic liquid is drawn through an apex nozzle outlet. In this manner, the vapor is removed from the carrier gas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Air-sparged hydrocyclone for cryogenic gas vapor separation

An air-sparged hydrocyclone for separating a vapor from a carrier gas is disclosed. The cyclone comprises a porous sparger covered by an outer gas plenum. A cryogenic liquid is injected to a tangential feed inlet at a velocity that induces a tangential flow and a cyclone vortex in the air-sparged hydrocyclone. The carrier gas is injected into the cyclone through the porous sparger. The vapor dissolves, condenses, desublimates, or a combination thereof, forming a vapor-depleted carrier gas and a vapor-enriched cryogenic liquid. The vapor-depleted carrier gas is drawn through a vortex finder and the vapor-enriched cryogenic liquid is drawn through an apex nozzle outlet. In this manner, the vapor is removed from the carrier gas.

Baxter, Larry↗

Tamper-resistant fastener

A tamper-resistant threaded fastener including a circular head having a slot formed in the head transverse to the longitudinal axis, the slot having an enlarged region intermediate an apex and a base of the slot. A cap member includes a head having a drive feature formed therein, the head extending to a first shank portion, extending to an enlarged second shank portion, extending to a foot. The cap member is insertable in the slot only from a direction transverse to the longitudinal axis. During rotational installation of the fastener and cap member in a threaded counterbored opening for securing a barrier for protecting an asset, the foot shears inside the slot at a predetermined rotational drive force, the cap member being rotatable in the opening and protectively covering the fastener head.

Neidigk, Stephen↗

New experimental results for a vector boson A

The search for a new vector boson, $A'$, in the test run of A' EXperiment (APEX) results in a limit for a weak coupling $\alpha' \ga 10^{-6} \alpha$ to electrons ($\alpha=e^2/4\pi$) in the mass range 175 MeV $< m_{A'} <$ 250 MeV. New vector bosons with such small couplings arise naturally from a small kinetic mixing of the ``dark photon'' $A'$ with the photon --- one of the very few ways in which new forces can couple to the Standard Model --- and have received considerable attention as an explanation of various dark matter related anomalies. $A'$ bosons are produced by radiation off an electron beam, and could appear as narrow resonances with small production cross-section in the trident $e^+e^-$ spectrum. We plan to search for the $A'$ by using the CEBAF electron beam at energies of $\approx$ 1--4 GeV incident on $0.5-10\%$ radiation length multi-foil Tungsten targets, and measure the resulting $e^+e^-$ pairs using the High Resolution Spectrometers and a septum magnet in Hall A at Jefferson Lab. With a 33-day run, the experiment will achieve very good sensitivity because the statistics of $e^+e^-$ pairs will be $\sim 10,000$ times larger in the explored mass range than in any previous search for the $A'$ boson. This talk will discuss the experiment and present the

Wojtsekhowski, Bogdan↗

Experimental search for a new vector boson A'

The A? EXperiment (APEX) will search for a new vector boson, A?, with weak coupling ?? & 6 × 10?8? to electrons (? = e2/4?) in the mass range 65 MeV < mA? < 550 MeV. New vector bosons with such small couplings arise naturally from a small kinetic mixing of the ?dark photon? A? with the photon ? one of the very few ways in which new forces can couple to the Standard Model ? and have received considerable attention as an explanation of various dark matter related anomalies. A? bosons are produced by radiation off an electron beam, and could appear as narrow resonances with small production cross-section in the trident e+e? spectrum. We plan to search for the A? by using the CEBAF electron beam at energies of ? 1?4 GeV incident on 0.5?10% radiation length multi-foil Tungsten targets, and measure the resulting e+e? pairs using the High Resolution Spectrometers and a septum magnet in Hall A at Jefferson Lab. With a 33-day run, the experiment will achieve very good sensitivity because the statistics of e + e? pairs will be ? 10, 000 times larger in the explored mass range than any previous search for the A? boson. This talk will discuss the experiment and present the results of a pilot run.

Wojtsekhowski, Bogdan↗

High-Performance Accelerator Modeling: Toward Improving Controls and Diagnostics for High-Brightness Beams in Experiment

One of the main charges of beam physics is to improve the overall beam quality delivered to experiments and applications, which is generally quantified by the beam brightness. High brightness beams have numerous applications, including x-ray free electron lasers and ultrafast electron diffraction (UED). To these ends, this thesis details efforts to use high-performance models --- high-fidelity models that execute quickly --- for controls and diagnostics. To demonstrate the generality of these techniques, this thesis focuses on three of the most successful photoinjector designs currently used worldwide: the UCLA/SLAC/BNL-type high-gradient S-band gun, the continuous-wave high-repetition rate VHF APEX gun and the L-band DESY-PITZ-type gun. Work will be shown from Pegasus (UCLA), HiRES (LBNL) and FAST (FNAL).Specifically, data-driven models for online virtual diagnostics are presented, in this case, in the context of UED at HiRES, leading to a temporal resolution improvement. Methods for improving the fidelity of physics-based models are discussed, with examples at HiRES, Pegasus and FAST. Markov-chain Monte Carlo analysis is applied to match simulations, in the context of photocathode studies at HiRES and Pegasus. Lastly, the augmentation of online model-based predictions with model-independent optimization is explored in a fluctuating environment at Pegasus and HiRES. A central theme of this dissertation is working with parameter fluctuations when modeling an accelerator beamline. Long-term drifts and shot-to-shot jitter exist in every accelerator to a varying degree and therefore play an important role in every chapter of this dissertation. This thesis attempts to address the issues associated with these fluctuations when trying to develop faithful model representations of the system.

43 PARTICLE ACCELERATORS↗

Selective Detection of Diglycolamide Diastereomers By Metal-Ligand Cluster Formation

Introduction (120 words): Differentiation of isomers using mass spectrometry is a challenge, as these species tend to produce ions of identical mass-to-charge ratio. Therefore, separation with mass spectrometry must rely on chemical differences between isomeric species. Separation of stereoisomers is especially challenging, as these species often have very similar chemistry. However, recent investigations of the solvent extraction behavior of diastereomers of diglycolamide molecules have shown that different stereoisomers can have significantly different lanthanide extraction efficiencies. These studies showed that the R,S stereoisomer of 2,2'-oxybis(N,N-dioctylpropanamide efficiently extracts lanthanides, while the S,S stereoisomer does not. Thus, gas-phase metal complexation may provide a pathway for differentiating these species using mass spectrometry. Methods (120 words): Europium, samarium, and holmium clusters with the R,S, and the S,S diastereomers of 2,2'-oxybis(N,N-didecylpropanamide (trivially tetradecyl diglycolamide, or mTDDGA) were generated in gas-phase using the electrospray ionization source of a Bruker (Billerica, MA, USA) micrOTOF-Q II quadrupole time-of-flight mass spectrometer. Solutions of aqueous lanthanide nitrate and diglycolamide ligands in 2-propanol were added to 50%:50% by volume acetonitrile:2-propanol to generate the spray solutions. Ligand concentration was maintained at approximately 6 µM, while lanthanide concentration was maintained at either 6 µM or 30 µM . High resolution, high mass accuracy spectra were recorded using the time-of-flight. Mass accuracy was ensured using external calibration with Agilent (Santa Clara, CA, USA) ESI-L Low Concentration tuning mix. Preliminary data (300 words): Electrospray of solutions containing only R,S-mTDDGA or S,S-m-TDDGA yield abundant peaks at m/z= 721.7, corresponding to [mTDDGA+H]+1, m/z = 743.7, corresponding to [mTDDGA+Na]+1, and m/z = 1464.4, corresponding to the sodium-bound dimer, [Na(mTDDGA)2]+1. Spray of solutions containing 6 µM europium (Eu) with 3 µM R,S-mTDDGA produced an abundant cluster ion with an isotopic envelope centered at m/z=772.0, corresponding to [Eu(R,S-mTDDGA)3]3+. Europium-containing cluster ions with isotopic envelopes apexing at m/z = 1012.3 and 1189.0 correspond to the [Eu(R,S-mTDDGA)4]3+ and [Eu(R,S-mTDDGA)5]3+ cluster ions, respectively. Protonated and sodiated R,S-mTDDGA are present as well, along with the sodium-bound dimer. In contrast, spray of solutions containing 6 µM europium (Eu) with 3 µM S,S-mTDDGA diastereomer yielded only protonated and sodiated ligand ions; no Eu- S,S-mTDDGA ions were present. This mirrors the solution-phase behavior, where the S,S diestereomer extracts lanthanides with significantly less efficiency than the R,S diestereomer. Experiments with holmium and samarium yielded the same results. Increasing the lanthanide concentration to 30 µM resulted in limited formation of lanthanide-S,S-mTDDGA clusters. However, the abundance of the [Ln(S,S-mTDDGA)3]3+ clusters remained low compared to the abundance of the protonated and sodiated ligand. Additionally, the abundance of the [Ln(R,S-mTDDGA)3]3+ cluster ion was significantly higher than that of the protonated and sodiated ligand in experiments with spray solutions containing 30 µM lanthanide with R,S-mTDDA, supporting the hypothesis that R,S-mTDDGA has a higher intrinsic affinity for the lanthanides than S,S-mTDDGA. Thus, the intrinsic complexation with lanthanides appears to offer a route to differentiate diglycolamide diestereomers in the gas-phase. Novelty (20): Stereoisomers can be differentiated in the gas phase by exploitation of differences in metal complexation chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spin microscope based on optically detected magnetic resonance

The invention relates to scanning magnetic microscope which has a photoluminescent nanoprobe implanted in the tip apex of an atomic force microscope (AFM), a scanning tunneling microscope (STM) or a near-field scanning optical microscope (NSOM) and exhibits optically detected magnetic resonance (ODMR) in the vicinity of unpaired electron spins or nuclear magnetic moments in the sample material. The described spin microscope has demonstrated nanoscale lateral resolution and single spin sensitivity for the AFM and STM embodiments.

Berman, Gennady P.↗

STRESS CORROSION CRACKING IN TEAR DROP SPECIMENS

Laboratory tests were conducted to investigate the stress corrosion cracking (SCC) of 304L stainless steel used to construct the containment vessels for the storage of plutonium-bearing materials. The tear drop corrosion specimens each with an autogenous weld in the center were placed in contact with moist plutonium oxide and chloride salt mixtures. Cracking was found in two of the specimens in the heat affected zone (HAZ) at the apex area. Finite element analysis was performed to simulate the specimen fabrication for determining the internal stress which caused SCC to occur. It was found that the tensile stress at the crack initiation site was about 30% lower than the highest stress which had been shifted to the shoulders of the specimen due to the specimen fabrication process. This finding appears to indicate that the SCC initiation took place in favor of the possibly weaker weld/base metal interface at a sufficiently high level of background stress. The base material, even subject to a higher tensile stress, was not cracked. The relieving of tensile stress due to SCC initiation and growth in the HAZ and the weld might have foreclosed the potential for cracking at the specimen shoulders where higher stress was found.

36 MATERIALS SCIENCE↗

Structure of Antibody F425-B4e8 in Complex With a V3 Peptide Reveals a New Binding Mode for Hiv-1 Neutralization

F425-B4e8 (B4e8) is a monoclonal antibody isolated from a human immunodeficiency virus type 1 (HIV-1)-infected individual that recognizes the V3 variable loop on the gp120 subunit of the viral envelope spike. B4e8 neutralizes a subset of HIV-1 primary isolates from subtypes B, C and D, which places this antibody among the very few human anti-V3 antibodies with notable cross-neutralizing activity. Here, the crystal structure of the B4e8 Fab fragment in complex with a 24-mer V3 peptide (RP142) at 2.8 A resolution is described. The complex structure reveals that the antibody recognizes a novel V3 loop conformation, featuring a five-residue alpha-turn around the conserved GPGRA apex of the beta-hairpin loop. In agreement with previous mutagenesis analyses, the Fab interacts primarily with V3 through side-chain contacts with just two residues, Ile(P309) and Arg(P315), while the remaining contacts are to the main chain. The structure helps explain how B4e8 can tolerate a certain degree of sequence variation within V3 and, hence, is able to neutralize an appreciable number of different HIV-1 isolates.

36 MATERIALS SCIENCE↗

Spin microscope based on optically detected magnetic resonance

The invention relates to scanning magnetic microscope which has a photoluminescent nanoprobe implanted in the tip apex of an atomic force microscope (AFM), a scanning tunneling microscope (STM) or a near-field scanning optical microscope (NSOM) and exhibits optically detected magnetic resonance (ODMR) in the vicinity of impaired electron spins or nuclear magnetic moments in the sample material. The described spin microscope has demonstrated nanoscale lateral resolution and single spin sensitivity for the AFM and STM embodiments.

Berman, Gennady P↗

Spin microscope based on optically detected magnetic resonance

The invention relates to scanning magnetic microscope which has a photoluminescent nanoprobe implanted in the tip apex of an atomic force microscope (AFM), a scanning tunneling microscope (STM) or a near-field scanning optical microscope (NSOM) and exhibits optically detected magnetic resonance (ODMR) in the vicinity of unpaired electron spins or nuclear magnetic moments in the sample material. The described spin microscope has demonstrated nanoscale lateral resolution and single spin sensitivity for the AFM and STM embodiments.

47 OTHER INSTRUMENTATION↗

Tapping mode microwave impedance microscopy

We report tapping mode microwave impedance imaging based on atomic force microscope platforms. The shielded cantilever probe is critical to localize the tip-sample interaction near the tip apex. The modulated tip-sample impedance can be accurately simulated by the finite-element analysis and the result agrees quantitatively to the experimental data on a series of thin-film dielectric samples. The tapping mode microwave imaging is also superior to the contact mode in that the thermal drift in a long time scale is totally eliminated and an absolute measurement on the dielectric properties is possible. We demonstrated tapping images on working nanodevices, and the data are consistent with the transport results.

36 MATERIALS SCIENCE↗

Spin microscope based on optically detected magnetic resonance

The invention relates to scanning magnetic microscope which has a photoluminescent nanoprobe implanted in the tip apex of an atomic force microscope (AFM), a scanning tunneling microscope (STM) or a near-field scanning optical microscope (NSOM) and exhibits optically detected magnetic resonance (ODMR) in the vicinity of unpaired electron spins or nuclear magnetic moments in the sample material. The described spin microscope has demonstrated nanoscale lateral resolution and single spin sensitivity for the AFM and STM embodiments.