Search NASA⌕ Search

SEARCH · Search NASA

Results for “APR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Hazards of Lunar Surface Exploration: Determining the Immunogenicity/Allergenicity of Lunar Dust

There are multiple Apollo program reports of lunar dust (LD) exposure leading to significant upper respiratory symptoms in select crewmembers. Possible mechanisms include particulate irritation, oxidization and release of noxious gas, or legitimate adaptive immune-mediated response. Although sterile non-protein matter would not be expected to be an allergen, one Apollo flight surgeon reported increasing symptoms upon repeated exposure, with associated eosinophilia indicative of allergy (*Acta Astronautica. 2008 63 (7–10): 980–987). Many ISS crews display a pattern of persistent immune system dysregulation and latent virus reactivation (NPJ Microgravity. 2015 Sep 3; 1:15013; NPJ Microgravity. 2017 Apr 12; 3:11). Some ISS crews manifest atypical respiratory and/or dermatitis symptoms which could have an allergic pathogenesis (J Allergy Clin. Immunol. Pract. 2016 Jul-Aug; 4(4):759-762.e8). It is logical to anticipate crew immune dysregulation would worsen during prolonged deep space missions. Planetary surface hazards will only complicate crew health risks. This study hypothesizes that LD exposure can alter susceptible individuals’ immune responses such that repeated exposure will elicit an IgE mediated allergic response either to the LD itself or concomitant antigen exposure during spaceflight. This will adversely increase clinical and operational impacts for long-duration lunar astronauts and affect countermeasure requirements for surface vehicles. Specific aims for this study are (1) Does in vitro LD exposure result in increased histamine from human peripheral blood basophils? (2) Can LD impact the capacity of CD4+ helper and/or CD19+ B-cell mediated IgE production? To address these questions, a set of in-vitro cell culture experiments will be employed (short and long term) using human peripheral blood mononuclear cells (PBMC) and basophils from both atopic and non-atopic individuals, as well as established human basophil and mast cell lines. Cells will be co-cultured with cellular mitogens, common recall antigens (tetanus, Der p1), nickel (as a possible allergenic component of LD), with or without graded amounts of LD, to study whether LD exposure for varying time intervals will alter the generation of selective immune responses associated with clinical allergic reactions. Measured outputs include supernatant-derived IgE, tryptase, histamine and selected cytokine levels. Cellular activation will be monitored by assessing activation markers via flow cytometry. EM/x-ray analysis will be used to determine cellular interactions with dust particles. The minimal amount of LD (Apollo 14 dust) and controls/simulants have been requested. This study, originally planned as an FY20/21 activity, was delayed due to the COVID pandemic. It is now scheduled to be performed during FY22.

Brian Crucian↗

Hazards of Lunar Surface Exploration: Determining the Immunogenicity/Allergenicity of Lunar Dust

Although infrequent, there have been Apollo program reports of lunar dust (LD) exposure leading to notable upper respiratory symptoms in select crewmembers. Possible mechanisms include particulate irritation, oxidization and release of noxious gas, or legitimate adaptive immune-mediated response. Although sterile non-protein matter would not be expected to be an allergen, one Apollo flight surgeon reported increasing symptoms upon repeated exposure with associated eosinophilia, indicative of allergy (*Acta Astronautica. 2008 63 (7–10): 980–987). Many ISS crews display a pattern of persistent immune system dysregulation and latent virus reactivation (NPJ Microgravity. 2015 Sep 3; 1:15013; NPJ Microgravity. 2017 Apr 12; 3:11). Some ISS crews manifest atypical respiratory and/or dermatitis symptoms which could have an allergic pathogenesis (J Allergy Clin. Immunol. Pract. 2016 Jul-Aug; 4(4):759-762.e8). It is logical to anticipate crew immune dysregulation would worsen during prolonged deep space missions. Planetary surface hazards will only complicate crew health risks. This study with investigate if LD exposure will elicit an IgE mediated allergic response either to the LD itself or concomitant antigen exposure during spaceflight. Allergic reactivity could adversely increase clinical and operational impacts for long-duration lunar astronauts and affect countermeasure requirements for surface vehicles. Specific aims for this study are to answer two questions: (1) Does in vitro LD exposure result in increased histamine from human peripheral blood basophils? (2) Can LD impact the capacity of CD4+ T helper and/or CD19+ B-cell mediated IgE production? To address these questions, after the proposal and selection by NASA, our laboratory has separately requested and been approved for receipt of actual LD samples from the Apollo 16 mission. These samples will be used during the study to complete the proposed set of in vitro cell culture experiments (short and long term), using human peripheral blood mononuclear cells (PBMC) and basophils from both atopic and non-atopic individuals. Cells will be co-cultured with cellular mitogens, common recall antigens (Der p1), fine ground silica quartz (as a possible allergenic component of LD), or LD, to study whether LD exposure for varying time intervals will alter the generation of selective immune responses associated with clinical allergic reactions. Measured outputs include supernatant-derived IgE, tryptase, histamine, and selected cytokine levels. Cellular activation will be monitored by assessing activation markers via flow cytometry. EM/x-ray analysis will be used to determine cellular interactions with dust particles. A series of validation experiments was initiated in FY22 once the delivery of LD was received. Based on initial experimental findings, we are optimizing the culture conditions, LD concentrations, and refining our other protocol stimuli.

Audrie A. Colorado↗

Hazards of Lunar Surface Exploration: Determining the Immunogenicity/Allergenicity of Lunar Dust

Although infrequent, there have been Apollo program reports of lunar dust (LD) exposure leading to notable upper respiratory symptoms in select crewmembers. Possible mechanisms include particulate irritation, oxidization and release of noxious gas, or legitimate adaptive immune-mediated response. Although sterile non-protein matter would not be expected to be an allergen, one Apollo flight surgeon reported increasing symptoms upon repeated exposure with associated eosinophilia, indicative of allergy (*Acta Astronautica. 2008 63 (7–10): 980–987). Many ISS crews display a pattern of persistent immune system dysregulation and latent virus reactivation (NPJ Microgravity. 2015 Sep 3; 1:15013; NPJ Microgravity. 2017 Apr 12; 3:11). Some ISS crews manifest atypical respiratory and/or dermatitis symptoms which could have an allergic pathogenesis (J Allergy Clin. Immunol. Pract. 2016 Jul-Aug; 4(4):759-762.e8). It is logical to anticipate crew immune dysregulation would worsen during prolonged deep space missions. Planetary surface hazards will only complicate crew health risks. This study with investigate if LD exposure will elicit an IgE mediated allergic response either to the LD itself or concomitant antigen exposure during spaceflight. Allergic reactivity could adversely increase clinical and operational impacts for long-duration lunar astronauts and affect countermeasure requirements for surface vehicles. Specific aims for this study are to answer two questions: (1) Does in vitro LD exposure result in increased histamine from human peripheral blood basophils? (2) Can LD impact the capacity of CD4+ T helper and/or CD19+ B-cell mediated IgE production? To address these questions, after the proposal and selection by NASA, our laboratory has separately requested and been approved for receipt of actual LD samples from the Apollo 16 mission. These samples will be used during the study to complete the proposed set of in vitro cell culture experiments (short and long term), using human peripheral blood mononuclear cells (PBMC) and basophils from both atopic and non-atopic individuals. Cells will be co-cultured with cellular mitogens, common recall antigens (Der p1), fine ground silica quartz (as a possible allergenic component of LD), or LD, to study whether LD exposure for varying time intervals will alter the generation of selective immune responses associated with clinical allergic reactions. Measured outputs include supernatant-derived IgE, tryptase, histamine, and selected cytokine levels. Cellular activation will be monitored by assessing activation markers via flow cytometry. EM/x-ray analysis will be used to determine cellular interactions with dust particles. A series of validation experiments was initiated in FY22 once the delivery of LD was received. Based on initial experimental findings, we are optimizing the culture conditions, LD concentrations, and refining our other protocol stimuli.

immunology↗

Parker Solar Probe: Four Years of Discoveries at Solar Cycle Minimum

Launched on 12 Aug. 2018, NASA’s Parker Solar Probe had completed 13 of its scheduled 24 orbits around the Sun by Nov. 2022. The mission’s primary science goal is to determine the structure and dynamics of the Sun’s coronal magnetic field, understand how the solar corona and wind are heated and accelerated, and determine what processes accelerate energetic particles. Parker Solar Probe returned a treasure trove of science data that far exceeded quality, significance, and quantity expectations, leading to a significant number of discoveries reported in nearly 700 peer-reviewed publications. The first four years of the 7-year primary mission duration have been mostly during solar minimum conditions with few major solar events. Starting with orbit 8 (i.e., 28 Apr. 2021), Parker flew through the magnetically dominated corona, i.e., sub-Alfvénic solar wind, which is one of the mission’s primary objectives. In this paper, we present an overview of the scientific advances made mainly during the first four years of the Parker Solar Probe mission, which go well beyond the three science objectives that are: (1) Trace the flow of energy that heats and accelerates the solar corona and solar wind; (2) Determine the structure and dynamics of the plasma and magnetic fields at the sources of the solar wind; and (3) Explore mechanisms that accelerate and transport energetic particles.

Sun↗

Impact of COVID-19-related Air Traffic Reductions on the Coverage and Radiative Effects of Linear Persistent Contrails over Conterminous United States and Surrounding Oceanic Routes

The radiative effects of the large-scale air traffic slowdown during Apr and May 2020 due to the international response to the COVID-19 pandemic are estimated by comparing the coverage (CC), optical properties, and radiative forcing of persistent linear contrails over the conterminous United States and two surrounding oceanic air corridors during the slowdown period and a similar baseline period during 2018 and 2019 when air traffic was unrestricted. The detected CC during the slowdown period decreased by an area-averaged mean of 41% for the three analysis boxes. The retrieved contrail optical properties were mostly similar for both periods. Total shortwave contrail radiative forcings during the slowdown were 34 and 42% smaller for Terra and Aqua, respectively. The corresponding differences for longwave contrail radiative forcing were 33% for Terra and 40% for Aqua. To account for the impact of any changes in the atmospheric environment between baseline and slowdown periods on detected CC amounts, the contrail formation potential (CFP) was computed from reanalysis data. In addition, a filtered CFP (fCFP) was also developed to account for factors that may affect contrail formation and visibility of persistent contrails in satellite imagery. The CFP and fCFP were combined with air traffic density data to create empirical models that estimated CC during the baseline and slowdown periods and were compared to the detected CC. The models confirm that decreases in CC and radiative forcing during the slowdown period were mostly due to the reduction in air traffic, and partly due to environmental changes.

contrails↗

Investigation of Cloud Interior Structure Using a Tomographic Technique Based on Radon Transform. Application to the Measurements Made by the Research Scanning Polarimeter During CAMP2Ex

The Research Scanning Polarimeter (RSP) is an airborne along-track scanner measuring the polarized and total reflectances in 9 spectral channels. The RSP's uniquely high angular resolution coupled with the high frequency of measurements allows for characterization of liquid-water cloud droplet sizes using the rainbow structure observed in the polarized reflectance measurements. The RSP observations also provide for derivation of 2D field of extinction coefficient inside the cloud using a tomographic technique. This technique utilizes the family of cloud shapes derived using "cutout" technique and corresponding to a number of thresholds in total reflectance (separating bright cloud from its darker background). These shapes can be interpreted as level curves of an abstract "reflectance density", which is then used for derivation of the directional cloud optical thickness (dCOT) tomogram. The latter is a collection of dCOTs parameterized by the angles and offsets of the corresponding view rays (chords) relative to the cloud center. After this, the inverse Radon Transform (the mathematical basis of the X-ray com-puter tomography) is applied to the dCOT tomogram yielding 2D spatial distribution of the extinction coefficient. The later can be converted into droplet number concentration using the droplet size profiles derived from the RSP's polarized reflectance measurements. After tests on synthetic data this technique was applied to real RSP measurements from NASA's Cloud, Aerosol and Monsoon Processes Philippines Experiment (CAMP2Ex) conducted in the vicinity of the Philippines during the Southwest Monsoon (August–September 2019). We have investigated the interiors of a number of clouds observed during CAMP2Ex focusing on Cu and CuCg (Tcu) cases. Our retrievals were routinely compared with the correlative measurements by lidar (HSRL-2) and cloud radar (APR-3) that were deployed on the same airborne platform (NASA P-3B) during this field experiment.

Research Scanning Polarimeter↗

Harnessing Vehicle Automation for Public Mobility -- An Overview of Ongoing Efforts

This presentation takes a look at the efforts to harness automated vehicle technology for public transport. The European CityMobil2 is the leading demonstration project in which automated shuttles were, or are planned to be, demonstrated in several cities and regions. The presentation provides a brief overview of the demonstrations at Oristano, Italy (July 2014), LaRochelle, France (Dec 2014), Lausanne, Switzerland (Apr 2015), Vantaa, Finland (July 2015), and Trikala, Greece (Sept 2015). In addition to technology exposition, the objectives included generating a legal framework for operation in each location and gaging the reaction of the public to unmanned shuttles, both of which were successfully achieved. Several such demonstrations are planned throughout the world, including efforts in North America in conjunction with the GoMentum Station in California. These early demonstration with low-speed automated shuttles provide a glimpse of the possible with a fully automated fleet of driverless vehicle providing a public transit service.

33 ADVANCED PROPULSION SYSTEMS↗

Quantitative Risk Analysis of High Safety Significant Safety-related Digital Instrumentation and Control Systems in Nuclear Power Plants using IRADIC Technology

This report documents the activities performed by Idaho National Laboratory (INL) during fiscal year (FY) 2021 for the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program, Risk Informed Systems Analysis (RISA) Pathway, digital instrumentation and control (DI&C) Risk Assessment project. In FY-2019, the RISA Pathway initiated a project to develop a risk assessment strategy for delivering a strong technical basis to support effective, licensable, and secure DI&C technologies for digital upgrades/designs. An integrated risk assessment technology for the DI&C systems (IRADIC technology) was proposed for this strategy, which aims to (1) provide a best-estimate risk-informed capability to quantitatively and accurately estimate the safety margin obtained from plant modernization, especially for the High Safety Significant Safety-related (HSSSR) DI&C systems, (2) develop an advanced risk assessment technology to support transition from analog to DI&C technologies for nuclear industry, (3) assure the long-term safety and reliability of vital HSSSR DI&C systems, (4) reduce uncertainty in costs and support integration of DI&C systems in the plant. To achieve these technical goals and deal with the expensive licensing justifications from regulatory insights, the IRADIC technology is instructive for nuclear vendors and utilities to effectively lower the costs associated with digital compliance and speed industry advances by: (1) defining an integrated risk-informed analysis process for DI&C upgrade, including hazard analysis, reliability analysis, and consequence analysis, (2) applying systematic and risk-informed tools to address common cause failures (CCFs) and quantify responding failure probabilities for DI&C technologies, particularly software CCFs, (3) evaluating the impact of digital failures at the individual level, system level, and plant level, (4) providing insights and suggestions on designs to manage the risks; thus, to support the development, licensing, and deployment of advanced DI&C technologies on nuclear power plant (NPPs). In this report, an approach for performing software CCF analysis, given limited data, is developed and demonstrated using a case study of a highly redundant digital reactor trip system. Consequence analysis is also performed based on different accident scenarios. Results indicate that plant modernization including the improvement of HSSSR DI&C systems will make great benefits to plant safety by providing more safety margins to accident management. In addition, a novel approach is proposed in this report for the quantification of software hazards when sufficient operational and testing data available. The method incorporates software development quality as well as strong analysis techniques to identify and link software defects to potential failure modes. The approach includes both semantic and test-based analysis to detect failures that can exist in different stages of the software development life cycle. This method is applied to an advanced human system interface relevant to reactor trip safety developed from the APR 1400 design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulation of the passive condensation cooling tank of the PASCAL test facility using the component thermal-hydraulic analysis code CUPID

For the analysis of transient two-phase flows in nuclear reactor components, a three-dimensional thermal hydraulics code, named CUPID, has been being developed. In the present study, the CUPID code was applied for the simulation of the PASCAL (PAFS Condensing Heat Removal Assessment Loop) test facility constructed with an aim of validating the cooling and operational performance of the PAFS (Passive Auxiliary Feedwater System). The PAFS is one of the advanced safety features adopted in the APR+ (Advanced Power Reactor +), which is intended to completely replace the conventional active auxiliary feedwater system. This paper presents the preliminary simulation results of the PASCAL facility performed with the CUPID code in order to verify its applicability to the thermal-hydraulic phenomena inside the system. A standalone calculation for the passive condensation cooling tank was performed by imposing a heat source boundary condition and the transient thermal-hydraulic behaviors inside the system, such as the water level, temperature and velocity, were qualitatively investigated. The simulation results verified that the natural circulation and boiling phenomena in the water pool can be well reproduced by the CUPID code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Cross flow characteristics in a three fuel assemblies

To evaluate the reactor thermal margin of APR+, reactor core flow distribution including both axial and lateral directional hydraulic resistances of fuel assemblies should be known. 3-Ch cross flow test facility has been constructed with three full-size fuel assemblies to investigate the cross flow characteristics. Performance tests have been performed. The axial and lateral directional hydraulic resistances of fuel assemblies have been measured. The test results have been compared to the CFD calculation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of F and B Operation Strategy with LPSI and H-SIT

In the current nuclear power plants (NPPs), most of the critical safety functions are provided by many active safety systems. However, in order to meet the futuristic goals of safety, relying on these active safety systems alone does not seem to be viable. As passive system has a strength on the mitigation of station black out accident and it also contributes to increase the diversity of mitigation way, application of passive system becomes a paramount in the nuclear industry to enhance the nuclear plant safety. Recently, many researches for developing passive systems and operation strategies have been carried out in the nuclear field. General passive systems and strategies, however, have a critical limitation, especially for passive injection systems. As these systems use gravity as their driving force, it is difficult to inject coolant in a passive way in a high-pressure condition thus depressurization has to be preferentially performed to do passive injection. The problem is that depressurization inevitably causes the loss of core inventory thus it is not preferred in order to secure plant safety. Hybrid safety injection tank (H-SIT) system was newly suggested a few years ago to passively inject the coolant into the reactor coolant system (RCS) without depressurization in a high-pressure condition. The H-SIT system is planned to be integrated into advanced power reactor plus (APR+). Generally, the H-SIT system can inject water using the pressure from nitrogen gas as a conventional safety-injection tank in low-pressure accidents, such as large and medium-break loss of coolant accidents (LOCA). Additionally, the H-SIT system can also inject water using gravitational force in high-pressure accidents. If a high pressure accident occurs, the pressure of each H-SIT is equalized with pressure of pressurizer through equalizing pipes, thus allowing the H-SITs to inject water by gravitational force. In the target plant, four H-SITs are planned to be installed. Each has a 2.5 in diameter equalizing pipe and it can be operated manually. Long-term cooling of core is an ultimate goal of all mitigation actions for plant safety and feed and bleed (F and B) operation strategy is one of the long-term cooling strategies in conventional pressurized water reactor (PWR). The important point of F and B operation is that injection for feed operation is performed by only high pressure safety injection (HPSI) pump because operation of low pressure safety injection (LPSI) pump needs the depressurization and it causes core dry out. As H-SIT is passively operated in an accident situation, it was originally designed for mitigation of station black out accident. Besides, operator can use the H-SIT system same as high pressure injection pump in any accident situations. Thus, function of high pressure injection by H-SIT can be used for feed operation when HPSI pumps fail. If it is possible, H-SIT can make up the core during depressurization then LPSI pumps can be used for F and B operation. In this study, F and B operation strategy with LPSI and HSIT is developed. This is a new concept for the long-term cooling operation. If this strategy is applied, low pressure injection pump can be successfully used for F and B operation thus operator has the additional mitigation way. As this strategy make plant safe even though HPSI and PAFS are both failed, it can effectively enhance the plant safety. For this strategy two RCGVSs and two POSRVs are needed as a depressurization system for bleed operation and only one LPSI is enough for feed operation. H-SIT operation is also needed to make up core inventory during bleed operation. For this operation, four H-SITs have to be used to make up core safely. Based on the risk analysis using PSA method, if this strategy is applied, core damage frequency is 1.868 e-6 which declined 7 percent from original model. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reliability Assessment of Safety-Critical Network Communication in a Digitalized Nuclear Power Plant

In analog instrumentation and control (I and C) systems for nuclear power plants (NPPs), most connections are comprised of hardwired point-to-point types. Since they are based on analog technologies, they are fragile to noise and require analog-to-digital conversion time. Therefore, many NPPs have adopted communication network for the exchange of safety-critical data between programmable logic controllers (PLCs) in digital I and C systems to effectively accommodate a huge number of field controllers. However, the primary issue of digital network communication in a safety-critical system involves potential hazards, such as partial or total loss of communication between PLCs, which may result in a failure of safety critical signal generation when it is needed. Therefore, the probability that a safety-critical system in digitalized NPP becomes unsafe due to a network failure must be evaluated to quantify the risk of digital I and C system. In Korea, the Engineered Safety Feature-Component Control System (ESF-CCS) was developed as one of the digital safety-critical system in Advanced Power Reactor- 1400 (APR-1400). The function of a digital engineered safety feature (ESF) actuation system and field actuator controllers of conventional NPPs are performed by the ESF-CCS. In this system, safety-critical network, High Reliable- Safety Data Network (HR-SDN), was employed for the safety-critical data transmission from group controllers (GCs) to loop controllers (LCs). In this study, a framework for assessing the reliability of a HR-SDN network communication between GCs and LCs in the ESF-CCS in addition to a fault-tree model for ESF components considering network failure between GCs and LCs were developed to assess the plant risk effect of a newly developed digitalized ESF-CCS. Based on the case studies and cut set analysis, the risk effect of network failure on plant risk and the important risk contributors of network failure were quantitatively addressed. A framework for identifying the potential hazardous states of network communication in the ESFCCS was proposed. In addition, a fault-tree model for network communication failure was developed to estimate the risk effects of network failure between the GCs and LCs on ESF-CCS signal failure. The developed fault-tree model was then applied to several case studies. The fault-tree model of ESF-CCS signal failure for ESF components required for various mitigation actions regarding NPP DBAs was designed by considering the identified hazardous states of network failure that would result in a failure to provide input signals to the corresponding LC. As a sensitivity study, three case studies were performed based on the periodic test methods for hardware components in HR-SDN module and their test intervals in this study. The quantitative results for three case studies demonstrated that the probability of overall network communication failure, which was calculated as the sum of the failure probability associated with each failure cause, contributed up to 1.58% on the Small-LOCA CD frequency. The results also revealed the important basic events related to network failure in the case studies which included CCF of hardware and software in HR-SDN module. This study is expected to provide insight into the development of the fault-tree model for the network failure in digital I and C system and into the quantification of the risk effect of network failure for safety-critical data transmission in NPPs. As a further study, the risk effects of network failure in the ESF-CCS on the plant risk can be estimated in a more detailed manner by analyzing the failure modes and causes in a sub-component level and the fault detection coverage of the fault tolerance techniques for network failure implemented in ESF-CCS after the detailed configuration of ESF-CCS is decided. In terms of the failure of manual ESF actuation, the relationship among the human action failures must be investigated to consider multiple human error condition since ESF-CCS provides multiple manual actuation to assure the diversity of the system. Since the conventional HEP method cannot accommodate the multiple conditions in a fault tree, condition-based human reliability assessment (CBHRA) method or the dynamic human reliability modeling approach can be applied to include a complex relationship among the automated safety signal generation and the human operator's manual actuation, avoiding the optimistic estimation of HEP of the human action failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Risk assessment of safety-critical data communication in digital safety feature control system - 205

As one of the safety-critical systems in Advanced Power Reactor-1400 (APR-1400) nuclear power plant (NPP), the Engineered Safety Feature-Component Control System (ESF-CCS) employs safety data link and network communication for transmitting safety component actuation to effectively facilitate various safety-critical field controllers. However, data communication failure risk in the ESF-CCS has yet to be fully quantified, the probability that a safety-critical system in digitalized NPP becomes unsafe due to a network failure must be evaluated to quantify the risk of digital I and C system. In this study, a fault tree model was developed to assess the data link and data network failure-induced unavailability of a safety-critical system function used to generate an automated control signal for actuating design basis accident mitigation equipment. Especially, the risk of data communication failure in a digital safety feature control system was analyzed in consideration of interconnection between safety-critical controllers and the fault-tolerant algorithm implemented in the network configuration. Based on the developed fault tree model, case studies were performed to quantitatively assess the unavailability of ESF-CCS signal generation due to safety data link and network failure and their risk effect on safety signal generation unavailability. This study is expected to provide risk information on the safety-critical data communication in a digitalized NPP instrumentation and control system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity Analysis of OECD ATLAS A5.1 Test using MARS-KS code

The ATLAS was designed to model a reduced-height primary system of a typical APR1400 which was developed by the Korean Nuclear Industry. The ATLAS has the 1/2-height, 1/144-area and 1/288-volume scales for the APR 1400 and it is scaled for full pressure and temperature conditions. A benchmark test, test A5.1, was performed to analyze and quantify the extent of scaling distortion in the ATLAS, as a part of a OECD-ATLAS project. The SB-CL-32 test which was conducted using the Large Scale Test Facility (LSTF) of the Rig-of-Safety Assessment-V (ROSA-V) Program was selected as the counterpart test to address the scaling issue. The detailed description of the LSTF test facility and the SB-CL-32 test can be found in the literature. The objective of the A5.1 test is to investigate the thermal hydraulic phenomena during cold leg small break LOCA with steam generator secondary side depressurization as the Accident Management action. In addition to that, the scaling effect analysis of ATLAS was performed in the several viewpoints. In this study, sensitivity analysis of A5.1 test was performed using MARS-KS code. Several experimental conditions of A5.1 test were varied to study effects on the reactor coolant system during the SBLOCA transient. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of Scaling Criteria for Modeling Condensation in Horizontal Tubes Using Reduced Pressure System and Simulant Fluid

Most of the currently operating nuclear power plants (NPPs), generation-II and III, are equipped with active safety systems, which raises concerns regarding those safety systems' operational reliability and the suitability of the accidents prevention measures. Following the severe accidents at nuclear power plants at Three Mile Island, Chernobyl, and recently in Fukushima some advance Pressurized Water Reactors (PWRs) have adopted passively cooled steam generator natural circulation system to remove the decay heat passively through the steam generator (SG). This is done by condensing steam from the steam generator inside a heat exchanger submerged in a tank of water or an air cooled system. The APR+ (Advanced Power Reactor Plus), which is currently being developed in South Korea, has adopted a Passive Auxiliary Feedwater System (PAFS), which removes the decay heat through the steam generator replacing the conventional active auxiliary feedwater system. The main part of the PAFS, in where the steam condenses, is the Passive Condensation Heat Exchanger (PCHX). The steam condenses under high pressure (7.4 MPa, 290 deg. C) in 8.4 m long horizontal tube, with 3 degrees inclination, with inner diameter of 44.8 mm and wall thickness of 3 mm. The PCHX consists of 4 bundles, each bundle has 60 condensation tubes. The performance of the PCHX performance should be evaluated. Condensation has been extensively studied; however, most previous experimental work was directed to low pressure (i.e., near atmospheric pressure) and small condensation tubes. Moreover, studies on the horizontal type heat exchanger are limited, since previous safety systems and experimentation work were directed to the vertical type heat exchangers. Due to the high construction cost of a full size high pressure condensation experiment, a reduced-size reduced-pressure condensation experiment is suggested to evaluate the heat removal performance of a condensation tube of the PAFS heat exchanger. A scaling methodology to be established to design a reduced-size reduced-pressure condensation experiment. This study attempts to develop a scaling criteria for the PAFS condensation system, and to apply it for modeling a high pressure water system by a low pressure Freon system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

01-06 DOME Construction Project

Construction Subcontract award to ESTECH - Aug 23 Partial Notice to Proceed for ESTECH mobilization - Sept 23 Final NTP for full construction activities - Oct 23. Quality Inspection Support awarded to ATLAS - Feb 24 Request for Proposal to award a Commissioning Agent subcontract issued - Apr 24 Construction activities projected completion - Jun 25

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗